Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | II₹1.4 LAccepted-AOC | II | Accepted-AOC L2 Bidder awarded 30 percent of total awarded amount after matching of rates to L1 bidder | |
| 2 | I₹3.2 LAccepted-AOC PLOT NO 14 SHIV COLONY KATI GHATI RAJGARH ROAD ALWER RAJ | ALWAR | ALWAR | RAJASTHAN | I | Accepted-AOC L1 Bidder awarded 70 percent of total awarded amount | |
| 3 | III₹5.3 LRejected-Finance | III | Rejected-Finance L-3, Not accepted by the competent authority |
Tender Value
₹5.8 L
EMD Value
₹11,578
Closing Date
17 Aug 2022, 6:00 pmClosed
EE(E), BSNL, ED-II, Jaipur
Room No. 105, Ist Floor, Telephone Exchange Building, Durgapura, Jaipur
Rate contract for call basis repairing of EI and Fans, servicing, shifting and ITC of AC units and miscellaneous work under BA Alwar.
2022_BSNL_124808_1
26/EE(E)/BSNL/ED-II/JP/2022-23
Open Tender
Electrical Works
Item Rate
180 days
Alwar
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
AO (Cash), O/o GMTD BSNL, ALWAR
₹11,578
14 Sept 2022
4 Aug 2022
22 Aug 2022
4 Aug 2022
17 Aug 2022
4 Aug 2022
Amount
Visit charges to detect and attend the fault of Electromechanical Services on call basis / complaint basis of TE buildings / BTS to attending the minor faults involving petty nature material (i.e. insulation tap / small pieces of wire etc.) and submission of detailed report for all type of fault to Engineering -In-charge etc complete as reqd. (Note:- Supply & Fixing Charges of any material required shall be paid extra) Remarks 1. The number of building (site) should be clubbed to attend the fault (atleast two sites to be clubbed). 2. The Visit Charge shall not be paid if the payment of schedule items made more than Rs.2500 for that particular building (site) of the individual agreement.
Witn in Municipal area of Alwar City
Outside the Municipal area of Alwar City
S/F of following electrical items in existing Electrical Installation I/c dismantling of existing faulty items (if required ) and connection, testing etc. as reqd.( Note- All spare of lighting systen should be of Make -Bajaj/crompton/philips /havells )
5 Amp. Piano Type switch.
3 Pin ,5 Amp. Socket outlet.
15/16 Amp. Switch.
15/16 Amp , 3/6 pin Socket outlet.
Ceiling rose
LED Type Indication lamp(R,Y,B)
Bakalite Holder
4'- 36 / 40 Watt Fluoresent Tube Rod
Electronic choke suitable 36 / 40 Watt tube fitting
Starter for fluorsent Tube Light
Side Holder for all type Tube Light fitting
2.5 to 4 MFD MPP capacitor for fan
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
2 x 1.5 sq. mm
3 x 1.5 sq. mm
2x2.5 Sq.mm.
4x2.5 Sq.mm.
Supplying and fixing following rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
(a) Single pole (5 A to 32 A rating)
(b) Single pole and neutral (5 A to 32 A rating)
(c ) Triple pole (5 A to 32 A rating)
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
(a) 63 amps
(b) 100 amps
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and aking good the same in case of recessed conduit as required.
Supplying and fixing metal box of 150 mm X 75 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.
Supplying and fixing metal box of 180 mm X 100 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 A & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
Supplying and fixing call bell/ buzzer suitable for D.C./A.C. single phase, 230 volts, complete as required.
S/F of following size Ceiling fan suitable for operation on 230 Volts ,single phase 50 Hz AC supply complete etc as reqd (without regulator)Make -( Bajaj/Polar /USHA /crompton /havells /orient )
S/F of D type fan hook made of 08 mm (NS)dia MS rod i/c fixing the same on ceiling with 2 pcs.of heavy duty Fasteners (M10x75mm) etc as required.
Supplying and fixing extra down rod of 20 cm length G.I. pipe,15mm dia, heavy gauge including painting etc. as required. (Note:More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
S/F of one module Stepped type electronic fan regulator in existing board I/c dismantling of existing faulty regular (if required ) and connection, testing etc. as reqd ( Make -Anchor /havells )
S/F of two module Stepped type electronic fan regulator in existing board I/c dismantling of existing faulty regular (if required ) and connection, testing etc. as reqd ( Make -Anchor /havells )
Pdg. Making opening in stone /brick wall for fresh air i/c cutting of wall for making suitable size opening, packing the extra space ,plaster finishing i/c cleaning the space after execution of Work etc as reqd.
Making square opening in brick/stone wall for exhaust fan up to 450mm sweep i/c cutting of wall for making suitable size hole ,packing the extra space ,plaster finishing i/c cleaning the space after execution of Work etc as reqd
SITC of 450mm sweep heavy duty exhaust fan with metallic louvers shutter 1400 RPM suitable for work on 230 V Single phase AC Supply ,i/c fixing the same wall surface /grill with suitable clamp i/c connection etc as reqd (Make -Almonard/crompton/Bajaj/USHA).
S/F of 450 mm sweep heavy duty mark II oscillating type Padestal fan with 3 speed control regulator having powder coated guard and aluminium die cast blade ,1440 RPM speed suitable for working on 230 V 50 Hz single phase AC supply & i/c connection etc. complete as required (Almonard /Crompton/Bajaj)
S/F of 20W -4 feet long Retro fit LED T-8 Tube rod in polycaronate housing having efficency 100 lumes /watt suitable for work on 230V AC Supply i/c fixing the same on existing all type flu fitting i/c modification of existing fitting wiring etc complete as reqd.(Make -Philips /crompton/Havells /Bajaj/Wipro ).
SITC of 1x18/20 Watt LED batten type slim LED lighting fixture made of polycarbonate having efficency 100 lumes /watt complete, suitable for work on 230 volt 50Hz AC supply i/c connection testing etc complete as required.(Make -Philips /crompton/Havells /Bajaj/Wipro/Surya).
S/F of 6 W Surface mounting LED panel square flush model suitable for work on 230 V etc as reqd (Make -Philips /crompton/Havells /Bajaj/Wipro ).
S/F of 12 W Surface mounting LED panel square flush model suitable for work on 230 V etc as reqd (Make -Philips /crompton/Havells /Bajaj/Wipro ).
SITC of 25 Watt Energy Efficient LED type Road Light luminare with pressure die cast aluminum with mid power LED's as light sources & Heat Resistant toughended glass with frame cover and integral electronic driver complete with IP 65 protection ,min.system efficacy 100 lm/Watt., THD<10%, PF>0.95 suitable for work on 140-270 V AC Supply i/c ixing on existing GI bracket / Pole suitable modificaion of braket (if required) and connection with 3 Core 1.5 sqmm PVC insulated PVC Sheathed copper conductor cable from fitting to MCB in MS box through GI Bracket / Pole etc. as reqd. The fixture shall have a corelated color temperature of at least 5000K and a CRI of > 70. The Light system shall be designed for system life 50000 hour i/c removing of existing faulty light etc as reqd (Make -Philips /crompton/Havells /Bajaj/Wipro ).
S/F of ABS make moulded weather proof ,shocked proof ,fire retartand ,Compound light control gear box of size 200mmx150mm x100mm suitable for pole mountung and cable entry from bottom side with side hinges door i/c S/F of 6 Amp "C " Curve SP MCB on Din channel and two no 16A neutral Link i/c dismantling of existing faulty/unserviceable M S Box I/c connection testing etc as reqd (Make SINTEX or SS )
Supplying and laying of following size of pvc insulated pvc sheathed 1.1 kv grade Aluminium conductor armoured cable confirming to relevant IS-Specification on surface of wall / hume / existing masonry open duct including end termination with brass compression gland & aluminium lugs (If required) etc complete as reqd. (Make -Polycab/havells/finolex)-
2 x 6 Sqmm.
4 x 16 Sqmm.
3-1/2 x 35 Sqmm.
3-1/2 x 50 Sqmm.
Supplying and fixing of following size of flat flexible copper cable on surface/ recess, suitable for work on 230 volt, 50 HZ AC supply i/c connection etc complete as reqd. (Make -Polycab/havells/finolex)
3x2.5 sq mm
3x1.5 sq mm
Refilling of exisitng CO2 type 4.5 Kg Capacity Fire Extinguishers of following capacity with CO2 up to desired specified pressure i/c transportation of empty the cylinder to & fro , cleaning, refilling the gas and testing etc. complete as reqd. ( Note - Work shall be carried out only by specialized agency and necessary test certificate for each refilled cylinder is to be submitted).
Refilling of exisitng Dry Chemical Powder type up to 10 Kg Capacity Fire Extinguishers with help of Chemical Powder and refilling of Cartridge i/c transportation, empty the cylinder, cleaning, refilling the cartridge and testing etc. complete as reqd. ( Note - Work shall be carried out only by specialized agency and necessary test certificate for each refilled cylinder is to be submitted )
S/F of One meter hose pipe with horm for 4.5 kg Co2 type fire extingusher i/c fixing and testing etc as reqd.
Replacement & Fixing of 12 Volt and following AH Sealed maintenance free battery duly charged i/c removing the existing battery, connect the terminal with new one I/c testing etc. complete as reqd. (Make- Exide/ Amaron)
S/F of Analog dial type 3 module time switch suitale for work on 230V Single phase AC Supply with 16 A Capacity and with one change over facility with base /din mounted facility i/c connection etc as required (M/S L&T, Havells or SS)
Rewinding of following fan motor with suitable gauge copper winding wire I/c dismantling, servicing, replacement of bearing/bush and reinstallation, testing etc. as reqd.
Ceiling fan up to 1400 mm size
Exhaust fan / Wall mounting fan up to 450 mm size
Air circulator/ pedestal Fan Up to 450 mm size
Servicing of ceiling fan of up to 1400 mm. sweep with greasing ,oiling including replacement of defective ball bearing I/c dismantling & re-installation etc. comp. as reqd.
Servicing ,Oiling & Greasing of Heavy duty air circulating/ wall mounting fan including replacement of defective ball bearing i/c dismantling and re-installation etc. comp. as reqd.
Dismentling of existng all type ceiling fan/ Wall Fan/Exhaust fan from true ceiling / Wall i/c disconnection of wire andshifting the same up to store as per direction of -In-charge etc as reqd.
Dismantling of the existing split /window type AC Unit complete with indoor unit,outdoor unit stand, refrigerant piping,drain pipe,shifting the dismaltled items to a safe place in exchange premises and handing over to the incharge,packing of SPAC wall hole ,making good the damage etc as reqd (Note- Existing refrigerent from working Split AC to be stored in compressor before dismentling for further use at new location).
Transportation of Split /Window AC units with all acessories like indoor ,outdoor unit ,copper pipe ,drain pipe ,partical board as dismentalled from One TE/BTS to various TE /BTS sites in SSA as per direction of Engineer-In-Charge up to 50 KM i/c. loading,unloading etc. as reqd.
Installation, Testing & Commissioning of the 1.5 TR inverter type Split type AC unit at a specified location as per direction of Engg-In-charge by mounting/fitting Indoor and Outdoor units , making opening in wall, laying and fixing of both liquid and hot gas lines , inter connecting wiring for both indoor outdoor units up to 5 mtrs length and ,interconnecting the indoor unit and outdoor unit with refrigerant line, insulating the refrigerant pipe with expandable polyethylene Foam tubing unit and fixing with suitable MS shaddle , Leak testing entire system ,vacuemising the system ,charging of Refrigerant gas in the unit ,making power supply connections from the power point,and making good the damages etc.as required.
Pdg and Fixing additional 1/4"&5/8" size or size same as supplied by Split AC manufacturer refrigerant copper piping with 3x2.5 sq.mm. PVC Insulated PVC Sheathed copper cable i/c covering of Copper Pipe with polystyrene insulation i/c cutting ,brazing ,jointing,bends, sockets etc as reqd. (Note- Combined Length shall be measured)
Provision of Top up of R-22/R-32 /410 gas in existing Window A.C /Split A.C units, i/c flushing, testing etc. as required.
S/F of 50 mm dia 2 mm thick PVC pipe on wall / surface for protection of refrigerant pipe of split AC units etc.i/c elbo /bend /socket etc as complete as reqd.
Closing of existing window in AC plant room to prevent AC leakage by brick masnoary i/c plastering , finishing etc complete as reqd as reqd.
General Servicing of 1.5 /2.0 TR WAC/SAC units at site of different make I/c removing from existing position if reqd., dismantling of faulty parts, cleaning the air filter, cleaning the condenser and evaporator coil with help of caustic soda soap solution, lubrication of moving parts, complete checking, testing and minor faults rectification i/c replacement of knobs/ wiring kit (if required), setting of thermostat, preparing report including tightness of all electrical connections from SP MCB in DB to DP MCB/Plug & socket to TDR to AC unit etc as reqd.
Charging of Refrigerant gas R-22 up to specified pressure(as per manufacturer's recommendation) in following capacity AC units and pressure testing by nitrogen, vaccumisation for 2 hours, purging with gas and testing commissioning of the AC unit etc. as reqd. Note: One job consists of charging of Gas in one compressor i.e.. One complete air conditioning circuit only.
1.5 TR WAC/ Split AC
Dismentling of existing aluminum partation, doors, fixed glass panes i/c remoing of vertical members fixed in floor with rawal plug and shifting and stacking of sericable material in the same building within 50 meter lead as directed by Engineering-in-charge.
Refixing of the available dismentalled aluminum partation at first floor AC plant room in same building by cutting and jointing the existing member ,making arrangement for door with cutting floor and repairing by cement mortor the floor after fixing spring fixing with rawal plug of required dia and size ,cutting the board ,glass panes of required size to adjust the panel size in the width of room if required i/c necessary filling up the gaps at junction i.e at top ,bottom,and sides with required EPDM rubber/neoprene gasket etc .Aluminum section shall be jointed mechanically whenever required i/c cleat angle ,aluminum snap beading for glazing /paneling ,C.P.brass /stainless steel screw (Cost of EPDM rubber /neoprene gasket if required to be provided new shall nbe paid for seperately).
General Servicing and repairing of existing monoblock type motor pump / submerssible set of capacity up to 5 HP including oiling, greasing, change of bearings, glandpacking, shaft sleeves, on complete pump set etc. as reqd. I/c minor civil work etc. as reqd.
Unlowering / Withdrawing of existing submerssible pump alongwith it's pipe , cable & steel rope (If exist) from existing bore and lowering the same up to the suitable depth with help of chain and pulley to install the pump vertically i/c fixing the clamping nuts, laying of existing steel wire rope with fixing arrangement from pumpset bottom to top of the wall with existing clamps, nut bolts and refixing the existing M.S. borewell cover i/c replacement of packing etc complete as required.
Rewinding of Single / Three phase submerssible / Monoblock pump set motor of rating up to 5 HP with help of copper wire with polyrab/ pvc insulated copper conductor wire of suitable gauge i/c replacement of cable seal rings, spray painting of pump etc as required.
P/Making water sealed joint with existing pumps set cable and laying the same in existing pipe and borewell complete as required.
S/F of following MS items to be used for for frame work /Exhaust fan grill I/c Cutting , welding painting etc. as required.
35mm X 35mm X 5mm Angle iron
25mm X 25mm X 3mm Angle iron
1"x1" square MS wire mesh of 18 SWG wire
20 SWG MS Sheet
20x3 mm MS flat
Manohar Electricals
Singhal Electricals, Jaipur
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .