Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.8 LAccepted-AOC | L1 | Accepted-AOC DUE TO BEING L1 AND REASONABLE | |
| 2 | L2₹27.8 L+₹1.1 L (3.94%)Rejected-Finance R O H NO 55 SEC D BHARAT NAGAR TALAB TILLO JAMMU 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | L2 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE | |
| 3 | L3₹32.6 L+₹5.8 L (21.8%)Rejected-Finance | L3 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
7 Feb 2023, 6:00 pmClosed
GE (SOUTH) AKHNOOR
GE (SOUTH) AKHNOOR C/O 56APO
REPAIR AND MAINT OF AIR CONDITIONER, WATER COOLERS AND COOLING APPLIANCES INCL CONNECTED ITEMS AND REPAIR REPLACEMENT TO STREET LIGHT , CONTROL SWITCHES AND OTHER CONNECTED ITEMS IN OTM AND MD ACCN AT SOUTH BANK AND NORTH BANK AT AKHNOOR OF UNDER GE
2023_MES_574274_1
GES/AKH-25/2022-23
Open Tender
Civil Works
Item Rate
240 days
GE (SOUTH) AKHNOOR
MES EN-LISTED CONTRACTOR WITH CLASS D AND ABOVE WITH CATEGORY b(i)
9 documents required · 9 mandatory
₹500
GE (SOUTH) AKHNOOR
₹76,000
20 Feb 2023
10 Jan 2023
9 Feb 2023
10 Jan 2023
7 Feb 2023
24 Jan 2023
Amount
Disconnecting and taking down the existing perimeter/street light fittings of any type and any specifications or any accessories related to tperimeter/street light fittings of any descriptions, fitted/ fixed on poles, buildings or watching towers of any heights and any location, and re-fixing the same after necessary repairs/ replacement of defective parts including rectifying the same as per directions by concerned JE E/M and Engineer-In-Charge, at various locations, complete all as specified and directed by Engineer-In-Charge. Note: (i) Cost of T&P, ladder or mechanical lift shall be deemed included in quoted rate. (ii) Supply of spare parts of timer switch shall be measured and paid separately under relevant items of Schedule ‘A’/ BOQ. (iii) Cost of connecting up with twin core twisted flexible copper conductor cable with suitable size shall also deem to be included in the quote rates.
Supply only electronic driver , as per existing sample suitable for street light fitting 30 Watt
Supply only electronic driver , as per existing sample suitable for street light fitting 45/50 Watt
Supply only electronic driver , as per existing sample suitable for street light fitting 60 Watt
Supply only PVC insulated and PVC sheathed copper flexible cable stranded of 1.5 sqmm twin core flat or circular with connection from light fittings to OH conductor or upto junction box all as directed
S&F in replacement of SITC of high-quality integrated LED Street Light with a minimum system lumen of 4950 Lm and system wattage not exceeding 45W with a nominal efficiency 110 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI >70. The housing should be of non-corrosive high-pressure die-cast aluminum with heat resistant toughened clear glass to with stand extreme environments with PF > 0.95. Lifetime of 50K hours @L70.The Ingress protection should be minimum IP 66 with an IK rating of 07. The Luminaire should have 4KV internal 10KV external surge protection in the Luminaire.Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters and including suitable size and length of flexible copper wire and making the connection, complete all as specified, complete all as specified. Make : Bajaj cat part No ENXT P 54L WH PO PC SD or Equivalent makes in Crompton/Philips. Warranty certficate for 2 years to be provided by Employee of Organization of Terittory.
S&F in replacement of SITC of high-quality integrated LED Street Light with a minimum system lumen of 6600 Lm and system wattage not exceeding 60W with a nominal efficiency 110 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI >70. The housing should be of non-corrosive high-pressure die-cast aluminum with heat resistant toughened clear glass to with stand extreme environments with PF > 0.95. Lifetime of 50K hours @L70.The Ingress protection should be minimum IP 66 with an IK rating of 07. The Luminaire should have 4KV internal 10KV external surge protection in the Luminaire.Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters and including suitable size and length of flexible copper wire and making the connection , complete all as specified, complete all as specified. Make : Bajaj cat part No ENXT P 72L WH PO PC SD or Equivalent makes in Crompton/Philips. Warranty certficate for 2 years to be provided by Employee of Organization of Terittory.
Supply and fixing in replacement of 1 x 30 Watt LED Flood Floodlight luminaire with polycarbonate optics, pressure die-cast housing along with IP66 ingress protection , CCT 5700K 4kV inbuilt surge protection. E cacy 110 lm/W all as directed Make : Bajaj cat part No GLEAM F 33L WH SY PC SD V2 or Equivalent makes in Crompton/ Havells. Warranty certficate for 2 years to be provided by Employee of Organization of Terittory.
S&F in replacement of LED Post Top with a system lumen output of 2800 lumens and a minimum system efficacy of 80 lm/W. . The luminaire should have a color temperature of 3000K to 5700K and CRI > 70. The luminaire shall meet IP65 & IK07 protection with THD < 10% and PF > 0.95. The luminaire shall have Cast aluminium spigot housing with Opal acrylic diffuser. The total power consumption should not exceed 40W (including driver) and including suitable size and length of flexible copper wire and making the connection, complete all as specified and as directed by Engineer-In-Charge. Make : Bajaj cat part No SBGCTN 40W LED WW or Equivalent makes in Wipro/Philips. Warranty certficate for 2 years to be provided by Employee of Organization of Terittory.
Supply and fixing in replacement of LED Bollard light fittings 10 W IP65 protection with robust design and efficient light distribution complete including PCC foundation 30x30x30 cm all as directed .Make : Crompton cat No LBLTW-10-CDL/WW or equivalent makes in Philips/Bajaj/Wipro
S&F in replacement of LED Post Top with a system lumen output of 1625 lumens and a minimum system efficacy of 70 lm/W. The luminaire should have a color temperature of 3000K to 5700K and CRI > 70. The luminaire shall meet IP65 & IK07 protection with THD < 10% and PF > 0.95. The luminaire shall have Cast aluminium spigot housing with Opal acrylic diffuser. The total power consumption should not exceed 25W (including driver) and including suitable size and length of flexible copper wire and making the connection, complete all as specified and as directed by Engineer-In-Charge. Make : Bajaj cat part No BGCTN 25W LED WW or Equivalent makes in Wipro/Philips. Warranty certficate for 2 years to be provided by Employee of Organization of Terittory.
Disconnecting and taking down the existing street light timer from poles of any type and any specifications , fitted/ fixed on poles, and re-fixing the same after necessary repairs/ replacement of defective parts including rectifying the same as per directions by concerned JE E/M and Engineer-In-Charge, at various locations, complete all as specified and directed by Engineer-In-Charge. Note: (i) Cost of T&P, ladder or mechanical lift shall be deemed included in quoted rate. (ii) Supply of spare parts of timer switch shall be measured and paid separately under relevant items of Schedule ‘A’/ BOQ. (iii) Cost of connecting up with twin core twisted flexible copper conductor cable with suitable size shall also deem to be included in the quote rates.
Supply only Nature time switch, 230 V automatically switching ON/OFF as per seasonal changes single phase upto 5 KW capacity Make : Kakatiya/ Indoasian/Legrand
Supply only Timer switch 3 phase with 48 hours back-up charge programmable and operated within 5 minutes of preset time of current rating 32 amps Make Schneider/Legrand/BCH
Supply only Power contractor TP 415 volts, 32 amps without aux relay suitable for operating of timer switch Make : L&T / C&S/ BCH
MCB, single pole, 6 to 32 Amps, 240 Volts, 50 Hz, including necessary incoming and out going electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
MCB, Single Pole and Neutral, 40-63 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
Supply and fixing in repalcement light bracket made out of GI pipe 1.5 Mtr long, 40 mm dia medium grade bent to shape as directed including clamps made out of 40 mm x 6 mm flat for fixing bracket suitable for PCC poles including nuts and bolts, washers and other connected items of required size including painting with one coat of aluminium paint over a coat of red oxide/primer all as specified and as directed.
Replacement of old cracked/ damaged, concrete poles with new pre-stressed concrete pole, 9.0 metres long, cross section 102mmx172mm at top and 102mmx279mm at bottom, class 10, including painting strips in black and white colour, 300mm thick, upto 1.50mtr height, from top of PCC coping with synthetic enamel paint after preparing the surface, complete all as specified and as directed by Engineer-In-Charge. Note: Excavation, earth work and concrete in foundation shall be measured and paid separately under respective items of BOQ.
Replacement of old unserviceable/ damaged LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 16.0 Sqmm, 4.0-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 10.0 Sqmm, 4.0-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 10.0 Sqmm, 2.0-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed by Engineer-In-Charge.
Replacment of switch fuse iron clad of sheet metal SP fused and neutral link of capacity 32 Amps 240 volts, complete all as specified and directed by Engineer-In-Charge. Make: Havells/Schneider/ ABB/ Legrand.
Excavation in trenches in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable,erection of poles, stays, pipes etc and not exceeding 10sqm on plan and getting out all as directed.
Excavation in trenches, not exceeding 1.50 mtr wide and exceeding 1.50mtr but not exceeding 3.0mtrs in depth, not exceeding 10 Sqm on plan and getting out, in any type of soil, for laying electric cables or foundation of poles/ stays etc, complete all as specified and as directed by Engineer-In-Charge.
Returning, filling in any type of soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm all as specified.
Removal of excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above in starting point.
Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed by Engineer-In-Charge. Note: Punned thickness shall be measured.
Sub class ‘B’ bricks, modular size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning for mechanical protection of cable, with width equal to the length of the brick, complete all as specified and directed by Engineer-In-Charge.
Material and labour for Plain cement concrete (1:4:8) type D-2 (using 40mm graded crushed stone aggregates ) as in foundation filling of pole etc complete all specified and directed.
M&L for providing cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) for coping of poles including necessary form work and finished the surface complete all as specified and directed by Engr in charge.
Material and labour GI tubing 40 mm dia, light grade galvanized for cable protection and fixing of post top lantern with all connecting items (like suitable size of clamps, angle, nut & bolts) for holding of pipe with pole duly painted complete all as specified and directed. Make : Tata /Jindal / Swastik.
Replacement of PVC junction box of size 100MMx100MMx50MM mounted on GI pipe with MS clamp made out of 40 mm x 6 mm flat for fixing box on pole/wall including terminal point mounted on epoxy insulator for cable connection with 01 No MCB SP 10 amps complete all as directed. Make : Sintex/ L&T/ Legrand/ ABB/ Siemens
Material & labour for earthing complete with galvanised cast iron earth plate electrode of size 600x600x6.3mm thick buried directly in ground less than 3.0m deep below normal ground level as earth electrode with top edge of the earth plate not less than 2.25mtr below ground level using GI strip 32x6 mm dia as earth continuity conductor connected to earth plate by means of welding, GI thimbles, nuts, bolts & washers all as directed including providing earth wire protection pipe of GI tubing light grade 40mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover with handle of angle iron frame of size 40 x 40 x 6mm in PCC 1:3:6 adequate quantity of charcoal dust and salt and kalmi shore all around the earth plate, earth work in any type of soil remaining surplus excavated material all as required at site and specified in EP No 3 of SSR part I 2009 or directed by Engineer-in-charge and incl testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI strip of size 32x6mm with protection pipe of 40mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates enhanced by (-40)%. (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the GI wire 4 mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filling with fixing arrangement, funnel wire mesh and earth work in soft soil returning filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI wire of size 4 mm dia with protection pipe of 15mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates enhanced by (-40)%. (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
S&F in replacement of PVC insulated FRLS flexible cable with PVC insulated, sheathed, multi-stranded copper conductor 1100 volts grade, size 1.50 Sqmm, 3.0-core for connection, complete all as specified and as directed by Engineer-In-charge.
Disconnecting all electric connections and taking down of air conditioner of any capacity, Split type, installed at the site or mounting at any height and transport to MES store yard/ workshop for servicing, cleaning/ removing the dust internally and externally, replacement of defective spare parts, as required including washing/ cleaning the outer surfaces, evaporator, condensor, air filters, ground chassis including making dry after washing, lubrication to rotatory parts, testing after repairs including making necessary connection to the power point (if required), complete all as specified and as directed by Engineer-In-Charge. Note: (i) New spare parts/ items required in replacement of old defective spare parts/ items shall be measured and paid separately under respective items. (ii) Cost of transportation from site to workshop for repair and workshop to site after repair, labour required for repairs/ replacement of spare parts being repair/ replaced, shall be deemed included in quoted rate.
Description all as serial item No-38.00 here-in-before but for air conditioner of any capacity, window type.
Supply only following new spare parts required to replacement for repairs of air conditioner (capacity as mentioned) :- (a) Motor for condensor of air conditioner, capacity 1.50 ton, window type, complete all as specified and as directed by Engineer-In-Charge.
(b) Condensing coil for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
(c) Thermostat switch for air conditioner, capacity 1.50/ 2.0 ton, window type, complete all as specified and as directed by Engineer-In-Charge.
(d) Starting relay for air conditioner, capacity 1.50 Ton, window type, complete all as specified and as directed by Engineer-In-Charge.
(e) Over load protection relay, air conditioner, capacity 1.50 Ton, window type, complete all as specified and as directed by Engineer-In-Charge.
(f) Wiring kit for air conditioner, window type, capacity 1.50 Ton and as per existing specifications, including internal wiring, complete all as specified and as directed by Engineer-In-Charge.
(g) Front grill for air conditioner of 1.50 Ton capacity as per existing specifications, complete all as specified and as directed by Engineer-In-Charge.
(h) Air filter for air conditioner mettalic type), capacity 1.50 ton, window type, complete all as specified and as directed by Engineer-In-Charge.
(j) Gas/ refrigerant filter for air conditioner mettalic type), capacity 1.50 ton, window type, complete all as specified and as directed by Engineer-In-Charge.
(k) Cooling coil for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
(l) Condensor fan blade for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
(m) Operating knob for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
(n) Fan for blower motor of air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
(o) Hermetic sealed unit (compressor) suitable for window type, uncut, for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
(p) Hermetic sealed unit (compressor) suitable for split type, uncut, for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
(q) Hermetic sealed unit (compressor) suitable for split type, uncut, for air conditioner of 2.0 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
(r) Printed Circuit Board for air conditioner, split type, capacity 1.50 Ton and as per existing specifications, including internal wiring, complete all as specified and as directed by Engineer-In-Charge.
(s) Blower motor for air conditioner, capacity 2.0 ton, split type, complete all as specified and as directed by Engineer-In-Charge.
(t) Copper tubes, size ¼ inches with insulation rubber, suitable for air conditioner of any capacity, split type, and as per existing specifications, fixing in repairs at any levels including clamps and screws, complete all as specified and as directed by Engineer-In-Charge.
(u) Copper tubes, size ½ inches with insulation rubber, suitable for air conditioner of any capacity, split type, and as per existing specifications, fixing in repairs at any levels including clamps and screws, complete all as specified and as directed by Engineer-In-Charge.
(v) Copper tubes, size 3/8 inches with insulation rubber, suitable for air conditioner of any capacity, split type, and as per existing specifications, fixing in repairs at any levels including clamps and screws, complete all as specified and as directed by Engineer-In-Charge.
(w) Copper tubes, size 5/8 inches with insulation rubber, suitable for air conditioner of any capacity, split type, and as per existing specifications, fixing in repairs at any levels including clamps and screws, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old/ damaged base tray with new base tray of mild steel 1.60mm thick, duly painted with powder coated paint, suitable for air conditioner, capacity 1.50 Ton, by removing and re-fixing compressor, condensor coil, copper tube, complete all as specified and as directed by Engineer-In-Charge.
Recharging/ replacement/ filling of refrigerant (R-134a), suitable for air conditioner of any capacity and any specifications including testing and repairing against any leakage by welding, soldering, complete all as specified and as directed by Engineer-In-Charge.
Disconnecting all electric connections and transporting water coolers of any type and of any capacity, to MES store yard/ workshop for repairing and servicing, by cleaning/ washing the water storage tank, compressor and outer body, tightening the hinges/ screws and replacement of defective spare parts including testing after repairs and making necessary connection to the power points, complete all as specified and as directed by Engineer-In-Charge. Note: (i) New spare parts/ items required in replacement of old defective spare parts/ items shall be measured and paid separately under respective items. (ii) Cost of transportation from site to workshop for repair and workshop to site after repair, repair/ replacement and minor spare parts required of water coolers, shall be deemed included in quoted rate.
Supply only following new spare parts required to replacement for repairs of water coolers (capacity as mentioned) :- (a) Hermetic sealed unit, for water cooler capacity 40/80 liters, complete all as specified and as directed by Engineer-In-Charge.
(b) Hermetic sealed unit, for water cooler capacity 60/120 liters, complete all as specified and as directed by Engineer-In-Charge.
(c) Hermetic sealed unit, for water cooler capacity 150/150 liters, complete all as specified and as directed by Engineer-In-Charge.
(d) Condensor fan motor of 1/35 HP for water cooler of any capacity, complete all as specified and as directed by Engineer-In-Charge.
(e) Automatic thermostat suitable for water cooler any descriptions and of any capacity, complete all as specified and as directed by Engineer-In-Charge.
(f) Condensor fan blade for water cooler, capacity 40/80, 60/120 and 150/150 liters, complete all as specified and as directed by Engineer-In-Charge.
(g) Condensor coil for water cooler, capacity 40/80, 60/120 and 150/150 liters, complete all as specified and as directed by Engineer-In-Charge.
(h) Strainer (Micro filter) for ¼ gas (refrigerant) for condensor coil for water cooler, capacity 40/80, 60/120 and 150/150 liters, complete all as specified and as directed by Engineer-In-Charge.
(j) Evaporator coil for water cooler, capacity 40/80, 60/120 and 150/150 liters, complete all as specified and as directed by Engineer-In-Charge.
Recharging/ replacement/ filling of refrigerant (R-134a), suitable for water cooler any descriptions, capacity 40/80 Litres including testing and repairing against any leakage by welding, soldering, complete all as specified and as directed.
Recharging/ replacement/ filling of refrigerant (R-134a), suitable for water cooler any descriptions, capacity 60/120 Litres including testing and repairing against any leakage by welding, soldering, complete all as specified and as directed.
Recharging/ replacement/ filling of refrigerant (R-134a), suitable for water cooler any descriptions, capacity 150/150 Litres including testing and repairing against any leakage by welding, soldering, complete all as specified and as directed.
S&F in replacement of old unserviceable push button bib tap with new push button bib tap, long shank, cast copper alloy, chromium plated, fancy type, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Spray painting of water cooler capacity 40/80 Litres with two coats of synthetic enamel paint of approved colour by spraying machine including filling cavities with filler, after cleaning all dusts and removing of dent from surfaces including writing of MES Nos. with synthetic enamel paint of black colour on lateral side of water cooler, complete all as specified and as directed by Engineer-In-Charge.
Spray painting of water cooler capacity 60/120 Litres with two coats of synthetic enamel paint of approved colour by spraying machine including filling cavities with filler, after cleaning all dusts and removing of dent from surfaces including writing of MES Nos. with synthetic enamel paint of black colour on lateral side of water cooler, complete all as specified and as directed by Engineer-In-Charge.
Spray painting of water cooler capacity 150/150 Litres with two coats of synthetic enamel paint of approved colour by spraying machine including filling cavities with filler, after cleaning all dusts and removing of dent from surfaces including writing of MES Nos. with synthetic enamel paint of black colour on lateral side of water cooler, complete all as specified and as directed by Engineer-In-Charge.
Disconnecting all electric connections and transporting refrigerator of any capacity and any type, to MES store yard/ workshop for repairing and servicing, by cleaning/ washing the internal surfaces and racks, compressor and outer body and lubrication of movable parts, tightening the hinges and replacement of defective spare parts including testing after repairs and making necessary connection to the power points, complete all as specified and as directed by Engineer-In-Charge. Note: (i) New spare parts/ items required in replacement of old defective spare parts/ items shall be measured and paid separately under respective items. (ii) Cost of transportation from site to workshop for repair and workshop to site after repair, repair/ replacement and spare parts such as lubricating oil/ grease of refrigerator required being repair/ replaced, shall be deemed included in quoted rate.
Supply only following new spare parts required to replacement for repairs of refrigerator (capacity as mentioned) :- (a) Thermostat with auto defrost button for refrigerator of any descriptions, capacity 165 to 340 litres, complete all as specified and as directed by Engineer-In-Charge.
(b) Hermetic sealed unit uncut, capacity 1/8 HP, suitable for refrigerator of 165 to 210 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
(c) Hermetic sealed unit uncut, capacity 1/6 HP, suitable for refrigerator of 210 to 285 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
(d) Hermetic sealed unit uncut, capacity 1/6 HP, suitable for refrigerator of 300 to 340 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
(e) Hermetic sealed unit, capacity 1/6 HP, suitable for deep freezer of 300 to 405 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
(f) De-frost timer TMDE706 SC cycle time 6H35M, 60 Hz/ 7H54M, 50 Hz, single phase, 220- 240 Volts, suitable for deep freezers, complete all as specified and as directed by Engineer-In-Charge.
(g) Bimotel component of 4/3 wire for freezer/ refrigerator, capacity 285 to 340 liters, complete all as specified and as directed by Engineer-In-Charge.
(h) Relay, PTC of any type, suitable for refrigerator of 300/310 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
(j) Refrigerator door seal of rubber gasket including proper insulation, for refrigerator of 165 to 215 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
(k) Refrigerator door seal of rubber gasket including proper insulation and magnetic system, for refrigerator of 280 to 340 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
(l) Lamp suiatble for refrigerator, pin/ screw type, for refrigerator of any capacity, complete all as specified and as directed by Engineer-In-Charge.
(m) Evaporator coil for refrigerator, capacity 165 to 180 liters, complete all as specified and as directed by Engineer-In-Charge.
(n) Evaporator coil for refrigerator, capacity 210 to 340 liters, complete all as specified and as directed by Engineer-In-Charge.
(o) Drain/ Ice tray suitable for refrigerator, capacity 165 to 215 liters, complete all as specified and as directed by Engineer-In-Charge.
(p) Drain/ Ice tray suitable for refrigerator, capacity 280 to 340 liters, complete all as specified and as directed by Engineer-In-Charge.
(q) Wiring kit for refrigerator, capacity 280 to 340 liters and as per existing specifications, including internal wiring, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged PVC staging/ plastic stand with new PVC staging stool/ plastic stand of different sizes, for refrigerator of 165 to 340 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
Recharging/ replacement/ filling of refrigerant (R-134a), suitable for refrigerators/ deep freezers, any capacity including testing and repairing against any leakage by welding, soldering, complete all as specified and as directed.
S&F in replacement of Sheet metal enclosures with socket plug top and MCB suitable for single pole and neutral including a two pin and earth plug and socket complete with one single pole MCB, single pole, 40 Amps, 240 Volts, complete all as specified and as directed.
Disconnecting all electric connections from mains and transporting voltage stabilizer of any type and 1.0 to 5.0 capacity, to MES store yard/ workshop for repairing/ servicing, by cleaning the outer body and replacement of defective spare parts including testing after repairs and making necessary connection with power points, complete all as specified and as directed by Engineer-In-Charge. Note: (i) New spare parts/ items required to replaced shall be measured and paid separately under respective items. (ii) Cost of transportation from site to workshop for repair and workshop to site after repair, repair/ replacement and minor spare parts required being replaced of voltage stabilizer, shall be deemed included in quoted rate.
Supply only following new spare parts required to replacement for repairs of voltage stabilizer (capacity as mentioned) :- (a) Voltmeter, rating 0-300 Volts, analog type, round shap, 2.50 inches dia, complete all as specified and as directed by Engineer-In-Charge.
(b) Power relay, 24 Volts, 260 Ohms, 30 Amps (set of three) suitable for voltage stabilizer, complete all as specified and as directed by Engineer-In-Charge.
(c) Power relay, 18 Volts, 500 Ohms, 30 Amps (set of three) suitable for voltage stabilizer, complete all as specified and as directed by Engineer-In-Charge.
(d) Bakelite terminal strip, (bakelite connector), 4-way, suitable for voltage stabilizer capacity 1.0 KVA to 5.0 KVA, complete all as specified and as directed by Engineer-In-Charge.
(e) Printed Circuit Board with 15 Volts IC, with internal wiring, suitable for voltage stabilizer capacity 1.0 KVA to 2.0 KVA, complete all as specified and as directed by Engineer-In-Charge.
(f) Printed Circuit Board with 24 Volts IC, with internal wiring, suitable for voltage stabilizer capacity 3.0 KVA to 5.0 KVA, complete all as specified and as directed by Engineer-In-Charge.
(g) Trigger transformer (control step down transformer), 24 Volts, 260 Ohms, suitable for voltage stabilizer, complete all as specified and as directed by Engineer-In-Charge.
(h) Trigger transformer (control step down transformer), 18 Volts, 260 Ohms, suitable for voltage stabilizer, complete all as specified and as directed by Engineer-In-Charge.
Rewinding of main transformer of voltage stabilizer capacity 0.50 KVA, single phase, with super enameled copper winding wire of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge Note: Rewinding of transformer shall have same number of turns of winding wire and with matching to manufacturer design.
Rewinding of main transformer of voltage stabilizer capacity 1.0 KVA, single phase, with super enameled copper winding wire of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge Note: Rewinding of transformer shall have same number of turns of winding wire and with matching to manufacturer design.
Rewinding of main transformer of voltage stabilizer capacity 2.0 KVA, single phase, with super enameled copper winding wire of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge Note: Rewinding of transformer shall have same number of turns of winding wire and with matching to manufacturer design.
Rewinding of main transformer of voltage stabilizer capacity 4.0 KVA, single phase, with super enameled copper winding wire of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge Note: Rewinding of transformer shall have same number of turns of winding wire and with matching to manufacturer design.
Rewinding of main transformer of voltage stabilizer capacity 5.0 KVA, single phase, with super enameled copper winding wire of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge Note: Rewinding of transformer shall have same number of turns of winding wire and with matching to manufacturer design.
Taking down existing desert cooler of any capacity, mounting in any locations and transporting to MES store yard/ workshop for carrying out necessary repairs, servicing, oiling/ lubricating, cleaning the water tank, motor, blades and testing, return the same after carrying out necessary repair work installation at site or other location, including repairs of defective cable connections and making connections of indicating lamps, PVC water pipes and elbow etc, complete all as specified and as directed by Engineer-In-Charge. Note: (i) Spare parts shall be measured and paid separately under respective items of BOQ but cost of transportation to workshop and back to site, repairs shall be deemed included in quoted rate. (ii) Cost of minor spare parts such as PVC elbows, flexible pipes, lubricants, rubber pads and wire mesh shall be deemed included in quoted rate.
Supply only following new spare parts required to replacement for repairs of desert cooler (capacity as mentioned) :- (a) Fan motor, AC operated, single phase, three wires, capacity 1/7 HP, 240 volts suitable for desert cooler and making necessary electric connection and fixing mild steel arms, complete all as specified and as directed by Engineer-In-Charge.
(c) Submersible water pump (tullu pump), AC operated, single phase, capacity 1/20 HP, 240 volts suitable for desert cooler and making necessary connection to power supply including flexible PVC tubing of required size, complete all as specified and as directed by Engineer-In-Charge.
(d) Wooden wool/ grass pads for three sides including binding with GI wire tightly, for desert cooler of any specifications, complete all as specified and as directed by Engineer-In-Charge.
(e) Fan blade (Set of three), mild steel, existing size, with fixing screws with motor, suitable for dessert cooler, complete all as specified and as directed by Engineer-In-Charge.
(f) Mild steel wire mesh, made with 2.0mm dia gi wire powder coated paint, suitable for fixing wood wool pads, for desert cooler of any descriptions, complete all as specified and as directed by Engineer-In-Charge.
(g) Mild steel side, back grill including louvers fins, powder coated paint, suitable for fixing wood wool pads, for desert cooler of any descriptions, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of ball valves with new ball valve, PVC, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 15mm bore pipe, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of old unserviceable/ damaged PVC connections with new PVC connections 15mm size, length 600mm with PTMT nuts at both ends, for inlet water supply, complete all as specified and directed by Engineer-In-Charge.
S&F in replacement of old unserviceable/ damaged capacitor with new capacitor, capacity 4.0mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of old unserviceable/ damaged capacitor with new capacitor, capacity 10.0mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of old unserviceable/ damaged capacitor with new capacitor, 36mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of old unserviceable/ damaged capacitor with new capacitor, 45mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of old unserviceable/ damaged starting capacitor with new starting capacitor, 40/ 60mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of old unserviceable/ damaged starting capacitor with new starting capacitor, 100/ 120mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
Preparation of old painted surfaces of desert cooler metallic body by scrapping old paint with emery/ sand paper and spray painting with one coat of red oxide on internal surfaces and one coat of synthetic enamel paint on external surfaces in colour as approved and writing MES No. on body of dessert cooler, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of Sub main wiring for circuits/ submain wiring alongwith earth wire with two run of 10.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 6.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories, concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications incl taking down old sub main, complete all as specified and as directed by Engineer-In-Charge. Note: Two runs of 10.0 sqmm copper wires and one run of 6.0 Sqmm copper wires including PVC conduit shall be measured as one unit.
S&F in replacement of Sub main wiring for circuits/ submain wiring alongwith earth wire with two run of 4.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 4.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories, concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications incl taking down old sub main, complete all as specified and as directed by Engineer-In-Charge. Note: Three runs of 4.0 Sqmm copper wires including PVC conduit shall be measured as one unit.
S&F in replacement of old unserviceable/ damaged MCCB with new MCCB, Three pole, 415 Volts, adjustable thermal and adjustable magnetic setting, 100 Amps with breaking capacity 16 KA, having indicating lamp, Ics=100% and Icu as per IEC 60947-2, complete all as specified and as directed. Make: Schneider cat part No- C11E3TM100B or equivalent in L&T/ Legrand/ ABB/ Siemens.
S&F in replacement of Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 8-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of old unserviceable MCB with new MCB, Single pole and Neutral, 40 Amps, 240 Volts, having breaking capacity of 10 KA, ‘C’ series, conforming to IS/IEC: 60898, complete all as specified and as directed by Engineer-In-charge.
S&F in replacement of MCB, single pole, 6 to 32 Amps, 240 Volts, 50 Hz, including necessary incoming and out going electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of, 1100 Volts grade, heavy duty, multi-stranded cable, PVC insulated aluminium conductor, multi-stranded, cross sectional area 10.0 Sqmm, 2-core, served with inner sheathing of PVC tape and overall PVC sheathed in service connections complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of PVC insulated FRLS flexible cable with PVC insulated, sheathed, multi-stranded copper conductor 1100 volts grade, size 4.0 Sqmm, 3-core for connection, complete all as specified and as directed by Engineer-In-charge.
S&F in replacement of PVC insulated FRLS flexible cable with PVC insulated, sheathed, multi-stranded copper conductor 1100 volts grade, size 2.50 Sqmm, 3-core for connection, complete all as specified and as directed by Engineer-In-charge.
S&F in replacement of Sheet metal enclosures with socket plug top and MCB suitable for single pole and neutral including a two pin and earth plug and socket complete with one single pole MCB, single pole, 20 Amps, 240 Volts, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of plug top with new plug top, 15 Amps, 3-pin, 240 volts, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of plug top, 5 Amps, 3-pin, 240 volts, complete all as specified and as directed by Engineer-In-Charge.
Material and labour in replacement of PVC insulated flat twin core aluminium stranded cable of size 4 sqmm all as specified and directed.
Material and labour in replacement of PVC insulated flat twin core aluminium stranded cable of size 6 sqmm all as specified and directed.
Material and labour in replacement of PVC insulated flat twin core aluminium stranded cable of size 10 sqmm all as specified and directed.
Material and labour in replacement of PVC insulated flat twin core aluminium stranded cable of size 16 sqmm all as specified and directed.
SPECIAL NOTE FOR AC, WATER COOLER AND CEILING FAN, EXHAUST FAN REPAIRS : The contractor will submit a scanned copy of Memorandum of under standing from OEMs ( or authorized dealers) for the respective E/M equipments. The details of OEMs are as under:- (a) AIR CONDITIONER (i) HITACHI (ii) BLUE STAR (iii) VOLTAS (iv) DAIKEN (b) FREEZER/DEEP FREEZER/REFRIGERATOR (i) LG (ii) SAMSUNG (iii) VOLTAS (C) EXHAUST FANN & CEILING FAN (i) BAJAJ (ii) CROMPTON (iii) HAVELLS (iv) ORIENT (D) SERVO VOLTAGE STABLIZER (I) VINITEK (II) ELECTRIC FIELD (III) V-GUARD
Amount of Schedule of credit of for Rs 2,94,332.00 shall be deducted from quoted amount.
M/S Chib Engineers
M/S SAHNI CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .