Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.4 LAccepted-AOC 1 NEAR AKBARIYA MASJID WIMBERLYGUNJ SOUTH ANDAMAN ANDAMAN NICOBAR 744206 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744206 | L1 | Accepted-AOC Accepted being lowest bidder | |
| 2 | L2₹42.6 L+₹61,100 (1.46%)Rejected-Finance GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L2 | Rejected-Finance Rejected being not lowest bidder | |
| 3 | L3₹42.7 L+₹69,700 (1.66%)Rejected-Finance | L3 | Rejected-Finance Rejected being not lowest bidder | |
| 4 | L4₹44.3 L+₹2.4 L (5.63%)Rejected-Finance | L4 | Rejected-Finance Rejected being not lowest bidder |
Tender Value
₹47.1 L
EMD Value
₹94,200
Closing Date
7 Mar 2022, 6:00 pmClosed
CWE KIRKEE
Headquarters CWE Kirkee, Military Engineer Services, Range Hills Road, Kirkee, Pune-411003
REPAIR/MAINT OF OVERHEAD CONDUCTOR INCLUDING REPAIR TO PANEL AND ALLIED WORKS UNDER AGE E/M-I IN GE (C) KIRKEE
2022_MES_506724_1
CWE/KKE/TOKEN-55 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KIRKEE
As per tender
5 documents required · 5 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹94,200
Yes
12 Apr 2022
8 Feb 2022
9 Mar 2022
8 Feb 2022
7 Mar 2022
23 Feb 2022
9 Feb 2022 - 16 Feb 2022
Amount
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying of pipe and getting out in soft/loose soil. complete all as specified and directed by Engr-in-Charge
All as per item No. 1 above but depth exceeding 1.5 m and not exceeding 3 m for hard/dense soil complete all as specified and directed by Engr-in-Charge
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick. complete all as specified and directed by Engr-in-Charge
Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point. complete all as specified and directed by Engr-in-Charge
M&L PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation for filling in mass concrete for foundation of Pole, Transformer, Panel board, stay, post top lantern, repairs to road cutting, drain, path etc complete all as specified and directed by Engr-in-Charge
M&L PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping of pole / reconstruction old damaged copings etc, including necessary form work complete all as specified and directed by Engr-in-Charge
M&L for sand cousioning for UG cable/ at cable trenches inside substation building complete all as specified and directed by Engr-in-Charge
M&L for old size brick Class 'B' protection for Under ground cable complete all as specified and directed by Engr-in-charge.
Dismantling/ taking out carefully old/unserviceable UG cable any type, any size from trenches/poles/ducts/LT panels after dismentling ends from OH conductors/MCCBs/joint boxes for relaying/refixing or carrying to store for Sch of Credit. complete all as specified and directed by Engr-in-Charge
Materisl and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 50 sqmm 3.5 core with required aluminium cable lugs, heat shrink joints, Colour code heat shrink sleeves at both cable ends all as specified and directed. Note: (i) GI tubing required new will be measured and paid separately under respective item of this schedule. complete all as specified and directed by Engr-in-Charge
All as per item No. 10 above but 70sqmm 3.5 core complete all as specified and directed by Engr-in-Charge
All as per item No. 10 above but 95sqmm 3.5 core complete all as specified and directed by Engr-in-Charge
Dismentling taking out broken/worn out steel pole of 8.5 to 9.0 mtr long and kepping aside for refixing or carrying to store for credit. complete all as specified and directed by Engr-in-Charge
Supply & install erect in true vertical position steel tubular swaged welded poles complete with MS base plate of 6mm thick of size 450mm x 450mm final taper plug pole cap bolt nut and screwed, pole made out of ERW MS tubing confirming to IS 2713 Part(I & II) of 9.0 mtr long, type 410 SP-55 including drilling of holes of required size and nos for fixing of cross arms bracing support / taking out of cables etc with inbuilt junction box for 3 phase 4 wire AC supply and painting with one coat ofred oxide primer and two coat of aluminum paint for exposed surface and two coat of black bituminous paint for the portion embeded in concerete complete all as specified and as directed. (Note : Excavation, earth work & PCC shall be measured and paid separately).
Labour only for re-fixing of steel tubular swaged pole complete with cast iron base plate , painted internally with a coat of bituminous paint and externally one primer coat, one under coat and one finishing coat of aluminium paint as specified type (9 mtr long). complete all as specified and directed by Engr-in-Charge
Dismantling and taking down old/unsv cross arms, bracing, supports etc complete for reuse at site or carrying to store for sch of credit complete all as specified and directed by Engr-in-Charge
Supply and fixing cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paints complete all as specified and directed.
Dismantling and taking down old/unsv ACSR conductor any size complete for reuse at site or carrying to store for Sch of Credit all complete all as specified and directed by Engr-in-Charge
S&F ACSR conductor including jointing with existing conductor and straining on LT pole and proper fastening to pin/shackle insulators with aluminium binding wires and required jumpering connection complete all as specified and directed by Engr-in-Charge
Dismantling and taking down old/unsv insulator of any type any size from pole/stay for reuse at site or carrying to store for sch of credit complete all as specified and directed.
S&F pin type, porcelain, vitreous, brown, including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, 100mm height and 65 mm dia for 1100 volts grade complete all as specified and directed by Engr-in-Charge
S&F shackle type,porcelian vitreous white, brown or green insulator including galvanised mild steel straps , washers, insulators bolts ,washer and nuts of size 100 mm height and 115 mm dia for 1100 Volts grade complete all as specified and directed by Engr-in-Charge
S&F Loop type insulator, porcelian vitreous brown of size 65x90mm and clearence hole 16mm complete all as specified and directed by Engr-in-Charge
M&L for Stay assy using 16mm dia galvanised rod complete all as shown in electrical plate No 1 of SSR Part I incl dismentling unsv one complete all as specified and directed by Engr-in-Charge. Note:-Clamps, loop insulator, earth work, PCC measured separately)
S&F for stay wire using galvanised steel strand of 7/3.15mm complete with necessary binding including dismentling taking down unserviceable one complete all as specified and directed by Engr-in-Charge
S&F cradle hexagonal /rectangular fabricated with galvanised steel wire not less than 4mm dia on pole incl dismentling taking out unsv cradle guard complete all as specified and directed by Engr-in-Charge
S&F earth continuity wire using GI wire not less than 4mm dia on pole including dismentling taking out unsv GI wire complete all as specified and directed by Engr-in-Charge
M & L for Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 3 mtr long buried directly and vertically in ground with top edge at ground level after making bore hole of size not less than 300 mm dia and 3.0 Mtr long using suitable mechanical drilling rig (for drilling near the specified location), connected with galvanised steel earthing lead of 25x4 mm all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2with pit cover, funnel, wiremesh, 32 mm dia light grade GI tubing for protection of GI strip 25x4mm, charcoal and salt in alternate 150mm thick layers around GI earth pipe, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion. complete all as specified and directed by Engr-in-Charge
M&L for restraining of overhead ACSR conductor of any size of 4 wire on pole after disconnecting all jumpering connection & binding of insulators and redoing all jumpering connection and insulator binding with aluminium conductor providing required T&P complete all as specified and directed by Engr-in-Charge.
M&L for restraining of ACSR conductor of any size of 2 wire on pole after disconnecting all jumpering connection & binding of insulators and redoing all jumpering connection and insulator binding with aluminium conductor providing required T&P complete all as specified and directed by Engr-in-Charge
M&L for restraining of GI Cradle guard hexagonal/rectangular of any size on pole after disconnecting all binding on cross arms and redoing all bindings providing required T&P complete all as specified and directed by Engr-in-Charge
M&L for restraining of GI wire of any size on pole after disconnecting all binding on cross arms and redoing all bindings providing required T&P complete all as specified and directed by Engr-in-Charge
Cutting/Trimming of tree branches arround 3.00 mtr distance from conductors of HT over head line of span up to 50 meters including removing of creepers etc frompoles complete all as specified and directed by Engr-in-Charge
Cutting/Trimming of tree branches arround 3.00 mtr distance from conductors of LT over head line of span up to 40 meters including removing of creepers/vegitation etc from poles complete all as specified and directed by Engr-in-Charge
Painting of steel pole any type up to 7.5 mtr height above ground level including cross arms,clamps,stay clamps etc with two coats of aluminium paint after surface preparation complete all as specified and directed by Engr-in-Charge
Painting of steel pole any type up to 9.5 mtr height above ground level including cross arms,clamps,stay clamps etc with two coats of aluminium paint after surface preparation complete all as specified and directed by Engr-in-Charge
Numbering of HT/LT poles serially with letter/number size width and height up to 40 mm in situ with black paint on white back ground complete all as specified and directed by Engr-in-Charge
S&F 1100 volts grade heavy duty flat twin core cable PVC insulated with stranded aluminium conductor of size 2.5 sqmm and overall PVC sheathed in service connections from OH conductor to building incl dismentling taking down unserviceable one complete all as specified and directed by Engr-in-Charge
S&F 1100 volts grade heavy duty flat twin core cable PVC insulated with stranded aluminium conductor of size 4 sqmm and overall PVC sheathed in service connections including dismentling taking down unserviceable one complete all as specified and directed by Engr-in-Charge
S&F 1100 volts grade heavy duty flat twin core cable PVC insulated with stranded aluminium conductor of size 6 sqmm and overall PVC sheathed in service connections incl dismentling taking down unserviceable one complete all as specified and directed by Engr-in-Charge
S&F 1100 volts grade heavy duty flat twin core cable PVC insulated with stranded aluminium conductor of size 10 sqmm and overall PVC sheathed in service connections from OH conductor to building incl dismentling taking down unserviceable one complete all as specified and directed by Engr-in-Charge
S&F jumper connections of length up to 1.50 mtr with existing size and guage of ACSR, binding with existing conductors for LT OH lines complete all as specified and directed by Engr-in-Charge
M & L for Danger notice plate of 1.6mm thick MS sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in singal red colour and fixed with MS clamps, bolts and nuts of approved size, for LT 1100 volts, 20x15 cm size complete all as specified and directed by Engr-in-Charge
Repair to any type of LT panel with cutting necessary worn out portion of MS sheet, angle iron and providing MS sheet of 2mm, MS angle iron of existing size and hinges to broken door etc fixed with electric arc welding, providing external locking arrangement after taking proper electric shutdown. complete all as specified and directed by Engr-in-Charge (Note: Material such as MS sheet, angle iron, hinges measured separately as supply only here-in-after)
Repair to any type of LT feeder pillar with cutting necessary worn out portion of MS sheet, angle iron and providing MS sheet of 2mm, MS angle iron of existing size and hinges to broken door etc fixed with electric arc welding, providing external locking arrangement and painting with one coat of red oxide to effected area complete after taking proper electric shutdown. complete all as specified and directed by Engr-in-Charge (Note: Material such as MS sheet, angle iron, hinges measured separately as supply only here-in-after)
Supply only MS angle iron Fe 410-W (grade E-250 quality- A) of any size/MS sheet of any thickness /MS hinges (With ref to item No- 44 & 45 complete all as specified and directed by Engr-in-Charge).
S&F PVC line seperator suitable for 4 conductors OH Line 1100 volts grade. complete all as specified and directed by Engr-in-Charge
S&F PVC line seperator suitable for 2 conductors OH Line 1100 volts grade. complete all as specified and directed by Engr-in-Charge
S&F in repalcement of outdoor feeder pillar box fabricated from factory of overall size 750 mm (L) x 400 mm (b) x 1500 mm (H) made with 3 mm thick CRCA sheet with hinged door front and rear locking arragements for each cabinet, including painting with super enmaled paint of two coat over a coat of red oxide primer and black at bottom after antirust treatment of CRCA sheet top cabinet with incoming 3 phase & neutral and bus bar rating current 1.5 times with IP 65 protection. The feeder pillar shall be provided with two Nos of earth terminal hinged door, front and rear door with locking arrgagement suitable for 1100 Volts grade, 3 Phase, 415 Volts, 50 Cycles, AC suppply, LT danger notice plate front and rear, The panel shall be embedded 300 mm below ground level in PCC 1:2:4 Type B-1 using 20 mm grade stone aggregate, 500 mm above ground level complete all as directed by Engr-in- Charge with follwoings :- Incomer MCCB FP 200 Amp -01
ONKAR ELECTRIC AND GENERAL STORE
M/S. OM ENTERPRISES
M/s Harshal Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .