Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹55.5 LAccepted-AOC | ₹55.5 L | L1 | Accepted-AOC ACCEPT |
| 2 | Rejected-Technical | - | - | Rejected-Technical Technically Not Qualified |
| Sl No | Description | Qty | Unit | S RAJU L1 |
|---|---|---|---|---|
| 1.00 | 1.Providing cast in situ cement concrete 1:11/2 :3 using 20 mm size HBBG jelly for 23cm dia pile including cost of materials labour,hire charges for machinery for earthwork for forming 23cm dia bore hole to the required depth before concreting excluding cost of steel reinforcement | 4 | m | 2,509 ₹10,036 Lowest |
| 2.00 | 2.Supplying and fabricating and placing in postion of RTS Bar reinforcement to all RCC Works as per the design given including cost of steel and binding wire also all floors. | 45 | qtl | 9,321.6 ₹4,19,472 Lowest |
| 3.00 | 3.Earthwork excavating and depositing on bank with initial lead of 10m & initial lift of 2m in Hard stiff clay, stiff black cotton, hard red earth, shales, murram,gravel,stoney earth and earth mixed with small size boulders | 97 | m3 | 181 ₹17,557 Lowest |
| 4.00 | 4.Plain Cement Concrete 1:4:8 using 40mm size ISS HBG metal including cost and conveyance of all materials etc., complete as per standard specification | 3 | m3 | 5,590 ₹16,770 Lowest |
| 5.00 | 5.Supplying and erecting for shuttering, including necessary supports for Plinthbeams, using mild steel sheets of size 90cmx60cm and 10gauge, stiffened with mild steel angle of size 25mmx25mmx3mm for boarding, supported by silver oak joists of size 10x6.5cm,spaced
at about 90cm centre and supported by casurina props of 10cm to13cm dia spaced at 75cm
centre to centre complete, complying with standard specifications and as directed etc. | 34 | m2 | 1,112 ₹37,808 Lowest |
| 6.00 | 6.Brick work in cement mortar 1:5 mix using Fly Ash bricks of 230x110x70mm including cost of materials and labour charges etc., as per standard specification | 24 | m3 | 6,840.76 ₹1,64,178.24 Lowest |
| 7.00 | 7.Reinforced Cement concrete 1:1.5:3 using 20mm hand broken and broken granite stone for all RCC items of works excluding centering shuttering and cost of reinforcement but including curing etc.,complete | 53 | m3 | 9,373 ₹4,96,769 Lowest |
| 8.00 | 8.Plastering with cm 1:5 12mm tk for all external and internal wall surface etc complete | 323 | m2 | 292 ₹94,316 Lowest |
| 9.00 | 9.Supply and Filling with well gravel layer by layer inlcuding consolidation charges etc complete | 3 | m3 | 504 ₹1,512 Lowest |
| 10.00 | 10.Supplying and erecting centering for sides soffits including supports and strutting upto 3.29m high for slab using mild steel sheets of size 90cmx60cm and 10gauge, stiffened with mild steel angle of size25mmx25mmx3mm for boarding, supported by silver oak joists of size 10x6.5cm,spaced at about 90cm centre and supported by casurina props of 10cm to13cm dia spaced at 75cm centre to centre complete, complying with standard specifications and as directed etc. | 71 | m2 | 1,290 ₹91,590 Lowest |
Tender Value
₹66.5 L
EMD Value
₹66,500
Closing Date
25 Dec 2025, 3:00 pmClosed
The Commissioner, Coimbatore Corporation
Coimbatore Corporation, Main Office, Big bazaar street, Town hall, Coimbatore-1
Construction of GENSET Room, Effluent treatment plant Room, RO plant Room and Supply, delivery and installation of Diesel Generator Set, Effluent treatment plant , RO plant machine to the Additional Medical Facility Centre at Seethalakshmi Urban Pri
2025_MAWS_634386_5
e62/2025-Two Cover
Open Tender
Civil Works
Works
150 days
Coimbatore corporation
AS PER TENDER DOCUMENT
5 documents required · 5 mandatory
₹0
₹66,500
27 Mar 2026
19 Dec 2025
26 Dec 2025
19 Dec 2025
25 Dec 2025
19 Dec 2025
Amount
1.Providing cast in situ cement concrete 1:11/2 :3 using 20 mm size HBBG jelly for 23cm dia pile including cost of materials labour,hire charges for machinery for earthwork for forming 23cm dia bore hole to the required depth before concreting excluding cost of steel reinforcement
2.Supplying and fabricating and placing in postion of RTS Bar reinforcement to all RCC Works as per the design given including cost of steel and binding wire also all floors.
3.Earthwork excavating and depositing on bank with initial lead of 10m & initial lift of 2m in Hard stiff clay, stiff black cotton, hard red earth, shales, murram,gravel,stoney earth and earth mixed with small size boulders
4.Plain Cement Concrete 1:4:8 using 40mm size ISS HBG metal including cost and conveyance of all materials etc., complete as per standard specification
5.Supplying and erecting for shuttering, including necessary supports for Plinthbeams, using mild steel sheets of size 90cmx60cm and 10gauge, stiffened with mild steel angle of size 25mmx25mmx3mm for boarding, supported by silver oak joists of size 10x6.5cm,spaced at about 90cm centre and supported by casurina props of 10cm to13cm dia spaced at 75cm centre to centre complete, complying with standard specifications and as directed etc.
6.Brick work in cement mortar 1:5 mix using Fly Ash bricks of 230x110x70mm including cost of materials and labour charges etc., as per standard specification
7.Reinforced Cement concrete 1:1.5:3 using 20mm hand broken and broken granite stone for all RCC items of works excluding centering shuttering and cost of reinforcement but including curing etc.,complete
8.Plastering with cm 1:5 12mm tk for all external and internal wall surface etc complete
9.Supply and Filling with well gravel layer by layer inlcuding consolidation charges etc complete
10.Supplying and erecting centering for sides soffits including supports and strutting upto 3.29m high for slab using mild steel sheets of size 90cmx60cm and 10gauge, stiffened with mild steel angle of size25mmx25mmx3mm for boarding, supported by silver oak joists of size 10x6.5cm,spaced at about 90cm centre and supported by casurina props of 10cm to13cm dia spaced at 75cm centre to centre complete, complying with standard specifications and as directed etc.
11. Supply and fixing of 710x710mm FRP cover with frame etc complete
12.Supply and fixing of Ms pipes etc complete
13. Roofing with Pre painted Galavalume sheet 0.47mm thick with necessary bolt and nuts and washers including allmaterials and labour charges etc complete
14.Supply and fixing of weld mesh etc complte
15.Supply and Laying of 3 1/2 x 35 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.45 metre and refilling the earth to make good.
16.Supply and fixing of 100A TPN sheet double break switch with HRC fuse and neutral on suitable angle iron frame work with MS cable entry boxes and with PWD earthing
17.Pcc 1:2:4 mix using 20mm size ISS gauge HBBG metal including mixing, laying, consolidating, curing, cost and conveyance of all materials to site and all labour charges etc.,complete as per standard specification
18.Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate continuous earth wire connection of 1.5 sq.mm copper wire for Open PVC Light point / fan point (for electronic regulator) ( 4 points / Coil)
19.Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC Rigid pipe on wall and ceiling and switch drop portion PVC rigid pipe concealed in wall with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 6A one way module switch and 1 no. 6A 3/2 pin module socket with module front plate with painting of Suitable colour with continuous earth wire connection of 1.5 sq.mm copper wire for Open PVC Plug point
20.Wiring with 2 x 4 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with suitable Module Plastic surface mounting switch box on wall with 1 no. 16A one way module switch and 1 no. 16A 3/2 pin module socket with module front plate with painting of Suitable colour with continuous earth wire connection of 4 sq.mm copper wire for Open PVC pipe power Plug point
21.Supply and fixing of 20W Led tube light fitting etc complete
22.supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting .
23.Supply and delivery and installation of Diesel Generator Set with acoustic enclosure conforming to CPCB IV+ Norms and BIS Specifications etc complete
24.Designing, fabrication, powder coating, assembling , wiring, testing and supply of the ATS panel with stand of size 56"x30"x8" including HRC fuse link ,bus bar etc complete
25.Supply,delivery and erection and commissioning of Effluent treatment plant 1.0 LKD inlcuding Effluent transfer pump 100 LPH capacity with 10m head , lime dosing system, Ferous sulphate dosing system, poly electrolyte dosing system, flash mixer, primary settler tank , Ph correction dosing system, fliter feed pumps, etc complete
26.Dismantling the existing damaged cement concrete as per the direction of departmental officer
27.providing & fixing UPVC GUTTER of the following dia with necessary Upvc Runner Drop,Elbow drop,Stop End,Stop End Drop Upvc Bracket,GI clamp etc.,complete complying with standard specification. The size of The Gutter is 5m length, 220mm width,160mm depth,2.5mm thickness, holding capacity 20ltr/Mtr and pipe is to be fixed by means of Upvc bracket and clamps at the centre of pipes to be fixed.
28.Supplyand fixing of mild steel door usingall round "L" angle 25 X 25 X 6mm thick, cross bracing 20 X 6mm M.S.Flatwithnecessary locking arrangements including cost and conveyance etc.,
29. Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work
30.Supply and Laying of 4x10 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.45 metre and refilling the earth to make good.
31.Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire etc completee
32.Supply and Run of 4 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection by 4 sq.mm. PVC insulated SC unsheathed FRLS copper wire etc
33.Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board ith double door (metal) with 1 no. 40A DP MCB Isolator as incoming and 6 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only
34.Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 40A DP MCB Isolator as incoming and 10 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only
35.Supply and fixing of 100W Led Light fitting etc complete
36.supply and fixing of 1200mm (48") sweep AC ceiling fan 5 star rated complete ( Higher end) with 2 module 100W fan step regulator (Higher end) with 300mm down rod with fan clamp with side plates and cross arm of size 300/450mm etc
37.Supply and delivery of Ro based water treatment plant 1000 LPH as per direction of departmental officers
38.Supply and delivery of Dialysis pump with tank and pipe line and othe accessories etc complete
39.Erection and commissioning charges for Ro based water treatment plant and dialysis pump etc
40.Plain Cement concrete 1:1.5:3 using 20mm hand broken and broken granite stone for all PCC items of works excluding centering shuttering and cost of reinforcement but including curing etc.,complete
41.Providing two legged scaffolding using 15cmdiameter blue-gumprops or casurina props or best quality bamboo props of 4m overall length the distance between the two rows being 2m in both the rows with two horizontal props with 0.50m overlap on either side and braces at 2m c/c including longitudinal and transverse middle braces to step up and providing a platform with countrywood planks of 40mm thick and 1m width etc complete from using coir and nails etc complete.
42.Supplying and erecting centering for side and soffits including necessary supports and strutting upto 3.29m high for plane surfaces such as sides labs of RCC boxing and similar vertical RCC slabs, FACIA, Dropetc., in all floor with all cross bracing using mild steel sheets of size of 90cmX60cm and BG10 stiffened with welded mild steel angles of size 25X25X3mm for boarding laid over countrywood joists of size 10cmx 6.5cmspaced at about 90cmC/C and supported by casurina props of 10cm to 13cm diaspaced at 75cmC/C etc.,completed as directed. Sl.No.123B Part-II
43. Supplying and erecting centering for sides soffits including supports and strutting upto 3.29m high for plain surface such as rectangular column top and bottom slabs of boxing, sill, slabs, sunshade etc., in all floors using mild steels labs of sizes 90cmx60cm and BG10 stiffened withweldedmild steel angles of size 25X25x3mmfor boarding laidover countrywood joists of size10cmX 6.5cm spaced at about 90cmC/C and supported by casurina props of 10cm to13cm dia spaced at 75cm C/C etc complete
44.Special Ceiling Plastering for RC slabs andbeamswith cementmortar 1:3mix 10mmthick including hacking etc., complete 10 m2
45.Flooring with 20mm thick cement concrete 1:3 mix (no sand to be used) using 3mm to 10mm ISS gauge HBBG chips and the surface rubbed hard and finished smooth with neat cement Ellise pattern surface
46.Flooring with Vetrified flooring tiles of size 600 x 600 x 8mm of approved colour and quality of rquired size laid in cement mortar 1:3 mix 20mm thick and pointing with the same mortar complete and finish very neatly etc complete
47.Cladding the vertical wall with Pre-polished Granite slabs (16mm to 18mm thick) and best quality free from all defects and set in CM 1:2 for 10mm thick.etc., complete as directed by the Engineer - in - charge
48.Supply and clarnping of 4 x 6 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps
49.Supply and fixing of bulk head fitting etc complete
50.Earthing arrangements with GI Earth Plate including charcoal and salt with necessary excavation in all soils and to full depth as may be required and masonry work, re-filling the sides of foundation with excavated earth as per the standard specification and as directed by the Departmental Officers.
51.Providing and Applying of Solar reflective Paint, acrylic polymer based elastometric water proofing coating having Solar Reflective Index more than 90 % as per ASTM E 903, specific Gravity of 1.30+/-0.10. For Existing Surface: The Surface Preparation including Jet wash , the Cracks are filled wherever required below 3mm of crack and application of three coats of paint to form 1mm thickness
52.Painting the Wall Two Coats with approved colour Emulsion paint two coats over prime coat for Wall surfaces etc., complete complying with standard specifications and as directed by the departmental officers.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.52 MB
ITB.pdf
Additional Documents • 0.19 MB
buildingSWD.pdf
Tender Documents • 0.96 MB
BOQ_759140.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .