Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.5 LAccepted-AOC 205 IIND PHASE INDUSTRIAL AREA BARMER 344001 | BARMER | BARMER | RAJASTHAN | 344001 | L1 | Accepted-AOC QUOTED RATE IS REASONABLE | |
| 2 | L2₹12.9 L+₹97,906 (8.24%)Rejected-Finance NEAR RAILWAY STATION UTARLAI BARMER RAJASTHAN PIN 344001 | BARMER | RAJASTHAN | 344001 | L2 | Rejected-Finance higher rate quoted by bidder | |
| 3 | L3₹13.5 L+₹1.6 L (13.2%)Rejected-Finance SPECIAL 1 INDUSTRIAL ESTATE NEW POWER HOUSE ROAD JODHPUR 342003 | JODHPUR | RAJASTHAN | 342003 | L3 | Rejected-Finance higher rate quoted by bidder |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
30 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF JAISALMER
HQ CWE AF JAISALMER
REPAIR AND MAINT OF GANTRIES AND ALLIED WORKS AT AIR FORCE STATION UTARLAI
2023_MES_572638_1
80221/E8
Open Tender
Miscellaneous Works
Item Rate
330 days
GE AF UTARLAI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF UTARLAI
₹30,000
Yes
23 Feb 2023
2 Jan 2023
1 Feb 2023
2 Jan 2023
30 Jan 2023
17 Jan 2023
Amount
Comprehensive maintenance of installed Crane Gantries (EOT and HOT) in reliable, safe and efficient operation condition through MOU with OEM by regularly examining, lubricating and ajusting the equipments and carry out planned maintenance in systematic and controlled manner for Gantriesincluding inspection, periodical checks and servicing of EOT Cranes 02 Ton (14 Nos), 05 Ton (02 Nos) and HOT Cranes (4 Nos) inside the Technical Area by rectifying the defects observed during servicing of all the moving parts by lubricating them with suitable lubricants, cleaning of external and internal surfaces and refixing and tightening at existing places making it serviceable by replacing the defective parts complete all as directed by Engineer-in-Charge. Make: Johnson (Serial No. LE-6686) Notes :- (i) The above maintenance include complete maintenance of existing Crane Gantries by regularly and systematically examining, adjusting and lubricating as required for smooth and efficient functioning of the equipments/Crane Gantries and maintenance such as servicing/de-calibration, connecting and complete labour required for smooth functioning of Gantries, These aspects shall be deemed to be included in the quoted rates. (ii) The contractor shall attend major breakdown /non functioning of Crane Gantrie immediately on information received from the department. The cost of same shall be deemed to be included in the unit rates qouted by the contractor. (iii) Unless otherwise specified major spare parts shall be measured and paid for separately as "Supply only" in replacement/repairs.Cost of any minor spares required other than specified here in below shall be deemed to have been included in the rate quoted by contractor. (iv) Unless otherwise specified the major spare parts shall of existing make and specifications. (v) Contractor will prominently display his contact/mobile number inside and outside the lift on each lift for call in emergency. (vi) All existing earthings of the Cranes shall be maintained and made fully functional by the contractor to the entire satisfaction of the Engineer-in-Charge. (vii) The repair work shall be carried out through OEM/Accredited agencies/Registered MES contractors or other enlisted contractors in appropriate category of CPWD/Railways/Govt Agencies. MoU duly signed with the OEM or above agencies shall be furnished by the contractor. Contractor will conclude AMC with OEM and copy of the agreement will be submitted to Engineer-in-Charge and GE before commencement of AMC. No payment will be made to contractor without submission of valid AMC agreement. (ix) A calender month comprises of 30 days.
Supply only wheel bearing for EOT cranes (LT) upto 2.0Ton capacity Make: NBC/SKF
Supply only wheel bearing for EOT cranes (LT) upto 5.0 Ton capacity Make: NBC/SKF
Supply only wheel bearing for EOT cranes (CT) upto 2.0 Ton capacity Make: NBC/SKF
Supply only wheel bearing for EOT cranes (CT) upto 5.0 Ton capacity Make: NBC/SKF
Supply only carbon bushes for hoist creep motor as per the existing design, suitable for EOT crane upto 5 tonne capacity of existing make
Supply only MS coupling bolts & nuts as per the existing design and size as directed.
Supply only steel wire rope 10mm dia for EOT crane existing make
Supply only steel wire rope 12mm dia for EOT crane existing make
Supply and refill grease including cleaning of old grease complete all as specified and directed.
Supply and refill gear oil SP 320 for top up upto to required level or only U/s oil complete all as specified and directed.
Supply only gear wheel shaft for crane upto 2.0 Ton capacity, taking down, servicing of gear box, greasing etc and refixing of crane with proper alignment etc, including testing on completion, complete all as directed by Engineer-in-Charge.
Supply only gear wheel shaft for crane upto 5.0 Ton capacity, taking down, servicing of gear box, greasing etc and refixing of crane with proper alignment etc, including testing on completion, complete all as directed by Engineer-in-Charge.
Supply and fix in replacement New Gears, Pinion, Warm Gear, Oil seals, Packings etc forf the cranes of 2 Ton capacity including all other accessories, fixtures, nut, bolts & washers as required for fixing gears, gear oil (Gear oil 320) complete all as specified and directed. (Note :- Gear oil will be measured and paid for seperately under relevent item of BOQ.
Supply only brake shoe suitable for 2 Ton capacity EOT as per existing make, model and sizes complete all as specified and directed. Note :- All brake shoe of complete 2 Ton EOT will be changed in this item
Supply only brake shoe suitable for 5 Ton capacity EOT as per existing make, model and sizes complete all as specified and directed. Note :- All brake shoe of complete 5 Ton EOT will be changed in this item
Supply and refill Transformer Oil for top up in hydraulic brakes of EOTs complete all as specified and directed.
Supply only padestal including padestal bearing of size 32mm complete all as specified and directed.
Supply only padestal including padestal bearing of size 35mm complete all as specified and directed.
S&F in replacement Power Contactor of capacity 25 Amp, 3 pole suitable for EOT crane 2 Tonne capacitycomplete all as specified and directed.
S&F in replacement Power Contactor of capacity 40 Amp, 3 pole suitable for EOT crane 5Tonne capacitycomplete all as specified and directed.
S&F in replacement Thermal Over Load Relay upto 14.5 Amp capacity.
S&F in replacement DSL Collectors of 16 Amp capacity for EOT cranes of existing make complete all as specified and directed
S&F in replacement DSL collectors of 32 Amp capacity for EOT cranes of existing make complete all as specified and directed
S&F in replacement HRC Fuses of 6-15 Amp capacity for EOT cranes complete all as specified and directed. Make: Siemens/L&T/Schneider
S&F in replacement PVC sheathed multistranded flexible copper cable of 3 core 4 Sqmm 1100 Volts grade for EOT crane complete all as specified and directed.
S&F in replacement PVC sheathed multistranded flexible copper cable of 3 core 6 Sqmm 1100 Volts grade for EOT crane complete all as specified and directed.
S&F in replacement sheathed multistranded flexible copper cable of 3 core 10 Sqmm 1100 Volts grade for EOT crane complete all as specified and directed.
S&F in replacement Elelectrical Pendent Push Buttons with NO/NC contacts elements for EOT cranes of any capacity complete all as specified and directed.
M&L for testing of alignment of EOT crane tracks (rails) both sides by putting / adding additional material (filling) by gas cutting & welding the same and making them smooth by grinding for smooth functioning of crane complete all as specified and directed.
M&L for rectification of oil leaking from LT gear box of EOT crane by replacing spares such as oil seals etc for EOT crane, complete all as specified.
M&L for dismantling motors upto 1.5 KW capacity from EOT crane taking down and carry to workshop, rewinding with existing guage of super enamelled copper winding wire of superior quality with proper insulation and bringing back and refixing on crane with proper alignment with gear box etc, including testing on completion, complete all as directed.
M&L for dismantling motors 2 KW to 3.5 KW capacity from EOT crane taking down and carrying to workshop, rewinding with existing guage of super enamelled copper winding wire of superior quality with proper insulation and bringing back and refixing on crane with proper alignment with gear box etc, including testing on completion, complete all as directed.
M&L for dismantling electric magnetic brake coil from crane of any capacity, taking down and carrying to work shop, rewinding with existing guage of super enamelled copper winding wire of superior quality with proper insulation and bringing back and refixing on crane with proper alignment with gear box etc, including testing on completion, complete all as directed..
S&F in replacement Limit Switch for EOT cranes of any type capacity and existing make complete all as specified and directed.
M&L for old damaged limit switch arrangement by providing suitable size limit switch (02 Nos) of approved make and connected accessories for restricting the LT movement, VT movement and CT movement for crane of 5 Ton Capacity including necessary fixing arrangements and fabrication as required at site complete all as specified and directed.
S&F in replacement Iron Cable Carrier (Rollers) complete all as specified and directed.
S&F in replacement Remote Control Unit plastic body suitable for 2 Ton EOT as per existing make and model complete all as specified and directed.
S&F in replacement Remote Control Unit Cast iron body suitable for 2 Ton EOT as per existing make and model complete all as specified and directed.
S&F in replacement Single Phase Preventor as per existing make and model complete all as specified and directed.
S&F in replacement Phase Sequence Corrector as per existing make and model complete all as specified and directed.
S&F in replacement VFD as per existing make and model suitable for 5 Ton EOT complete all as specified and directed.
Carrying out load test for each crane EOT 2 Ton Capacityf once in eleven month on EOT 02 Ton / 05 Ton and HOT cranes inside the Tech Area under 100% load capacity of cranes on hoisting, long travel and cross travel for checking the performance including deflection test with necessary manpower /instruments/necessary internal transportation upto required cranes, complete all as directed by Engineer-in-Charge as under :- Note:(i) Load will be provided at site by the Deptt as to ensure smooth/safe and efficient operation.
Carrying out load test for each crane EOT 5 Ton Capacityf once in eleven month on EOT 02 Ton / 05 Ton and HOT cranes inside the Tech Area under 100% load capacity of cranes on hoisting, long travel and cross travel for checking the performance including deflection test with necessary manpower /instruments/necessary internal transportation upto required cranes, complete all as directed by Engineer-in-Charge as under :- Note:(i) Load will be provided at site by the Deptt as to ensure smooth/safe and efficient operation.
Carrying out load test for each crane HOT 2 Ton Capacityf once in eleven month on EOT 02 Ton / 05 Ton and HOT cranes inside the Tech Area under 100% load capacity of cranes on hoisting, long travel and cross travel for checking the performance including deflection test with necessary manpower /instruments/necessary internal transportation upto required cranes, complete all as directed by Engineer-in-Charge as under :- Note:(i) Load will be provided at site by the Deptt as to ensure smooth/safe and efficient operation.
Excavating in trenches in soft/loose soil n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, for pipes and electric cables etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as speified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. Returning, filling including spreading, leveling watering & well ramming in layers not exc. 25 cm for soft/loose soil complete all as speified and as directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point for soil complete all as speified and as directed.
M&L for providing dry tibba sand in trenches as sand cushioning to underground cable including punning down of sand in layercomplete all as speified and as directed. (Note :- 18 cm punned thickness shall only be reckoned for the purpose of measurement and paymentmeasured and paid).
M& L for 40 to 50 mm thick rough dressed Jodhpur type stone slab 25 to 35 cm in width of 80 cm long laid dry abutting each other for protection to under ground cable complete all as specified and directed.
Supply, lay, joint, test and commission LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured overall PVC sheatehed electric power cable heavy duty with aluminium conductor of size 3.5 core 35 sqmm crosssectional area, 1100 Volts grade, laid in trenches, fixed on wals,roofs and poles, laid in ducts and floors etc complete all as specified and directed. Note : Earth work, sand cushioning, cable protection cover, pipe and joint shall be measured and paid for separately under respective items of BoQ
Supply, lay, joint, test and commission LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured overall PVC sheatehed electric power cable heavy duty with aluminium conductor of size 3.5 core 50 sqmm crosssectional area, 1100 Volts grade, laid in trenches, fixed on wals,roofs and poles, laid in ducts and floors etc complete all as specified and directed. Note : Earth work, sand cushioning, cable protection cover, pipe and joint shall be measured and paid for separately under respective items of BoQ
Supply, lay, joint, test and commission LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured overall PVC sheatehed electric power cable heavy duty with aluminium conductor of size 3.5 core 70 sqmm crosssectional area, 1100 Volts grade, laid in trenches, fixed on wals,roofs and poles, laid in ducts and floors etc complete all as specified and directed. Note : Earth work, sand cushioning, cable protection cover, pipe and joint shall be measured and paid for separately under respective items of BoQ
M/S TANUSHREE CONSTRUCTION COMPANY
INDO CONSTRUCTION
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .