Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.7 CrAccepted-AOC DEEDAR MARKET ROOM NO UB 12 POLICE BAZAR SHILLONG 793001 | EAST KHASI HILLS | MEGHALAYA | 793001 | ₹3.7 Cr Quoted ₹3.8 Cr | L1 | Accepted-AOC Being lowest and reasonable |
| 2 | L2₹3.9 Cr+₹5.3 L (1.39%)Rejected-Finance | ₹3.9 Cr+₹5.3 L (1.39%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹4.0 Cr+₹13.3 L (3.47%)Rejected-Finance C O GUPTA EMPORIUM AR BAZAR HAPPY VALLEY SHILLONG 793 004 | EAST KHASI HILLS | MEGHALAYA | 793004 | ₹4.0 Cr+₹13.3 L (3.47%) | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹4.2 Cr+₹36.1 L (9.40%)Rejected-Finance | ₹4.2 Cr+₹36.1 L (9.40%) | L4 | Rejected-Finance Not being lowest |
| 5 | L5₹4.5 Cr+₹64.1 L (16.7%)Rejected-Finance H M APARTMENT 4C S J ROAD ATHGAON GUWAHATI 781001 | GUWAHATI | KAMRUP METRO | ASSAM | 781001 | ₹4.5 Cr+₹64.1 L (16.7%) | L5 | Rejected-Finance Not being lowest |
Tender Value
₹5.2 Cr
EMD Value
₹5.8 L
Closing Date
15 Sept 2020, 6:00 pmClosed
Chief Engineer Shillong Zone
HQ Chief Engineer Shillong Zone, SE Falls, Shillong-793011
MODERNISATION OF LOGISTIC INSTALLATION OF ADVANCE BASE DEPOT AT GUWAHATI UNDER GE NARANGI
2020_MES_353309_1
CESZ/NAR/11 OF 2020-2021
Open Tender
Civil Works
Item Rate
365 days
NARANGI
As per Tender Documents
2 documents required · 2 mandatory
₹3,000
Yes
GE NARANGI
₹5.8 L
Yes
24 Nov 2020
16 Jun 2020
17 Sept 2020
16 Jun 2020
15 Sept 2020
10 Sept 2020
17 Jun 2020 - 27 Jun 2020
Amount
NOTE (Applicable for all items):- The bidders/contractors are advised to read tender document & all corrigendum/ amendments and General conditions of contracts before entrying/quoting the rates. SCHEDULE 'A' (B/R & E/M WORK)
Surface dressing not exceeding 15 cm deep in soft/loose soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc. or for shafts, wells, cess pits, manholes, pier holes etc. not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out as in soft/loose soil complete all as specified and as directed.
Excavation over areas, not exceeding 1.5m deep and getting out as in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm as in soft/loose soil complete all as specified and as directed.
Removing excavated material (soil) not exceeding 50 m and depositing where directed at a level n. exc. 1.50 m above the starting point complete all as specified and as directed.
Demolition of Brickwork or stone masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
Demolition of Reinforced cement concrete of any description and in any position not otherwise specifically provided for drain cover slab complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
Demolition of Concrete of any description and in any position not otherwise specifically provided complete all as specified and as directed.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed.
M & L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick broken stone or boulder, watered and rammed to a true surface complete all as specified and as directed.
M&L for 20mm thick sand layer as levelling course above hardcore and below polythene for concrete road complete all as specified and as directed.
M&L for black polythene film 200 micron laid over sand layer below PCC of concrete road for laying of concrete complete all as specified and as directed.
M&L for Mild steel round bars 25mm dia 600 mm long @450 c/c with GI shoes at both ends at construction joints of concrete road pavements at every 30 mtr length of concrete road including boring form work as required at site and preformed filler for dowels complete all as specified and as directed.
M&L for Mild steel round bars 20mm dia 600 mm long @600 c/c with GI shoes at both ends along the length of concrete road between two lanes of concrete road at joints of concrete road including boring form work as required at site and preformed filler for dowels complete all as specified and as directed.
M & L for Cement concrete work in pavement/ hardstanding of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less complete all as specified and as directed.
Material & labour for brick work with subclass 'B' bricks, old size, straight or curved on plan exceeding 6 m mean radius built in Cement Mortar 1:6 complete all as specified and as directed
M & L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS: 1161 (latest addition) grade St.-240 complete all as specified and as directed.
M & L for Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
Taking down chowkhats or frames not exc. 1.5 sq. m with shutters (without taking off shutters from the frames) complete all as specified and as directed.
M & L for Steel windows with side hung shutters glazed shutter including projecting type hinges with steel handle and steel peg stay with glazing bars and 12 mm square bar or ground bar of approved design welded to steel window frame dovetailed or welded complete all as specified and as directed.
M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and as directed.
M&L for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates using Fe 410-W (Gde E-250) quality 'A' complete all as specified and as directed.
M&L for Plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases. splices, angle brackets, cleats and other connections using Fe 410-W (Gde E-250) quality 'A' complete all as specified and as directed.
Material & labour for Plain Cement Concrete 1:2:4 type B-2 (Nominal Mix) using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M & L for Pre- painted hot-dip aluminum zinc alloy meltalic coated trapezoidal profile steel sheet 0.50mm thick (Total Coated Thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ150 of an approved colour having yield strength of 550 Mpa as in roof as in roof covering/ cladding to wall, fixed with self tapping screws as specified including necessary scacomplete all as specified and as directed.
M & L for Pre- painted hot-dip aluminum zinc alloy meltalic coated plain steel sheet 0.50mm thick (Total Coated Thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ150 of an approved colour having yield strength of 550 Mpa as in roof as in roof covering/ cladding to wall, fixed with self tapping screws as specified including necessary scacomplete all as specified and as directed. Note:- To be executed for provisions of ridges & hips.
M&L for Fibre glass reinforced translucent corrugated sheeting 2mm thick with two corrugations side lap fixed with coach screw and washer in roof, wall etc. complete all as specified and as directed.
M & L for 1.0 mm thick plain, galvanised, mild steel sheeting, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and as directed.
M&L for Rendering 15 mm in Cement Mortar 1:6 on brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed.
Material & labour for rendering 15 mm in Cement Mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls and applying one coat of alkali resistant primer over a coat of white cement based putty(Make:- birla/ JK), sanding the surfaces till smooth finish is obtained and finally two coats of oil emulsion distemper complete all as specified and as directed.
M&L for preparation of new wall surfaces and applying two coats of cement based paint over a coat of alkali resistant primer complete all as specified and as directed.
S&F Rough cast wired glass, 6.4mm thick and glazing with oil putty in square not exceeding 0.5 Sqm in each pane etc complete all as specified and as directed.
Material and labour for painting two coats of synthetic enamel paint on steel and iron surfaces of any description over 10 cm in width or girth including preparation and one coat of red oxide primer complete all as specified and as directed.
Material and labour for painting two coats of synthetic enamel paint on steel and iron surfaces of any description over but not exceeding 10 cm in width or girth including preparation and one coat of red oxide primer complete all as specified and as directed.
Material and labour for preparation of old painted steel surface exceeding 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
Material & labour for Plain Cement Concrete 1:3:6 type C2 (Nominal Mix) using 40 mm graded stone aggregate as in surface channels and drains including necessary formwork etc complete all as specified and as directed.
Material & labour for precast Reinforced Cement Concete cover slab type 1:2:4 type B-1 (Nominal Mix) using 20 mm graded stone aggregate, set in Cement Mortar (1:4) complete all as specified and directed.
Mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
S&F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') complete all as specified and as directed.
S&F in repairs Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed.
Hacking out old broken glass exceeding 1.50 Sqm (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed.
S&F frosted glass 4.80 mm thick, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and as directed.
Material & labour for 50mm thick Plain Cement Concrete 1:3:6 type C1 (Nominal Mix) using 20 mm graded stone aggregate as in plinth protection complete all as specified and as directed.
Forming Construction joint 30mm deep x 10mm wide filled with sealing compound Grade 'A' complete all as specified and as directed.
Supply and laying of PVC(SWR) pipes 150 mm dia single socketed in any length with rubber ring joints, laid in trench or in floor complete all as specified and as directed.
Supply and fix of PVC(SWR) 150 mm dia bends in any radius fixed in rain water pipe complete all as specified and as directed.
Material & labour for Reinforced Cement Concrete M-25 (Design mix) using 20 mm graded stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns and mass concrete complete all as specified and directed.
Material & labour for Reinforced Cement Concrete M-25 (Design mix) using 20 mm graded stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and as directed.
Material & labour for use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces of concrete complete all as specified and as directed.
M&L for false ceiling with GI frame work for EXPOSED GRID SYSTEM of grid size 600mm x 600mm, GI powder coating at bottom and comprising of GI perimeter wall angle with two equal flanges of 25 mm fixed to surrounding wall / partition using nylon sleeves and screws at 450 mm centre to centre/intermediate channel. Main Tee having 35 mm wide flange and 25 mm high web suspended from the soffit @ 1200 mm centre to centre with level clip with wire of 4 mm dia, Cross Tee - 1200, 0.70 mm thick having 35 mm wide flange and 25 mm high web inserted fixed into the slots of Main Tee @ 600 mm centre to centre to from a grid of 1200 mm x 600 mm, Cross Tee - 600, 0.70 mm thick having 35 mm wide flange and 25 mm high web shall be placed perpendicular to the Cross Tee - 1200 to finally from a grid of 600 mm x 600 mm with and including 6 mm thick high pressure, oceanic pre-primed, self embossed, non asbestos fibre cement decorative board, water, termite and fire resistant for insulation and acoustic purpose to be placed in the grid system duly suspended with 2 to 3 mm dia GI wire hangers fixed with steel dash through fastners from purlins with butterfly clips, hold down clips, with provision of high fixures, air conditioning, diffusre and ducts, sprinkler, smoke detector etc. complete all as per manufacturer instructions and all as shown on Drawing No. CESZ/2019/TD-42, Sheet No. 1/1
Material & labour for 75 mm thick plain cement concrete 1:3:6 type C2 using 40 mm graded stone aggregate as in sub-floors, sub-bases, fair finished complete all as specified and as directed.
M&L for Non - skid coloured Ceramic tiles 7 to 8 mm thick, area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, laid in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15 mm thick cement screed bed in CM 1:4 complete all as specified and as directed.
S&F anodized aluminium push pull type partly paneled and partly glazed door shutter (double leaf) having top rail of section 85.0mm x 44.45mm x 2.0mm thick, bottom rail of section 85.0mm x 44.45mm x 2.0mm thick, door vertical of section 44.45mm x 44.45mm x 2.0mm thick and lock rail of section 85.0mm x 44.45mm x 2.0mm thick with aluminium anodized chowkhats of section 63.50mm x 33.10mm x 2.50mm thick including necessary jointing cleats, glazing clips, rubber packing, snap beading, screws, stainless steel hinges 3.0 Nos, handle 02 Nos and brass locking arrangement two lever including hydraulically regulated door closer of required Nos etc. including 12 mm thick pre laminated particle board, interior grade pre laminated with decorative face laminations both sides on bottom panel and 5.0mm thick float glass tinted quality on top panel complete all as specified and as directed.
Anodized aluminium sliding glazed three track window shutter (double leaf glazed shutter and single leaf mosquito proof shutter each in single fram work) without sash bars with anodized aluminium shutter of section 40.0mm x 20.0 mm x 1.0 mm thick and window chowkat of section 92.0mm x 29.50 mm x 1.20 mm thick including necessary jointing cleats, glazing clips, rubber packing, snap beading, screws, handle, tower bolts and locking arrangement etc. and 4.0 mm thick sheet glass, tinted quality on panel and stainless steel wire cloth for mosquito proofing, 0.36 mm nominal dia and average width of aperture 1.40mm fixed with aluminium screws and tacks and making good to disturbed surfaces complete all as specified and as directed.
Scarifying or picking gravelled, macadam or bituminous macadam surfaces exceeding 50mm & not exceeding 100 mm deep in area not exceeding 400 sqm complete all as specified and directed.
Rolling and consolidating formation surfaces in cutting with 8 to 12 tonne capacity power road roller complete all as specified and as directed.
Material & labour for 100mm thick Plain Cement Concrete 1:4:8 type D-2 (Nominal Mix) using 40 mm graded stone aggregate as in flooring finished even and fair complete all as specified and directed.
M&L for Forming 12mm thick Expansion joints and 100mm thickness of concrete slab filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ complete all as specified and directed.
M&L for Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound Grade ‘A’ complete all as specified and directed.
Finishing the top surface of concrete roads, pavements, by brooming while the concrete is green complete all as specified and as directed.
Material & labour for thermoplastic reflective road marking paint with glass beads (MORTH Grade) for marking 2.5mm thick centre line, stop line, edge line, dashes, arrows, zebra crossing, brackets & similar work on road surfaces, retro-reflective type of shade / colour as approved by GE, using hot thermoplastic material by automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cleaning the road surface and remove all dirt, seals, oil, grease and foreign material etc. complete all as per manufacturer's instructions and as per direction.
Material & labour for 150mm thick Plain Cement Concrete 1::2:4 type B-2 (Nominal Mix) using 40 mm graded stone aggregate as in flooring finished even and fair complete all as specified and directed.
M&L for Reinforced Cement Concrete M-25 (Design mix) using 20 mm graded stone aggregate as in slabs supported on walls, beams and Columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
Use and waste of formwork to soffits of suspended slabs such as roof slab, floor slabs, landings not exceeding 200 mm thick (horizontal or sloping) for rough finished surfaces of concrete complete all as specified and as directed.
Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressumers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beam, etc. finished rough flat surfaces of concrete complete all as specified and as directed.
M&L for Plain Cement Concrete 1:4:8 type D2(Nominal Mix) using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed.
Material & labour for Reinforced Cement Concrete M-25 (Design mix) using 20 mm graded stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
Material & labour for Reinforced Cement Concrete M-25 (Design mix) using 20 mm graded stone aggregate as in Columns, pillars, piers, posts and struts complete all as specified and as directed.
Material & labour for use and waste of formwork to to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed.
Mild steel TMT bars 6mm to 8mm, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
M&L for mild steel of grade Fe 410-W (Gde-E-250) quality 'A' for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed.
S&F 1.25mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and as directed.
M&L for Black Granite slab 18-20 mm thick machine cut, bedded (15 mm thick in CM 1:6) and jointed with grey cement slurry and pointed with white cement (1:2) with admixture of pigment to match shade of granite including grinding and mirror polishing complete all as specified and as directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed.
Taking out the old unservicable earth continuity conductor or main earting required 25mm x 3mm / 32mm x 6mm aluminium or GI strip complete all as specified and directed.
Taking out the old unservicable lightening conductor of air terminal signal aluminium rod 12mm dia 300mm long complete all as specified and as directed.
Taking out the old unservicable test point terminal block made of gun metal complete all as specified and as directed.
Taking out the old unservicable lightening conductor GI pipe heavy duty complete all as specified and as directed.
Taking out the old unservicable shackle type porcelian insulator suitable for 11KV volts complete all as specified and as directed.
Taking out the old unservicable aluminium conductor steel reinforced wire for protection lightening complete all as specified and as directed.
Taking out the old unservicable sub main wiring 2.50 Sqmm to 6.0 Sqmm PVC insulated copper cunductor cable 1100 Volts grade complete all as specified and as directed.
Taking out the old unservicable surface and wall mounted LED/FL batten with tube complete all as specified and as directed.
Taking out the old unservicable MCB DB SPN/TPN any size of sheet metal alongwith MCB SP/SPN MCCB complete all as specified and as directed.
Taking out the old unservicable PVC insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade 16 Sqmm x 3 core complete all as specified and as directed.
Taking out the old unservicable earthing with galvanized steel plate complete all as specified and as directed.
Taking out the old unservicable MCCB any capacity complete all as specified and as directed.
M&L for Point wiring with 1.5 Sq. mm (nominal area) PVC insulated and unsheathed single core FRLSH copper cable 1100 volts grade with stranded copper conductor in and including PVC rigid concealed conduit (heavy grade) and conduit accessories alongwith continuous earth wire 1.5 Sq mm PVC insulated and unsheathed single core FRLSH cable 1100 volts grade with stranded copper conductor and connected to common earth dolly, with and including 1.6 mm thick cadmium plated sunk MS pressed steel terminal boxes with 3 mm thick plastic laminated sheet cover fixed with brass screws complete for one light/fan point controlled by one, one way switch complete all as specified and as directed. Note:- Cutting and forming chases in masonry, concrete work ete. including cutting and or leaving holes/recesses, sinking etc and making good in cement mortar 1:3 for filling up to 20mm and in PCC 1:2:4 (12.50mm graded stone aggregate) for filling more thann 20mm including matching with existing colour / paint of surfaces shall deemed to be included in the quoted rate.
S&F Switch piano flush buton single pole one way 5/6 Amps ISI marked complete all as specified and as directed.
Sub main wiring with two runs of single core 2.5 sqmm (nominal area) PVC insulated copper conductor FRLSH, multi stranded, unsheathed 1100 volts grade IS-694 marked drawn through and including adequate size PVC conduit (not less than 25 mm bore) accessories and fittings fixed on surface of walls/ceiling and one run of 2.5 Sq mm single core multistranded copper conductor cable as earth continuity conductor. NOTES :- (a) Two runs of cable with one run of earthing wire and one run of conduit shall be measured as one run length. (b) Cable required for connection to DBs shall be deemed to be included in the rate and shall not be measured separately. (c) Earth wire shall run inside the conduit. (d) Extra length of cable required for connection to MCBs shall be deemed to be included in the unit rate.
Supply & fixing of Batten with inbuilt driver made out of high quality aluminium extruded housing and aluminium heat sink for mounting LEDs, and decorative end caps with maximum power consumption 20 watt with min system luminous efficacy lumen/watt≥ 100 @ 6500 CCT and CRI≥ 80, operating voltage of 140-270 volt AC, P.F. >0.90, 3 KV surge protection and current THD≤ 15% complete and including all other standard accessories as per manufacturer in instructions, internally pre-wired including electrically connecting with twisted three core PVC insulated unsheathed flexible cord of 0.75 sqmm copper conductor from ceiling rose complete all as directed.
S&F Ceiling rose surface bakelite, PVC/Poly carbonate, 63.5 mmx 23.5 mm, 3 terminals, isolated body, complete all as specified and as directed.
S&F Switch piano flush buton single pole one way 15 Amps ISI marked complete all as specified and as directed.
Supply & fixing for epoxy powder coated sheet metal enclosure DB SPN 240 Volts 8 Way, IP 43, grouted/flush to wall, double door type with common bus bar for fixing MCB complete all as specified and directed.
S&F MCB SPN 240 volts, 6 to 32 Amps, 10 KA, 'C' series complete all as specified and as directed.
S&F MCB SP 240 volts, 6 to 32 Amps, 10 KA, 'C' series complete all as specified and as directed.
Supply & fixing for epoxy powder coated sheet metal enclosure DB VTPN 415 Volts 4 Way, IP 43, horizontal type grouted/flush to wall, double door type where MCCB upto 160 Amp is to be used as incomer with common bus bar for fixing MCB complete all as specified and directed.
S&F MCCBs of capacity 100 Amps, 415 volts, breaking capacity 16 KA, 4 pole complete all as specified and as directed.
S&F MCB TP 240 volts, 40 to 63 Amps, 10 KA, 'C' series complete all as specified and as directed.
Supply & laying for LT XLPE insulated armoured heavy duty electric cable 1100 volt grade ISI marked with alumimium conductor, cross sectional area 16 Sqmm x 3.5 Core complete all as specified and as directed.
Material & labour for earthing with galvanised steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI or steel wire 4 mm dia as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 15mm dia GI light grade earth lead protection pipe, RCC (1:1.5:3) type A1 precast cover (55cm x 55cm x 5cm) duly reinforced with and including 8mm dia TMT bar @ 150mm c/c both ways, one lifting handle made of 8mm dia TMT bar, embebed in precast cover slab, wire, copper lugs etc mesh, chorcoal and common salt in alternatee layer complete all as specified and directed. Note:- Length of earthwire & protection pipe in above item is considered upto 7.50 meter additional length required shall be measured and paid separately.
Material & labour for earthing with galvanised steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI strip 32x6mm as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternatee layer complete all as specified and directed. Note:- Length of earthwire & protection pipe in above item is considered upto 7.50 meter additional length required shall be measured and paid separately.
Material & labour for earth continuity conductor or main earthing lead fixed to wall or batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 25mm x 3.0mm aluminium strip complete all as directed.
Material & labour for earth continuity conductor or main earthing lead fixed to wall or batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 32mm x 6.0mm GI strip or steel wire complete all as directed.
M&L for lightening conductor for Air termination, single pointed, aluminium rod 12mm dia and 300mm long complete all as specified and as directed.
M&L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw including box made out of 3.0 mm thick MS sheet of size 100mm x 100mm x 50mm with front side hinged type opening and locking arrangement duly painted with aluminium paint, fixed to wall complete all as specified and as directed.
M&L for fixing of lighting conductor GI pipe heavy duty of size 40mm with suitable clamp, GI bolts nuts, check nuts and washers including all accessories required for fixing of the poll on the roof of the shed complete all as specified and as directed. Note:- (i). GI pipe fixed at twenty (20) different locations on the CGI roof in each shed on equal distance. Clear hight above the roof shall be 3.20 Mtr. The GI pipe shall be clamp firmly with CGI roof by means of iron clamp, nuts, bolts and washers (ii). The fixing arrangement shall be as per CESZ TD Drawings No. TD/EM/12 & TD/EM/15.
Shackle type porcelain, vitreous, white, brown or green insulator 150 mm high, 150 mm dia, 11000 volts working pressure, including galvanized mild steel straps of section 38x5mm, washers, insulator bolts 20 mm dia, washers and nuts complete all as specified and as directed.
Material and labour for Aluminium conductor steel reinforced (ASCR) of required sizes as per site requirement drawn and fixed to insulators on poles with permissible sags by proper binding, jumper connection etc all as per standard engineering practice and as per IS all as specified and directed.
Material and labour for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections incl nuts, bolts, washers and incl welding, bending (cold or hot), drilling holes, for bolts any shape or size as indicated or directed and inclusive of one primer coat of red oxide and two coats of aluminium paint complete all as specified and as directed.
Supply, install, testing and commissioning Dehumidifier of Air flow capacity rate 600CuM per Hour with minimum total react heat 8 KW, 415 Volt, 3 Phase, 50Hz including all connecting items necessary for fittings complete all as specified and as directed. Make:- Model No. FFB 600 of BRY AIR (ASIA) Pvt. Ltd./LG PuriCare/ SALES TECH ENGINEERS/ REHOBOTH ENVIRO SYSTEMS/ AKSHAR ELECTRONICS or equivalent makes approved by GE.
Sub main wiring with two runs of single core 6 sqmm (nominal area) PVC insulated copper conductor FRLSH, multi stranded, unsheathed 1100 volts grade IS-694 marked drawn through and including adequate size PVC conduit (not less than 25 mm bore) accessories and fittings fixed on surface of wall / ceilings and one run of 6.0 Sq mm single core multistranded copper conductor cable as earth continuity conductor. NOTES :- (a) Two runs of cable with one run of earthing wire and one run of conduit shall be measured as one run length. (b) Cable required for connection to DBs shall be deemed to be included in the rate and shall not be measured separately. (c) Earth wire shall run inside the conduit. (d) Extra length of cable required for connection to MCBs shall be deemed to be included in the unit rate.
S&F Voltage stabilizer for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 15 KVA complete all as specified and as directed.
Supply & laying for LT XLPE insulated armoured heavy duty electric cable 1100 volt grade ISI marked with alumimium conductor, cross sectional area 35 Sqmm x 3.5 Core complete all as specified and as directed.
S&F MCCBs of capacity 125 Amps, 415 volts, breaking capacity 16 KA, 4 pole complete all as specified and as directed.
Supply & fixing for epoxy powder coated sheet metal enclosure triple pole and earth with a three pin and earth plug with socket complete with one triple pole MCB upto 40 Amp, 415 volts, IP 30, horizontal type grouted/flush to wall, single door type with common bus bar for fixing triple pole MCB complete all as specified and directed.
Supply fixing and testing LED street light fitting 60 watt with LED lamp for building security lighting purpose with pressure die cast aluminium housing with epoxy powder coated with IP66, high power LED as light source and including electronic driver and should have system luminous efficacy lumen/watt≥ 100 @ 5700 CCT and CRI≥ 70, P.F. >0.90, 10 KV surge protection and current THD≤ 10%, internally prewired and including connecting with twin core twisting flexible cord of 0.75 Sqmm copper conductor cable from cable jointing box to light fitting including all other necessary fixing accessories such as GI pipe light grade of 32 mm dia (or higher size as per manufacturer recommendation) & suitable length with MS flat iron clamps (clamps shall be 40 x 5 mm MS flat), nuts, bolts & washers including painting the clamps with two coat of aluminium paint over a coat of red oxide primer for fixing the fitting with wall of the building complete all as specified and as directed.
Steel Tubular Swaged Poles Type 410-SP-31 (9 Metre long) including cast iron base plate, finial taper plug, cap, mild steel bolts, screws, etc. including applying two coats of black bituminous paint internally and externally upto planting depth and applying two coats of aluminium paint over a coat of aluminium primer (externally from top of RCC copping) including writting MES Pole No. with synthetic enamel paint (first grade quality) complete all as specified. Note:- (a) Earthwork will be measured and paid under appropriate items in Schedule 'A' Part-II and PCC will be measured and paid under relevant items in this Schedule. (b) Volume occupied by Steel Pole shall be deducted to derive the quantity of PCC.
Supply laying and testing of cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade cross sectional area 10 Sqmm 2 core complete all as specified and as directed.
Material & labour for Sand cushioning to the full width of trenches for protection of cables including punning down complete all as specified and as directed. Note :- Thickness of sand cushioning shall be the measured after punning down.
Supply and laying for class designation 75 bricks, old size, flat, common clay laid in trenches across the trench as protection of underground cable complete all as specified and as directed.
Supply & fixing to thermoplastic cable junction box for street lights of size size 155x210x92 mm including TPN terminals for cable connection with IP 66 protection including one MCB single pole 6 Amp, 240 volt, 10 kA, 'C' curve mounted on DIN rail and connecting all the incoming and outgoing cable terminals with lugs complete all as specified and as directed. Make :- Hensel CAT No KF 1616G or equivalent model of make list as given in Appendix 'B'.
Material & labour for Plain Cement Concrete 1:3:6 type C-1 (Nominal Mix) using 20 mm graded stone aggregate for foundation, mass concrete and filling complete all as specified and directed.
Material & labour for galvanised steel water tubing 40 mm bore, light grade conforming to IS-1239 with all fittings (such as bends, elbows, tees, short plugs and union etc.) and laid in trenches/cable protection on poles/wall/road crossing/floor crossing complete all as specified and directed.
S&F street light control distribution boards, single phase 230 volt system with 16 Amps, 3 pole contactor and analog time switch for control and operation of the street lights complete all as specified and as directed. Make:- Model No. TL016AB0 of Indo Asian or equivalent model of make list as given in Appendix 'B'.
M.S. Construction
M/S UTTAM SAHA
NANDYENTERPRISES
M/S. SUBHAS CONSTRUCTION CO.
M/S SUNRISE ENTERPRISE
MAA BHAGWATI ASSOCIATES
Allied Construction
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .