Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.5 LAccepted-AOC 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L1 | Accepted-AOC AOC to the lowest bidder | |
| 2 | L2₹48.0 L+₹2,287.20 (0.05%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹48.4 L+₹38,388.60 (0.80%)Rejected-Finance 16 GANGADHAR BABU LANE C R AVENUE KOLKATA 700012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹50.0 L+₹2.0 L (4.07%)Rejected-Finance PINE DALE PINE MOUNT RIDGE SHILLONG 793001 | EAST KHASI HILLS | MEGHALAYA | 793001 | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹51.0 L+₹3.0 L (6.24%)Rejected-Finance 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L5 | Rejected-Finance Not being lowest |
Tender Value
₹61.5 L
EMD Value
₹1.2 L
Closing Date
5 Jan 2022, 6:00 pmClosed
CE AF SHILLONG ZONE
HQ CHIEF ENGINEER AF SHILLONG ZONE MILITARY ENGINEER SERVICES ELEPHANT FALLS CAMP PO NONGLYER SHILLONG 793009
SPECIAL REPAIR TO POWERHOUSE No 1 FOR UPGRADATION OF EXISTING CABLES AND VERTICAL ACBs REDISTRIBUTION OF LOAD OF BUILDING NO P 251 PHASE 1 AT HQ EAC U AF SHILLONG UNDER GE I AF SHILLONG
2021_MES_489612_1
888979/SHL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Shillong
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
GE I AF SHILLONG
₹1.2 L
Yes
1 Feb 2022
22 Nov 2021
7 Jan 2022
22 Nov 2021
5 Jan 2022
22 Dec 2021
Amount
Excavation in trenches not exc 1.5 m wide and not exceeding 1.5 m in depth for foundation etc for shafts, wells, cesspits, manholes, cables etc. not exceeding 10 Sqm on plan and getting out in soft/loose soil, complete, all as specified and directed.
Returning, filling in trenches including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil, complete, all as specified and directed.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 metre above the starting point, complete, all as specified and directed.
Material and Labour for dry river sand filling for under ground cable protection with a layer of 8cm deep before laying and 15cm covering to required width at bottom and top of cable cushioning including cleaning, spreading, levelling, punning complete all as specified and as directed Note : Punned thickness shall only be measured and paid.
S&F sub class B bricks for laying in trenches, complete all as specified and directed.
M&L Brickwork with old size sub class "B' bricks, straight or curved on plan to any radius in built in cement and sand mortar 1:6 , complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B2 (using 40 mm graded aggregates) in foundation/drain/ filling and mass concrete complete all as specified and directed.
M&L for 100mm dia bore GI Pipe Medium grade for cable protection ISI Marked with all fittings and fixed complete to wall or ceiling or laid in trenches / floors.complete all as specified and as directed.
Supply, installation and testing of Adaptor (bus trunking) for 11KV bus section along with 50x6mm coper electrolytic 3 phase air insulated bus bar trunking system of 800 Amps, 50KA breaking capacity , IP 54 protection with 11 KV insualtion sleeve in all 3 phase including nut-bolt with factory fabricated Sheet metal enclosure of size 1.4mtr x 2.00mtr x 1.00mtr cubical type with angle iron 50 x 50 x 6 mm frame and 75mm channel base, made out of 2.00mm thick MS sheet, indoor type to match with the existing with hinged type door and locking arrangement complete including all welding work, painting internally and external surface with one primer coat and two finishing coat of synthetic enamel paint,including taking down the old unserviceable, complete all as specified and directed by Engr-in-Charge.
Material and labour in repairs for factory fabricated Sheet metal enclosure of size 1.4 mtr x 2.00mtr x 0.750mtr cubical type with angle iron 50x50x6mm frame and 75 mm channel base, made out of 2.00mm thick CRCA (MS) sheet, indoor type to match with hinged type door and locking arrangement, for housing of existing 2 Nos of manual drawout type ACB, 800A (Cost of ACB's deemed to be included in quoted rates) and 8 Nos 400 Sqmm 1 core incoming & outgoing cable entry with cable gland, All including fixing of ACBs and incoming & outgoing cable connections, & supply & fix of new 2 Nos digital volt meter, 2 Nos digital ammeter and 2 set indicator LED lamp, complete including all welding work, painting internally and externally surface with one primer coat and two finishing coat of synthetic enamel paint, pad lock, gasket, cable glands, thimbles, nuts, bolts & washers, hinges & inluding supply and fix compact air inuslated bus bar tunking system with aluminium bus bar 800 Amps, 50 KA breaking capacity, IP 54 protection 4 phase for incomming and 4 phase for outgoing for both ACB's separately, including taking down the old unserviceable, complete all as specified and directed.
M&L for Earthing complete with copper earth plate electrode of size 600 x 600 x 3.15mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to copper strip of size 20 x 3mm earth lead by means brazing after fixing of nuts, bolts, check nuts, washers of galvanised iron steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x 10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion, including taking down the old earthing complete all complete as specified and directed.
M&L for XLPE insulated, aromoured heavy duty electric cable with copper conductor, 1100 volts grade, cross-sectional area 400 Sqmm 1 core,laid in trenches or on wall complete with suitable lugs, including taking out the old unserviceable, complete all as specified and directed.
Supply, laying, jointing & testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables heavy duty with aluminium conductor, LT under ground cable1100 V earthed, garde cross sectional area 50 Sqmm 3.5 core, including taking down the old unserviceable, complete, all as specified and directed.
All as per item No. 13 above but for cross sectional area 70 Sqmm 3.5 core.
All as per item No. 13 above but for cross sectional area 95 Sqmm 3.5 core.
All as per item No. 13 above but for cross sectional area 185 Sqmm 3.5 core.
Supply and laying of RCC duct cover of 750mm x600mm x 75mm size,with M-25 aggregate, including taking down the old unserviceable, complete all as specified and directed by Engr-in-Charge.
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 630 Amp complete all as specified and directed.
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 100 Amp complete all as specified and directed.
Supply and fixing of galvanised cable tray of 4 mm thickness, 200mm height mounted on the wall with fixing accessories complete all as specified and directed.
Supply and fixing of MCCB of 400 Amps, 4 pole, 415V AC with breaking capacity 36KA, including taking down the old unserviceable, complete all as specified and directed.
All as per item No. 22 above but MCCB of 250 Amps, 4 pole, 415Volts AC with breaking capacity 36KA.
All as per item No. 22 above but MCCB of 200 Amps, 4 pole, 415Volts AC with breaking capacity 36KA.
All as per item No. 22 above but MCCB of 125 Amps, 4 pole, 415Volts AC with breaking capacity 25KA.
All as per item No. 22 above but MCCB of 100 Amps, 4 pole, 415Volts AC with breaking capacity 25KA.
S&F Vertical TPN DB,s with MCCB of suitable rating upto 160 A and MCB(12 Nos),4 way with 200 amps rated copper bus bar including earth & neutral link, TPN double door, alongwith opening of loop for cable complete with digging and fixing cable with lugs, cable gland and pvc protection pipe as required etc including taking out the old unseviceable one, complete all as specified and directed
Material and labour for sub main wiring with single core PVC insulated 6.0 Sq mm multi stranded copper conductor FRLS cable 1100 volts grade drawn into PVC Conduit and continious earth wire of single core PVC insulated 6.0 Sq mm multi stranded copper conductor FRLS cable 1100 volts grade including taking down old unserviceable sub main wiring of any size and making good disturbed surfaces complete all as specified and as directed. Note:-Two single cable ,one single core green earth wire including one meter pvc conduit is measure as one unit.
Material and labour for sub main wiring with single core PVC insulated 10.0 Sq mm multi stranded copper conductor FRLS cable 1100 volts grade drawn into PVC Conduit and continious earth wire of single core PVC insulated 10.0 Sq mm multi stranded copper conductor FRLS cable 1100 volts grade including taking down old unserviceable sub main wiring of any size and making good disturbed surfaces complete all as specified and as directed. Note:-Two single cable ,one single core green earth wire including one meter pvc conduit is measure as one unit.
M & L in repair Non asbestos fibre cement building boards fixed 6mm thick or laid/ inserted to timber/GI/Aluminium framework with screws, complete all as specified and directed.
Demolition of Brick Work built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any descriptions, complete all as specified and as directed.
Demolition of plain cement concrete in foundation/drain/ filling and mass concrete complete all as specified and directed.
NOTE:- Schedule of credit (Sch-'A' Part-II) amount of Rs. 1,50,500.00 shall be deducted from the total quoted amount by the bidder.
SRI HARSHITA ELECTRICALS
HAMZA CONSTRUCTION CO
M/s A L Traders
M/S DEEDAR ENTERPRISE
M/S HEIYAM KAN SINGH
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .