Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹44.3 LAccepted-AOC C 9 53 IIND FLOOR SECTOR 08 ROHINI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | 1 | Accepted-AOC LOWEST | |
| 2 | 2₹51.0 L+₹6.5 L (14.6%)Rejected-Finance | 2 | Rejected-Finance NOT LOWEST | |
| 3 | 3₹52.9 L+₹8.5 L (19.0%)Rejected-Finance | 3 | Rejected-Finance NOT LOWEST | |
| 4 | 4₹53.4 L+₹8.9 L (20.0%)Rejected-Finance NEAR LIC OFFICE KALAIGNAR ARIVALAYAM SHOP ROOM NO7 GROUND FLOOR OF BACK SIDE PHOENIX BAY SRI VIJAYA PURAM 744101 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744101 | 4 | Rejected-Finance NOT LOWEST |
| Sl No | Description | Qty | Unit | SHYAM ENTERPRISES L2 | DEV TRADERS L3 | L G BUILDERS L1 | RK TRADERS L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Taking down of existing roof treatment as tarfelt, cement plaster, concrete padding, mud phuska etc of any thickness on roof top including flashing on junction of parapet inclusing removing the debris from site to outside MOD land complete all as specified and as directed. | 160 | Sqm | 25 ₹4,000 | 30 ₹4,800 | 10 ₹1,600 Lowest | 50 ₹8,000 |
| 2.00 | M&L for 50mm (average) thickness cement concrete (1:2:4) type B1 (using 20 mm graded stone aggregate) as in roof padding to maintain slop etc complete all as specified and as directed. | 8 | Cum | 2,500 ₹20,000 Lowest | 2,650 ₹21,200 | 2,500 ₹20,000 Lowest | 4,000 ₹32,000 |
| 3.00 | M&L for preparation of plastered/concrete surfaces of roof and applying the under mentioned course of roof treatement complete all as specified and as directed by Engineer-in-Charge.:-
(a) Plastering 10mm thick in cement mortar (1:4) on concrete surfaces using WPC @3% by weight of cement, surface finished even and smooth.
(b) Surface shall be throughly wire brushed, cleaned, washed, dried up properly and applyling evenly a bituminuous primer coat conforming to IS @ 0.4 ltr /Sqm over concrete / plastered roof surface.
(c) Applying evenly a tack coat of bitumen 85/25 grade @1.20 kg/ sqm.
(d) Laying of 3mm thick APP membrane sheet (min weight 3 Kg/Sqm) consisting of a core of 160 gms/Sqm polyster non woven fabric mat protected on both sides with a high quality polymeric asphaltic mix again protected with thermo fusible HMHDPE FILM on dried primed surface by torch application method. APP membrane will normally be laid in length at right angle to the direction of slope. The over lap shall be minimum 100mm on longitudinal direction and 150mm on the transverse direction including cuttings, grooves etc.
(e) Membrane bonded completely to the substrate & the overlaps are then scaled/fused by flame. | 165 | Sqm | 650 ₹1,07,250 | 700 ₹1,15,500 | 350 ₹57,750 Lowest | 550 ₹90,750 |
| 4.00 | M&L for gunniting work to RCC work in column, beam, chajjas, balconies, slabs, landings etc by removing loose concrete, cleaning of surface with wire brush and applying one coat of epoxy paint to rusted reinforcement and including welded wire mesh fabric or wire of wt exc 4 kg per sqm tied to existing reinforcement with nails, adhesive plaster grade for concrete admixture and providing gunniting pressure 2.00/2.50 Kg/Sqm with admixture 1 part of cement and 3 ½ part of sand with a thickness of 50mm average and making the surface even and smooth including all necessary form work and applying 5mm thick cement plaster in cement mortar (1:3) complete all as specified. Note:- Wherever steel bars reinforcement is required the same shall be measured and paid separately. | 200 | Sqm | 750 ₹1,50,000 | 830 ₹1,66,000 | 650 ₹1,30,000 Lowest | 1,000 ₹2,00,000 |
| 5.00 | Taking down chowkhat or frame with shutter (without taking off shutter from the frame) area exceeding 1.5 Sqm but not exc 4.00 Sqm complete all as specified and as directed. Note:- The damaged portion of the tiles/rendering shall be made good with the same material to match with the adjacent surface without any extra cost. | 8 | Each | 100 ₹800 | 150 ₹1,200 | 50 ₹400 Lowest | 50 ₹400 Lowest |
| 6.00 | M&L framed MS work as in doors or gates of angle or other section with guesset plates, rails, braces etc, complete drilling for fitting steel sheeting or other covering door etc to be prepared for hinging or sliding and including either hooks and hinges or steel hanging door fitting also fastering and fixing complete all as specified and as directed. | 800 | Kg | 90 ₹72,000 | 100 ₹80,000 | 75 ₹60,000 Lowest | 90 ₹72,000 |
| 7.00 | M&L for mild steel black sheet in door 1.60 mm thick in steel gate and similar work cut to size, holes punched, including round headed screwed cut nails or revets and fixed to wood or steel framing with plain 40mm lap joints with reveted or welded seams including or turning up, mitred complete all as specified and as directed. | 40 | Sqm | 100 ₹4,000 Lowest | 150 ₹6,000 | 1,000 ₹40,000 | 1,200 ₹48,000 |
| 8.00 | Taking down chowkhat or frame with shutters (without taking off shutter from the frame) area n exc. 1.5 sqm each complete all as specified and as directed. Note:- The damaged portion of the tiles/rendering shall be made good with the same material to match with the adjacent surface without any extra cost. | 18 | Each | 100 ₹1,800 | 160 ₹2,880 | 50 ₹900 Lowest | 50 ₹900 Lowest |
| 9.00 | S&F in replacement of steel window box type made of ERW hollow section of size (130mm x 1.25mm) thick double rebated comprises gauged and glazed skeleton shutter ERW Section 50mmx20mm x 1mm thick double shutter with double leaf and arrangement for cooler opening including iron grill bar with 12mm square complete welded to frame with vertical mulion of size 130mmX65mm with 1.25mm thick ERW box type including cutting holes for hold fast (04 Nos each window) and making good dismantled portion with PCC (1:2:4) type B-1 including follwing fittings welded to frame / shutter :- (a) Hold fast of 150mm long of flat iran 25mmx3mm made to shape - 04 Nos each window. (b) MS Handle cold rolled of size 100mm long - 01 No per leaf. (c) MS tower bolt 100mm long -2 Nos per leaf. (d) Z- Section 20mmx25mm long stopper - 01 No per leaf. (e) MS pintel hinges of size 40mmx 25mm - 02 Nos per leaf including one coat of red oxide shop primer complete all as sepecifed and as directed.
(Note :- The cost of stainless steel mosquito proof Wire mesh and 4mm thick sheet glass shall be deemed to be included in unit rate) | 30 | Sqm | 5,000 ₹1,50,000 | 5,550 ₹1,66,500 | 3,200 ₹96,000 Lowest | 4,000 ₹1,20,000 |
| 10.00 | Demolition of brick work built in cement mortar, including all quoins, arches, pillars etc of any description including removing debrish from site complete all as specified and as directed. | 13 | Cum | 100 ₹1,300 Lowest | 150 ₹1,950 | 150 ₹1,950 | 100 ₹1,300 Lowest |
Tender Value
₹46.8 L
EMD Value
₹93,600
Closing Date
23 Oct 2025, 6:00 pmClosed
GE (AF) PALAM DELHI CANTT 10
GE (AF) PALAM DELHI CANTT 10
ADDN / ALTN TO STORAGE ACCN, CONSTRUCTION OF SEPTIC TANK FOR VISITORS WASHROOM COMPLEX AT AF MUSEUM AND PROVN OF CERTAIN B/R AND E/M WORKS IN BLDG NO. T-94 AT AF STN PALAM UNDER GE (AF) PALAM, DELHI CANTT - 10
2025_MES_725639_2
8025/A/T-48/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) PALAM DELHI CANTT 10
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) PALAM DELHI CANTT 10
₹93,600
Yes
17 Dec 2025
9 Oct 2025
30 Oct 2025
9 Oct 2025
23 Oct 2025
16 Oct 2025
Amount
Taking down of existing roof treatment as tarfelt, cement plaster, concrete padding, mud phuska etc of any thickness on roof top including flashing on junction of parapet inclusing removing the debris from site to outside MOD land complete all as specified and as directed.
M&L for 50mm (average) thickness cement concrete (1:2:4) type B1 (using 20 mm graded stone aggregate) as in roof padding to maintain slop etc complete all as specified and as directed.
M&L for preparation of plastered/concrete surfaces of roof and applying the under mentioned course of roof treatement complete all as specified and as directed by Engineer-in-Charge.:- (a) Plastering 10mm thick in cement mortar (1:4) on concrete surfaces using WPC @3% by weight of cement, surface finished even and smooth. (b) Surface shall be throughly wire brushed, cleaned, washed, dried up properly and applyling evenly a bituminuous primer coat conforming to IS @ 0.4 ltr /Sqm over concrete / plastered roof surface. (c) Applying evenly a tack coat of bitumen 85/25 grade @1.20 kg/ sqm. (d) Laying of 3mm thick APP membrane sheet (min weight 3 Kg/Sqm) consisting of a core of 160 gms/Sqm polyster non woven fabric mat protected on both sides with a high quality polymeric asphaltic mix again protected with thermo fusible HMHDPE FILM on dried primed surface by torch application method. APP membrane will normally be laid in length at right angle to the direction of slope. The over lap shall be minimum 100mm on longitudinal direction and 150mm on the transverse direction including cuttings, grooves etc. (e) Membrane bonded completely to the substrate & the overlaps are then scaled/fused by flame.
M&L for gunniting work to RCC work in column, beam, chajjas, balconies, slabs, landings etc by removing loose concrete, cleaning of surface with wire brush and applying one coat of epoxy paint to rusted reinforcement and including welded wire mesh fabric or wire of wt exc 4 kg per sqm tied to existing reinforcement with nails, adhesive plaster grade for concrete admixture and providing gunniting pressure 2.00/2.50 Kg/Sqm with admixture 1 part of cement and 3 ½ part of sand with a thickness of 50mm average and making the surface even and smooth including all necessary form work and applying 5mm thick cement plaster in cement mortar (1:3) complete all as specified. Note:- Wherever steel bars reinforcement is required the same shall be measured and paid separately.
Taking down chowkhat or frame with shutter (without taking off shutter from the frame) area exceeding 1.5 Sqm but not exc 4.00 Sqm complete all as specified and as directed. Note:- The damaged portion of the tiles/rendering shall be made good with the same material to match with the adjacent surface without any extra cost.
M&L framed MS work as in doors or gates of angle or other section with guesset plates, rails, braces etc, complete drilling for fitting steel sheeting or other covering door etc to be prepared for hinging or sliding and including either hooks and hinges or steel hanging door fitting also fastering and fixing complete all as specified and as directed.
M&L for mild steel black sheet in door 1.60 mm thick in steel gate and similar work cut to size, holes punched, including round headed screwed cut nails or revets and fixed to wood or steel framing with plain 40mm lap joints with reveted or welded seams including or turning up, mitred complete all as specified and as directed.
Taking down chowkhat or frame with shutters (without taking off shutter from the frame) area n exc. 1.5 sqm each complete all as specified and as directed. Note:- The damaged portion of the tiles/rendering shall be made good with the same material to match with the adjacent surface without any extra cost.
S&F in replacement of steel window box type made of ERW hollow section of size (130mm x 1.25mm) thick double rebated comprises gauged and glazed skeleton shutter ERW Section 50mmx20mm x 1mm thick double shutter with double leaf and arrangement for cooler opening including iron grill bar with 12mm square complete welded to frame with vertical mulion of size 130mmX65mm with 1.25mm thick ERW box type including cutting holes for hold fast (04 Nos each window) and making good dismantled portion with PCC (1:2:4) type B-1 including follwing fittings welded to frame / shutter :- (a) Hold fast of 150mm long of flat iran 25mmx3mm made to shape - 04 Nos each window. (b) MS Handle cold rolled of size 100mm long - 01 No per leaf. (c) MS tower bolt 100mm long -2 Nos per leaf. (d) Z- Section 20mmx25mm long stopper - 01 No per leaf. (e) MS pintel hinges of size 40mmx 25mm - 02 Nos per leaf including one coat of red oxide shop primer complete all as sepecifed and as directed. (Note :- The cost of stainless steel mosquito proof Wire mesh and 4mm thick sheet glass shall be deemed to be included in unit rate)
Demolition of brick work built in cement mortar, including all quoins, arches, pillars etc of any description including removing debrish from site complete all as specified and as directed.
M&L for brick work with sub class `B' bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and as directed.
Description all as per srl item No 11.00 here-in-before but except bricks complete all as specified and as directed.
M&L for brick work with sub class `B' bricks, half brick thick wall, straight or curved on plan exc 6m mean radius built in cement mortar (1:4) complete all as specified and as directed.
Taking down cement plaster or cement lime plaster on brick or stone walls etc including raking out joints, hacking for keys, scrubbing down with water etc complete all as specified and as directed.
M&L for 10mm thick plaster on fair faces of brick work or concrete surfaces in cement mortar (1:3) as in ceilings, surface finished even and smooth without using extra cement complete all as specified and as directed.
M&L for 15 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:6), surface finished even and smooth without using extra cement complete all as specified and as directed.
M&L for 15 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:4), surface finished even and fair mixed with liquid water proofing compound @200ml per bag of cement or as per manufacturer's instructions complete all as specified and as directed. Note:- Liquid WPC shall be measured and paid seperately.
Supply only Integral Water Proofing compound complete all as specified and as directed.
M&L for prepration of new surface of plaster and applying three coats of white wash on wall complete all as per specified and as directed.
M&L for preparing plastered or unplastered new surfaces on ceilings including brooming down or steel wire brushing, scraping down and applying three coats of white wash complete all as specified.
M&L for preparation of plastered or unplastered new surfaces on walls including brooming down or steel wire brushing, scraping down and applying two coats of cement base paint of approved colour and shade complete all as specified and as directed.
M& L for preparation of new plaster surface of walls ,chajjas, soffits & beam including necessary scaffolding and applying applying complete with wall putty 3 mm average thick with two coats of acrylic smooth exterior paint of required shade 1.43ltr/10sqm over a coat of exterior primer 2.20kg/sqm complete all as per manufacturers instructions complete all as specified and as directed.
Demolition of concrete in ground floor and pavings n.exc 15 cm thickness below or above ground level.incl removing the debris from site to out MoD land complete all as specified and as directed.
M&L for hard core of gauge not exc. 63mm, deposited, spread and levelled in layers not exc. 15 cm thick watered and rammed to a true surface of broken stone or boulders etc. complete all as specified and as directed.
M&L for 100mm thick PCC (1:2:4), type B1, (using 20mm graded stone aggregate) as in floor, surface finished even and smooth using extra cement with and including use of waste of form work complete all as specified and as directed.
M&L for 50 mm thick cement concrete (1:3:6) type C1, (using 20 mm graded stone aggregate) as in plinth protections, surface finished even and smooth without using extra cement complete including use and waste of necessary form work complete all as specified and as directed.
M&L for glossy finished coloured 60 mm thick machine pressed precast concrete interlocking paver block of M-30 laid over 50mm thick sand cusioning with and including over 75mm thick cement concrete type C-2, (1:3:6) (40 mm graded stone aggregate) as in sub base complete all as specified and as directed.
S&F mild steel angles/rectangular hollow section/steel tubular roof trusses (framed), and fastening including distance pieces etc for tubular trusses, purlin, rafter, post and similar work including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 complete all as specified and directed.
S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment complete all as specified and as directed.
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or scrwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n exc 10 cm long complete all as specified and as directed.
S&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders framed balusters, walk ways, railings, frame work of water tanks and similar work conforming to Fe-410-0 or Fe 310-0 complete all as specified and directed by Engineer-in-charge.
S&F hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts complete all as specified and as directed.
M&L for preparation of new painted surfaces of steel and steel based material of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
M&L for preparation of old painted surfaces of steel and steel based material of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting roof covering sheet PGI or Asbestos (Corrugated, semi corrugated etc.) of any thickness including ridges, hips valleys as in roof covering complete all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding/chajja projections, fixed with self tapping screws complete all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding/chajja projections, fixed with self tapping screws complete all as specified and as directed.
M&L for RCC Nominal mix (1:2:4) type B1 (using 20mm graded stone aggregates) as in footing, foundation, beam, column, lintels, cantilevers etc complete all as specified and as directed.
M&L for RCC Nominal mix (1:2:4) type B1 (using 20mm graded stone aggregate) as in slabs supported on walls, chajja, roof beam, roofs canopies, facia, shelves etc complete all as specified and as directed.
M&L for 40mm thick Damp proofing course in cement concrete (1:2:4) type B-0 (using12.5mm graded stone aggregate) mixed with water proofing compound complete all as specified and as directed. Note:- WPC shall be measured and paid separately.
Use and waste to formwork to soffits of footing, foundation, beams, columns, lintels, cantilivers etc complete all as specified and as directed.
Use and waste of formwork to soffits of suspended slab such as roof slab, facia, chajja etc complete all as specified and as directed.
M&L for cement concrete (1:2:4) type B-1, (using 20 mm graded stone aggregate) as in copings, window cills, kerb stone for foot path and similar items with plain fair finishing including chamfers, weathering, throating etc and set in CM (1:4) complete joints to match complete all as specified and as directed.
M&L for milld steel TMT bars 10mm dia and over cut to lrngth, bent to shape required, including cracking, bending etc and bending with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed .
M&L for mild steel TMT bars 5 to 10mm dia as in sturrips cut to lrngth, bent to shape required including cranking, bending etc and binding with mild steel wire (annealed) not less than 0.90 mm dia or scruring with clips complete all as specified and as directed.
Excavation in trenches for n exc 1.50 mtr width but n exc 1.50mtr depth for foundation not exc 10 sqm on plan and n exc 1.50mtr in depth including getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n exc 25 cm thick complete all as specified and as directed.
Removal of excavated material to a distance n exc 50 m and depositing where directed at a level n exc 1.50m above the starting point complete all as specified and as directed.
M&L for cement concrete (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundations, filling and mass / Sub Base Concrete complete all as specified and as directed.
S&F unplasticisted PVC dranage pipe 200mm dia type 'B' with wall thickness 4mm (min) of pressure rating 4KN/Sqm, laid in trenches and jointed with cement solvent including testing complete all as specified and as directed.
M&L100 mm thick concrete bed to drain pipes in cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) including packing under and haunching against the sides of pipes after they are laid and tested for 200 mm bore pipe complete all as specified and as directed.
M&L for reinforced concrete pipes, class NP2, 200 mm bore, laid and jointed complete with collars complete all as specified and as directed.
M&L for 20mm thick prepolished granite tiles of area of each slab exc 0.36 sqm, laid on platform etc in wall, column and floor surface and jointed with grey cement slurry and pointed in white cement with pigment to match the shade of granite stone including moulding/rounding and polishing complete all as specified and as directed.
M&L for preparing plastered or unplastered new surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed.
&L for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat (40 x 3)mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed.
S&F for 6mm thick non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specied and as directed.
M&L for anodised / aluminium coloured power coated (minimum thickness of powder coating 50 micron) door frame and shutter, single or double leaf glazed with pre-laminated particle board interior grade including aluminium powder coated beading, rubber gasket and packing materials drilling in existing wall and thrust bolt of suitable size complete comprising the following:- (a) Door frame section 101.60mm x 44.45mm x 1.93 mm fixed as per specified. (b) Door Shutter Vertical Style of Size 85mmx44.45mmx2 mm as per specified. (c) Door Shutter top style section 95.25mmx44.45mmx2.00 mm as per spd. (d) Middle lock rail/bottom rail section 150mmx44.45mmx1.93mm. (e) Aluminium coloured powder coated tower bolt 02 Nos in each shutter of 200 mm long. (f) Aluminium coloured powder coated handle 02 Nos in each shutter 150 mm long. (g) Door Floor spring ISI Marked in each shutter. (h) Six lever mortice lock brass in each door. (j) 12 mm thick pre laminated particle board (pre laminated both face) exterior grade ISI Marked (k) 5mm thick tinted glass/Plain glass(Colour).
M&L for anodised /aluminium power coated (minimum thickness of powder coating 50 micron) window frame (coloured as approved by GE) of three track using Jindal section No 20832 (92mmx31.75mmx1.50mm or its equivalent) fixed with thrust bolt in walls by drilling and sliding shutter of section No 20844 (40mmx18mmx1.29mm) or its equivalent section for glass including 4.00mm thick tinted glass fixed with rubber beading and bushes complete in two track and 0.36 mm dia and 1.40mm aperture stainless steel wire mesh fixed with screw and aluminium beading complete all as specified and as directed.
S&F rubber beading to be fixed over glass panes in aluminium door and window complete all as specified and as directed.
S&F in repair aluminium anodised glazing clip to be aluminium door / window frame rubber beading to be fixed over glass panes in aluminium door and window complete all as specified and as directed.
M&L for brick work with sub class `B' bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:4) complete all as specified and as directed.
M&L for 15 mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar (1:4), surface finished even and smooth without using extra cement complete all as specified and as directed.
M&L for RCC NP3 150mm dia pipes laid on PCC bed (1:3:6 type C2,150mm thick) including packing under and haunching against sides with excavation in any type of soil at average depth of 1.50m, including manholes/drop manhole of standard size made of Brick masonry/RCC with SFRC cover and frame including 150 mm thick PCC cradle,complete all as specifide and directed.
M&L for construction of Septic tank (150 users) excavation in any type of soil, foundation in PCC(1:2:4), brick work in CM(1:4) including RCC slab cover, as per TD complete Drawing No CEPZ/C-TD/013/13 Sheet No-1/5 to 5/5
M&L for Sokage well, excavation in any type of soil, foundation in PCC(1:3:6), walls of brick work in CM(1:4), RCC slab cover including filling with brick bats complete of size 3.40m internal dia x 4.00 m deep, As per TD Drawing No CEPZ/C-TD/013/13 Sheet No - 1/5 to 5/5.
M&L for cutting into existing manholes for connecting new drains of dia 150 mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-1 smooth finished, and reforming benching as required complete all as specified and as directed.
M&L for mild steel work as band straps, supports, stey hold fast, gratings and wall ties and similar small article conforming to IS-FE 290 Gde 165 complete all as specified and directed. Note:- Embedded portion of hold fast /wall ties shall be treated with coal tar black paint.
Taking down carefully unserviceable copper/aluminium point wiring (light, fan, socket or power)complete including fixture and fitting such as switches, ceiling rose lamp holder, regulators, sockets, light fittings, wooden terminal boxes, plastic laminated sheet cover, including taking down of DB’s, meter board any type complete all as specified and as directed.
Taking out unserviceable sub main wiring with conduits / battens etc complete all as specified and as directed.
Material and labour for point wiring with single core PVC sheathed 1100 volt grade cable with multi stranded copper conductor of size 1.5 Sq mm FRLSH (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, with GI saddles GI screws, rawl plugs (concealed conduit/surface wiring in walls and casing capping on ceiling or roof ) including Tee, Junction boxes and provision of 3 mm thick plastic laminated sheet cover of suitable size on existing terminal boxes with new brass screws for mounting switches sockets and regulators and drawing continuous earth wire with and including PVC sheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified for one light/Fan point controlled by one Switch complete all as specified and as directed. Note :- (i) Cost for cutting, chasing and making good to existing surfaces shall deemed to be included in the quoted rate.
Description all as per srl item No. 70.00 here-in-before but for one 3 pin 5 Amps socket out let point on the same board controlled by one switch complete all as specified and as directed.
Description all as per srl item No 70.00 here-in-before but for one power point 6 pin 15 Amps socket out let with 2.5 Sq mm stranded copper conductor cable PVC insulated FRLSH including earth wire 2.5 Sq mm copper FRLSH conductor cable connected to earth dolly complete all as specified and as directed.
S&F modular switch 1 way 6 Amps one module complete all as specified and as directed.
Supply and fixing of modular socket 6 Amps 2/3 Pin combined 02 module complete all as specified and directed.
S&F modular switch one way 16 Amps, one module complete all as specified and as directed.
S&F socket modular type 6 amp/16 amps, 2/3 pin combined 02 Module complete all as specified and as directed.
Supply and fixing for ceiling rose, surface type, 65mm x 50mm, 2 to 3 terminal complete all as specified and as directed.
Supply and fixing ceiling fan complete with blades, down rod, elecronic regulator and accessories 230 volt 1200mm sweep 6 BEE 5 star rated with brushless direct current motor (BLDC) including GI pipe 40mm medium grade for hanging fan as per site requirement complete all as specified and directed by Engineer- in-charge.
S&F Indoor decorative LED Battens integrated type 20 watt 4 feet white 6500K fixture complete with all accessories internally pre wired and including connecting up with twin core copper conductor cable complete all as specified and directed.
Supply and fixing for sheet metal enclosure for distribution board SPN (when MCBs to be used ) 12 way, double door 200 Amps rated bus bars and with neutral, earthing bar and din rail complete all as specified and as directed.
Supply and fixing MCB, TPN 40-63A,10kA complete all as specified and as directed.
Supply and fixing MCB, SP, 6-32A ,10kA complete all as specified and as directed.
Material and labour for submain wiring with two single core 4.0 sq mm PVC insulated FRLSH multistrand copper conductor cable drawing into and including rigid non metallic PVC conduit, medium grade ISI marked with all conduit fittings & fixing accessories and one single core 4.0 Sqmm FRLSH multistranded copper conductor cable as continuous earth wire complete all as specified and directed by Engr-In-Charge. Note:- Two core main wire, one core of earthing wire, PVC conduit and cutting chases shall be measured and paid as one run.
Supply and fixing DBOXx MCB protected socket, PVC plastic base model with MCB and top PVC enclosure of capacity 20 Amp, SPN MCB complete all as specified and as directed.
Supply and laying in replacement of XLPE LT 1100 Volt Grade, armoured under ground cable of size 16 Sqmm 4 core with stranded aluminium conductor in trenches /passing through pipes/ on poles etc complele all as specified and as directed. Note:- Excavation, earthwork and cable protection shall be deemed to be included in unit rate.
SHYAM ENTERPRISES (BID ID -3461387)
DEV TRADERS (BID ID -3461646)
RK TRADERS (BID ID -3463204)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
BOQ_822287.xls
BOQ • 0.75 MB
TENDER.pdf
Tender Documents • 1.14 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .