Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹51.6 LAccepted-AOC | ₹51.6 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹53.8 L+₹2.1 L (4.16%)Rejected-Finance C 295 ADG P CHENNAI | CHENNAI | TAMIL NADU | 600001 | ₹53.8 L+₹2.1 L (4.16%) | L2 | Rejected-Finance Being not L1 |
| 3 | L3₹54.4 L+₹2.8 L (5.37%)Rejected-Finance | ₹54.4 L+₹2.8 L (5.37%) | L3 | Rejected-Finance Being not L1 |
| 4 | L4₹54.5 L+₹2.9 L (5.53%)Rejected-Finance | ₹54.5 L+₹2.9 L (5.53%) | L4 | Rejected-Finance Being not L1 |
| 5 | L5₹55.5 L+₹3.9 L (7.53%)Rejected-Finance SHOP NO 48 HOSANNA LAXMI VENKETESWARA LAYOUT 2ND CROSS MARAGONDANAHALLI K R PURAM POST BANGALORE 560036 | BENGALURU URBAN | KARNATAKA | 560036 | ₹55.5 L+₹3.9 L (7.53%) | L5 | Rejected-Finance Being not L1 |
Tender Value
₹66.7 L
EMD Value
₹1.3 L
Closing Date
9 Nov 2023, 6:00 pmClosed
Neeraj Mehrotra, IDSE, CWE
Commander Works Engineers AF South Gangamma Circle Opp Guard Room 410 AFS Jalahalli Bangalore 560013
SPECIAL REPAIRS TO BUILDING NO P-889 AT AFS JALAHALLI BANGALORE GE (M) AF STATION JALAHALLI BANGALORE
2023_MES_623337_1
85264/E8
Open Tender
Civil Works
Item Rate
180 days
GE (M) (AF) Jalahalli
As per tender documents
7 documents required · 7 mandatory
₹1,000
GE (M) (AF) Jalahalli
₹1.3 L
22 Dec 2023
16 Oct 2023
16 Nov 2023
16 Oct 2023
9 Nov 2023
4 Nov 2023
16 Oct 2023 - 24 Oct 2023
Amount
Excavation in trenches hard and dence soil not exe. 1.5m wide and not exe. 1.5m in depth for laying cable and getting out in hard/ dense soil.
Excavating in post holes (or similar holes) in soft/ loose soil each n exc 0.5 Cum, getting out, returning, filling in , removing surplus soil to distance not exceeding 50.00 mtr and raming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, complete all as specified and direceted.
Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soil all as specified .
Removing the excavated soil to a distanceand refixing properly as per existing surface c not exe 50m and depositing where directed at a level n exe 1.5m above the starting point all as directed.
M&L PCC 1:4:8 (Type D2) using 40 mm graded stone aggregate as in foundation filling and mass concrete, complete, all as specified and directed.
M&L for providing 25mm thick cement concrete (1:1.5:3) type A0 using 12.5mm graded stone aggregate, mixed with admixed (fosroc nitoband or equivalent make) at 2% by weight of cement, and cleaning the prepared concrete surfaces an applying Fosroc Nitoproof (Min 0.80mm dft) over a priming coat of Nitoproof primer or equivalent products complete, all as specified and directed.
M&L PCC 1:3:6 type C-1 using (20mm graded stone aggregate) as in hold fast complete, all as specified and directed.
S & F factory made, 2nd class hardwood 35mm thick Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete, all as specified and directed.
S & F factory made, 2nd class hardwood 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats and all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube complete all as specified.
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. M.S frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the M.S frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supplying & fixing in the frame at site, complete all as specified.
S&F Extruded aluminium alloy handles, fabricated type, anodised 150mm complete, all as specified and directed.
S&F Floor door stoper of alumunium alloy body and tongue, aodised with hard drawn steel spring, fixed in floor, 150mm size complete, all as specified and directed.
S&F 150 mm size aluminium, anodised, barrel tower bolts of extruded section and fixed complete, all as specified and directed.
S & F 300 mm size aluminium alloy fancy type, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast-aluminium alloy and fixed
S & F Butt hinges, medium weight, cold rolled mild steel, and fixed 100 mm long Stainless steel Butt hinges extruded, complete, all as specified and directed.
S&F in repair mild steel 300 mm, ordinary rat tail rod pattern springs including roller and roller plate, complete, all as specified and directed. complete
M & L for mild steel powder coated pelmet rods 25mm outer dia including 2 Nos of brackets 2 Nos of pintals or side brackets as per site requirement including 10 Nos of curtan rings in each curtain rod complete all as specified and directed.
S&F in repair stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed.
Resecuring or easing and adjusting wooden shutters of any description exceeding 1Sqm and not exceeding 2Sqm each with taking out and re-fixing in same opening complete all as specified and directed.
M&L for servicing/ easing of steel windows of size not exceeding 2 sqm each scrapping, hacking, oiling, necessary welding, replacing broken hinges, handles, peg stay etc and making good disturbed portion painting all as specified.
M& L for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 all as specified
M&L Rolled sections/ tubes as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe 410W (GdeE-250) quality B, complete, all as specified and directed.
M & L Structural steel of plates, Fe-410 W (Gde E-250) Quality-B), channels, square cut or notched (ordinary or counter sunk) forming holes with riveted, bolted or welded attachments all as specified and directed
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S&F Steel Window/ ventilators with top hung shutter including hinges, steel peg stay etc complete all as specified and directed.
M&L for rendering 10mm thick in CM 1:3 on fair faces of brick work or concrete surfaces as in backing coat to receive wall tiles/skirting/dado etc. Complete, all as specified and directed.
M&L for Rendering 15mm thick in CM (1:4) (5mm with WPC over 10mm thick) in two layers on external surfaces of walls mixed with water proofing compound on stone masonry/concrete surface or brickwalls finished even & smooth without using extra cement.
M&L for rendering 5mm thick in CM 1:3 on fair faces of brick work or concrete surfaces of ceiling finished even and smooth without using extra cement and all as specified and directed.
M&L for rendering 15 mm thick in CM 1:6 on fair faces of brick work/stone masonary finished even and smooth without using extra cement.
M & L for 75 mm thick cement concrete 1:3:6 type C-2, using 40mm graded stone aggregates complete finished fair and eve complete, all as specified and directed..
M&L Providing cement concrete 1:2:4 type B1 using 20mm graded stone aggregate in roof, chajjas, coping, bed blocks and similar work including necessary form work complete, all as specified and directed.
M&L for 20mm thick screed bed in CM 1:6 for laying floor finishes, complete, all as specified and directed.
M&L for 15 mm thick screed bed in cement mortar 1:6 for laying floor finishes complete, all as specified and directed.
M&L for Bitumastic gola, with 80/25 bitumen and coarse sand mixture. 1:3 by weight, 8cmx8cm at the junction of roofing to vertical surfaces all as specified
M&L for non skid coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile complete, all as specified and directed..
M&L for Ceramic coloured tiles 10mm thick (Square/ rectangular) polished, dark shade, area of each tiles exceeding 0.18sqm but not exeedingc 0.38 sqm, in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, all as specified and directed
M&L for ceramic coloured tiles of size 300x450mmx7- 8mm thick, on verticals surfaces, set and jointed inneat cement slurry and pointed in coloured cement to match the shade of tiles complete, all as specified and directed.
S&F chequered cement concrete tiles 30cmx30cmx25mm thick set jointed and pointed with grey cement and pigment to match the floor all as specified and directed.
M&L for taking down of existing sunken slab treatment from the sunken portion and removing of existing filling of sunken, cleaning the surfaces washing down with water and rubbish off the primises, cleaning and filling cracks with sealing compound, brushing neat cement [email protected]/sqm and providing following applications :- (a) 25mm thick cement concrete type B-0 (1:2:4 using 12.5mm graded stone aggregate) on sunken slab portion. (b) M&L for two coat of acrylic cementitious water proofing coating (Dr FIXIT pidfin 2K manufactured by M/S Pidilite industries Ltd or equivalent). (c) Rendering 15mm thick CM(1:3) alongwith liquid water proofing compound. (d) Filling of brick bats and finishing the top surfaces even and smooth without using extra cement (e) Acrylic cementitious water proofing coating as per manufacturs instruction. Note - (i) Leakage/seapage testing shall be carried out before filling the brick bats by filling the water in sunken portion & checking the same after 72 hrs (ii) If any leakage/seapage is observed contractor will rectify the same without any extra cost and water ponding test mentioned above shall be redone.
S&F Rotational moulded polyethylene water storage tanks of storage 1000 litre (cylindrical vertical with closed top) hoisted and fixed in position incl tank nipple/adaptor wherever required all as specified
S & F in repairs PVC low level flushing cistern 10 Ltr capacity including necessary brackets including connecting flush pipe etc and making good the disturbed surfaces all as specified and directed.
S & F in repairs viterous china wash basin white flat back size 550 x 400 mm including brackets, waste coupling etc all as specified and directed.
S & F 15 mm dia stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for CPVC/PVC/iron pipe, complelte all as specified and directed.
S&F steel tubes medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor bore of pipe 15mm dia. including making hole in RCC slabs for vertical pipes & making good the same with Cement Concrete I:2:4, complete all as specified and directed.
S&F steel tubes medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor bore of pipe 20mm dia. including making hole in RCC slabs for vertical pipes & making good the same with Cement Concrete I:2:4, complete all as specified and directed.
S & F wall mixture including three joints to GI pipes of 15/20 mm bore and plugging & screwing to walls and making good the disturbed surfaces of walls to match with existing surfaces all as specified and directed.
M&L for White Toilet paper holder of vitreous china fixed to walls with chromium plated (CP) brass screws all as specified and directed.
S&F brass Choromium plated shower rose with or without swivel joints 125mm size including fixing complete all as specified.
Supply & fixing Gun metal gate valves with iron wheel head, screwd both ends for iron pipe 25 mm dia with all fitting complete all as specified and directed.
S&F 15 mm bore Bib taps cast copper alloy chromium plated with crutch or butterfly handle screwed down screwed for cpvc pipe or for brass ferrule and fixed complete, all as specified and directed.
S&F 15 mm bore pillar tap with capstan heads chronium palted screwed down high pressure with or without letter 'Hot' or 'Cold' with long screwed shanks and fly nuts screwed for CPVCPVC/Iron pipe and fixed complete, all as specified and directed.
S & F in repairs viterous china wash down water closet (Pedestral pattern) EWC white incl plastic water closet seat cover and mild steels chromium plated on aluminium hinging device and connecting to 'P' or 'S' incl connecting flush pipe with flushing rim all as specified
M&L for Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete, all as specified and directed.
S & F 75mm PVC (SWR) floor trap, plain with cp grating including jointing with solvent cement complete, all as specified and directed.
Dismantaling of cast iron / RCC/ PVC drain pipes 75/110mm jointed in cement mortar and taking out from trenches or walls of any bore including fittings complete, all as specified and directed.
S & F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to floor/walls bore of pipe 75 mm with PVC clamps and saddles complete, all as specified and directed.
S & F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to floor/walls bore of pipe 110 mm with PVC clamps and saddles, complete all as specified and directed.
S & F PVC (SWR) bends of any radius with access door bore of pipe 75 mm complete, all as specified and directed.
S & F PVC (SWR) bends of any radius with access door bore of pipe 110 mm complete, all as specified and directed.
S & F PVC (SWR) junction single(single T) equal or unequal with access door bore of pipe 75 mm bore complete, all as specified and directed.
S & F PVC (SWR) junction single(single T) equal or unequal with access door bore of pipe 110 mm bore
S & F PVC (SWR) reducers 110 mm bore complete, all as specified and directed.
S & F PVC (SWR) vent cowl bore of 110 mm bore complete, all as specified and directed.
S & F PVC (SWR) bends any radius of bore 75 mm bore complete, all as specified and directed.
S & F PVC (SWR) bends any radius of bore 110 mm bore complete, all as specified and directed.
Supply and fix vitreous China urinals, Half stall type white (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and as directed.
S&F Urinal spreader of PTMT any colour for fixing with 15mm dia pipe (minimum wt 60 gms) all as specified and directed
S & F in repair tubular towel rail brass chromium plated 20 mm dia 'D' type 60 cm long between flanges complete, all as specified and directed.
S & F waste coupling 32 mm dia of PTMT (half or full threaded) minium weight 45 gram complete, all as specified and directed.
S & F in repair PVC connections 15mm size with PTMT nuts of length 450mm complete, all as specified and directed.
M & L for PVC waste pipe 32 mm dia flexible with cup to fit wash hand basin waste coupling complete all as specified and directed.
S&F stainless steel wire cloth of 0.36mm dia of wire and average width of aperture 1.40mm with staples or serviceable fillets complete, all as specified and directed.
S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete, all as specified and directed.
M & L for preparation of old surfaces of wall including complete removal of existing treatment including washing down and cleaning etc. and applying 3mm thick wall putty on walls and applying two coats of distemper oil emulsion over a coat of priming with using mechanical tools & plant complete all as specified and directed
M & L for preparation of new plastered surfaces of wall and applying three coats of white wash on walls including preparation of surfaces
M & L for preparation of old surfaces of wall including scrapping down, smoke soot, efflorescence salts trading oil and greasy spots etc by applying one coat of white wash on walls
M & L for preparation of new plastered surfaces of wall and applying three coats of white wash on ceiling including preparation of surfaces, complete, all as specified and directed.
M & L for preparation of old surfaces of wall including scrapping down, smoke soot, efflorescence salts trading oil and greasy spots etc by applying one coat of white wash on ceiling complete, all as specified and directed.
Material & Labour for preparation of old decorated surfaces of walls including cornices, pilasters etc (Plastered or un plastered surfaces) and applying One Coats of cement base paint complete all as specified and as directed.
M&L for preparation of old decorated surface of walls and applying one coat of weather coat (ACE) exterior emulsion paint all as specified and directed
M&L for preparation of new wood and wood based surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint over a coat of pink wood primer all asspecified and directed
M& L Preparation of old treated wooden surface exceeding 10 cm width and grith and applying one coat of synthetic enamel paint all as specified
M&L for prepration of new steel surface and iron work of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide and all as specified and directed .
M&L for prepration of old steel surface and iron work of any description over 10cm width or girth not otherwise described and applying one coats of synthetic enamel paint and all as specified and directed .
Hacking out old broken glass of any thicknes / size or description from metal frames fixed with glass putty complete, all as specified and directed.
M&L for 3mm thick sheet glass, ordinary quality and glazing with oil putty with spring clips in metal frames in square n.exc 0.5 sqm each panes complete, all as specified and directed.
S &F 4mm thick frosted glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane and all as specified and directed.
M&L for preparation of new or previously untreated steel surfaces and applying two coats of synthetic enamel paint over a coat of primer red oxide, zinc chrome complete all as specified and directed.
M & L for point wiring for one Light point using approved colour code as per IS (Red, Black and Green for single phase circuits) with multistrand copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade ISI-694 marked with valid CM/L No. drawn in Conduit pipe 20mm PVC rigid non metalic conduit/casing-caping, including mild steel Modular sunken box including inner/outer sheet/cover plate and fixed covered etc including all as per site require PVC insulated multi-stranded copper conductor 1.5 sqmm nominal cross sectional area single core FRLS cable as earth continiuty conductor to common earth and connecting to earth dolly complete for one light point controlled by one 5/6 amps one way switch.
All as per item No-92 but here in before One Light point/Bldg security light point controlled by two 2-way switches , with cables 1.5 sq. mm size. Make : Havells/Anchor/ Finolex
All as per item No 92 but here -in- before One Celing fan point with Cable 1.5 Sqmm Size complete all as specified and directed. Make : Havells/Anchor/ Finolex
All as per item No 92 but here -in- before one Exhaust fan point with Cable 1.5 Sqmm Size complete all as specified and directed. Make : Havells/Anchor/ Finolex
All as per item No 92 but here -in- before One 5 pin socket outlet 5/6 Amps 2-in-1, on independent board. Make : Havells/Anchor/ Finolex
All as per item No 92 but here -in- before One point 5 pin socket outlet 5/6 Amps 2-in-1, on the same board with other switch.Make : Havells/Anchor/ Finolex
All as per item No 92 above but one point 5/6 pin socket outlet 15/16 Amps 2-in-1, independent board with cable 2.5 sq mm size Make : Havells/Anchor/Finolex
S & F Modular Switch 1 way 6 A, 1 Module all as specified and directed.
S & F Modular Switch 2 way 6 A, 1 Module all as specified and directed.
S & F Modular Switch 1 way 16 A, 1 Module all as specified and directed.
S & F Modular socket 6 A, - 2/3 pin combined 2 module all as specified and directed.
S & F Modular socket 6/16 A, - 2 / 3 pin comb 2 module all as specified and directed.
S&F Modular fan regulator 120W, 2 Module for C/F complete all as specified and directed.
S&F ceiling rose surface bakelite 3 terminals 65x50mm complete all as specified and directed. Make : Anchor/ Crabtree/Legrand
S&F LED light fitting,4 feet ,1x20 watt 230 Volt, AC Supply decorative box type, square profile with driver, holder including LED tube light connecting up with all reqire accssories and three core flexible copper conductor cable of suitable size from ceiling rose complete.with all accessories complete all as specified and directed .
S&F LED light fitting, 2 feet ,1x10 watt 230 Volt, Supply and fixing LED light fitting mirror type withhigh out put diffuser 220 V AC decorative type with driver holder and LED lamp including connecting up with all reqire accssories and three core flexible copper conductor cable of suitable size complete.
Supply and Fixing Surface/Recess mounted 36 Watt Supply and fixing LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC square shape with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with all reqire accssories driver and three core flexible copper conductor cases of suitable size and electric connection complete all as specified and directed
Supply and fixing LED Building security light 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including with Suitable dia GI bracket with clamp-02 Nos, nut-bolt Washer etc complete all as specified and directed by Engr-in Charge.
M&L for sub main wiring with two single core stranded copper conductor unsheathed PVC insulated FRLS cable 1100V grade, 4 sq mm drawn through and including suitable size of non-metallic PVC rigid conduit with 4sqmm copper conductor cable as earth conductor and conduit accessories fixed up in surface/ recessed as required, including connecting up complete all as specified and directed including taking down old U/S wiring. Note:-Two run of cable and one run of earth continuity copper conductor and non metalic PVC conduit shall be measured as one unit length.
M&L for sub main wiring with two single core multistranded copper conductor unsheathed PVC insulated FRLS cable 1100V grade, 6 sq mm drawn through and including suitable size of non-metallic PVC rigid conduit with 6 sqmm copper conductor cable as earth conductor and conduit accessories fixed up in surface/ recessed as required, including connecting up complete all as specified and directed including taking down old U/S wiring. Note:- Two run of cable and one run of earth continuity copper conductor and non metalic PVC conduit shall be measured as one unit length.
M&L for sub main wiring with four single core multistranded copper conductor unsheathed PVC insulated FRLS cable 1100V grade, 4x10.0 sq mm drawn through and including suitable size of non-metallic PVC rigid conduit with 2x6.0 sqmm copper conductor cable as earth cable conductor and conduit accessories fixed up in surface/ recessed as required, including connecting up complete all as specified and directed including taking down old U/S wiring. Note:- Four run of cable and two run of earth continuity copper cable conductor with non metalic PVC rigid conduit shall be measured as one unit length.
Rewinding of unserviceable ceiling fan/wall mounted fan with any type any size upto 1400mm sweep with copper wire , bush, insulation etc and it's make serviceable and refix at existing place/site complete all as specified and as directed. Note: U/S copper scrape received from fan = Appx 100gm/Each taking down in schedule of credit.
Taking down userviceable Exhaust fan, Metal Body 300/450 mm Size remove sealing cable end, blades from site sent to market for make it serviceable with changing bearing/bush, capacitor, clamp, rubber bush rewinding, repainting, servicing, re-write the MES No on fan & fix blades and Refixing to Existing place and connection complete all accessories as per site required and as directed by Engr-in-Charge.(Note :Quoted rates of items for taking down, servicing, repainting, hanging and electrical connection complete of Exhaust fan all are inclusive in Each Job)
Rewinding of unserviceable Exhaust fan with any type any size upto 300mm with copper wire , bush, insulation etc and it's make serviceable and refix at existing place/site complete all as specified and as directed. Note: U/S copper scrape received from exhaust fan = Appx 100gm/Each taking down in schedule of credit.
S&F (On-Load) Changeover Switch with SS Enclosure Box (4 pole) I-0-II 100 Amp three phase HSN Code: 8536 barriers with handle with door interlock kit and aux contacts , with all reqire accessories lugs, gland and electrical connection complete all as specified and directed. Make : Havells Model: IHCNFE0100 or Equivalent
S& F Single pole and neutral enclosure box with two pin and earth plug and socket 240 Volts single phase complete with one single pole MCB 20 Amp and electric connection complete all as Specified and directed.
S&F MCB DB(distibution board) 8 Way SPN(single pole and neutral) double door with 200 amps rated bus bar made sheet steel cement spill protector , isolated neutral bar, IP:54 protection door earthing Mechanical impect strength IK 09, 240 volts and connection complete all as specified.
S&F MCB DB(distibution board) 12Way SPN(single pole and neutral) double door with 200 amps rated bus bar made sheet steel cement spill protector , isolated neutral bar, IP:54 protection door earthing Mechanical impect strength IK 09, 240 volts and connection complete all as specified.
S&F MCB DB(distibution board) 4Way TPN(triple pole and neutral) double door made sheet steel cement spill protector, isolated neutral bar, IP:54 protection door earthing Mechanical impect strength IK 09, 415 volts and connection complete all as specified.
Supply and fixing MCCB 3 Pole, 415 V, fixed type,125 Amps with breaking capacity 16 KA and current carrying capacity in with suitable DB fox fixing complete with connection testing and commissioning. complete all as specified and as directed.
Supply and fixing MCB TP 63 Amps 415V 10KA 'B' curve miniature circuit breaker (MCB) of poles and current carrying capacity in the DB complete with connection testing and commissioning. complete all as specified and as directed.
Supply and fixing MCB SPN 32 Amps 240V 10KA 'C' curve miniature circuit breaker (MCB) of double pole and current carrying capacity in the DB complete with connection testing and commissioning. complete all as specified and as directed.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) SP(single pole) and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioningcomplete all as specified and as directed.
M&L for New Earthing complete with galvanised iron plate earth electrode 600mm×60mm×6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, checknuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified including all excavation/ earth work in any type of strata, removal of surplus excavated material, GI pipe for watering and funnel, PCC 1:3:6 type C2 chamber with RCC 1:2:4 type B1 in cover slab with GI protection pipe but all as specified and directed by Engineer-in-Charge. all as specified or indicated including testing on completion and including taking down old earthing material. Note
Supply and lay pipes 25 mm galvanized iron, “Medium grade” GI tubing, including fittings laid in trenches fixed in floor / piller / walls and connection etc complete all as specified and directed.
Cutting existing GI steel tubing of 25-32 mm size for alterations or additions screwing existing steel tubing for alterations for alterations or additions (or lengthening screw on pipe to form connector) if necessarily done in position without taking down
Supply & fixing Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 25 MM dia with all fitting complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3½ core UG cable runinng on wall / floor/dcukt) including taking down old U/S UG cable
Boring holes 2 m deep in soil for under-reamed piles and getting out and disposal ofspoil to a distance of n exc.50 m
Supply and spreading soil in trenches as in cable cushioning all as per IS 1255-1983 and as directed. Note:- (i) Excavated approved soil shall be riddled by using sieve to sepaerate composite particles as per IS and refilling in trenches before laying of cable 8 cm and 15 cm after laying of cable, this is then gently punned down to a depth of 10 cm above the top of upper most cable (ii)For the purpose of measurement only punned thickness only will be considered for payment
M&L for burnt as class 'B' bricks a mechanical protection to under ground cables laying with length of the brick ezual to the width of the trench complete all as specified and directed by Engineer-in-Charge
Material and Labour for cement conrete foundations filling and mass concrete type B2 1:2:4, 40 mm grade crushed stome aggregate upto existing surface level or removing any type of tiles carefully and refixing properly as per existing surface complete all as specified and directed.
M&L for GI pipe light grade 40 mm size fixed on walls / alid in trenches as protection pipe for under ground cable including provisioning of specials and clamps protection on road crossings /plinth protection with fixed to the pole wall etc, complete all as specified and directed.
Demolition of cement concrete (unreinforced) any description and in any position not otherwise specifically provided for.
Taking down existing water proofing treatment with tar felt including cement plaster from roof surfaces such as and disposal of the rubbish from the premises beyond 250m complete all as specified and directed.
Dismantling floors hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete, all as specified and directed.
Taking up or down steel tubing including fittings for 15 mm bore pipe in any position (wall/ceiling/floor etc) complete, all as specified and directed.
Taking up or down steel tubing including fittings for 20 mm bore in any position(wall/ceiling/floor etc) complete, all as specified and directed.
Taking up or down steel tubing and connections 25mm dia complete all as specified and directed.
Taking down Chowkhat or frames not exceeding 1.5 Sqm each with shutters(Without taking off shutters from the frames) complete, all as specified and directed.
Taking down shutters of any description exceeding 1Sqm and not exceeding 2 Sqm each complete, all as specified and directed.
Taking down steel window/ventilators area n.exc 1.5 sqm each including all fittings and all as specified and directed.
Taking down cement plaster on walls any description including raking out joints, hacking for key and scrubbing down with water etc complete, Leakage/seapage testing shall be carried out before filling the brick bats by filling the water in sunken portion & checking complete, all as specified and directed.
M&L for Dismantling water tanks of capacity 1000 litre as directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.complete all as specified.
Taking down userviceable Ceiling fan/Wall mounted fan 400/1200/1400 mm Size remove sealing cable end, blades from site sent to market for make it serviceable with changing bearing/bush, capacitor, clamp, rubber bush, rewinding, repainting, servicing, re-write the MES No on fan & fix blades and Refixing to Existing place and connection complete all accessories as per site required and as directed by Engr-in-Charge.(Note :Quoted rates of items for taking down, servicing, repainting, refixing and electrical connection complete of Ceiling/Wall mounted fan all are inclusive in Each Job)
Removing building materials etc to a distance of exc 1.5 Km outside of MoD land or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination.
EURO ENTERPRISES
SREE BUILDERS
VARGHESECHACKO AND CO
AURA ENTERPRISES
SRI MAHALAKSHMI CONSTRUCTIONS
Maruthi constructions
D NAGI REDDY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .