Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l-1₹59,748.78Accepted-Finance | l-1 | Accepted-Finance AS PER BOQ | |
| 2 | l-2₹74,791.69+₹15,042.91 (25.2%)Accepted-Finance | l-2 | Accepted-Finance AS PER BOQ | |
| 3 | l-3₹85,690+₹25,941.22 (43.4%)Accepted-Finance | l-3 | Accepted-Finance AS PER BOQ |
Tender Value
₹42.4 L
EMD Value
₹31,777
Closing Date
2 Jun 2025, 5:30 pmClosed
Chief Municipal officer
Ashoknagar
Supply of electrical materials for the repair and maintenance of street lights as per the BOQ
2025_UAD_420942_1
Electrical/2025/1650 DT 02-05-2025
Open Tender
Electrical Goods/Equipments
Item Rate
30 days
Ashoknagar
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,000
₹31,777
11 Jun 2025
3 May 2025
4 Jun 2025
3 May 2025
2 Jun 2025
7 May 2025
Amount
Material List
T-5 POWER/ENERGY SAVER 2X24W CHOKE
T-5 POWER/ENERGY SAVER 24W FTL TUBEROD
2X24 T5-HOLDER
T5 POWER SAVER 2X24 FIXTURE ACRYLIC TRANSPARENT COVER
T5 POWER SAVER 4X24 FIXTURE ACRYLIC TRANSPARENT COVER
150W HPSV CHOKE
150W HPSV LAMP
CAPACITOR 33MFD 250VAC 50 Hz
ELECTRONIC IGNITOR SUITABLE FOR 150W HPSV LAMPS
150W holder
LED DRIVER 50W BIS CERTIFIED
LED MCPCB PLATE 50W
LED MCPCB PLATE 100W
LED MCPCB PLATE 150W
Supplyingof ISI Marked and approved make of Moulded Case Circuit Breaker(MCCB) suitable for 3phase,3pole,50Hz,415 Volts, AC supply with respective interrupting capacity(KA) at 415 Volts cited against their range standard conforming to IS - 8828: 8.1MCCB with Breaking Capacity 25 KA at 415 V: Current Rating -125 Amps & 70% -100% adjustable
Supply, installation, testing and commissioning of SOVP Device should have Single High Capacity Varistor in the L-N Plug and Encapsulated Spark Gap for N-PE, L-N SOVP should have a Rated Voltage of Minimum 320V AC to handle Indian Power Supply conditions. SOVP Should have Visual indication on replaceable varistor and spark gap modules as well as a potential free contact on the socket for remote indication. SOVP device should be wired up as per TT configuration of wiring in accordance with EN 61643-11 Standards. Both the L-N and N-PE, SPDs should be rated for handling 30KA of nominal 8/20 μs surge current.: SOVP for Pole Light Sub Feeder Panels - Type 2 Pluggable SPD 3+1, Rating L-N/N-PE Uc 255/320 V In 30/60KA KA, lmax 30Ka/60 KA, Up 1.5KV
Supplying of ISI Marked and accepted standard of Miniature Circuit Breaker(MCB)of'C'series suitable for 240/415Volts,50Cycle,10 Ka Value AC supply confirming to IS:8828:1996,IEC:60898 :2002 but without enclosures: SINGLE POLE 63 AMP.
ASTRONOMICAL TIMER WITH DST FEATURE
CONTACTOR 3 POLE 90 AMP 50HZ 415VOLTS WITH NO-NC CONTACTS
TPN connector 150A
Supply of approved make powder coated sheet steel encloser SPN MCB DB inclusive of Busbar,Neutral bar,Earth bar & two earth terminals etc. complete as per IS:13032 (exclusive of MCB & isolator): 8 way double door
Supply, installation, testing and commissioning of SOVP Device should have Single High Capacity Varistor in the L-N Plug and Encapsulated Spark Gap for N-PE, L-N SOVP should have a Rated Voltage of Minimum 320V AC to handle Indian Power Supply conditions. SOVP Should have Visual indication on replaceable varistor and spark gap modules as well as a potential free contact on the socket for remote indication. SOVP device should be wired up as per TT configuration of wiring in accordance with EN 61643-11 Standards. Both the L-N and N-PE, SPDs should be rated for handling 30KA of nominal 8/20 μs surge current.: SOVP for Pole Light - Type 2 Pluggable SPD 1+1, Rating L-N/N- PE Uc 230/400 V In 5 KA, Imax 10 KA, Up 1.2KV
LED BATTEN TUBELIGHT 20W
Supplying of approved make TPN MCBDB Metal Double Door with provision for FPMCB/Isolator/RCCB/RCBO as incomer and SP MCBs as outgoing inclusive of Busbar,Neutral bar,Earth bar & two earth terminals etc. complete as per IS:13032 (exclusive of MCB & isolator ): 8 way (8+24)
8 SQ.MM MULTISTRAND PVC INSULATED COPPER WIRE BUNDLE 90MTR
1.SQ.MM ALUMINIUM SINGLE CORE WIRE BUNDLE OF 100MTR. ISI MARKED
XLPE INSULATED POWER CABLE( CONFORMING IS-7098 PART-1) 1100 VOLT GRADE 2-CORE ISI MARKED WITH ALU. STRANDED/SOLID CONDUCTOR: 16 SQ.MM UNARMOURED
XLPE INSULATED POWER CABLE( CONFORMING IS-7098 PART-1) 1100 VOLT GRADE 4-CORE ISI MARKED WITH ALU. STRANDED/SOLID CONDUCTOR: 16 SQ.MM UNARMOURED
XLPE INSULATED POWER CABLE( CONFORMING IS-7098 PART-1) 1100 VOLT GRADE 1-CORE ISI MARKED WITH ALU. STRANDED/SOLID CONDUCTOR: 25SQ.MM UNARMOURED
WOODEN LADDER 21ft
TOOLKIT SET CONSISTING OF DIFFERENT SIZES L-KEYS, SCREW DRIVERS, TESTERS AND PLIER SET.
TAPEROLL BOX CONSISTING OF 30PCs (Conforms to IS: 7809 (Part 3, Sec 1),Self extinguishing,Protects from electrolytic corrosion,Excellent water resistance,Suitable for primary insulation up to 440V)
SHRI BANKE BIHARI CONSTRUCTION (BID ID -1267085)
NAVYA BUILDERS (BID ID -1267348)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .