Executive Engineer Construction Division Leh
OOffice of the Executive Engineer Construction Division Leh
Annual maintenance contract for undertaking electrical works in various Govt. Building, Quarters and within the Jurisdiction of Construction Division Leh for the year 2025-26, 2026-27.
2025_PWD_18245_1
152 of CDL Leh of 2025-26
Open Tender
Electrical Works
720 days
leh
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Executive Engineer Construction Division Leh
₹61,700
11 Apr 2026
30 Dec 2025
21 Jan 2026
31 Dec 2025
20 Jan 2026
31 Dec 2025
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
c) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
d) 2 X 10 sq. mm + 1 X 6 sq. mm earth wire
e) 2 X 16 sq. mm + 1 X 6 sq. mm earth wire
f) 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
g) 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
h) 4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. Group C
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a) 1 x 1.5 sq. mm
b) 2 x 1.5 sq. mm
c) 2 x 2.5 sq. mm
c)2 x 4 sq. mm
d)2 x 6 sq. mm
e)4 x 4 sq. mm
f) 4 x 6 sq. mm
g) 3 x 1.5 sq. mm
h) 3 x 2.5 sq. mm
i) 3 x 4 sq. mm
j) 6 x 6 sq. mm
k) 3 x 6 sq. mm
l) 6 x 4 sq. mm
Supplying and fixing of LED batten tube fitting 1200mm size 20 watt LL-20-111-XXX-65E NE3 Wipro or equivalent
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing of LED batten tube fitting 600mm size 10/12 watt
Supplying of LED batten tube fitting 1200mm size 20 watt
Supplying and fixing of LED batten tube fitting 1200mm size 20 watt
Supplying of ceiling fan of double ball bearing type, 1200mm sweep with 2.25 mfd condenser and one foot down rod on the existing fan hook with necessary connection from ceiling rose to fan using twin core copper wire. (5 Star).
Supplying and fixing of ceiling fan of double ball bearing type, 1200mm sweep with 2.25 mfd condenser and one foot down rod on the existing fan hook with necessary connection from ceiling rose to fan using twin core copper wire. (5 star). Preferred Make:- CG entrust 50 USHA trump or equivalent
Supplying of following sizes heavy duty exhaust fan with metal blade complete set on existing holes on wall with necessary connection from ceiling rose to fan using 2 core flexible copper wire a) 225 mm / 9" sweep exhaust fan
b) 300mm/12" sweep exhust fan
Supply and fixing of fan hook (U hook) on celiling with 2 nos. of anchor fastener on both ends with necessary bolts and nuts and mansonry work as required.
Supplying of following sizes extra down rod with twin core flexible copper wire for ceiling fan. 1'0"
Supplying of following sizes extra down rod with twin core flexible copper wire for ceiling fan 1-6"
Supplying and fixing of following sizes (oscillating type) wall mounting fan on wall with necessary connection. 400 mm Sweep Wall mounting fan
Supplying and fixing of 400 mm sweep pedestal mounting fan including transporting, assembling and put into service
Supplying and fixing of 32 amp switch socket complete with base plate and cover of AC
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. A) Single pole
b)Single pole and neutral
c) Double pole
d) Triple pole
e) Triple pole and neutral
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. A) SPN 40 Amp
b) SPN 63 Amp
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) TPN 40 Amp
b) TPN 63 Amp
c) TPN 100 Amp
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 25 A
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 25 A
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 6 way , Double door
b) 8 way , Double door
c) 12 way , Double door
d) 16 way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 4 way (4 + 12), Double door
b) 6 way (4 + 18), Double door
c) 8 way (4 + 24), Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) a) 4 way (4 + 12), Double door
b) 8 way (4 + 24), Double door
c) 12 way (4 + 36), Double door
Supplying & laying of 0.51 mm dia two pair PVC telephone cable with suitable size PVC pipe/ casing and capping on the wall with painted G.I Clamps.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 25 mm PVC pipe
b) 25 mm PVC pipe
c) 40 mm PVC pipe
d) Deep Box
e) Fan Box
Supplying and fixing of PVC Casing and Caoing along with accessories of following sizes. A) 20mm
Providing and fixing of following electrical accessories for replacement as and when required during the contract period. a) 1200mm x 36/40W fluorescent tub
b) 36/40W Starter
c) 36/40W electronic ballast
d) Tube Light Holder
e) 4 pin 36 watt CF
Providing of LED Bulbs. A) 9W
Providing and fixing of LED Bulbs. A) 9W
Supplying and fixing of Surface mounted/recessed mounted circular holes etc as required. LED Light of rating including cutting of holes etc as required. A) 6W
Supplying and fixing of 3 mm Phenolic Sheet.
Supplying, installation, testing and commissioning of LED 600 mm x 600mm recess mounted fixture that delivers at least 3600 lumens and wattage not more than 36 watt. The luninaire shall have CRCA powder coated body and a high efficiency diffuser. The power factor > 0.09 and a THD 10% RC 380B LED 365-6500 G4 L60 W60 PSU OD of philips, WIPRO CRCO10 RO38HP57GL OR equivalent approved make
Supplying and fixing of LED Street light of following wattage extra as required the rating (IP66) a) 45W WIPRO LR-02-501-XXX-57- or equivalent approved make.
b) 70 w WIPRO LR-02-781-XXX-G2-or equivalent approved make.
Supplying and fixing of 120 watt LED Street Light complete with GI pipe bracket duly embeded along the parapet/wall. Wipro LR02-132-XXX-57-G2 or equivalent approved make
Providing and fixing of following accessories a) 5/6Amp. 3 pin Top
b) 5/6Amp 2 pin Top
c) 15/16 Amp 3pin Top
Insulation Tape (ISI brand)
Electronic Step Type fan Regular
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/wooden block including connections etc. As required.
2.2/3/3.5 mfd fan condenser
Pendent Holder (Brass)
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. A) 1 or 2 Module (75mmX75mm)
b) 3 Module (100mmX75mm)
c) 4 Module (125mmX75mm)
d) 6 Module (200mmX75mm)
e) 8 Module (125mmX125mm)
f) 12 Module (200mmX150mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. A) 1 or 2 Module
b) 3 Module
c) 4 Module
d) 6 Module
e) 8 Module
f) 12 Module
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. A) 5/6 amps switch
b) 2 way 5/6 A switch
c) 15/16 A switch
d) 3 pin 5/6 A socket outlet
e) 6 pin 15/16 A socket outlet
f) Telephone socket outlet
g) TV antenna socket outlet
h) Bell push
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. A) 5/6 A switch
b) 2 way 5/6 A switch
c) 15/16 A switch
d) 3 pin 5/6 A socket outlet
e) 6 pin 15/16 A socket outlet
f) Telephone socket outlet
g) TV antenna socket outlet
h) Bell push
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing of single phase motar of following rating self pumping priming for pumping water including connections etc as required. A) 0.5 HP
Rewinding of the following fans using enameled copper wire of required gauage, varnishing oiling greasing etc. overhauling such as cleaning, replacement of same size and rating of bearing condenser, cotter pins, shackle insulator, twin core copper wire and other defective materials required for making the fan in good working condition. The cost should inculde the rebate of old enameked copper and material. The guarantee of the fan after rewinding should be one year from the date of installation. The workmanship shall be Grade A and up to the satisfaction of the Engineer in charge. 1200mm/1400mm sweep AC ceiling fan
P/F 300mm sweep exchaust fan
Rewinding of 1 phase (0.5HP) motor for water lifting
Rewinding of 1 phase 1HP) motor for water lifting
Overhauling the ceiling fan / exhaust fan and supplying and replacing the same size and rating of bearing, condenser, cotter pins, shackle insulator, twin core copper wire and other defective material required for making the fan in good working condition.
Supplying and replacement of the suitable size and rating of the following in the storage water heater and making the geyser in good working condition. Heating Element
Thermostat with Control
Assembly
Supplying of single pole blanking plate in the existing MCB DB Complete etc. as required (modular)
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. a) 100 A,30KA,FPMCCB
b) 125 A,36KA,FPMCCB
c) 200 A,36KA,FPMCCB
d) 250 A,36KA,FPMCCB
e) 250 A,50KA,FPMCCB
f) 400 A,50KA,FPMCCB
Providing of PCB in wall fans (Remote control type) having sweep 400 mm
Supply of Distilled water required for the Battries
Supply and fixing following units bells.
Bell conttrolled by Single remote
Bell controlled by Double Remote
Call bell / Ding Dong, Single phase
Call Burzer
Supplying of following PVC Gang Box. A) One way
b) Two way
g),1+1 way power)
Supplying and fixing of following sizes PVC sheathed XLPE insulated Aluminium conductor cable including connections etc as required. A) 10 Sq.mm Twin Core Un-armoured
b) 16 Sq.mm Twin Core Un-armoured
c) 16 Sq.mm 4 Core Armoured
d) 35 Sq.mm 3.5Core Armoured
e) 50 Sq.mm 3.5 Core Armoured
f) 70 Sq.mm 3.5Core Armoured
g) 95 Sq.mm 3.5 Core Armoured.
h) 120 Sq.mm 3.5 Core Armoured.
i) 150 Sq.mm 3.5 Core Armoured.
Supplying and fixing following items. Make Microtake, Lumunious and equivilant etc a) Invertor Sinewave 850 VA
b) Invertor Sinewave 1400 VA
c) Invertor Sinewave 2000VA Cruze
Repair to PCB Invertor 850 VA
Repair to PCB Invertor 1400 VA
Replacement to PCB Invertor 850 VA
Replacement to PCB Invertor 1400 VA
Supply and installation of Battery 12 Volt. Tubular 120-135 AH
Supply and installation of Battery 2 Volt. Tubular 100-200 AH
Supply and installation of Battery 12 Volt. Tubular 150 AH
Supplying testing and commissioning of 10KVA UPS inculding battery bank and all accessiories complete job.
Supplying testing and commissioning of 15KVA UPS inculding battery bank and all accessiories complete job.
Supplying testing and commissioning of 20KVA UPS inculding battery bank and all accessiories complete job.
Supplying testing and commissioning of 30KVA UPS inculding battery bank and all accessiories complete job.
Providing and fixing of suitable size GI Pipe Bracket for 25 to 70 watt LED Street Light Fitting.
Supplying and installation of heating blower (make Usha/CG equivilant)
Supplying and instalation of pillar heater (make Gopi equivilant)
Supplying and installation of helogen type 3 tube maharaja padestrim heater.
Supplying and installation of of Rod Type Room Heater Single Rod
Double Rod
Supply of electric Kettle of following capacity. A) 0.75 Ltrs
b) 1.00 Ltrs
Repair of electric Kettle of following capacity. A) 0.50 Ltrs
b) 0.75 Ltrs.
c) 1.00 Ltrs
Repair to the exchange of intercom system by way of replacing the damaged/mulfunctional parts etc as required.
Supplying and fixing of following rating type automatic voltage stabilizer 90-29 V range copper bound for AC/ Water cooler. A) 4 KVA
Repair of Automatic Voltage Stabilizer by way of copper winding etc as required. upto 3 KVA
Above 3KVA ro 5 KVA
Above 5 KVA to 6 KVA
Repair of automatic voltage stabilizer by way of replacement of damaged relays/circuits etc as required. Upto 6 KVA
Supply of Electric Tool Kit (All in one hand Tool Kit, Make Top Tool and equivilant).
Labour charge (2 wireman and 2 helper) for rectification of fault in panel boards, all kinds of light fittings, fans equipments and all electrical accessories and making them in good working condition.
Supplying of 12 Volt (7AH) UPS Battery
Repair to the UPS installed with computer
Supply, installation, testing & commissioning of GI Electrode Earthing with 84mm dia and 3 meter length, with 3mm thick the electrode should be hot dip galvinised. The GI Electrode shall be pre filled with cristaline Conductive Material (CCM) The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact between the electrode and compound should be eco friendly GI Electrode Earthing should be eco friendly GI Electorde Earthing should be maintinance free and does not require regular manual addition of water. The earthing pit should be covered with PVC cover.
Supply, installation, testing and commissioning of GI electrode earting with 50mm dia and 3 meter length. with 3 mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with cristaline conductive materila (CCM). The GI electrode and compound to provide maximum contact between the electroded and compound should be eco friendly and having ROHS certificaatiGI electrode eathing should be maintinance free and foes not required regular manual addition of water GI electrode shall be tested from CPRI. The earthing pit shoujld be covered with PVC cover
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced etc.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
Repair to room heaters by ay of replacing damaged elements, pins etc as required. A) Single Rod
b) Double rod
c) Helogen type
d) Gopy
e) Heat convector
Supplying and fixing of Bus bar chamber with 3 phase bus bar 300 Z (size 2'-6"x2" X 6")
Illumination of building on the eve of independence day/Republic day for three days. On rental basis
Fabrication, supplying, installation, testi ng and commissioning of following panel made out of 2 mm thick M.S sheet wall/floor mounted vermin and dust proof,out door type with located type hinged doors, duly painted with provision for fixing Incoming/outcoming potention equipements as received at site including supply and fixing of set of Aluminium Bas bar and strip for housings MCBS as required.
Supply and Fixing changeover switch along with MS box 4 pole (handle Type) of following types a) 100 A
Supply and fixing heating Gysers of following ratings/Capacity a) 15 Ltr
Dismentling of existing old LT panel after disconnecting all cables, wires etc and shifting at desired place as required
Dismentling of existing aluminium cabels, copper cables and shifting at desired place as required at site
Reconnection of aluminium/copper cabels to new panel by enggaging skilled labours
Labour charcge (2 wire man and 2 helper) for rectification of fault in panel boards, all kinds of light fittings, fans equipments and all electrical accessories and making them in good working condition.
Supplying and fixing of Hot and Cold AC 3/4 star inverter and compressor completed set (1.5 tone)
Supplying and fixing of Hot and Cold AC 3/4 star inverter and compressor completed set (2 tone)
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.66 MB
BOQ_44056.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid