| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.0 LAccepted-AOC BHAVANI KRUPA GANDHI CHOWK NAGPUR | NAGPUR | NAGPUR | MAHARASHTRA | 442302 | L1 | Accepted-AOC Being Lowest and quoted rates are reasonable | |
| 2 | L2₹32.0 L+₹1.0 L (3.37%)Rejected-Finance 40 6 UKHARA PO PRATAP PURA AGRA UP 282001 | AGRA | AGRA | UP | 282001 | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹32.7 L+₹1.7 L (5.45%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹33.2 L+₹2.2 L (7.06%)Rejected-Finance PULGAON | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹34.7 L+₹3.7 L (11.8%)Rejected-Finance | L5 | Rejected-Finance Other than Lowest |
Tender Value
Refer Docs
EMD Value
₹60,360
Closing Date
6 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PULGAON
GE PULGAON CAD CAMP
PROVN OF OVERHEAD SHELTER FOR STATION MAIN GATE AT CAD PULGAON
2023_MES_575277_1
9060/PUL/E8
Open Tender
Civil Works
Item Rate
180 days
GE PULGAON
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE PULGAON
₹60,360
Yes
22 Feb 2023
16 Jan 2023
13 Feb 2023
16 Jan 2023
6 Feb 2023
31 Jan 2023
16 Jan 2023 - 30 Jan 2023
Amount
Excavating in post holes (or similar holes) each n.exc 0.50 cum getting out complete all as specified and as directed.
M&L for cement concrete 1:1(1/2):3 volumetric nominal mix (using 20mm graded aggregate) as in foundation ,footing filling and mass concrete complete all as specified and as directed.
S & F for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 and above complete all as specified and directed. (Note-1: Fabrication in required shape & size shall be done at factory site only) (Note-2: If tubes available in market is of higher St. then specified above, the same shall be provided by the contractor without any extra cost) Make: Tata / Jindal / Apollo
S & F for Steel work in tubular trusses in semi circular or ornamental and intricate design including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 and above complete all as specified and directed. (Note-1: Fabrication in required shape & size shall be done at factory site only) (Note-2: If tubes available in market is of higher St. then specified above, the same shall be provided by the contractor without any extra cost) Make: Tata / Jindal / Apollo
S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe 410 -W (GdeE- 250) qualityA complete all as specified and as directed. (Note Fabrication should be done at factory made only)
M & L for Preparation of new steel surface of any description over 10cm in width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
S & F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; will ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe410-0 or Fe 310-0. complete all as specified and as directed.
S&F for MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410 -W (Gde- E- 250) quality- A complete all as specified and as directed.
S&F for Mild steel screw bolts (machine made) diameter of neck in16 to 20 mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 10cm to n.exc 15cm long complete all as specified and as directed.
S&F for Mild steel bolts purpose made with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. Exc 30cm long complete all as specified and as directed.
S&F Pre-painted galvalume aluminium zinc coating GI based (corrugated/ semi corrugated) crimple sheet 0.50mm thick for semi circular shed as per approved profile, coloured, having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S & F 1mm thick Plain galvanised mild steel sheeting, with zinc coating @275 grams per sqm in valley gutter with 150mm lap joint water proof as directed cut to size and bent to shape turning up and down including stopped end punching holes and making with head screws to stopped with bitumen washers all as specified (length and girth as fixed) with grade of zinc coating 275. complete all as specified and as directed.
S & F 110mm PVC (SWR) rain water pipes single socketed in any length with rubber ring joints fixed to walls/structural steel frame complete all as specified and as directed.
S & F 110mm PVC (SWR) bend any radius complete all as specified and as directed.
Writing letters or figures (Block, Roman, Italic or Indian) n exc 30 cm high on board,wall etc. complete all as specified and as directed.
M & L for 3D stainless steel writing letters height n,exc 30cm ( Hindi/ English) including welding,riveting and fixing complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L PCC 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and as directed.
M&L for hydraulic machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 100 mm thickness M-50 Grade including 50mm sand cushioning complete all as specified and as directed.
M& L for Providing, Plain cement concrete type B-1, 1:2:4 (using 20 mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed.
M&L for Cement concrete work in pavement/ hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less complete all as specified and as directed.
Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level additional 50 m or part thereof beyond 50 m and upto a total distance of 250 m.above the starting point complete all as specified and directed.
M&L Reinforced concrete pipes 600 mm dia, class NP 3 with one collar per length of pipe complete all as specified and as directed.
Demolition of brick /stone masonary built in cement mortar including all quoins arches, pillars and precast concrete articles all as specified and as directed.
M&L for RCC Type B-1 , 1:2:4 (using 20 mm graded stone aggregate) Beams, cantilevers, bressummers lintels over 1.5m span complete.
M & L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:3 complete all as specified and as directed.
M&L Rendering 15mm thick on fair faces of brick work or concrete surfaces on cement mortor 1:3 fair finished even and smooth with out using extra cement complete all as specified and as directed.
M&L for preparation of new or old plastered surfaces of wall and applying two coats of cement base paint over a coat of primer complete all as specified and as directed.
M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L Mild steel TMT bars 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for point wiring with stranded copper conductor 2.5 Sqmm (Nominal Area) Single core, Multistranded, FRLS , PVC insulated and unsheathed cable FRLS 1100 volts grade mult stranded for earth, ISI marked drawn in and including PVC casing caping of suitable size with accessories ISI marked including PVC insulated copper cable for earth of same type and sized connected earth dolly including provision of PVC box of suitable size for mounting one light point controlled by one MCB complete all as specified and as directed.
Supply and fix LED Flood light 70W 230 Volts AC outdoor type with thermal management in multiple optics and equipped with IP 66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 2 core.complete all as specified and as directed.
Supply and lay pipe galvanized, “Medium class”, including fittings 25 mm dia (Cable Protection Pipe). complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25M deep below ground level) with top edge of the plate not less than 1.5 M below ground level connected with galvanised earth wire 4 mm dia by means of bolts nuts check nuts and washers of galvanised iron to earth test point all as specified or indicated including necessary excavation and earth work any type of soil PCC (1:3:6) watering funnel with wire mesh, GI tubing 20 mm medium grage for watering, 15mm bore light grade for GI Protection, Charcole and salt in requisited quantity complete all as specified and directed and all as shown in electrical plate No.3 of SSR part 1. Note: GI earth wire and protection pipe upto 7.5m in length shall be included in quoted rate.
S and F of sheet steel enclosure with double door flush mounting ,MCB, DB, SPN, 8 ways,240 volt factory fitted rated bus bars,earth bar,neutral links complete including. blanking plates as required and making good the disturbed surfaces. complete all as specified and as directed.
S and F of MCB SPN 20 to 32Amps 240V ,50 Hz, breaking capacity 10 KA," C " series all as directed. MAKE: Havells/Standard/Indoasian
S&F MCB SP 6-32 Amps 240V ,50 Hz, breaking capacity 10 KA," C " series complete all as specified and as directed. MAKE: Havells/Standard/Indoasian
M&L sub main wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in PVC Casing caping of 2 run of 2sqmm PVC FRLS copper cable and 1run of 1.5sqmm PVC FRLS copper cable for earth wire complete all as specified and directed. Note for sub main wiring :- (i) 2 runs of wire and 1 run of earth wire will be measured as one unit i.e RM (ii) Groove Cutting ,pinning and plastering of disturbed surface etc shall deemed to be included in the quoted rate.wiring 2 run of wire and1 run of earth wire
Excavation in trenches not exc 1.5m wide and not exc 1.5M depth for laying of cables,GI/CI pipe lines etc getting out including forming bottom surface to required level and gradient in hard/dense soil.complete all as specified and directed.
M&L for Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm in hard/dense soil. complete all as specified and directed.
Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and directed.
Material and labour for sand cushioning with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming completed all as specified and directed. Note : Punned thickness only shall be measured and paid.
Supply and lay un-reinforcement precast concrete cable cover, class LV, type 2, flat of size 300 X 180 X 40mm for HT cable and laid dry in trenches over underground cables complete all as specified and directed
Attar Singh and Sons
Chhabra Enterprises
M/S Maa Durga Constructions,Pulgaon
M/s Prakash Agencies
SHUBHAM SALES
M/S JAI BHAWANI CONSTRUCTIONS
SHRI RANI SATI TRADERS
RAJ ENTERPRISES
Bidder Name
Attar Singh and Sons
RAJ ENTERPRISES
SHRI RANI SATI TRADERS
M/s Dara Constructions, Pulgaon
M/S Maa Durga Constructions,Pulgaon
M/s Prakash Agencies
M/S JAI BHAWANI CONSTRUCTIONS
SHUBHAM SALES
Chhabra Enterprises
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .