SSE (W) Akola Jurisdiction - Proposal for Provision of Heavy repairs to Platform surface , Drainage system, water supply, Cover shed of Service building and Platform at Akola railway station.(Rev : 2026-27)
DRMWBSL212026t2
DRMWBSL212026t2
Open
9 Months
Akola, Maharashtra
₹0
₹3.7 L
23 Jun 2026
23 Jun 2026
3 Jul 2026
Cover shed of Service building and Platform at Akola railway station.(Rev : 2026-27)
Item- 1 DSR-2023 Items
S No. Item No Description of Item Unit Qty Rate Amount
1.0 CARRIAGE OF MATERIALS
By Manual Labour including loading, unloading
and stacking for lead less than 0.50 KM
1.2.1 Lime, moorum, building rubbish
1.2.1.1 Cost of carriage including loading, unloading & cum 710 227.18 161297.8
stacking for first 50 metres
1.2.1.2 Every additional lead of 50m or part thereof cum- 6390 49.47 316113.3
beyond1st 50 m upto 9 such additional lead lead
2.0 EARTH WORK
2.1S General
BHUSAWAL DIVN-ENGINEERING/CENTRAL RLY
Earth work in excavation by mechanical means
(Hydraulic excavator)/manual means over areas
(exceeding 30 cm in depth, 1.5 m in width as
2.6 well as 10 sqm on plan) including getting out
and disposal of excavated earth lead upto 50 m
and for all lift, as directed by Engineer-in-
4.0 CONCRETE WORK
4.1S CEMENT CONCRETE (CAST IN SITU)
Providing and laying in position cement
concrete of specified grade excluding the cost of
centering and shuttering - All work up to plinth
including manufactured sand derived from
Recycled Concrete Aggregate (RCA) upto 25% :
4 graded stone aggregate 20 mm nominal size
including Recycled Concrete Aggregate (RCA)
5.0 REINFORCEMENT CEMENT CONCRETE
5.1S CAST IN SITU
Providing and laying in position specified grade
of reinforced cement concrete, excluding the
cost of centering, shuttering, finishing and
reinforcement - All work up to plinth level :
manufactured sand derived from Recycled
5 Concrete Aggregate (RCA) upto 20% : 4 graded
stone aggregate 20 mm nominal size of
Recycled Concrete Aggregate (RCA) upto 20%).
6.0 MASONRY WORK
6.1S General
Brick work with common burnt clay F.P.S. (non
6.1 modular) bricks of class designation 7.5 in
foundation and plinth in:
8.0 CLADDING WORK
8.1S General
Providing and fixing 18 mm thick gang saw cut,
mirror polished, premoulded and prepolished,
machine cut for kitchen platforms, vanity
counters, window sills, facias and similar
locations of required size, approved shade,
colour and texture laid over 20 mm thick base
cement mortar 1:4 (1 cement : 4 coarse sand),
joints treated with white cement, mixed with
matching pigment, epoxy touch ups, including
rubbing, curing, moulding and polishing to
edges to give high gloss finish etc. complete at
8.2.2 Granite stone slab colour black, Cherry/Ruby red
Stone tile (polished) work for wall lining over 12
mm thick bed of cement mortar 1:3 (1 cement :
3 coarse sand) and cement slurry @ 3.3 kg/sqm
including pointing in white cement complete.
8.9.1 8 mm thick
8.9.1.1 Raj nagar plain white marble/ Udaipur green Sqm 60 3190.3 191418
marble/ Zebra black marble
9.0 WOOD AND P.V.C. WORK
9.1S FRAMES AND TRUSSES
BHUSAWAL DIVN-ENGINEERING/CENTRAL RLY
Providing and fixing ISI marked flush door
shutters conforming to IS : 2202 (Part I)
decorative type, core of block board
9.20 construction with frame of 1st class hard wood
and well matched teak 3 ply veneering with
vertical grains or cross bands and face veneers
on both faces of shutters.
9.20.2 30 mm thick including ISI marked Stainless Sqm 15 3167.95 47519.25
Steel butt hinges with necessary screws
9.23 Extra for providing lipping with 2nd class teak Sqm 15 462.35 6935.25
wood battens 25 mm minimum depth on all
edges of flush door shutters (over all area of
door shutter to be measured).
9.40S MISCELLANEOUS-WOOD WORK
Providing and fixing M.S. grills of required
pattern in frames of windows etc. with M.S.
9.48 flats, square or round bars etc. including
priming coat with approved steel primer all
9.48.2 Fixed to openings /wooden frames with rawl Kg 700 238.35 166845
plugs screws etc.
COPER OXIDISED MILD STEEL FITTINGS (COPPER
OXIDISED AS PER IS: 1378)
Providing and fixing ISI marked oxidised M.S.
9.62 sliding door bolts with nuts and screws etc.
complete (Copper oxidised as per IS 1378)
9.105S GYPSUM BOARD PARTITIONS
9.121 Providing and fixing Fiber Glass Reinforced Metre 160 570.95 91352
plastic (FRP) Door Frames of cross-section 90
mm x 45 mm having single rebate of 32mm x
15 mm to receive shutter of 30 mm thickness.
The laminate shall be moulded with fire
resistant grade unsaturated polyester resin and
chopped mat. Door frame laminate shall be 2
mm thick and shall be filled with suitable
wooden block in all the three legs. The frame
shall be covered with fiber glass from all sides.
M.S. stay shall be provided at the bottom to
steady the frame.
9.122 Providing and fixing to existing door frames.
9.122.1 30 mm thick Glass Fibre Reinforced Plastic (FRP) Sqm 10 3720.75 37207.5
panelled door shutter of required colour and
approved brand and manufacture, made with
fire - retardant grade unsaturated polyester
resin, moulded to 3 mm thick FRP laminate for
15 forming hollow rails and styles, with wooden
frame and suitable blocks of seasoned wood
inside at required places for fixing of fittings,
cast monolithically with 5 mm thick FRP
laminate for panels conforming to IS: 14856,
including fixing to frames.
10.0 STEEL WORK
10.1S General
10.2 Structural steel work riveted, bolted or welded Kg 1500 133.7 200550
in built up sections, trusses and framed work,
16 including cutting, hoisting, fixing in position and
applying a priming coat of approved steel
primer all complete.
Steel work in built up tubular (round, square or
rectangular hollow tubes etc.) trusses etc.,
including cutting, hoisting, fixing in position and
applying a priming coat of approved steel
primer, including welding and bolted with
special shaped washers etc. complete.
BHUSAWAL DIVN-ENGINEERING/CENTRAL RLY
Steel work welded in built up sections/ framed
work, including cutting, hoisting, fixing in
10.25 position and applying a priming coat of
approved steel primer using structural steel etc.
10.25.2 In gratings, frames, guard bar, ladder, railings, Kg 1000 172.6 172600
brackets, gates and similar works
10.28 Providing and fixing stainless steel ( Grade 304) Kg 300 772.4 231720
railing made of Hollow tubes, channels, plates
etc., including welding, grinding, buffing,
polishing and making curvature (wherever
required) and fitting the same with necessary
stainless steel nuts and bolts complete,
including fixing the railing with necessary
19 accessories & stainless steel dash fasteners ,
stainless steel bolts etc., of required size, on the
top of the floor or the side of waist slab with
suitable arrangement as per approval of
Engineer-in-charge, (for payment purpose only
weight of stainless steel members shall be
considered excluding fixing accessories such as
nuts, bolts, fasteners etc.).
11.0 FLOORING
11.16S TILE FLOORING
Tile work in skirting, risers of steps and dado up
to 2 m height over 12 mm thick bed of cement
mortar 1:3 (1 cement :3 coarse sand) and
jointed with grey cement slurry @ 3.3 kg/sqm,
including pointing in white cement mixed with
pigment of matching shade complete.
11.22.1 Marble tiles (polished) Raj Nagar
11.41S VITRIFIED FLOOR TILES
Providing and laying Vitrified tiles in floor in
different sizes (thickness to be specified by the
manufacturer) with water absorption less than
0.08% and conforming to IS:15622, of approved
brand & manufacturer, in all colours and shade,
laid on 20 mm thick cement mortar 1:4 (1
cement: 4 coarse sand) jointing with grey
11.41A cement slurry @3.3 kg/sqm including grouting
t h e joints with white cement and matching
pigments etc. The tiles must be cut with the
zero chipping diamond cutter only . Laying of
tiles will be done with the notch trowel, plier,
wedge, clips of required thickness, leveling
system and rubber mallet for placing the tiles
gently and easily.
11.41A.1 Double charge vitrified tile polished finish of size
11.41A.3 Glazed Vitrified tiles Matt/Antiskid finish of size
Providing and laying flamed finish Granite stone
flooring in required design and patterns, in
linear as well as curvilinear portions of the
building all complete as per the architectural
drawings with 18 mm thick stone slab over 20
mm (average) thick base of cement mortar 1:4
(1 cement : 4 coarse sand) laid and jointed with
cement slurry and pointing with white cement
slurry admixed with pigment of matching shade
including rubbing, curing and polishing etc. all
complete as specified and as directed by the
Engineer-in-Charge :
11.55.1 Flamed finish granite stone slab Jet Black, Sqm 3400 3186.7 10834780
Cherry Red, Elite Brown, Cat Eye or equivalent.
12.0 ROOFING
BHUSAWAL DIVN-ENGINEERING/CENTRAL RLY
12.1S SHEET ROOFING
12.11 Extra for providing and fixing wind ties of 40x 6 Metre 150 195.6 29340
mm flat iron section.
12.37S RAIN WATER SPOUT AND PIPE
Providing and fixing on wall face unplasticised
Rigid PVC rain water pipes conforming to IS :
12.41 13592 Type A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm gap for
thermal expansion, (i) Single socketed pipes.
Providing & fixing UV stabilised fiberglass
reinforced plastic sheet roofing up to any pitch,
including fixing with polymer coated 'J' or 'L'
hooks, bolts & nuts 8 mm dia. G.I plain/bitumen
washers complete but excluding the cost of
purlins, rafters, trusses etc. The sheets shall be
manufactured out of 2400 TEX panel rovings
incorporating minimum 0.3% ultra-violet
stabiliser in resin system under approximately
2400 psi and hot cured. They shall be of uniform
pigmentation and thickness without air pockets
and shall conform to IS 10192 and IS 12866.The
sheets shall be opaque or translucent, clear or
pigmented, textured or smooth as specified.
step-down (2" or 3" or 6" ) as specified
12.50 Providing and fixing precoated galvanised iron Sqm 1500 738.65 1107975
profile sheets (size, shape and pitch of
corrugation as approved by Engineer-in-charge)
of total coated thickness 0.50 mm (base metal
of minimum 0.45 mm thickness with total
coating thickness of 0.05 mm) with zinc coating
120 grams per sqm as per IS: 277, in 240 mpa
steel grade, 5-7 microns epoxy primer on both
side of the sheet and polyester top coat 15-18
microns. Sheet should have protective guard
film of 25 microns minimum to avoid scratches
during transportation and should be supplied in
single length upto 12 metre or as desired by
Engineer-in-charge. The sheet shall be fixed
using self drilling /self tapping screws of size
(5.5x 55 mm) with EPDM seal, complete upto
any pitch in horizontal/ vertical or curved
surfaces, excluding the cost of purlins, rafters
and trusses and including cutting to size and
shape wherever required.
BHUSAWAL DIVN-ENGINEERING/CENTRAL RLY
Providing & fixing false ceiling at all height
including providing & fixing of framework made
of special section, power pressed from M.S.
sheets and galvanised with zinc coating of 120
gms/ sqm (both side inclusive) as per IS : 277
and consisting of angle cleat of size 25 mm wide
x 1.6 mm thick with flanges of 27 mm and 37
mm, at 1200 mm c/c, one flange fixed to the
ceiling with dash fastener 12.5 mm dia x 50 mm
long with 6 mm dia bolts, other flange of cleat
fixed to the angle hangers of 25 x10 x0.50 mm
of required length with nuts & bolts of required
size and other end of angle hanger fixed with
intermediate G.I channels 45 x15 x 0.90 mm
running at the spacing of 1200 mm c/c, to which
the ceiling section 0.5 mm thick bottom wedge
of 80 mm with tapered flanges of 26 mm each
having lips of 10.5 mm, at 450 mm c/c, shall be
fixed in a direction perpendicular to G.I
intermediate channel with connecting clip made
out of 2.64 mm dia x 230 mm long G.I wire at
12.59 every junction, including fixing perimeter
channels 0.50 mm thick 27 mm high having
flanges of 20 mm and 30 mm long, the
perimeter of ceiling fixed to wall/ partitions with
the help of Rawl plugs at 450 mm centre, with
25 mm long dry wall screws @ 230 mm interval,
including fixing of Calcium Silicate Board to
ceiling section and perimeter channels with the
help of dry wall screws of size 3.5 x25 mm at
230 mm c/c, including jointing & finishing to a
flush finish of tapered and square edges of the
board with recommended jointing compounds,
jointing tapes, finishing with jointing compounds
in three layers covering up to 150 mm on both
sides of joints and two coats of primer suitable
for boards, all as per manufacture's
specification and also including the cost of
making opening for light fittings, grills, diffusers,
cut outs made with frame of perimeter channels
suitably fixed, all complete as per drawings,
specification and direction of the Engineer in
charge but excluding the cost of painting with:
12.59.1 8 mm thick Calcium Silicate Board made with Sqm 375 1572.3 589612.5
Calcareous & Siliceous materials reinforced with
cellulose fiber manufactured through
autoclaving process.
13.0 FINISHING
13.1S CEMENT PLASTER (IN FINE SAND)
13.1 12 mm cement plaster of mix :
13.20S PEBBLE DASH PLASTER
13.26 Providing and applying plaster of paris putty of Sqm 1500 262.7 394050
31 2 mm thickness over plastered surface to
prepare the surface even and smooth complete.
13.44S EXTERIOR FINISHING
Finishing with Deluxe Multi surface paint system
13.48 for interiors and exteriors using Primer as per
manufacturers specifications :
13.48.2 Painting wood work with Deluxe Multi Surface Sqm 225 176.25 39656.25
Paint of required shade. Two or more coat
32 applied @ 0.90 ltr/10 sqm over an under coat of
primer applied @0.75 ltr/10 sqm of approved
brand and manufacture
BHUSAWAL DIVN-ENGINEERING/CENTRAL RLY
13.48.3 Painting Steel work with Deluxe Multi Surface Sqm 370 170.7 63159
Paint to give an even shade. Two or more coat
33 applied @ 0.90 ltr/10 sqm over an under coat of
primer applied @ 0.80 ltr/10 sqm of approved
brand and manufacture
Wall painting with acrylic emulsion paint, having
VOC (Volatile Organic Compound ) content less
than 50 grams/ litre, of approved brand and
manufacture, including applying additional
coats wherever required, to achieve even shade
Painting with aluminium paint of approved
brand and manufacture to give an even shade:
Finishing walls with Premium Acrylic Smooth
13.112 exterior paint with Silicone additives of required
13.112.1 Old work (Two or more coats applied @ 1.43 ltr/ Sqm 1400 131.3 183820
10 sqm) over existing cement paint surface
14.0 REPAIRS TO BUILDING
14.1S General
Repairs to plaster of thickness 12 mm to 20 mm
in patches of area 2.5 sq.meters and under,
including cutting the patch in proper shape,
14.1 raking out joints and preparing and plastering
the surface of the walls complete, including
disposal of rubbish to the dumping ground, all
complete as per direction of Engineer-in-Charge.
37 14.1.1 With cement mortar 1:4 (1 cement : 4 fine sand) Sqm 35 547.4 19159
Renewing glass panes, with putty and nails
14.5 wherever necessary including racking out the
14.5.1 Float glass panes of nominal thickness 4 mm Sqm 10 1090.65 10906.5
(weight not less than 10kg/sqm)
14.75AS ROUTINE MAINTENANCE WORK
14.75A Cleaning of terrace/loft water storage tank Litre 7500 .5 3750
(inside surface area) upto 2000 litre capacity at
all heights with coconut brushes, duster etc.,
removal of silt, rubbish from the tank and
cleaning the tank with fresh water disinfecting
with bleaching powder @0.5gm per litre
capacity of tank including marking the date of
cleaning on the side of tank body with the help
of stencil and paint and disposing of malba all
complete as per direction of Engineer-in-Charge.
(The old date already written on tank should be
removed with paint remover or black paint and
if date is not written with the stencil or old date
is not removed deduction will be made @ Rs.
0.10 per litre) (if during cleaning any GI fittings
or ball cock is damaged that is to be repaired by
contractor at his own cost and nothing extra will
be paid on this account)
14.76 Cleaning and desilting of gully trap chamber, Each 15 108.3 1624.5
including removal of rubbish mixed with earth
etc. and disposal of same, all as per the
direction of Engineer-in-charge.
BHUSAWAL DIVN-ENGINEERING/CENTRAL RLY
14.77 Cleaning of chocked sewer line by diesel Metre 150 340.75 51112.5
running vehicle mounting hydraulic operated
high pressure suction cum jetting sewer
cleaning machine fitted with pump having 4000
litres suction capacity and 6000 litres water
jetting tank capacity including skilled operator,
supervising engineer etc. for cleaning and
partial desilting of manholes and dechocking of
sewer lines. Dechocking and flushing of sewer
line from one manhole to another by high
pressure jetting system of 2200 PSI for sewer
line from 150mm dia upto 300mm
Providing and laying APP (Atactic Polypropylene
Polymer) modified prefabricated five layer, 3
mm thick water proofing membrane, black
finished reinforced with glass fibre matt
consisting of a coat of bitumen primer for
bitumen membrane @ 0.40 litre/sqm by the
same membrane manufactured of density at 25
degreeC, 0.87 - 0.89 kg/litre and viscosity 70 -
160 cps. Over the primer coat the layer of
membrane shall be laid using butane torch and
sealing all joints etc., and preparing the surface
14.90 complete. The vital physical and chemical
parameters of the membrane shall be as under :
Joint strength in longitudinal and transverse
direction at 23 degreeC as 350/300 N/5 cm.
Tear strength in longitudinal and transverse
direction as 60/80N. Softening point of
membrane not less than 150 degreeC. Cold
flexibility shall be upto -2 degreeC when tested
in accordance with ASTM, D - 5147. The laying
of membrane shall be got done through the
authorised applicator of the manufacturer of
15.0 DISMANTLING AND DEMOLISHING
15.1S General
Demolishing cement concrete manually/ by
mechanical means including disposal of material
within 50 metres lead as per direction of
Engineer - in - charge.
15.2.1 Nominal concrete 1:3:6 or richer mix (including cum 165 2434.25 401651.25
equivalent design mix)
15.3 Demolishing R.C.C. work manually/ by cum 65 3551.25 230831.25
mechanical means including stacking of steel
44 bars and disposal of unserviceable material
within 50 metres lead as per direction of
Engineer - in- charge.
Demolishing brick work manually/ by
mechanical means including stacking of
15.7 serviceable material and disposal of
unserviceable material within 50 metres lead as
per direction of Engineer-in-charge.
23.0 RAIN WATER HARVESTING & TUBEWELLS
23.1S General
Boring/drilling bore well of required dia for
casing/ strainer pipe, by suitable method
prescribed in IS: 2800 (part I), including
collecting samples from different strata,
preparing and submitting strata chart/ bore log,
23.2 including hire & running charges of all
equipments, tools, plants & machineries
required for the job, all complete as per
direction of Engineer -in-charge, beyond 90
metre & upto 150 metre depth below ground
BHUSAWAL DIVN-ENGINEERING/CENTRAL RLY
23.2.2 Rocky strata including Boulders
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
drmwbsl212026t2.pdf
ATTACHMENT
GCCACS11.pdf
ATTACHMENT
AnnexureVIB.pdf
ATTACHMENT
AnnexureVIAFormatofEMDandPBG.pdf
ATTACHMENT
PCEcircular.pdf
ATTACHMENT
BeneficiaryName.pdf
ATTACHMENT
GCC-2022-uptoACS10_1.pdf
ATTACHMENT
Download all tender documents and submit your bid