Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹32.2 LAccepted-AOC 1 OPP NAGAR NIGAM KATNI MAIN ROAD KATNI MADHYA PRADESH 483501 | KATNI | MADHYA PRADESH | 483501 | 1 | Accepted-AOC Lowest quoted | |
| 2 | 2₹33.4 L+₹94,420 (2.91%)Rejected-AOC | 2 | Rejected-AOC 2nd lowest |
Tender Value
Refer Docs
EMD Value
₹76,000
Closing Date
20 May 2021, 6:00 pmClosed
GE AF TUGHLAKABAD
GE AF TUGHLAKABAD SANGAM VIHAR PO NEW DELHI 110080
SPECIAL REPAIR TO STN FIRE SECTION AND OTES HALL WITH ALLIED WORKS AT AF STN TUGHLAKABAD UNDER GE(AF) TUGHLAKABAD
2021_MES_439261_1
GE/TKD/TOKEN-01/2021-22
Open Tender
Civil Works - Others
Item Rate
180 days
GE AF TUGHLAKABAD
MES contractor enlisted as Class D or above category aibi having deposited Standing Security of Rs. 100000 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
8 documents required · 8 mandatory
₹500
GE AF TUGHLAKABAD
₹76,000
Yes
29 Jul 2021
29 Apr 2021
22 May 2021
5 May 2021
20 May 2021
5 May 2021
Amount
Taking down chowkhats with shutter of any description exc 1.00 Sqm and n.exc 2.00 Sqm each with all fittings complete all as specified and directed by Engr-in-Charge.
'-ditto- all as per item No 1 above but area exc. 1.5 Sq.m but not exc. 4 Sq.m each.
S&F Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete profile size 60x105 mm, using 1.25m thick MS sheet complete all as specified and directed by Engr-in-Charge.
S&F Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete profile size 60x125 mm, using 1.25m thick MS sheet complete all as specified and directed by Engr-in-Charge.
S&F 35 mm thick flush shutters, solid core constructed with block board core and plywood face panels commercial type on both side complete all as specified and directed by Engr-in-Charge.
S&F 2nd class hard wood 35 mm thick glazed skeleton shutters open rebated and prepared to receive gauge etc (without sash bars) edges of framing plain chamfered or rounded fitted with cut and mitered beads for securing glass etc and fitted to chowkats complete all as specified and directed by Engr-in-Charge.
S&F 300 mm size mild steel ordinary rat rail rod pattern springs including roller and roller plate complete all as specified and directed by Engr-in-Charge.
S&F 300 mm long mild steel sliding bolt plate type stove enamelled black with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts four on bolt plate and two on staple plate and fixed complete all as specified and directed by Engr-in-Charge.
S&F 200 mm long mild steel barrel tower bolts, ISI market stove enamelled block with bright bolt and fixed complete all as specified and directed.
S&F 150mm long oval type mild steel pressed handles, ISI marked stove enamelled black complete all as 150mm size specified and as directed.
S&F steel windows with side hung shutters including projecting type hinges with steel handle & steel peg stay, complete with glazing bars, dovetailed or welded including taking down the old window complete all as specified and directed by Engr-in-Charge.
-do- all as per item No. 11 above but without glazed bars
S&F MS Framed work such as grills or grating etc with ends of bars welded of any size and any design all as directed of Fe 290 Grade E-165 complete all as specified and directed by Engr-in-Charge.
S&F mild steel flat iron hold fast of any size and similar articles confirming Fe 290 Grade E-165 complete all as specified and directed by Engr-in-Charge.
M&L for PCC 1:2:4, type B1 using 120mm graded stone aggregate as in lintels blocks, copings, etc including necessary form work complete all as specified and directed by Engr-in-Charge.
M&L for cutting holes in brick walls built in cement mortar exc. Half brick but not exc. One brick and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B1 as required complete all as specified and directed by Engr-in-Charge.
M&L for preparing new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete all as specified and directed by Engr-in-Charge.
S&F 3mm thick sheet glass ordinary quality fixing with putty in square not exceeding 0.5 Sqm in each pane complete all as specified and directed by Engr-in-Charge.
S&F GI steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staple complete all as specified and directed by Engr-in-Charge.
M&L for preparing wood or wood based surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engr-in-Charge.
M&L for PCC 1:3:6, type C-2 by using 40mm graded aggregate 75mm thick as in plinth protection complete all as specified and directed by Engr-in-Charge.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr-in-Charge.
M&L for 15 mm thick Screed bed or bedding layer in CM (1:4) set and jointed in neat cement slurry and pointed with white or coloured cement to match complete all as specified and directed by Engr-in-Charge.
S&F non skid ceramic coloured tiles of 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm in floors complete all as specified and directed by Engr-in-Charge.
S&F non skid ceramic coloured tiles of 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm on vertical surfaces such as skirting including 10 mm thick rendering in cement mortar 1:4 and taking down cement plaster etc complete all as specified and directed by Engr-in-Charge.
M&L for 75mm thick PCC 1:4:8 type D-2 as in sub base, Floors, Paving finished even and fair complete all as specified and directed by Engr-in-Charge.
M&L for coloured machine pressed precast concrete interlocking paver blocks of rubber moulded any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and pigments complete all as specified and directed by Engr-in-Charge.
Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engr-in-Charge.
M&L for Vitrified ceramic tiles 10 mm thick Dark shed Double charged (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm but not exceeding 0.42 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in cement mortar 1:3 over 15 mm thick cement concrete 1:2:4, type B-1 by 20 mm graded aggregate) complete all as specified and directed by Engr-in-Charge.
M&L for Vitrified ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm but not exceeding 0.42 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in cement mortar 1:3 on dado /skirting type B-1 complete all as specified and directed by Engr-in-Charge.
Taking down Cement plaster including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed by Engr-in-Charge.
M&L for Rendering 15mm thick in patches in cement mortar 1:6 on other than fare face of brick work or concrete surfaces and finishing the surface even & smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L for Rendering 15mm thick in patches in cement mortar in 1:4 on fare face of brick work or concrete surfaces even and smooth without using extra cement & with using integral water proofing compound complete all as specified and directed by Engr-in-Charge.
M&L for rendering 5mm thick in patches in cement mortar in 1:3 on ceiling complete all as specified and directed by Engr-in-Charge.
M&L for applying 2 coats of oil bound distemper on new surface of walls over 3mm thick wall care putty complete all as specified and directed by Engr-in-Charge.
M&L for preparation of undecorated surfaces of walls and applying two coats of Cement Base Paint of approved tint complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new undecorated surfaces and apply three coat of white wash on ceiling complete all as specified and directed by Engr-in-Charge.
M&L for complete removal of existing surface and applying 3mm thick wall care putty over two coats of oil bound distemper on wall complete all as specified and directed by Engr-in-Charge.
M&L for complete removal of existing surface and applying two coats of Cement Base Paint of approved tint complete all as specified and directed by Engr-in-Charge.
M&L for gunniting to RCC works in column beams, slabs, chajja, facia, landing, balconies etc by removing/ dismantling of RCC (loose concrete) and cutting of steel bar including plaster cleaning of surfaces with wire brushes and applying epoxy, paint anti corrosive coating of minimum 40-50 microns thick with sikatop Armatec 108 or Colusal VL of MC Bauchemie to rusted steel reinforcement after removing cleaning all rust and supply and fixing welded steel wire mesh 75mm x75mm with 4mm dia steel wire as facies/drops and similar works etc and expoxy based or other equivalent suitable bonding against treatment to be carried out on old concrete surface with Sikadur 32 of Sikka. Nito bond EP of fosroc or equivalent (as per manufacturers instruction) to bond old and new concrete mixing @ 2% by weight of cement polycrete and providing gunniting with a minimum pressure of 2 to 2.5 Kg sqcm and applying 25mm thick gunniting in cement mortar (1:2) (one part of cement and two part of ghaghar sand) using ordinary port land cement of 43 grade over wherever required, complete all as specified and directed by Engineer-in-Charge. Note:-(i)After placing the additional reinforcement all concrete surface shall be thoroughly scrubbing with. (ii)Additional reinforced TMT bars where incorporated in work and including 20mm thick cement plaster in 1:4. (iii) Work to be carried out as in patches as directed by Engr-in-charge. (iv) Rate for steel scaffolding as directed to be included in quoted rate. (v) All demolished material removed from MOD land completely.
Demolition of reinforced cement concrete of any description and in any position not otherwise provided for including removing the same complete all as specified and directed by Engr-in-Charge.
M&L for providing pre-cast cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate as in 40mm thick jallies, louvers etc of design & pattern as directed with plain faces, including all necessary form work etc and reinforced with and including 4mm dia MS wire @ 100mm c/c both and set in cement mortar 1:4 complete all as specified and directed by Engr-in-Charge.
S&F anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engr-in-Charge.
Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) incl aluminium anodised colour powder coated grill make deco grill DG-104 fixed complete all as specified and directed by E.I.C .
Anodised aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc including Aluminium anodised colur powder coated grill make deco grill DG-104 fixed with for 'H' section etc complete all as specified
M&L for 12mm prelaminated particle board exterior board grade prelaminate both side with decorative choice lamination fixed with screws to frame complete all as specified and directed by Engr-in-Charge.
S&F Sheet Glass 5.5 ordinary quality and glazing with oil putty in squares exc 50 sqm in each pane extra over sheet glass, ordinary quality, if sheet glass is round or obscured or frosted, on one side complete all as specified and directed by Engr-in-Charge.
Dismantling of ceiling boards (fibre, pulp, insulation, etc.) or solution boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed by Engr-in-Charge.
S&F anodised aluminium snap grid size of grid 605 X 605mm frame work for false ceiling all as specified and directed.
S&F 6mm thick non asbestos fibre cement buildings boards fixed or laid/inserted to timber/GI/aluminium frame work in ceiling with screws complete all as specified and directed by Engr-in-Charge.
M&L for Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified and directed by Engr-in-Charge.
Roughening the surfaces of old concrete roof surfaces by picking, sweeping clean and washing down with water to remove dust etc including removal of old treatment of any description and removing the debris to a distance of n.exc 50 cm away from plinth protection complete all as specified and directed by Engr-in-Charge.
M&L for 10mm thick rendering in cement mortar 1:4 using water proofing compound at the rate of 3% weight of cement over concrete surfaces complete all as specified and directed by Engr-in-Charge.
M&L for priming the plastered roof surfaces with bituminous primer @ 0.30 Kg per sqm and applying APP based polymeric membrane minimum weighing 3 Kg per Sqm and minimum 3mm thick reinforced with polyester non wove fabric (Wt not less than 150 gms/per Sqm) and on primed surface by forced application complete all as specified and directed by Engr-in-Charge.
Supply only water proofing compound complete all as specified and directed by Engr-in-Charge.
M&L for 40 mm thick PCC 1:2:4, type B1 by using 20 mm graded stone aggregate as in roof floors, where required over slabs including necessary form work and finishing the exposed surfaces fair even without using extra cement complete all as specified and directed by Engr-in-Charge.
S&F in repair Rotational molded polythene water storage tanks with closed top fixed in portion 1000 ltr capacity including fittings complete all as specified and directed by Engr-in-Charge.
S&F Ball valve high pressure of PTMT 20mm dia with epoxy coated Aluminium rod & high dnsity plastic ball screwed for iron pipe and fixed complete all as specified and directed by Engr-in-Charge.
M&L for Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed by Engr-in-Charge.
M&L for voids in masonry using chemical emulsion one litre per hole, at 300mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 ment : 2 coarse sand) to match the existing floors complete all as specified and directed by Engr-in-Charge.
M&L for Providing and injecting chemical emulsion for post construction antitermite treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per Sq.m of the vertical surface of the substructure to a depth of 300 mm including excavating channel along the wall and rodding etc. complete all as specified and directed by Engr-in-Charge.
M&L for at points of contact of wood work by chemical emulsion (in oil or Kerosene based solution) @ 0.50 litre/hole by drilling 6mm dia. Hole at a down ward angle of 45 degree at 150 mm centre to centre and sealing the same complete all as specified and directed by Engr-in-Charge.
S&F kota stone slab 20-25 mm thick as in floor etc over and including 15mm screed bed in cement mortar 1:6 & jointed with grey cement slurry over 25mm thick screed bed B-0 (12.5mm graded aggregate) mixed with pigment to match the shade of slab including rubbing & polishing to achieve mirror finish an roughening the surfaces complete all as specified and directed by Engr-in-Charge.
S&F kota stone slab 20-25 mm thick as in landing/risers/ treads/skirting/dado etc over and including 15mm screed bed in cement mortar 1:6 & jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing & polishing to achieve mirror finish an roughening the surfaces complete all as specified and directed by Engr-in-Charge.
Taking down old unserviceable XLPE insulated, armoured, heavy duty electric cable with alluminium conductor, 1100 volt grade cross sectional area 50 Sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
M&L for XLPE insulated, armoured, heavy duty electric cable with alluminium conductor, 1100 volt grade cross sectional area 50 Sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Excavation in trenches soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation etc or for laying of under ground cable/shaft well, cesspits, manholes, fire hole etc not exceeding 10 Sqmm on plan and not exceeding 1.5mtr in depth and getting out complete all as specified and directed by Engr-in-Charge.
Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engr-in-Charge.
Removing excavated material not exceeding 50mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge.
M&L for sand cushion with natural local river sand for cable protection complete all as specified and directed by Engr-in-Charge.
Supply and laying well burnt sub class ‘B’ bricks, locally available in trenches for protection of underground cable complete all as specified and directed by Engr-in-Charge.
M&L in replacement of GI tubing 50 mm dia light grade with all fittings laid in trenches/making GI bracket of security light/ provn for ceiling fan point including bending of suitable size/ support of underground cable as required at site as directed by Engr-in-Charge.
Taking down carefully aluminum point wiring (light/fan/ socket power) including fixture and fitting such as switches, ceiling roses, pendants, regulators, socket, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition separately) and making good the disturbed surfaces of walls/ floor with using one coat of putty and two coats distemper on disturbed surface complete all as specified and directed by Engr-in-charge.
Taking down carefully the existing switches/DB's alongwith board including removing the same from site and making good the disturbed surface of walls, floors etc. with using one coat of putty and two coats distemper on disturbed surface complete all as specified and directed by Engr-in-Charge.
Taking down existing sub main wiring of any type and description including removal of teak wood batten/pipe and making good the disturbed surface of walls, floors with using one coat of putty and two coats distemper on disturbed surface complete all as specified and directed by Engr-in-charge.
M&L for concealed point wiring complete with 1.5 Sqmm (nominal area) PVC insulated, multi stranded, FRLS copper conductor cable unsheathed drawn through and including 20mm dia PVC conduit with all fittings of medium grade ISI Marked duly concealed by cutting chases and making good to match with surroundings including necessary periodicals applying one coat of putty and 2 coats of oil bound distemper along with PVC insulated FRLS copper conductor cable of size 1.5 Sq mm as earth wire, connected to common earth dolly suitable for mounting switches including metal flush boxes complete all as specified and as directed by Engr-in-charge for the following points:- Note: The work includes cutting of chases and making good disturbed surfaces and quoted rate shall deemed to be included the same aspect.
One light/fan/bell point controlled by one piano type switch 5 Amps single pole one way.
One socket outlet 5/3 pin 5 Amps controlled by one switch on the same board.
One socket outlet 5/3 pin 5 Amps controlled by one switch on independent board.
-Ditto- All as per sl item No 4.00 above but for 3 pin socket outlet point 15 Amp on indipendent board with cable of size 2.5 Sq mm multistranded, PVC insulated sheathed copper conductor cable and 2.5 Sq mm earth continuity conductor in 20 mm dia PVC conduit medium grade.
M&L for replacement of modular white cover plate with frame 3 module complete all as specified and directed by Engr-in-charge.
M&L for replacement of modular white cover plate with frame 8 module complete all as specified and directed by Engr-in-charge.
M&L for replacement of modular metal flush box for 3 module complete all as specified and directed by Engr-in-charge.
M&L for replacement of modular metal flush box for 8 module complete all as specified and directed by Engr-in-charge.
M&L for replacement of Modular switch piano type 10 Amps one way single pole 240 volts AC complete all as specified and directed by Engr-in-charge.
M&L for replacement of Modular switch piano type 20 Amps complete all as specified and directed by Engr-in-charge.
M&L for replacement of Modular socket outlet 10 Amps 5 pin 240 Volts multi socket for cell phone pin or 2 pin + 3 pin complete all as specified and directed by Engr-in-charge.
M&L for replacement of modular socket outlet 20 Amps 6 pin 240 Volts twin socket heavy duty complete all as specified and directed by Engr-in-charge.
M&L for replacement of modular bell push 6 Amps large piano type single pole one way 240 volts AC complete all as specified and directed by Engr-in-charge.
M&L for replacement of bell ding dong/bell musical single phase 230 volts complete all as specified and directed by Engr-in-charge.
M&L for replacement of Modular ceiling fan regulator suitable electronic rotary step type 100 Watt 2 module complete all as specified and directed by Engr-in-charge.
S&F in replacement of 4 feet, surface mounting, white, LED tube light fitting 1x22 W decorative and IP-65 luminaire as per manufacturer's description suitable for wet location with brightness LED with all accessories internally wired and conncted with twin core twisted flxible wire copper conductor complete all as specified and directed by Engr-in-Charge for any one of following make:- Make: Cat No HLPT81420(WW) of HPL/Cat No LHEXBTP7IN1S022 of Havells/Cat No BLTRU 20W WH VIVA of Bajaj
S&F in replacement sheet metal enclosure for MCB DB single pole and neutral 8 way with 200 Amps rated bus bar 240 volts double door type complete all as specified and directed by Engr-in-charge.
S&F in replacement MCB SP upto 40 Amps 240 volts complete all as specified and directed by Engr-in-charge.
S&F in replacement MCB SPN capacity 40 to 63 Amps 240 volts breaking capacity 10 kA, 'C' series complete all as specified and directed by Engr-in-charge.
M&L for replacement of invertor wiring with one single core HRFR PVC insulated, unsheathed copper conductor 1100 Volt grade, multistrandard of size 1.5 Sq mm complete all as specified and directed by Engr-in-charge.
M&L for sub main wiring with two single core PVC insulated of size 6 Sqmm unsheathed copper conductor 1100 volt grade multistandard including drawn through, non metallic rigid PVC conduit, conduit accessories of 25 mm external dia medium grade, 6 Sqmm copper wire for earth continuity wire and connected of common earth dolly complete all as specified and directed by Engr-in-charge. Note:- One run of conduit, three runs of 6 Sq mm copper conductor is measured as one unit RM.
M&L for Earthing complete with galvanized earth plate electrode 600mmx 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.6 mtr below ground level connected to galvanised earth lead wire of 4 mm dia by means of nuts, bolts, washes of galvanized iron or steel all as shown in electrical plate No 3 and testing on completion including adequate charcoal dust comman salt necessary excavation & earth work PCC 1:3:6 type, C-1 pit with precast RCC Cover slab 40 mm thick in PCC1:2:4, type B-0 reinforced with 6 mm dia MS bars @ 100 mm c/c both ways with funnel wire mesh and 20 mm dia GI pipe medium grade as watering pipe, common salt, charcoal and connected to earthing list point complete all as specified and directed by Engr-in-charge. Note: GI pipe and wire beond 7.5 mtr will measured and paid respectively.
M&L for lamp holder insulated body with back plate for batten fittings complete all as specified and directed by Engr-in-charge.
M&L for replacement of sheet metal enclosure MCCB distribution board, with hinged cover IP 43 protection metal door epoxy powder coated/made of insulating material like, polystyrene, double door 4 way TPN with 200 A rated bus bar for (vertical operation) incorporation of MCCB 4 pole 125 Amps 25 kA and 12 Nos outgoing MCB SP complete all as specified and directed by Engr-in-charge. Note: MCCB's, MCB's, Isolators shall be measured and paid separately under relevant items. Make: Cat Part No DHDMTHODDW12 of Havells/Cat Part No 811436 of Indo Asian
M&L for submain wiring for AC concealed/surface wiring with two single core PVC insulated unsheathed FR copper conductor 1100 volt grade multistandard of size 4 sqmm and incl drawn through and including non metallic rigid pvc conduit and couduit accessories of 20 mm external dia and conduit accessories of ISI marks medium grade including 4 sqmm copper wire for earth continuity wire and connected of common earth dolly complete all as specified and directed by Engr-in-charge. Note:- One run of conduit, three runs of 4 Sq mm copper conductor is measured as one unit RM.
Supply and replacement of metal clad sheet metal plug and socket with 2 pin earth plug including 20 Amps SP MCB, 240 Volt including making all connections complete all as specified and directed by Engr-in-Charge.
S&F in replacement with new heavy duty exhaust fan Turbo Force SP of size 300 mm sweep, 900 RPM, metal body, ISI marked with copper winding suitable for 230 Volts, single phase, 50 Hz, AC with all connected accessories complete all as specified and directed by Engr-in-Charge.
S&F in replacement three phase/PVC/Polycarbonate, isolated body ceiling rose complete all as specified and as directed by Engr-in-charge.
S&F MCCB 4 Pole 415 V, Adjustable type 125 Amps with breaking capacity 25 KA and fixed magnetic setting Ics=75% of Icu complete all as specified and directed by Engr-in-charge.
S&F LED street light fitting of capacity 70 Watt new generation energy saving and environment friendly long life made of pressure die cast aluminium housing with high efficeing LED as lighting source with tougnened glass having IP-66 protection and impace resistance of IK-07 including GI bend, clamp, nut, bolt and connecting cable with drivers and all accessories and making necessary connections, commissioning and testing complete all as specified and directed by Engr-in-charge. Make:- Cat part no. ENDURACITYLINERNEOSL70W LED757PASYBOTG of Havells/ Cat No LSTP-72CDL of Bajaj/ Cat No BRTFG 72W LED I of Bajaj
Cutting chases, pinning in making good to facing where requires and pointing in cement mortar 1:3 to ends or edges of landings, steps cels, sunshades, shelves, lintels etc and for concealed water tubing or concealed conduit wiring and making good the disturbed surfaces as per existing surface complete all as specified and directed by Engr-in-charge. Note: Cutting of chases not exceeding 10 cm girth.
S&F non metalic PVC conduit 32 mm dia exclusive of boxes (Junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers lock nuts, saddles pipe, hooks including connecting accessories complete all as specified and directed by Engr-in-charge.
Notes: The amount of Rs 30,428/- against schedule of credit given on Tender Serial Page No 42 shall be deducted from the total amount quoted by the contractor against BOQ while deriving the contract sum for acceptance.
M/S S.K.Electricals
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .