Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹84.2 LAccepted-AOC HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | ₹84.2 L Quoted ₹86.3 L | L1 | Accepted-AOC Awarded being lowest as per NIT |
| 2 | L2₹95.7 LRejected-Finance | ₹95.7 L | L2 | Rejected-Finance Rejected being L2 bidder |
| 3 | L3₹99.5 LRejected-Finance | ₹99.5 L | L3 | Rejected-Finance Rejected being L3 bidder |
| 4 | L4₹1.1 CrRejected-Finance | ₹1.1 Cr | L4 | Rejected-Finance Rejected being L4 bidder |
| Sl No | Description | Qty | Unit | M/S Sky Engineers L3 | UNITED ENGINEERING CORPORATION L1 | M/S MARSHAL TRADERS L4 | M/S Noor Mohammad Shalla L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Disconnecting LT cable/ busbar and earthing connections of LT Servo voltage stabilizer of capacity 400 KVA, 3 phase from floor with the help of Crane to carry out overhauling of servo voltage stabilizer comprising of the following:-
(i) Draining out oil from chamber.
(ii) Opening top cover, disconnecting winding connection from bushing and taking out carefully core assembly complete with winding.
(iii) Checking compactness of core & tightening the same where required.
(iv) Chemical washing of winding to remove dirt, dust & carbon particles.
(v) Cleaning of oil tank to remove oil sludge followed by painting to inner surface of tank with zinc chromate base paint.
(vi) Refixing of core & winding assembly and making connection with HT/LT bushing.
(vii) renewal of worn out gaskets & nuts/ bolts.
(viii) Refilling of oil duly filtered/ dehydrated/ fresh oil.
Notes: (i) Overhauling of servo voltage stabilizer shall be done on existing installation place and must be completed on same day.
(ii) Dehydrated fresh oil shall be measured and paid separately. | 6 | Each Job | 5,000 ₹30,000 | 6,000 ₹36,000 | 4,500 ₹27,000 | 7,000 ₹42,000 |
| 2.00 | All as per ser Item No 1.00 here-in-before but LT servo voltage stabilizer of capacity 200 to 300 KVA. | 4 | Each Job | 6,000 ₹24,000 | 5,000 ₹20,000 | 4,000 ₹16,000 | 6,000 ₹24,000 |
| 3.00 | All as per ser Item No 1.00 here-in-before but capacity 100 to 160 KVA complete all as specified and directed. | 6 | Each Job | 6,500 ₹39,000 | 4,500 ₹27,000 | 3,500 ₹21,000 | 5,000 ₹30,000 |
| 4.00 | All as per ser Item No 1.00 here-in-before but capacity 50 to 75 KVA complete all as specified and directed. | 12 | Each Job | 4,500 ₹54,000 | 4,000 ₹48,000 | 3,000 ₹36,000 | 3,000 ₹36,000 |
| 5.00 | All as per ser Item No 1.00 here-in-before but capacity 20 to 30 KVA complete all as specified and directed. | 8 | Each Job | 3,000 ₹24,000 | 3,000 ₹24,000 | 3,000 ₹24,000 | 1,500 ₹12,000 |
| 6.00 | Supply, installation and testing of MC TRMS PCB suitable for voltage stabilizer of capacity 25 to 400 KVA in renewal complete all as specified and directed. | 18 | Each | 1,800 ₹32,400 | 1,000 ₹18,000 | 2,000 ₹36,000 | 200 ₹3,600 |
| 7.00 | Supply, installation and testing of contactor 530 Amps, suitable for 400 KVA LT servo voltage stabilizer 3 phase in renewal complete all as specified and directed. | 5 | Each | 7,500 ₹37,500 | 8,000 ₹40,000 | 67,000 ₹3.4 L | 8,000 ₹40,000 |
| 8.00 | All as per ser Item No 7.00 here-in-before but 430 Amps, suitable for 200 to 300 KVA LT servo voltage stabilizer. | 4 | Each | 5,000 ₹20,000 | 8,000 ₹32,000 | 45,000 ₹1.8 L | 5,500 ₹22,000 |
| 9.00 | All as per ser Item No 7.00 here-in-before but 230 Amps, suitable for100 to 160 KVA LT servo voltage stabilizer. | 6 | Each | 5,000 ₹30,000 | 6,000 ₹36,000 | 34,000 ₹2.0 L | 5,500 ₹33,000 |
| 10.00 | All as per ser Item No 7.00 here-in-before but 180 Amps, suitable for 50 to 75 KVA LT servo voltage stabilizer complete all as specified and directed | 12 | Each | 3,000 ₹36,000 | 5,000 ₹60,000 | 16,000 ₹1.9 L | 5,500 ₹66,000 |
Updated dates
Tender Value
₹1.2 Cr
EMD Value
₹1.9 L
Closing Date
19 Nov 2025, 6:00 pmClosed
CWE, HQ 133 WORKS ENGRS
HQ 133 WORKS ENGRS, C/O 56 APO, PIN- 914133
CWEK/TOKEN-94/864 EWS/2025-26 COMPREHENSIVE MAINTENANCE OF LT VOLTAGE STABILIZER INCLUDING CONNECTED ITEMS, REPAIR / MAINTENANCE OF LT PANEL, LT CABLE, FLOOD LIGHTS AND STREET LIGHTS IN THE AOR OF AGE E/M UNDER GE 864 EWS
2025_MES_735341_1
CWEK/TOKEN-94/864 EWS/2025-26
Open Tender
Electrical and Maintenance Works
270 days
GE 864 EWS
Class B and above and Category b (i)
7 documents required · 7 mandatory
₹1,000
GE 864 EWS
₹1.9 L
HQ 133 WORKS ENGRS
14 Jan 2026
16 Oct 2025
26 Nov 2025
16 Oct 2025
19 Nov 2025
6 Nov 2025
16 Oct 2025 - 21 Oct 2025
23 Oct 2025
Amount
Disconnecting LT cable/ busbar and earthing connections of LT Servo voltage stabilizer of capacity 400 KVA, 3 phase from floor with the help of Crane to carry out overhauling of servo voltage stabilizer comprising of the following:- (i) Draining out oil from chamber. (ii) Opening top cover, disconnecting winding connection from bushing and taking out carefully core assembly complete with winding. (iii) Checking compactness of core & tightening the same where required. (iv) Chemical washing of winding to remove dirt, dust & carbon particles. (v) Cleaning of oil tank to remove oil sludge followed by painting to inner surface of tank with zinc chromate base paint. (vi) Refixing of core & winding assembly and making connection with HT/LT bushing. (vii) renewal of worn out gaskets & nuts/ bolts. (viii) Refilling of oil duly filtered/ dehydrated/ fresh oil. Notes: (i) Overhauling of servo voltage stabilizer shall be done on existing installation place and must be completed on same day. (ii) Dehydrated fresh oil shall be measured and paid separately.
All as per ser Item No 1.00 here-in-before but LT servo voltage stabilizer of capacity 200 to 300 KVA.
All as per ser Item No 1.00 here-in-before but capacity 100 to 160 KVA complete all as specified and directed.
All as per ser Item No 1.00 here-in-before but capacity 50 to 75 KVA complete all as specified and directed.
All as per ser Item No 1.00 here-in-before but capacity 20 to 30 KVA complete all as specified and directed.
Supply, installation and testing of MC TRMS PCB suitable for voltage stabilizer of capacity 25 to 400 KVA in renewal complete all as specified and directed.
Supply, installation and testing of contactor 530 Amps, suitable for 400 KVA LT servo voltage stabilizer 3 phase in renewal complete all as specified and directed.
All as per ser Item No 7.00 here-in-before but 430 Amps, suitable for 200 to 300 KVA LT servo voltage stabilizer.
All as per ser Item No 7.00 here-in-before but 230 Amps, suitable for100 to 160 KVA LT servo voltage stabilizer.
All as per ser Item No 7.00 here-in-before but 180 Amps, suitable for 50 to 75 KVA LT servo voltage stabilizer complete all as specified and directed
All as per Item No 7.00 here-in-before but 40 Amps, suitable for 20 to 30 KVA LT servo voltage stabilizer.
Supply, installation and testing of upto 2 Kg motor sync suitable for 20 to 75 KVA LT servo voltage stabilizer in renewal complete all as specified and directed.
Supply, installation and testing of 3 Kg motor sync suitable for 100 to 160 KVA servo voltage stabilizer in renewal complete all as specified and directed.
Supply, installation and testing of 10 Kg motor sync suitable for upto 200 to 400 KVA LT servo voltage stabilizer in renewal complete all as specified and directed.
Supply, installation and testing of RC suitable for 20 to 400 KVA LT servo voltage stabilizer in renewal complete all as specified and directed.
Supply, installation and testing of carbon bush suitable for 20 to 400 KVA LT servo voltage stabilizer in renewal complete all as specified and directed.
Supply, installation and testing of dimmer coil as per existing size suitable for 20 to 30 KVA voltage stabilizer in renewal complete all as specified and directed.
Supply, installation and testing of dimmer coil as per existing size suitable for 50 to 75 KVA voltage stabilizer in renewal complete all as specified and directed.
Supply, installation and testing of dimmer coil as per existing size suitable for 100 to 160 KVA voltage stabilizer in renewal complete all as specified and directed.
Supply, installation and testing of dimmer coil as per existing size suitable for 200 to 400 KVA voltage stabilizer in renewal complete all as specified and directed.
Supply, installation and testing of closer sheet suitable for 20 to 400 KVA voltage stabilizer in renewal as per existing size complete all as specified and directed.
Supply, installation and testing of 20kg motor sync suitable for 400 KVA voltage stabilizer in renewal complete all as specified and directed.
Supply, installation and testing of Carbon roller assembly suitable for 20 to 400 KVA voltage stabilizer in renewal complete all as specified and directed.
Supply, installation and testing of tag & tail assembly as per sample suitable for 20 to 400 KVA voltage stabilizer in renewal complete all as specified and directed.
Supply, installation and testing of PCB relay as per existing sample suitable for 20 to 30 KVA voltage stabilizer in renewal complete all as specified and directed.
Supply, installation and testing of PCB relay suitable for 50 to 75 KVA voltage stabilizer in renewal complete all as specified and directed.
Supply, installation and testing of PCB relay suitable for 100 to160 KVA voltage stabilizer in renewal complete all as specified and directed.
Supply, installation and testing of PCB relay suitable for 200 to 300 KVA voltage stabilizer in renewal complete all as specified and directed.
Supply, installation and testing of PCB relay suitable for 400 KVA voltage stabilizer in renewal complete all as specified and directed.
Supply, installation and testing of flip flop suitable for 20 to 400 KVA voltage stabilizer in renewal as per existing sample complete all as specified and directed
Supply, installation and testing of time delay relay suitable for 20 to 400 KVA voltage stabilizer in renewal as per existing sample complete all as specified and directed.
Supply, installation and testing of limit switch (B4C) suitable for 20 to 400 KVA voltage stabilizer in renewal complete all as specified and directed.
Supply, installation and testing of power contractor suitable for 20 to 400 KVA as per existing in renewal sample complete all as specified and directed.
Supply, installation and testing of auxiliary contractor 4 Nos + 4NC 44W, 230V AC complete suitable for 20 to 160 KVA voltage stabilizer in renewal complete all as specified and directed by Engr-in-Charge.
Supply, installation and testing of auxiliary contractor 4 Nos + 4NC 44W, 230V AC complete suitable for 200 to 400 KVA voltage stabilizer in renewal complete all as specified and directed by Engr-in-Charge.
Supply, installation and testing of auxiliary contractor 6 Nos +2NC 62W, 110V AC complete suitable for 20 to 160 KVA voltage stabilizer in renewal complete all as specified and directed by Engr-in-Charge.
S&F MCCB 4 pole 40 Amps breaking capacity 25 KA, including spreader link & taking down existing old unserviceable MCCB of same capacity complete all as specified and directed.
S&F MCCB 4 pole 160 Amps breaking capacity 25 KA, including spreader link & taking down existing old unserviceable MCCB of same capacity complete all as specified and directed.
S&F MCCB 4 pole 200 Amps breaking capacity 36 KA, including spreader link & taking down existing old unserviceable MCCB of same capacity complete all as specified and directed.
S&F MCCB 4 pole 400 Amps breaking capacity 36 KA, including spreader link & taking down existing old unserviceable MCCB of same capacity complete all as specified and directed.
S&F MCCB 4 pole 630 Amps breaking capacity 50 KA, including spreader link & taking down existing old unserviceable MCCB of same capacity complete all as specified and directed.
M&L for topping up of transformer oil or for renewal in voltage stabilizer complete all as specified and directed. Note: Transformer oil shall be in company sealed barrel having BDV not less than 65KV and topping up transformer oil or renewal shall be done on existing installation place on same day.
Supply, laying and testing in renewal of cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with stranded aluminium conductor, 1100 Volts grade, of size single Core 240 Sqmm in renewal complete all as specified and directed.
Supplying, laying, fixing, jointing and testing in renewal of LT under ground XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross sectional area 95 Sqmm x 3.5 Core, confirming to IS 7098 with electric connection lugs, laid in trenches/under floor or fixed naked with walls / on poles/ in ducts / in GI pipes etc. including taking down old unserviceable cable complete all as specified and directed.
S&F synthetic rubber insulating mats 3mm thick for voltage up to 11KV of size 2 mtr x 2 mtr x 19 mm for electric purpose as per relevant IS (superseding IS 5424) suitable for electric shock safety complete all as specified and directed.
S&F copper wire using for winding of voltage stabilizer of capacity 50 KVA to 160KVA complete all as specified and directed.
S&F copper wire using for winding of voltage stabilizer of capacity 200KVA to 400KVA complete all as specified and directed.
M&L in renewal for earthing complete with galvanised steel earth plate electrode 60cmX60cm and 6.0mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to GI earth strip of size 32X6mm by means of bolts nuts, check nuts and washers of galvanised iron complete earth pit of PCC M-10 (Normal mix) using 20mm graded stone aggregate, 50mm thick earth pit cover of RCC M-15 (Nominal mix) using 20mm graded stone aggregate with MS TMT reinforcement bar of 8mm dia @ 150mm centre to centre both ways, MS handle 10mm dia made to shape, GI funnel, wire mesh and 20mm bore GI water pipe medium grade and 40mm bore medium grade GI pipe for protection of earth strip from plate to main switch board, common salt, charcoal dust including testing on completion all as shown in electrical plate No 3 and making good the disturbed surface of wall floors etc to match with existing surfaces without claiming extra any cost all as directed by Engr-in-Charge.
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth for laying of cables, pipes etc. and getting out all excavated material in any type of soil complete all as specified and directed.
Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing of excavated surplus soil to a distance not exc 50 m and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed.
M&L of locally available river sand in trenches below and above/around UG cable for protection, in duct including punning around cable complete all as specified and directed. Note - Only punned thickness shall be measured and paid.
Supply and laying unreinforced PCC cable protection cover, class LV, type-1 flat with size 250 x 150 x 40 mm laid flat width wise complete all as specified and directed.
Supplying, laying, fixing, jointing and testing LT under ground XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm x 4 Core, IS 7098 marked, with electric connection lugs, laid in trenches/under floor or fixed naked with walls / on poles/ in ducts / in GI pipes etc. and including taking down complete all as specified and directed. Note - Excavation, earth work, sand cushioning, PCC cover and GI pipe shall be measured and paid separately. Make :- Gloster/Grandly/Polycab/Havells/ Finolex / KEI
All as per ser Item No. 57 here-in-before but 25 sqmm x 4 Core
All as per ser Item No. 57 here-in-before but 50 sqmm x 3.5 Core
All as per ser Item No. 57 here-in-before but 120 sqmm x 3.5 Core
All as per ser Item No. 57 here-in-before but 150 sqmm x 3.5 Core
All as per ser Item No. 57 here-in-before but 185 sqmm x 3.5 Core
All as per ser Item No. 57 here-in-before but 10sqmm x 2Core
All as per ser Item No. 57 here-in-before but 10 sqmm x 4 Core
Supply and laying GI pipe 'light grade' 40 mm bore in trenches, under floors, roads, along poles for protection of cables with all necessary fittings and sealing ends complete all as specified and directed. Make:- Jindal, Prakash Surya, Tata
All as per ser Item No. 65 here-in-before but GI pipe 'light grade' 50 mm bore
All as per ser Item No. 65 here-in-before but GI pipe 'light grade' 80 mm bore
S&F straight through LT cable jointing kit including jointing material and excavation upto 3mtr length and making good to disturbed surfaces to match with existing surfaces after jointing of cable complete of size 95 to 120 sqmm 3.5 core in renewal complete all as specified and directed.
S&F in renewal of unserviceable straight through LT joint including jointing material and excavation upto 3mtr length and make good surface after jointing of cable complete of size 150 to 185 sqmm 3.5 core complete all as specified and directed.
S&F in renewal of MCCB 4 pole 63 Amps breaking capacity 25 KA, including spreader link & taking down existing old unserviceable MCCB of same capacity complete all as specified and directed.
S&F MCCB 4 pole 100 Amps breaking capacity 25 kA, including spreader link & taking down existing old unserviceable MCCB of same capacity complete all as specified and directed.
S&F MCCB 4 pole 250 Amps breaking capacity 36 kA, including spreader link & taking down existing old unserviceable MCCB of same capacity complete all as specified and directed.
S&F MCCB 4 pole 350 Amps breaking capacity 36 kA, including spreader link & taking down existing old unserviceable MCCB of same capacity complete all as specified and directed.
S&F onload change over switch cubical type 4 pole of rating 630 Amps, with rotary handles in renewal complete all as specified and directed.
S&F offload change over switch cubical type 4 pole of rating 400 Amps, with rotary handles in renewal complete all as specified and directed.
S&F offload change over switch cubical type 4 pole of rating 250 Amps, with rotary handles in renewal complete all as specified and directed.
S&F offload change over switch cubical type 4 pole of rating 200 Amps, with rotary handles in renewal complete all as specified and directed.
S&F offload change over switch cubical type 4 pole of rating 125 Amps, with rotary handles in renewal complete all as specified and directed.
Supply only aluminium terminal (lugs) of size 300 sqmm
Supply only aluminium terminal (lugs) of size 240 Sqmm
Supply only aluminium terminal (lugs) of size 185 Sqmm
Supply only aluminium terminal (lugs) of size 150 Sqmm
Supply only aluminium terminal (lugs) of size 120 Sqmm
Supply only aluminium terminal (lugs) of size 95 Sqmm
Supply only aluminium terminal (lugs) of size 50 Sqmm
Supply only aluminium terminal (lugs) of size 25 Sqmm
Supply only aluminium terminal (lugs) of size 16 Sqmm
M&L for providing of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed.
Supply, installation, testing and commissioning in renewal LT panel board suitable for 415 Volts, 3 Phase 4 wire, 50 Hz AC supply system outdoor type floor mounted along with factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15mm thick with ingress protection of IP-54 grade having aluminium bus bar of rating 400 Amps, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The panel shall be front openable and having inner & outer shells. The inner shell dully compartmented for each control gear, including powder coating internally and externally the entire steel surfaces. All the cover shall be provided with suitable locking arrangements. The size of the outer shell should not be less than 1200mm x 1200mm x 450mm, mounted on angle iron stand made out of angle size 50 x 50 x 6mm grouted in PCC foundation in cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate), including accommodating the following control gears and accessories:- (a) MCCB 250 Amps 4 pole 25KA 415 volts,(incoming) – 01No (b) MCCB 125 Amps 4 pole ,16 KA 415 Volts (out going ) -03 Nos (c) MCCB 63 Amps 4 pole ,16 KA 415 Volts (out going ) -01 (e) Aluminium Bus bar of capacity 400 Amps 3phase and neutral -1 set. (f) Digital type voltmeter 0-500 volts. (h) Digital type Ammeter with CT of suitable ratio for reading upto 400 amps load-01 No (j) Indicating LED lamps R,Y& B -01 set
S&F in renewal of LT switch gear 440 Volts, 3 phase, 4 wire, 50 cycles, Air circuit breaker, cubical manual draw out type complete with microprocessor release of capacity rating up to 800 Amps, 50KA. The protection relays should be provided with in built short circuit protection, overload protection, instantaneous protection (IPR), ground fault protection and functional blocking, The ACB should have been designed for an operating voltage upto 690 Volts. The rated insulated voltage (UI) shall be 1000 Volts and the rated impulsive voltage (UMP) should be 12KV including sheet enclosure and mounted arrangement etc complete all as specified and directed.
S&F in renewal of LT switch gear 440 Volts, 3 phase, 4 wire, 50 cycles, Air circuit breaker, cubical manual draw out type complete with microprocessor release of capacity rating up to 630Amp, 50KA. The protection relays should be provided with in built short circuit protection, overload protection, instantaneous protection (IPR), ground fault protection and functional blocking, The ACB should have been designed for an operating voltage upto 690 volts. The rated insulated voltage (UI) should be 1000 volts and the rated impulsive voltage (UMP) should be 12KV including sheet enclosure and mounted arrangement etc complete all as specified and directed. Makes : Havells, Legrand, Schneider
M&L for painting of steel tubular pole upto 09 mtrs length including clamp, bracket and junction box with two coats of aluminium paint after preparation of old painted surface and providing 03 no. alternate strip of 30 cm wide with black and white super quality enamel paint above embedded level and writing pole no. with 02 inch wide letter complete all as specified and directed. Make of paint - Asian / Nerolac / Berger
S&F in renewal aluminum busbar 400 Amps capacity, colour code with neutral including 200 Amps MCCB three phase and natural with enclosure complete all as specified and directed. Make of MCCB - Schneider, L&T, Havells, C&S
Taking down old unserviceable PCC street light pole complete including dismantling of street light and shifting the same street light, to erection not more than one km distance including bracket and nut bolt etc. complete all as specified and directed. Note - Excavation, concrete and copping shall be measured and paid separately.
Excavating in trenches exc 1.5m wide but exc 1.5m and n exc 3.0m deep for foundation of poles strut/stays etc n exc 10 sqm on plan and getting out in any type of soil complete all as specified and directed.
M&L PCC 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L PCC 1:3:6, type C-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L PCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate) as in coping including existing pole including weathering slightly rounded / chamfered angle with and including necessary use and waste of foam work for fair finished surfaces complete all as specified and directed.
S&F steel tubular swaged poles complete with cast iron base plate, final tapper plug, bolts, nuts & screws as specified type 410 SP-31(11 mtr long) complete all as specified including painting of pole with one coat of black bituminous paint (up to planting depth) and above plinth block / concrete collar with two coats of aluminium paint over a coat of red oxide primer including making five alternate strips 30 cm wide with black and yellow paint in two coats, marking MES number with black pain including three core wire minimum 1.5 sqmm from junction box to street light complete all as specified and directed.
S&F in renewal of security light bracket with 40/32/25 mm dia GI Pipe light grade 1.2 mtr long bend to an angle of 120 degrees with two nos. MS flat iron clamp 50 x 6 mm, nuts, bolts and washers, duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F in renewal of PVC junction box IP - 66 DK 1000 G thermoplastic poly carbonate including connector block and 20Amps,SP MCB including two holes for incoming and outgoing cables, providing cable glands double compression as per requirement, providing DIN rail for mounting MCB SP and clamps made out of MS flat iron 25 x 4 mm, MS hexagonal bolts, nuts and washers for arrangements to pole/ surfaces complete all as specified and directed. Make - Hensel / Schneider / GE
Supplying, laying, fixing, jointing and testing LT services cable heavy duty electric cable with copper conductor, 1100 Volts grade, cross sectional area 6 sqmm 4 core, ISI marked, with electric connection lugs, fixed naked with walls / on poles/ on high mast / in GI pipes etc. and including taking down complete all as specified and directed. Make - Gloster / RR cable/ Havells / Finolex
Supply and laying unreinforced PCC Cable protection cover, class LV, type-1 flat with size 250 x 150 x 40 mm laid flat width wise complete all as specified and directed.
Supply, installation, testing and commissioning of LED streetlight fitting with a nominal system 5300 lumen output of lumens, minimum system efficacy of 115 lm/W and total power consumption not exceeding 45 W (including driver). The luminaire shall have a rated system lifetime of 50,000 burning hours at L70B50. The luminaire should have a colour temperature of 5700 - 6500K and CRI>80. The luminaire shall meet IP66/IK07 or IK08 rating with THD<10% and PF > 0.95. The luminaire housing should made of pressure die cast aluminium and the integrated luminaire optics shall have a high efficiency diffuser with more than 85% transmittance. The fitting should have an internal SPD of minimum 4 kV. The driver should have phase to phase protection for 8 hours. The luminaire should have a NABL approved LM79 report. LM80 report from the LED manufacture is a must along with photo biological report. Luminaire and the driver shall be BIS certified separately and shall posses separate "R" numbers. Fitting should include nut bolt and SS screws for suitably fixing on the exiting steel tubular pole complete all as specified and directed.
All as per ser Item No. 107 here-in-before but with nominal system output of 8400 lumens, minimum system efficacy of 110 lm/W and total power consumption not exceeding 70 W (including driver).
All as per ser Item No. 107 here-in-before with nominal system output of 11000 lumens, minimum system efficacy of 120 lm/W and total power consumption not exceeding 90 W (including driver).
All as per ser Item No. 107 here-in-before but with nominal system output of 15000 lumens, minimum system efficacy of 120 lm/W and total power consumption not exceeding 120 W (including driver).
Disconnecting and lowering carefully light fittings from high mast, 12-20 mtr high for maintenance / repairs of light fittings and refixing the light fittings after repairs complete all as specified and directed. Note:- Spare parts shall be measured and paid separately.
Supply, installation, testing and commissioning of LED flood light fitting with a nominal system 16200 lumen output of lumens, minimum system efficacy of 110 lm/W and the total power consumption should not exceed 120 W (including driver). The luminaire shall have a rated system lifetime of 25,000 burning hours at L70B50. The luminaire should have a colour temperature of 5700 - 6500K and CRI>80. The luminaire shall meet IP65/IK07 rating with THD<10% and PF > 0.95. The luminaire housing should made of pressure die cast aluminium and the integrated luminaire optics shall have a high efficiency diffuser with more than 85% transmittance. The fitting should have an internal SPD of minimum 4 kV. The luminaire should have a NABL approved LM79 report. LM80 report from the LED manufacture is a must along with photo biological report. Luminaire and the driver shall be BIS certified separately and shall posses separate "R" numbers. Fitting should include nut bolt and SS screws for suitably fixing on the exiting steel tubular pole complete all as specified and directed.
All as per ser item No. 112 here-in-before but with nominal system output of 21600 lumens, minimum system efficacy of 110 lm/W and total power consumption not exceeding 180 W (including driver).
All as per ser item No. 112 here-in-before but warm with nominal system output of 16200 lumens, minimum system efficacy of 110 lm/W and total power consumption not exceeding 50/70 W (including driver).
Disconnecting and taking down street / security light fitting of any size / capacity / make from the pole / bldg for repair / renewal of unserviceable spare parts etc., testing, cleaning the fittings internally and externally and renewal of unserviceable wiring not more than 0.3 Mtrs with 1.5 sqmm PVC insulate copper wire, checking and repairing of loose connections, renewal of wire connectors, nuts, bolts, screws and fixing the light fitting in original position on wall / pole / sentry post / top of building including necessary electrical connection complete all as specified and directed. Note:- Driver and SPD shall be measured and paid separately.
Supply, fixing, testing and commissioning in renewal SPD for LED street light upto 120W/LED flood light upto 200W or as per existing capacity fitting with suitable surge capacity complete all as specified and directed.
Supply, fixing, testing and commissioning in renewal of Driver for LED street light / flood light fitting with suitable surge capacity complete all as specified and directed.
Supplying, laying, fixing, jointing and testing LT services cable heavy duty electric cable with Aluminium Conductor, 1100 volts grade, cross sectional area 6 sqmm 2 core, ISI marked, with electric connection lugs, fixed naked with walls / on poles/ in GI pipes etc. and including taking down old unserviceable cable complete all as specified and directed. Make - Gloster / RR cable/ Havells / Finolex
All as per ser item No. 118 here-in-before but 10 sqmm x 2 Core
M&L for electrical high insulation tape roll of 25mm wide and 25 Mtr length (RYB) for repair/maintenance of cables joining in panels (1100 Volts)/ conductors or fixing of thimbles or colour coding of cables in panels/joints and installation of security lights in poles etc complete all as specified and directed.
S&F street light panel 6 KW suitable for three phase MCB rating 40 Amps on /off timer Astronomical, contactor rating 32 Amps including internal wiring in built short circuit protection, IP-54 and by pass arrangement complete all as specified and directed.
S&F in repairs 8 KW, single phase nature switch for automatic switching on / off street light based on lux level of nature light, consisting of sensor, overload protection fuse gear, power contactor and MCB of suitable capacity, terminal blocks for cable entry & control unit enclosed in pole / wall mountable enclosure made out of rust proof, shock proof, termite proof FR grade SMC, conforming to IP 54, with universal lock and key arrangement complete all as specified and as directed. Make - Sweep, L&T, Hager, Havells
M/S Noor Mohammad Shalla (BID ID -3477957)
M/S Sky Engineers (BID ID -3477914)
M/S MARSHAL TRADERS (BID ID -3473017)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
Tender94.pdf
Tender Documents • 1.15 MB
BOQ_823431.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid