| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹6.9 L+₹2,763 (0.40%)Rejected-Finance VILL KSHETRAHAT P O PAYAG DIST PURBA MIDNAPUR PIN 721 154 | PAYAG | PURBA MIDNAPUR | WEST BENGAL | 721154 | L2 | Rejected-Finance Rejected_Fin | |
| 3 | L3₹6.9 L+₹5,981 (0.87%)Rejected-Finance 1 39 VIVEKANANDA PARK 291 NEW SHIBTALA ROAD BANSDRONI KOLKATA 700070 | KOLKATA | KOLKATA | WEST BENGAL | 700070 | L3 | Rejected-Finance Rejected_Fin |
Tender Value
₹7.4 L
EMD Value
₹14,800
Closing Date
3 Dec 2024, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE_II, Kol. South Health El. Divn.,P.W.Dte.
75 D H Road Kidderpore Kol_23
Conversion of old Dialysis Room of IPD Building first floor into on duty doctors call room at M R Bangur Hospital, Tollygunge, Kolkata under RATTIRER SHATHI Programme-EI work incl. installation of AC System.
2024_WBPWD_762209_1
WBPWD/EE-II/KSHED/Q71/24-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
21 days
Kolkata
Please refer Tender documents.
3 documents required · 3 mandatory
₹14,800
4 Apr 2025
4 Oct 2024
5 Dec 2024
4 Oct 2024
3 Dec 2024
10 Oct 2024
Amount
Dismantling of existing electrical wirings and mending good damages to original finish
S/F Double Door 6-Way Enclosure TPN MCB PDB with 1 No. 415V., 63A. 4-Pole Isolator ,18 nos. 240 V. 16-32 A 'C' series SP MCB as outgoing with IP-42/43 protection, complete with DIN Channel, Neutral Bar, Earth Bar and other accessories flushed in wall / on angle iron frame on wall, & mending good the damages to original finish incl. inter connection with suitable size of Cu wire and neutral link & provision for earthing attachment. (Legrand/seimens/L&T/ABB)
Supplying and fixing 2 + 10 way double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment Incl. Supplying and fixing 240 V MCB Isolator/MCB on din rail of it and necessary connection as required. Incoming - 40 A DP MCB Isolator --1 nos outgoing--6-16A SP MCB of Breaking capacity 10kA & C characteristics--10 nos Make-Legrand/ABB/LK)
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex/ Havells/ Polycab/Gloster) in 20mm size PVC rigid conduit 'FR' (Precision MMS / Polycab MMS make) , with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 3 no. suitable size “Ph & N” & E copper bar incl. bakelite/Perspex (wall matching colour) top cover 3 mm thick and incl. 175mm x100mm x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish Avg run 8 mtr.
Distribution wiring in 1.1 KV grade 3 x 22/0.3 (1.5 sq. mm) single core stranded 'FRLSH' PVC insulated & unsheathed copper wire (Finolex/ Havells/ Polycab/Glosterl) in 20 mm size MMS PVC rigid conduit 'FR' (Precision MMS / Polycab MMS make) to 6 A, 5 pin flush type plug socket & Piano Key type switch (Anchor) fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite (wall matching colour) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish - On Board
Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing 240 V, 2 nos. 6A, plug socket with separate 2 nos. 6 A Piano key type switch, (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 175x100x65mm MS (16SWG) switch board and Bakelite/Perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/Perspex cover and making necessary connections as required
Supply & Fixing 240 V, 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board incl. S & F 00x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing 240 V, 20 A plug socket (Brand approved by EIC), without plug top and switch on sheet metal switch board incl. S & F 100x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire ((Havells/Finolex/Gloster)(Brand approved by EIC) in 20/40 mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required
2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2 x 36/0.3 (2.5 sq. mm) + 1 x 22/0.3 (1.5 sq. mm) ECC
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC 20 mmPVC pipe
2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC
4 x 16 sq.mm. +2 x10 sq. mm as ECC 40 mm PVC pipe
Finishing of the PVC insulated wire ends by socketing with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
2 x 1.5 sq. mm + 1 x 1.5 sq. mm as ECC
2 x 2.5 sq. mm + 1 x 1.5 sq. mm as ECC
2x4 sq. mm +1x2.5 sq. mm as ECC
2x6 sqmm + 1x 4 sqmm as ECC
4 x 16 sq.mm. +2 x10 sq. mm as ECC
Supply and fixing of 240 V , 50Hz Recessed Mounted LED Luminaries having luminous flux not less than 3000 lumens ( efficacy -100lm/W), CCT of 6500k ,ingress protection of IP20 , CRI>80(as per cat no.RC380B LED 30S-6500 G6 L60 W60 PSU OD S1 of MAKE Philips incl all accessories( like GI wire ,hooks etc for proper support ) and necy connection by 3x1..5 sqmm PVC insulated Cu Wires required.of Make : Philips / Lighting Technololgy / Wipro )
Supply and fixing of 240 V , 50Hz Recessed Mounted LED Luminaries having luminous flux not less than 600 lumens ( efficacy -100lm/W), CCT of 6500k ,ingress protection of IP20 , CRI>80(as per cat no.DN295B LED 6S-6500 PSE WH S2 of MAKE Philips incl all accessories( like GI wire ,hooks etc for proper support ) and necy connection by 3x1..5 sqmm PVC insulated Cu Wires required.of Make : Philips / Lighting Technololgy / Wipro )
Supply of DOUBLE industrial type (polycarbonate) 4 ft long LED tube light fittings complete with driver and all accessories incl. supply of 2 no's 20 W T-8 LED Tube light with aluminium/metal heat sink having lumen output not less than 2000 and colour temperature -6500K as per approval of EIC, ( Make : Philips / CG / Havells ) ( Ref-TMC 502 P 2xT-LED 22W (Fittings) Philips master)/or similar of CG/ Havells)
Supply of 250V. 50 Hz. 1320 rpm 400 mm cabin Fan (As per make EPC Tempest) having complete metal body and blades and wattage not more than -50 W and min air displacement of 75 cm/min ( Make : Cinni /EPC/Orient )
Supply of 250 V. 230 mm( 9") 1370 RPM A.C. Exhaust fan approx. consumption of watt no more than 55 W . (make E.P.C./Orient/Crompton make).
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:23 cm (9")
Supply & Fixing GI louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long)--23 cm (9")
Fixing only cabin fan on wall by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length
Fixing only single/twin LED light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with suitable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Supply & fixing 240 V 25ATimer controller for AC machine in SS double door (2+10) way DB enclosure with IP-43 ( Make-LK ) or equivalent with S&F following electrical accessories & front door key locking arrangement with all connection by finishing the ends of 2 x 4 & 1 x 2.5 copper wire dowels solder less socket by crimping method as to GS earthing attachment on wall Inc. Necessary connections as per direction of EIC:- i) 10kA C-curve,240V 25A DP MCB (LK/Schindler/ABB)---1 no. ii) 24 Hr programmable digital time switch(L& T/Schindler/ABB)---1 no. iii) 2 pole power contractor (L&K make cat no MNX22/230) ----1 set iv) LED indicator( Red/Green) ---- 1 Set v) 3 Module plate with cover-----1 no. vi) 20A auto-off-bypass SPDT toggle switch(Approved make/reputed make)-----1 no. vii) 10 A Modular type switch-----1 no. viii) Outgoing connection make ELMAX(Approved make)-----1 no ix) Modular starter 25A --- 1 No etc internal wiring complete with railway type locking arrangement on door.
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C?Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy.Connections.
Supply of 1.1 Tr. Capacity Rated Split type Air - Conditioner Machine cooling capacity 5300 watt .,Rated Power input 1532 watts,ISEER 3.59,Current drawn cooling 6.0-7.5 Amps.supply of 230 Volt AC 50 Hz.Split type Air - Conditioner Machine having features modes (Auto, cool,fan,dry ) air flow ( horizontal louver/vertical swing) sleep mode timer off/on anti freeze thermostat bio/active carbon/dust air filter(Make: O-General)/ Mitsubishi Heavy Duty/Daikin / Hitachi ) with star rating 3/2 including initial charging of cooling agent R410A gas.
Supply of 2.0 Tr. Capacity Rated Split type Air - Conditioner Machine cooling capacity 6212 watt .,Rated Power input 1732 watts,ISEER 3.59,Current drawn cooling 8.0-9.2 Amps.supply of 230 Volt AC 50 Hz.Split type Air - Conditioner Machine having features modes (Auto, cool,fan,dry ) air flow ( horizontal louver/vertical swing) sleep mode timer off/on anti freeze thermostat bio/active carbon/dust air filter(Make: O-General)/ Mitsubishi Heavy Duty/Daikin ) with star rating 3/2 including initial charging of cooling agent R410A gas.
Installation, testing and commissioning of 2.0/1.1 TR Capacity R410A Ref Gas split air conditioner with iron braket (power coated) including initial charging of cooling agent R410A gas and all necessary fittings and fixtures ,angle support etc. as required by site condition.
SITC of Copper Refrigeration pipe line for liquid and suction line with hard drawn copper piping with supports & brackets.
SITC of liquid line incl.3/8 '' or 1/4 '' dia thickness 0.7 mm with nitrile rubber insulation of 3 mm thick having aluminium foil wrapping and coating over insulation.
SITC of Suction line incl.5/8 '' thickness 0.8 mm with nitrile rubber insulation of 19 mm thick having aluminium foil wrapping and coating over insulation.
Supply & drawing 3 core 2.5 sq. mm. P.V.C. insulated wire for connecting the Power hub to Outdoor unit supply. (Make Finolex/RR Kabel /Havells) .
Supply & drawing 4 core 1.5 sq. mm. P.V.C. insulated wire for connecting the outdoor to indoor supply.(Make Finolex/RR Kabel /Gloster)
Supply & laying of 3/4 '' PVC flexible drain pipe.
S&F of 50 mm dia flexible hose to protect the pipe insulation at roof side from birds.
S&F of 25 mm heavy type (40 Grade) UPVC pipe with necessary elbows,connector,solvent cement & clamps. (Make: Supreme).
Defect Liabibility Period 1 (One) year
Make & model of each and every material to be approved by EIC
JAI GURU ELECTRICALS (BID ID -5793364)
BIKASH ENTERPRISE (BID ID -5714800)
technical_1687299.pdf
PDF • 0.22 MB
techsummary_1687299.pdf
PDF • 0.22 MB
finance_1687299.pdf
PDF • 0.55 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_1687299.pdf
PDF • 0.55 MB
AOC.pdf
PDF • 0.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .