| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹12.1 L+₹36,489.26 (3.11%)Rejected-Finance R O IQBAL MARKET AALI MAJID EIDGAH SRINAGAR KASHMIR | SRINAGAR | JAMMU AND KASHMIR | 190001 | L2 | Rejected-Finance Being L2 |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
20 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE HQ 134 Wks Engrs
HQ 134 Wks Engrs PIN 914134 c/o 56 APo
PROVN OF STORAGE ACCN FOR TECH STORES UNDER AGE (I) CIF (K)
2021_MES_462290_1
134 WE-17/2021-22
Open Tender
Civil Works
Item Rate
180 days
Srinagar
Please see tender Documents
8 documents required · 8 mandatory
₹500
AGE (I) CIF (K)
₹29,000
Yes
7 Sept 2021
23 Jul 2021
23 Aug 2021
23 Jul 2021
20 Aug 2021
7 Aug 2021
60 days
Amount
Excavation in trenches, not exc 1.5m wide and not exc 1.5m in depth for foundation and getting out in any type of soil, etc complete all as specified and directed.
M&L Plain cement concrete (1:4:8), type D-2 (using 40mm graded crushed stone aggregetes) as in foundations, filling and mass concrete including demolition of old (un-reinforced) cement concrete of any despcription complete all as specified and directed by Engr-in-Charge.
Brick work with sub class "B" bricks straight or curved on plan exceeding 6 metre mean radius in cement mortar 1:6 complete, all as specified and directed by Engineer-in-Charge.
Formwork to sides of concrete foundations, footings, bases of columns , raft and raft beams, sides and soffits ( if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces complete all as specified and directed by Engr-in-Charge.
Use & waste for formwork sides of Pillars, posts, sturts, piers, columns and stanchions for fair finished surface complete all as specified.
Formwork to sides & soffits of floor or roof beams, lintels, cantilevers, shelves including supports, overhangs for fair finished surfaces of concrete etc complete all as specified and directed.
RCC, M-25 (Design Mix), using 20 mm graded crushed stone aggregates as in foundation footing, plinth beams, base of columns and mass concrete, complete all as specified and directed by Engr-in-Charge.
RCC M-25 (Design mix) using 20mm graded crushed stone aggregate as in beams, cantilevers, lintels over 1.5m span etc complete all as specified and directed.
RCC, M-25 (Design Mix), using 20 mm graded crushed stone aggregates as in coloumns, pillers piers post and struts etc; complete all as specified and directed by Engr-in-Charge.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-Charge.
All as as per item No 10 above but 6 to 8mm dia
M&L for filling under floors with available earth incl spreading and leveling in layers not exceeding 25cm thick, well ramming and watering as requried.
Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface with broken boulders or stone etc complete all as specified & directed.
M&L for 100mm thick, PCC, (1:4:8), type D-2 (using 40 mm graded crushed stone aggregates) as in sub base of flooring without using extra cement complete all as specified and directed by Engr-in-Charge.
18-20mm thick machine cut kota stone slab flooring of size not less than 550x550mm set and jointed in neat cement slurry and pointed in coloured epoxy grout to match laid over and including 20mm thick screed bed in CM 1:4 (surface finished even and rough to receive kota stone) including rubbing and polishing including roughening surfaces of existing concrete floor by picking, sweeping clean & washing down with water to remove dust and apply neat cement slurry @ 3.00kg of cement per sqm, etc complete all as specified and directed.
10-12mm thick machine cut kota stone in skirting to match in size and pattern with kota stone flooring, set and jointed in neat cement slurry and pointed in coloured epoxy grout to match laid over and including 10mm thick backing coat in cement mortar 1:3 (surface finished even and rough to receive kota stone) including rubbing and polishing including dismantling existing plastering and removal of debris out off premises etc complete all as specified and directed.
S&F of 4mm thick non absestos fibre cement building board fixed in Anodized aluminum snap grid frame work for false ceiling, size of grid 605mmx605mm, runners of size 15x32mm with hangers of 6mm dia GI (up to 1200mm length) adjusting level, fixed to roof by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified and directed by Engr-in-Charge. all as specified. Make: Everest, Armstrong or its equivalent as approved make.
Returning, filling in trenches, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick, etc complete all as specified and directed.
Removing excavated material (soil) to a distance not exc. 500m and depositing where directed, etc complete all as specified and directed.
Rolled mild steel in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors, etc., to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings ( exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Fe- 290 (Gde E- 165) , complete all as specified and directed by Engr-in-Charge.
S&F 1.25mm thick MS plain black sheet framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc complete, drilled for fixing of steel sheeting or other covering. Doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging foot fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete (Fe-410-W(Gde-E-250) quality-B
4mm thick sheet glass ordinary quality and glazing with oil putty or fixed with beads/ glazing pins not .exc 0.5sqm in each pane etc, complete all as specified and directed.
Steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay, complete with glazing bars dovetailed or welded all as specified and directed by Engr-in-Charge.
M&L for 15mm thick rendering in CM 1:6 on fair faces of brick/concrete/stone wall surfaces for any description and finished even and fair without using extra cement complete all as specified or directed by the Engr-in-Charge.
M&L for 15mm thick rendering in CM 1:4 on other than fair faces of brick/concrete/stone wall surfaces for any description and finished even and fair without using extra cement complete all as specified or directed by the Engr-in-Charge.
Preparation of newly plastered surfaces of wall & applying two coats of colour wash over one coat of white wash including necessary scaffolding etc complete all as specified and directed.
Preparation of newly plastered surfaces of wall & applying two coats of cement base paint over one coat of alkali primer including necessary scaffolding etc complete all as specified and directed.
Framed steel work such as in roof trusses, trussed purlin, crane gantries rails and fastening and heavy bracket framing (beam,tee,angle ,channel or flat section) including dIstances pieces ,cleats etc of Fe-410 W , Gde E-250 , complete all as specified and directed by Engr-in-Charge.
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,length of bolt exceeding 22.5cm but not exceeding 30cm long, diameter of neck 11mm to 15mm complete all as specified and directed by Engr-in-Charge.
Mild steel plain plates as in base/cleat/jointing plate/purlins/ rafters, conforming to Fe 410-W (Gde E-250, Quality 'A') square cut or notched (ordinary & counter sunk) forming holes with riveted, bolted or welded attachment etc complete all as specified and directed.
Pre-painted galvalume 0.5mm thick high strength corrugated sheeting with aluminium zinc coating of an ecofriendly colour coating not less than 25 micron having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws as required etc complete all as specified and directed.
Pre-painted galvalume 0.5mm thick high strength plain sheeting with aluminium zinc coating and 600mm width of an ecofriendly colour coating not less than 25 micron having tensile strength of 550 Mpa as in ridges, fixed with self tapping screws as required etc complete all as specified and directed.
S&F 1mm thick plain, black, mild steel sheeting as in eaves boarding etc compelte fixed with welded or solders joints.
Preparation of new or previously untreated steel surfaces of any description, not otherwise, described, over 10cm width or girth and applying two coats of synthetic enamal paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
75mm thick PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in plinth protection laid in panels and joints filled with mix of bitumen and sand (1:3) by weight, finished the surface even and smooth using extra cement etc complete all as specified and directed.
Supplied only liquid water proofing compound
Point wiring using FR PVC insulated unsheathed /multi stranded copper conductor cable 1.5 sqmm including 1.5 Sqmm FR PVC insulated unsheathed copper conductor earth wire drawn through and including concealed PVC conduit of appropriate size not less than 20 mm dia and 1.8 mm thick including all fittings viz tees, bend, junction box and pressed steel sunken box 60 mm deep & 1.6 mm thick duly painted inside and anticorrosive out side for mounting switches, sockets, fan regulators etc with 3mm thick plastic laminated sheet cover of suitable size, connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing including connection of cable with MCBs or bus bar shall be done through proper size copper/brass thimble of pin/u type etc (conduit shall be fixed on surface of ceiling with necessary saddles where concealing of conduit is not feasible), for light/fan/bell point etc complete all as specified and directed. (Note : Switch/bell push/fan regulator etc shall be measured and paid separately)
All as per above item No 37 but here-in-before 5 PIN socket out let 5 Amp on the independent board complete all as specified and directed by Engr In Charge
All as per above item No 37 but here-in-before 5 PIN socket out let 5 Amp on the same board complete all as specified and directed by Engr-in -Charge
All as per above item No 37 but here-in-before 5 PIN socket out let 15 Amp on the independent board with 2.5 sqmm for phase and neutral and 1.5 sqmm for earthing complete all as specified and directed by Engr In Charge
S&F in replacement sheet metal enclosure factory made ( double door) shutter type for DB SPN, 240 Volts, 8 ways within 200 Amps rated bus bar, neutral link, earth bar complete
MCB single pole (SPN) 240 volts, 40 to 63 Amps, 10KA (C-series) of approved make and cat part etc complete all as specified and directed.
MCB single pole (SP) 240 volts, 6 to 32 Amps, 10KA (C-series) of approved make and cat part etc complete all as specified and directed.
Switch piano flush type, single pole, 6 Amp, one way, AC 230 volts etc complete, all as specified and directed. Make : Anchor (Penta) Cat Part No : 38014 or equivalent of Havells/SSK
Socket outlet, 2 in 1, 5 pin, 6 Amp, flush type, AC 230 volts etc complete all as specified and directed. Make : Anchor (Penta) Cat Part No : 38364 or equivalent of Havells/ SSK
Switch piano flush type, single pole, 16 Amp, one way, AC 230 volts etc complete, all as specified and directed. Make : Anchor (Penta) Cat Part No : 38477 or equivalent of Havells/ SSK
Socket outlet, 2 in 1, 5 pin, 6 Amp & 16 Amps, flush type, AC 230 volts etc complete all as specified and directed. Make : Anchor (Penta) Cat Part No : 38397 or equivalent of Havells/ SSK
Ceiling rose polycarbonate isolated body surface Bakelite, not less than 50x20mm, three terminals, AC 230 volts etc complete all as specified and directed. Make : Anchor (Penta) Cat Part No : 39040 or equivalent of Havells/ SSK
Surface mounted 1x18 watt LED tube light fittings (4 feet long), prewired, decorative integrated luminaire with inbuilt LED tube rod and acrylic end caps with all accessories and PVC Round/Square block for fixing of fittings and making connection using 3 core, 0.50 Sqmm PVC insulated and overall sheathed flexible copper conductor cable from ceiling rose/PVC connector to light fitting and testing etc complete all as specified and directed. Make : Crompton Cat Part No LDSL 18-CDL or equivalent of Wipro/Philips Note : CA No shall be written on each fitting before installation.
1100 volt grade XLPE insulated heavy duty cable, 16 sqmm 2 core, strip armoured with aluminium stranded conductor overall PVC sheathed laid in trenches including taking down existing cable etc complete all as specified and directed. Note : Excavation & Earthwork shall be measured and paid separately.
S&F GI Pipe light grade ISI marked including all fittings on wall or laid on floor as reqd position of size 50 mm bore for protection of cable in trenches/under road complete, all as specified and directed by Engr-in- Charge.
Excavation in trenches, not exc 1.5m wide and not exc 1.5m in depth for laying of cable/pipes and getting out in any type of soil, etc complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick, etc complete all as specified and directed.
Removing excavated material (soil) to a distance not exc. 50m and depositing where directed, etc complete all as specified and directed.
Supply & spreading in trenches clean dry sand including gently punning around cable, etc complete all as specified and directed. (Note: Punned thickness shall be measured)
Brick well burnt locally available sub class "B" laid over sand cushioning to cable in trenches keeping width of brick parallel to the length of cable all as directed.
Earthing complete with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below ground level connected to galvanized iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point, GI tubing 15mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel and wire mesh, charcoal and salt, 40mm thick pre-cast RCC (1:2:4) type B-0 (Nominal mix) cover reinforced with XPM (weighing n.less than 4 Kg/Sqm) with suitable steel handle, and angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-0 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, complete all as directed. Notes: 1. Earth lead & protection pipes length upto & including 7.50 metre. 2. Earth filling shall be done by vegitable soil. 3. Soil should be free from stone, boulders, aggregate, gravels etc.
M/S SHIMAR STAR GLACIER
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .