Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.4 LAccepted-AOC NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L1 | Accepted-AOC L1 | |
| 2 | L2₹27.7 L+₹2,643.50 (0.10%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹29.1 L+₹1.4 L (4.89%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹30.5 L+₹2.8 L (10.1%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹35.4 L+₹7.7 L (27.9%)Rejected-AOC 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L5 | Rejected-AOC L5 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
12 Dec 2022, 6:00 pmClosed
GE Bharatpur
Kanjoli line Bharatpur
Repair to LT External electric supply, LT Cables, LT OH lines, LT panels and connected works at 39 FAD Mil Stn Bharatpur
2022_MES_562200_1
8209/E8
Open Tender
Civil Works
Item Rate
180 days
GE Bharatpur
as per tender doucment
6 documents required · 6 mandatory
₹500
GE Bharatpur
₹60,000
Yes
6 Jan 2023
10 Nov 2022
19 Dec 2022
10 Nov 2022
12 Dec 2022
28 Nov 2022
12 Nov 2022 - 25 Nov 2022
Amount
Excavation in trenches, n. exc 1.5 Mtr wide and n. exc 1.5 Mtr in depth for foundation/laying of cable and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers n. exc 25 cm thick complete all as specified and directed.
Removing of excavated soil to a distance n. Exc 50 Mtr and depositing where directed at a level n. Exc 1.5 Mtr above the starting point complete all as specified and directed.
Supply & spread unwashed dry river sand for sand cushioning for covering the under ground cable in trenches. complete all as specified and directed. (Note :- Punning thickness shall be measured.)
M&L for cable protection cover with sub Class`B` bricks old size laid dry, flat perpendicular across the cable in trenches complete all as specified and directed.
Taking out Unsv U/G cable PVC insulated armoured PVC sheathed / Al. Conductor, LT type of 10 sqmm to 16 sqmm any size complete all as specified and directed.
Taking out Unsv U/G cable PVC insulated armoured PVC sheathed / Al. Conductor, LT type of 25sqmm to 50 sqmm any size complete all as specified and directed.
Taking out Unsv U/G cable PVC insulated armoured PVC sheathed / Al. Conductor, LT type of 70sqmm to 120 sqmm any size complete all as specified and directed.
Taking out Unsv U/G cable PVC insulated armoured PVC sheathed / Al. Conductor, LT type of 185sqmm to 400 sqmm any size complete all as specified and directed.
dismantling of old UNSV ACSR conductors of weasel with permissible sag as per IS rules etc complete all as specified and directed.
Diismantling of old UNSV cross arm from PCC Pole & taking down with connected nuts & bolts complete all as specified and directed by Engineer in Charge.
Dismantling of old UNSV Pin insulator from PCC Pole & taking down with connected items complete all as specified and directed by Engineer in Charge.
Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole of the following sizes:-
(a) 400 Sqmm 3.5 core
(b) 300 Sqmm 3.5 core
(c) 185 Sqmm 3.5 core
(d) 120 Sqmm 3.5 core
(e) 70 Sqmm 3.5 core
(f) 50 Sqmm 3.5 core
(g) 25 Sqmm 4 core
(h) 16 Sqmm 4 core
(j) 10 Sqmm 2 core
Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable of single core 150 Sqmm with stranded copper conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole complete all as specified and directed.
S&F in repair of MCCB in existing location of following capacity :-
(a) MCCB 415 volts thermal magnetic release adjustable type 400 Amps 04 pole 36KA complete all as specified and directed.
(b) MCCB 415 volts thermal magnetic release adjustable type 250 Amps 04 pole 36 KA complete all as specified and directed.
(c) MCCB 415 volts thermal magnetic release adjustable type 200 Amps 04 pole 36 KA complete all as specified and directed.
(d) MCCB 415 volts thermal magnetic release adjustable type 160 Amps 03 pole 36 KA complete all as specified and directed.
(e) MCCB 415 volts thermal magnetic release adjustable type 100 Amps 04 pole 25 KA complete all as specified and directed.
(f) MCCB 415 volts thermal magnetic release adjustable type 63 Amps 04 pole 25 KA complete all as specified and directed.
(g) MCB TPN 63Amps C curve 415 V, 10 KA complete all as specified and directed.
Taking out old u/s pipe of any size complete all as specified and directed.
S & F or laying galvanised steel tubing light grade (ISI marked) for protection of under ground cable on poles/walls under road crossing of following sizes:-
(a) 40 mm bore
(b) 50mm bore.
(c) 100mm bore.
Boring under roads / pavement / hard standing without disturbing the top surface by trench less technology using necessary machine including Supply & inserting HDPE pipe of 90 mm dia suitable for 0.4 mpa working pressure for passing through the cables complete all as specified and as directed. Note : Necessary infrastructure required for boring shall be arranged by the Contractor at his own cost.
M&L for LT cable fault rectification of following sizes given by using Fault locator machine to detect fault and rectify the same incl T&P & items ie lugs,tape etc complete all as specified and directed. :-
(a) 16 sqmm to 50 sqmm X 3.5/4 core
(b) 70 sqmm to 120 sqmm X 3.5 core
(c) 150 sqmm to 400 sqmm X 3.5 core
M&L for cable jointing kit for 1.1 KV grade for straight through joint complete with jointing material and accessaries suitable for 3.5/4 core XLPE armourd aluminium conductor cable of following size after detaction of fault location complete all as specified and directed. :- Note: Quoted rates for earth work and returning filling which required shall be included in the item.
(a) 16 Sqmm to 25 Sqmm
(b) 35 Sqmm to 50 Sqmm
(c) 70 Sqmm to 120 Sqmm
(d) 150 Sqmm to 400 Sqmm
Shifting of LT XLPE underground cable with proper connection in trenches / pole etc, aluminium conductor of any sizes complete all as specified and directed by Engr-in-charge. Note:- Excavation with Earth Work,sand cushioning will be measured and paid under respective item of BOQ.
Taking out old PCC cable cover & Re-laying after shifting of cable any type / any size from trenches complete all as specified and directed.
Supply & fix in repair High performance microprocessor based 3 phase APFC relay in control panel with Auto/Manual Option including control CT & control wiring of the panel.
Material and Labour for cleaning of dust particles from inside the LT Panel by air blowers, tightening of loose connections, filling of gaps with sealants, removing of vegetation, surface dressing surrounding the panel, welding of damaged panel doors, fixing of hinges, providing locking arrangements, applying one coat of primer, painting of panel with two coats synthetic enamel paint of existing colour complete including providing lock all as specified and directed by Engr-in-charge.
M& L for Earthing complete with galvanised mild steel plate electrode 600x600x6 mm thick buried directly in ground vertically (earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate electrode at a depth not less than 1.5m below normal ground level and including GI earth strip 32x6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate electrode at one end connected to metallic bodies of HT/LT equipment etc at the other and earth strip encased in and including 40mm bore GI light grade pipe with all fittings from top of earth plate electrode to body of equipment fixed with and including 25x6 mm flat iron clamps bolts, nuts and washers and including providing watering pipe 20mm bore GI Pipe electrode complete all as specified and shown in elctrical plate No 3 of MES SSR Part-I. the scope of work includes necessary excavation and earth work in any type of soil. removal of soil upto 50 metre PCC pit with precast RCC cover, charcoal/salt funnel, CI frame etc complete all as specified & directed. NOTE: (I) The concrete pit shall be made in PCC 1:2:4 type B-O, using 12.50 mm graded crushed stone aggregate 40mm thick precast cover slab of RCC(1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover. Reinforcement in cover shall be of 8mm dia TMT bars @ 150mm c/c both ways. (ii) Item includes the cost of 7.5 metre GI pipe for protection of earth strip. (iii) Item includes cost of 7.5 metre earth lead strip (iv) Earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thinkness of 15 cm on all sides.
Demolition of old PCC and M&L for cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate for pedestal of poles/ coping including necessary formwork, fair finishing to exposed surfaces using extra cement complete all as specified and directed.
M&L Danger notice plate for LT of size 20 x 15cm and 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size complete all as specified and directed.
S&F ON LOAD change over switch 415V with & including outdoor type sheet metal enclosures (sheet thickness 3.15 mm ) including necessary angle iron stand grouted in PCC, 4 pole of capacity 200 Amps with in and out cable gland complete as specified & directed.
S&F ON LOAD change over switch 415V with & including outdoor type sheet metal enclosures (sheet thickness 3.15 mm ) including necessary angle iron stand grouted in PCC, 4 pole of capacity 100 Amps with in and out cable gland complete as specified & directed .
Supply and laying of Aggregate for protection of LT panel gauge 20 mm to 40 mm grade complete all as specified and directed at site.
Supplying and laying synthetic Rubber insulated mats mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m
Supply and fixing of Lithium base Energy efficient integrated Solar street light of 32 watt in single FRP body duly polyurethane coating (Camouflage color), encases with monocrystalline solar PV panel of 65-67Wp,lithium battery 11.1/12.8V,33.0 AH with inbuilt BMS,IP 65, High brightness W-LED(160-180lm/watt) lamp with Aluminium reflector for better light distribution ,CRI>70, color temp 5700K-6500K Microcontroller based charge controller cum driver,automaticdimming function(First 04 hrs at full brightness & rest of the time at lower light level with PIR motion sensor), Dusk to dawn operation,suitable to working temp (-) 10C to (+) 55C ,weight not more thatn 16-18 Kg with adjustable MS clamp suitable for pole/wall mounting etc complete as reequired.Make: AXXON/HAVELLS/PHILLIPS Protections: Short circuit, overload,Reserve polarity and battery protection.Firm should provide vital parametres Test report from NABL accredited lab and should be of made in India with CE & ROHS complaint.
GANGA CONSTRUCTION
krishna Associate
M/s Ranaji Construction Co
PD GUPTA AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .