| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.2 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹36.3 L+₹66,152.13 (1.86%)Rejected-AOC | L2 | Rejected-AOC Rejected being L2 | |
| 3 | L3₹36.7 L+₹1.0 L (2.89%)Rejected-AOC | L3 | Rejected-AOC Rejected being L3 | |
| 4 | L4₹37.0 L+₹1.4 L (3.87%)Rejected-AOC | L4 | Rejected-AOC Rejected being L4 | |
| 5 | L5₹37.1 L+₹1.5 L (4.24%)Rejected-AOC | L5 | Rejected-AOC Rejected being L5 |
Tender Value
₹32.6 L
EMD Value
₹65,220
Closing Date
18 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 867 EWS
GE 867 EWS C/O 99 APO PIN-913867
PROVISION FOR ROOM FOR DRYING AND IRONING NEAR BLDG NO D-29, SEPTIC TANK FOR TOILET CUBICLES, SHED FOR GENR NEAR BLDG NO P-106 AND 02 X SOLAR GEYSERS CAPACITY 500 LTRS AT ALGARAH, AP ALGARAH, DALAPCHAND UNDER GE 867 EWS
2023_MES_614759_1
GE/867/TOKEN/43 OF 2023-2024
Open Tender
Civil Works
Item Wise
180 days
KALIMPONG
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE 867 EWS
₹65,220
10 Nov 2023
21 Aug 2023
20 Sept 2023
21 Aug 2023
18 Sept 2023
4 Sept 2023
21 Aug 2023 - 31 Aug 2023
Amount
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft / loose soil complete all as specified and directed.
Excavating over areas, n exc 1.5 m deep and getting out in Soft/ loose soil complete all as specified and directed.
Excavating over areas, exc 1.5 mtr but not exc 3.00 mtr in depth; for foundation etc. and getting out in hard/dense soil complete all as specified and directed.
Excavation in post holes (or similar holes) each not exc 0.5 cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25 cm watering, and removing surplus soil to a distance not exc 50mtr and making good surface in soft/loose soil complete all as specified and directed.
Removing excavated material n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point in soils complete all as specified and directed.
Returning filling in , including, spreading, levelling, watering and well ramming in layers not exc 25cm in soft / loose soil complete all as specified and directed.
M&L broken stone or bounders hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick , watered and rammed to a floor/true surface complete all as specified and directed.
M & L hardcore of gauge exc 63mm but n exc 100mm,deposited, spred and levelled in layers n exc 15 cm thick watered and rolled /rammed to a true surface complete all as specified and directed.
M & L PCC (1:4:8) type D-2 (Using 40 mm grade aggregate) in foundation, filling and mass concrete complete all as specified and directed.
M &L for 150 mm thick PCC (1:4:8) type D-2 (Using 40 mm grade aggregate) as in floor finsh even and smooth without using extra cement complete all as specified and directed.
M&L for 75 mm thick PCC (1:4:8) Type D2 (using 40 mm graded aggregate) as in sub base of floor complete all as specified and directed.
M&L for 40 mm thick PCC (1:2:4) Type B1 (using 20 mm graded aggregate) as in floor fininsh complete all as specified and directed.
M&L for 38mm wide glass dividing strips 3mm thick as in floors complete all as specified and directed.
M&L for 75 mm thick PCC type C-2, (1:3:6) (40mm graded stone aggt) as in path, plinth protection etc., complete all as specified and as directed.
M&L for PCC (1:3:6) type C-1 (using 20 mm graded crushed stone aggregate) as in surface channels, drains including all necessary form work complete all as specified and directed.
M&L for Non Skid ceramic colour tilles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11sqm but not exceeding 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed or bedding layer of mortar 10 mm thick for fixing wall tiles in CM (1:4) complete all as specified and directed.
M&L for glazed ceramic coloured tiles (300 x 200mm) x 6mm thick on vertical surfaces such as skirting , dados & risers to steps set & Jointed in neat cement slurry & pointed in colored cement to match over screed bed or bedding layer of mortar 10 mm thick for fixing wall tiles in CM (1:4) complete all as specified and directed.
M&L for chequered cement concrete tiles 250 x 250 x 25 mm thick set, jointed and pointed in neat cement slurry in floors with grey cement and no pigments over and including 15 mm thick screed bed in CM (1:6) complete all as specified and directed.
M & L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius in Cm (1:6) complete all as specified and directed.
M & L Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick wall built with Cm (1:4) complete all as specified and directed.
M & L precast cement concrete type C-1 , (1:3:6) (using 20mm graded stone aggt) block masonry with solid blocks exc 10cm in width and setting in CM (1:6) complete all as specified and directed.
M & L precast cement concrete type C-1 , (1:3:6) (using 20mm graded stone aggt) block masonry with solid blocks 10cm in and setting in CM (1:6) complete all as specified and directed.
M&L 15 mm thick rendering on fair faces of brick work or concrete surfaces in CM (1:6) complete all as specified and directed.
M&L 20mm thick rendering in two layers of 10mm each on brick or block concrete masonry walls in cement plaster (1:4) with WPC incl finished even and smooth w/o using extra cement all as specified.
M&L rendering 15 mm thick in CM (1:4) on fair faces of brick work or concrete surfaces to be finished even and smooth using extra cement mixed with intergral water proofing compound @ 3% by weight of cement (WPC measured and paid separately) all as specified and as directed.
Supply only integral water proofing compound all as specified and as directed.
M&L for preparing newly plaster or untreated plastered wall surfaces and applying three coats of white wash complete all as specified and as directed.
M&L for preparation on newly plastered / previously untreated surfaces of wall and applying two coats of cement base paint over one coat of priming coat with alkali resistant primer complete all as specified and directed.
M&L preparation of new plastered surfaces of walls and applying two coat of OBD over a coat of chalk whiting complete all as specified.
S & F for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. in Fe-410-W (Gde-E-250) quality-A all as specified.
S&F Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 all as specified.
S & F painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
S & F painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified.
M&L preparation of steel and iron surfaces of any description exc 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zink chrome complete all as specified.
M & L Reinforced cement concrete Type B1 1:2:4 (20 mm graded aggregate) Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed
M & L RCC Type B1 (1:2:4) Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilaster and buttresses complete all as specified.
M & L RCC Type B1 (1:2:4) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like., complete all as specified and directed.
M & L RCC type B-1, (1:2:4) (using 20mm graded stone agg) as in foundations, footings, plinth beam etc complete all as specified.
M & L RCC type B-1, (1:2:4) (using 20mm graded stone agg) for columns, pillars, piers, post and struts complete all as specified.
M & L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping complete all as specified and directed.
M & L Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide. (Where RCC/PCC band in walls, spanning and opening complete all as specified.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as specified.
Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter complete all as specified.
Form work to sides of concrete foundations, footings, bases of columns and plinth beam and similer work etc in rough finished surfaces of concrete flat complete all as specified.
M & L for form work to sides of pillars, posts, strurs,piers, columns and stanchions in rough finished surfaces of concrete in square, rectangular or polygonal complete all as specified.
M & L TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
M & L TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
M&L mild steel deformed bars 10mm dia and over cut to length bend to shape required incld cranking bending spirally for hooping for column, hooking ends and binding with and incld mild steel wire (annealed not less than 0.90mm dia or securing with clips complete all as specified.
All as per item No-48 above but 5mm dia and over upto and incld 10mm dia in stirrups, spacer and binders complete all as specified.
S&F GI frame work of size 605 x 605mm, for seamless celing comprising of GI perimeter chanel 0.55mm thick with two unequal flangesof 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/ intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and incl ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre complete all as specified.
S&F 10mm thick PVC insulation panels with EPS stuck to 1mm printed PVC sheet suitably placed in false ceiling grid made of Aluminium/G.I./M.S.complete all as specified and as directed.
S&F Pressed steel door frame for doors, size 165 x 60mm with one rebates incl necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and as directed.
S&F 35mm thick plain framed panelled shutter (any number of panels) of 2nd class H.W with panels of timber flat on both sides or of venerred particle boards medium density, wood particle board with commercial face veeners.
S&F Steel windows with side hung shutters incl projecting type hinges with steel handle, and steel peg stay complete with glazing bars.
S & F 3.0 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc 0.50 Sqm in each pane.
M&L Preparation and applying two coat of synthetic enamel paint over one coat of pink primer on new wooden surfaces, of any description, over 10cm width or girth not other wise described.
S & F 200mm long aluminium anodised barrel tower bolts of extruded sections complete all as specified and directed.
S & F 300 mm long aluminium alloy, anodised sliding door bolt with hasp and staple (bolt type ) and fixing clip of sheet cost or extruded section or cost aluminium alloy & fixed.
S & F 150mm long aluminium handle cost type anodised.
S&F anodised aluminium alloy curtain rail with fixing brackets, stops, rollers etc complete all as specified and as directed.
S&F 4mm dia Plain mild steel wire, galvanised class 3, in detached work such as for mosquito nets, hanging cloths and fixing to straining bolts, hooks, eyes, etc. fixing to wood, concrete or steel posts and/or to straining bolts, including securing with and provision of galvanised iron tying wire, galvanised iron staples or steel pins, etc. as directed (each line of wire to be measured) comlpete all as specified and directed.
S&F of Tie bars with screwed ends, nuts, washers and mild steel plates for walls, chimneys, roofs, arches, hanging cloth wires etc. king rods and straining bolts conforming to Fe 290 Gde-E-165 comlpete all as specified and directed.
S & F PVC (SWR) vent pipe 110 bore fixed to walls complete all as specified.
S & F PVC (SWR) vent cowl 110 bore complete all as specified.
M & L Providing precast cement concrete Type B1 1:2:4 in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified.
S&F PVC (SWR) pipes 110 mm single socketed in any length with rubberring joints, laid in trenches or in floors complete all as specified.
S&F PVC bends any radius 110 mm dia complete all as specified.
M&L for Cement concrete 1:4:8 type D2 (Using 40mm graded stone agg) as in Concrete bed to 110mm drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested all as spfd and directed.
M&L for sand cushioning to U/G cable in layers of 23cm thick( 8 Cm before laying the cable and 15Cm thick after laying the cable) in trenches complete all as specified and directed. Note :- Only Punned layers shall be measured.
Supply and laying reinforced precast concrete cable cover class LV type 1 flaat size 250mmx150mmx40mm laid in trenches for cable protection complete all as specified and directed by Engineer-in-charge.
Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor on wall with the help of shadel of size 10 Sqmm 2.0 core as required at site.
M & L GI tube light grade for passing through cables under the floor ,along the wall or along the pole of 25 mm bore and fixed to the poles/walls with suitable size of MS clamps and nut and botls/washers etc complete all as specified and as directed.
M&L for Point wiring complete with 1.5 sqmm single core PVC insulated and PVC unsheathed FRLS multistranded copper conductor cable 1100 volt grade enclosed in and including PVC casing and capping with accessories fixed on surface on walls/ceiling by means of PVC sleeves, Dash fastners and cadmium plated screws including sunken junction box not less than 3.0 mm thick concealed in wall, mounting accessories like switches, sockets fan regulators with 3.0 mm thick Laminated sheet top covers etc including 1.5 Sqmm single core multi stranded copper conductor PVC insulated and unsheathed cable as earth continuity conductor to common earth dolly for One light point or one fan point controlled by one switch complete all as specified and directed. [make : Polycab/Havells/RR Cables/KEI]
All as per item No 73 here – in – before but for one 3 / 5 -pin switch socket outlet 5 amps on independent board.
All as per item No 73 here – in – before but for one switch socket outlet 15 Amps on independent board with 2.5 Sqmm multi stranded and 4 Sq mm stranded (for earth) PVC insulated un-sheathed copper cable.
Supply and fix switch piano flush button, single pole, 5 amps, one way all as specified and as directed. Make : Anchor/Havells/Plaza
Supply & Fixing ceiling rose surface bakelite 65 X 50 mm three terminal all as specified and as directed. Make : Anchor/Havells/Plaza
Supply and fix switch socket combination 2 – in – one, 3 Pin / 5 Pin, 5 amps flush type all as specified and as directed. Make : Anchor/Havells/Plaza
Supply and fixing switch socket combination 2 – in – one 6 Pin , 5 / 15 amps flush type universal all as specified and as directed. Make : Anchor/Havells/Plaza
Supply and fixing energy efficient LED tube lights fitting 4", 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. Make : Havells/Philips/Crompton
Supply and fixing LED light fitting 1x9W/10W bulkhead luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete including taking down old unsv fitting complete all as specified and directed
S&F lamp/angle holder insulated body with back plate for batten fitting all as specified and as directed. Make : Anchor/Havells/Plaza
S & F in LED retro fit lamp B-22 holder base with poly carbonate body and aluminium heat shrink of 12 W complete all as directed. Make : Crompton/Havells/Surya or equivalent
Supply and fixing exhaust fan, made of sturdy engineeinring plastic complete with louvers shutter 230V 50Hz RPM 1200, copper winding of sweep 250mm as specified and as directed by Engr-in-Charge.
Material & labour for making hole in the existing wall/building without distrubing to existing infrastructure for fixing of exhaust fan complete including making good to match with the existing specification complete all as directed by Engineer-in-Charge.
Supply and Fixing air circulator fan 600mm sweep, made of metal body complete, 230V, 50 HZ, RPM 1440, air delivery 125 CMM, 100W power with double ball bearing as specified and as directed by Engineer-in-charge.
S&F Sheet metal enclouser Double door for MCB DB,s Phosphatised Powder Painted with bus bar 200 Amps rated Single pole and neutral linkof 8 way 240 Volts AC. Make- Legrand or equivalent in Siemens/Schindler.
Supply and fix MCB single pole (SP), 10 kA of 5 -32 Amps capacity 240 Volts, 'C' curve. Make : Legrand or equivalent in Siemens/Schneider
Supply and fix MCB single pole neutral, 10 kA of 40 Amps capacity 240 Volts, 'C' curve. Make : Legrand or equivalent in Siemens/Schneider
M&L for Earthing in repairs complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m bellow normal ground level, connected to galvanized earth lead wire 4 mm dia. by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed , including funnel with GI med grade watering pipe 20 mm bore , wire mesh , charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode , with concrete pit in PCC (1 : 3 : 6) type C-1 , 50 mm thick pre cast RCC (1 : 2 : 4) type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar ,GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I and as directed.
Supply, Install, Testing and Commissioning of 'Solar Hot Water System' (Flat Plate Collector) based on indirect transfer of heat of capacity 500 Litres per day, including Anti freezer chemical Glycol-Non consumable industrial grade( heat exchanger fittings inclusive type) , including collector, collector support, screen, control and instrumentation viz, temperature gauge, minor civil works for foundation and grouting of collector frames as required etc. , works efficiently with hard water with hardness upto 600 ppm and, PUF insulation to ensure that the heat generated is retained for long hours, SS 304 tank with Zinc Alum outer cladding and aluminium support structure complete conforming to IS specification with water piping upto Solar system from nearby SDPE tank including electrical backup accessories required for installation and all minor item required to install the solar water heater as per manufacturer all as specified and directed. Technical specifications required : Section : 1.2mm thick Aluminium, Back sheet : 0.46 mm thick Aluminium'Insulation : Fibre Glass wool with 50mm thick, Foil :0.05 mm thick Aluminium, Flat plate collector fins (9 No’s): Ultrasonic welded with Nalsun coating. Copper pipe 24 SWG, Aluminium strip 0.20mm, Header pipe : Copper 24 SWG, Glazing : 1000 X 2000 X 4mm clear toughened glass, Glass beeding :E.P.D.M. Rubber, Fasteners :Stainless steel, Grommets : E.P.D.M Rubber Flanges : Brass, Finishing :Powder coating, Tank Specification: Inner tank thickness : 2mm for non-pressurized (500L to 1500L) 3mm for pressurized (500L) Inner tank material : HRCA sheet Outer tank material : Pre-Coated laminated sheet(colour: half white)/Mirror finish Insulation: 50mm thick PUF(Polyurethane foaming), Support structure: GL with powder coating Make : Make : RASHMI INDUSTRIES/ TATA BP SOLAR/ SOLOCHROM SYSTEM INDIA LTD/ BHEL/ NILLOY NEM SUN TECHNOLOGIES/ RACOLD/ V GUARD/ SUPREME SOLAR or equivalent as approved by GE.
M & L for construction of angle iron stage made out of MS equal of suitable size of thick complete including fabricated work all as per directed at site.
Supply and fixing of Rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position of 1000 ltr all as specified and directed. Make : Syntex/Infra/ORIPLAST/POLYCON
Supply and laying in wal / ceiling or laid in floors GI steel tubing medium garde including all fittiings such as tees, elbow , bends etc for 20mm bore of pipe complete all as specified.Make : TATA/Zenith/Jindal
Supply and laying in wal / ceiling or laid in floors GI steel tubing medium garde including all fittiings such as tees, elbow , bends etc for 25mm bore of pipe complete all as specified.Make : TATA/Zenith/Jindal
M & L cutting existing steel tubing for alteration or additions (Each cut measured ) and inserting new new Tee , Bend , elbow etc upto 20mm dia all as specified and directed.
Supply and fixing 25m gun metal globe valve iron wheel head screwed both end for iron pipe all as specified and directed.Make : ZOLOTO/DURGA/NMC/NETA/LEADER
Supply and fixing 20m gun metal globe valve iron wheel head screwed both end for iron pipe all as specified and directed.Make : ZOLOTO/DURGA/NMC/NETA/LEADER
M & L for insulation of M S pipe with PUF slab 30mm thick with and including applying bituminous compound and GI cladding with 26 guage GI sheet complee of sizes 20mm bore dia all as directed.
M & L PCC (1:3:6) type C-1 (using 20 mm graded crushed stone aggregate ) as in coping including weathering, slightly rounded or chamfered angles and throating , as directed and necessary from work complete all as specified and directed.
S & F Hot water pipe duly insulated with galss wool and aluminium cladding 25mm bore , incl all fitting (such as bends, eblows , Tees , connectors , short pieces , back nuts , unions , caps and plug etc complete all as specified and as directed.
S & F Hot water pipe duly insulated with galss wool and aluminium cladding 15mm bore , incl all fitting (such as bends, eblows , Tees , connectors , short pieces , back nuts , unions , caps and plug etc complete all as specified and as directed.
S & F Bib taps, cast copper alloy with crutch or butterfly handle , screwed down , screwed for iron pipe or for brass ferrule and fixed, fency type complete all as specified and as directed.Make : ZOLOTO/DURGA/NMC/NETA/LEADER
S& F PVC float valve , high pressure with polythene float and fly nut complete screwed for PVC pipe and fixed in 25mm bore pipe all as specided and as directed.
Note: In case doubling/duplicancy of BOQ items , the lowest quoted rate shall be applicable for payment.
SCHEDULE OF CREDIT
MS BRAHMA CONSTRUCTION
MS MAYA PRAKASH GOEL AND SONS
APARAJITA GROUP OF CONSTRUCTION
DEEP CHANDRA JOSHI
M/S JAYSHREE CONCERN
HEM RAJ GURUNG
G K SUTHAR
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .