Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.4 LAccepted-AOC | L1 | Accepted-AOC BEING L1 BIDDER | |
| 2 | L2₹52.9 L+₹14.4 L (37.5%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 bidder | |
| 3 | L3₹55.0 L+₹16.5 L (42.8%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 bidder | |
| 4 | L4₹55.4 L+₹16.9 L (43.8%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 bidder | |
| 5 | L5₹56.3 L+₹17.8 L (46.1%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
11 Nov 2024, 6:00 pmClosed
GE 865 EWS
GE 865 EWS PIN-913 865 C/o 56 APO
REPAIR MAINTENANCE OF LT CABLE MCCB LT PANELS WITH CONNECTED ACCESSORIES AT SECTOR C D AND ADJACENT AREA UNDER AGE EM I OF GE 865 EWS
2024_MES_676357_2
865/EWS(NIT-76)/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 865 EWS
REPAIR MAINTENANCE OF LT CABLE MCCB LT PANELS
9 documents required · 9 mandatory
₹500
Yes
GE 865 EWS
₹80,000
Yes
23 Dec 2024
29 Oct 2024
13 Nov 2024
29 Oct 2024
11 Nov 2024
5 Nov 2024
Amount
M&L for fault finding, of PVC / XLPE Cable of any size by opening the aluminium lugs from Junction box / DB / MCCB and meggering the cable and removing the unservicable part of cable and lugs and restoring the supply as directed by Engr -in-charge. Note:- 1) The excavation, sand filling , cable protection cover, removing of surplus soil etc will be measure and paid respective items. 2) ALuminium lugs and straigt through joint will be measured and paid separetly. The rate are included for using Tools.
M&L for Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for laying UG cable in trenches on plan and n exc 1.5 m in depth in any type of soil and getting out all as specified and directed b
M&L for Excavation in trenches, n exc 1.5 m wide and exc 1.5 m and n exec 3.0 mtr depth; for foundation, of plole or laying of UG cable in trenches on plan in any type of soil and getting out of all as specified and directed
M&L for Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25m, complete all as specified & directed.
M&L for Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the strating point, complete all as specified & directed.
M&L for Sand cushioning to underground cables 8 cm below the cable before laying & 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Par-I, complete all as specified. Note : Punned thickness of 18 CM will be measured and paid for.
Supply and laying of factory made, machine pressed, unreinforced, pre-cast concrete cable cover class LV type-1 size 250 mm x 150 mm x 40mm, complete all as specified and directed
Supply and laying in replacement of XLPE insulated, armoured, haeavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 630 Sqmm 3.5 core laid in trences or passing through pipes.ducts or fixed to walls/poles completer all as specified. (Earth work, cable protection and sand cushioning shall be measured and paid for seperately). complete all as specified & directed.
All as per srl item No. 08 above but of size 500 sqmm, 3.5 core complete all as specified & directed.
All as per srl item No. 08 above but of size 240 Sqmm 3.5 core complete all as specified & directed.
All as per srl item No. 08 above but of size 185 Sqmm 3.5 core complete all as specified & directed.
All as per srl item No. 08 above but of size 150 Sqmm 3.5 core complete all as specified & directed.
All as per srl item No. 08 above but of size 120 Sqmm 3.5 core complete all as specified & directed.
All as per srl item No. 08 above but of size 95 Sqmm 3.5 core complete all as specified & directed.
All as per srl item No. 08 above but of size 70 Sqmm 3.5 core complete all as specified & directed.
All as per srl item No. 08 above but of size 50 Sqmm 3.5 core complete all as specified & directed.
All as per srl item No. 08 above but of size 35 sqmm, 3.5 core complete all as specified & directed.
All as per srl item No. 08 above but of size 25 sqmm, 3.5 core complete all as specified & directed.
All as per srl item No. 08 above but of size 16 Sqmm, 2 core all complete all as specified & directed.
All as per srl item No. 08 above but of size 10 Sqmm, 2 core all complete all as specified & directed.
Supply & fixing in replacement of tubes light grade of size 80 mm bore galvanised with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified & directed.
Supply & fixing in replacement of tubes light grade of size 50 mm bore galvanised with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified & directed.
M&L for fixing in replacement of ACSR conductor any size drawn straight horizontal on over head lines on existing poles including binding with insulators. Weight of conductor shall be measured straight horizontal distance between centre of two adjacent poles and calculating weight of conductor of size and length by adding 3% extra for sag ,jointing jumpers,etc complete all as specified & directed.
M&L for fixing in replacement of stay assembly complete with stay plate bow, stay rod of dia 16mm and gavanised iron stay wire stranded of size 7/4mm and accessories as shown in electric plate No 1 of SSR part-I (loop type insulator, stay clamps, excavation and concrete shall be measured separately) complete all as specified & directed.
M&L for fixing in replacement of shackle insulator porcelain white, brown or green 100 mm height, 65 mm dia for 1100 volts grade complete all as specified & directed.
M&L for fixing in replacement of pin insulator porcelain white, brown or green 100 mm height, 65 mm dia for 1100 volts grade complete all as specified & directed.
M&L for fixing in replacement of galvanized steel wire 4mm dia for continuous earth wire complete all as specified & directed.
Supply and fixing in replacement of bus bar chamber size 600x 450x 300 mm outdoor type made out of MS sheet 2.0 mm thick mounted on angle iron frame dully painted with two coat of synthetic enemelled paint over a coat of primer and comprising of three phase aluminum bus bar 200 amps mounted on insulators including provisioning of foundation all as specifed and directed.
All as per item No 28 above but of capacity 100 Amp complete all as specified and directed
M&L in replacement for Incoming Off load Changeover Switch Enclosure with 200 A 4 pole Incoming change Over switch- to accommodate all connected accessories complete all as specified and directed
M&L in replacement for Incoming Off load Changeover Switch Enclosure with 320 A 4 pole Incoming change Over switch- to accommodate all connected accessories complete all as specified and directed
M&L in replacement for Incoming Off load Changeover Switch Enclosure with 400 A 4 pole Incoming change Over switch- to accommodate all connected accessories complete all as specified and directed
M&L in replacement for Incoming Off load Changeover Switch Enclosure with 630 A 4 pole Incoming change Over switch- to accommodate all connected accessories complete all as specified and directed
M&L for fixing in replacement of cross arms bracing supports clamps, back plates fabricated from steel section made out of Fe-0-310/ Fe-0-410 incuding nuts,bolts and washers welding,drilling hole complete with two coats of aluminium paint over one coat of primer complete all as specified & directed.
Supply and fixing in relacement Aluminium Thimble of size 10/16/35/50/70/95 Sq mm complete all as specified and directed.
Supply and fixing in relacement Aluminium Thimble of size 120/150/185/240/300/400 Sq mm complete all as spd and directed.
M&L for painting 9 mtr steel tubular pole after scrapping and peeling of the old existing paint, corrosive patches and painting primary coat with synthetic enamelled silver paint and another final second coat to match the entire surface area of the pole and highliting the pole with 20 CM wide ulternate white and red radium strips upto height of 1Mtr from Ground level complete all as specified and directed
M&L for painting 11 mtr steel tubular pole after scrapping and peeling of the old existing paint, corrosive patches and painting primary coat with synthetic enamelled silver paint and another final second coat to match the entire surface area of the pole and highliting the pole with 20 CM wide ulternate white and red radium strips upto height of 1Mtr from Ground level complete all as specified and directed
Supply and fixing in replacement of L Frame: Adjustable Thermal* & Fixed Magnetic setting MCCB 630 Amps, 50 KA, 415 Volts four pole. Complete all as specified and directed
Supply and fixing in replacement of L Frame: Adjustable Thermal* & Fixed Magnetic setting MCCB 400 Amps, 36 KA, 415 Volts four pole. Complete all as specified and directed
Supply and fixing in replacement of L Frame: Adjustable Thermal* & Fixed Magnetic setting MCCB 250 Amps, 36 KA, 415 Volts four pole complete all as specified and directed
Supply and fixing in replacement of L Frame: Adjustable Thermal* & Fixed Magnetic setting MCCB 200 Amps, 36 KA, 415 Volts three pole complete all as specified and directed
Supply and fixing in replacement of L Frame: Adjustable Thermal* & Fixed Magnetic setting MCCB 160 Amps, 25 KA, 415 Volts three pole complete all as specified and directed
Supply and fixing in replacement of L Frame: Adjustable Thermal* & Fixed Magnetic setting MCCB 125 Amps, 25 KA, 415 Volts three pole complete all as specified and directed
Supply and errect steel tublar swaged poles in true vertical position complete with MS sheet welded on base , finial taper plug, bolts, nuts and screws as specified type 410 SP -31 (9 meters long).Including painting with two coats of synthetic enamell paint complete all as specified and directed
M&L for Cement concrete in filling and mass concrete/ foundation of poles/Stay and PCC for road crossings etc all as directed , type C-2 1:3:6 (40 mm graded aggregate) complete all as specified and directed
M&L for Cement concrete in filling and mass concrete/Coping of Poles and PCC for road crossings etc all as directed , type C-1 1:3:6 (20 mm graded aggregate) complete all as specified and directed
Replacement of Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in groud to a depth not lss than 2.25 mtrs deep below normal ground level with top edge of earth plate not less than 1,5 ntrs below normal ground level connected to galvanised iron strip 32 x 6mm as earthing leads by means of galvanised bolts, nuts, check nuts and washer of galvanised iron or steel complete with 20 mm dia GI Pipe light grade for watering and 40mm dia GI light grade pipe for protection of strip upto test point including test point of strip 50x50x3mm GI, charcoal dust, common salt 15cm all around the earth plate all as shown inelectric plate No.5 of MES SSR Part-I all as specifed or indicated and testing on competion including necessary excavation, earth work PCC pit and with RCC cover of suitable size water funnel with wire mesh all as directed by Engr-in charge.
All as per item No 48 above but using GI wire 4.0 mm dia as earthing leads by means of galvanised bolts, nuts, check nuts and washer of galvanised iron or steel complete with 20 mm dia GI Pipe light grade for watering and 40mm dia GI light grade pipe for protection of 4.0mm dia GI wire charcoal dust, common salt 15cm all around the earth plate all as shown inelectric plate No.5 of MES SSR Part-I all as specifed or indicated and testing on competion including necessary excavation, earth work PCC pit and with RCC cover of suitable size water funnel with wire mesh all as directed
M&L for Restringing/Restretching aluminium conductor/ GI wire of LT over head line three phase and neutral by opening the binding wire from insulator and tightening the all conductor and rebinding the same by binding wire with insulator as existing as directed
M&L for Restringing/Restretching aluminium conductor/ GI wire of LT over head line for Single phase and neutral with street light by opening the binding wire from insulator and tightening the all conductor and rebinding the same by binding wire with insulator as existing as directed
S&F PVC Spacer 2/4 way for LT over head line 1100 V complete all as specified and directed
M/S HONY CAPT RIGZIN SAMPHEL (BID ID -3162428)
ABID CONSTRUCTION COMPANY (BID ID -3162468)
BETONG BUILDERS (BID ID -3162437)
M/S GEE AAR and SONS ENTERPRISES (BID ID -3162447)
THINLES OTZER (BID ID -3162279)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .