Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.8 LAccepted-AOC 1ST FLOOR PRABHA SHOPPING COMPLEX OLD PAHARGAON DOLLYGUNJ PORT BLAIR SOUTH ANDAMAN ANDAMAN NICOBAR 744103 UDYAM AN 01 0000143 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L1 | Accepted-AOC Being the lowest | |
| 2 | L2₹39.9 L+₹4.0 L (11.2%)Rejected-Finance MB NO 180 MG ROAD JUNGLIGHAT PORT BLAIR 744 103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Being not the lowest | |
| 3 | L3₹41.5 L+₹5.7 L (15.8%)Rejected-Finance | L3 | Rejected-Finance Being not the lowest | |
| 4 | L4₹44.7 L+₹8.9 L (24.7%)Rejected-Finance | L4 | Rejected-Finance Being not the lowest |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
27 Nov 2021, 6:00 pmClosed
GE Minniebay
GE Minniebay, Port Blair
PROVN OF SHED, CERTAIN CIVIL WORKS AND ASSOCIATED B/R E/M WORKS NEAR P-834 FOR PARKING OF TFF L FOR EMERGENCY FIRE FIGHTING AT VAYU VIHAR, BROOKSHABAD AND ADDN/ALTN TO BLDG NO P-834 AT VAYU VIHAR, BRROSKHABAD UNDER GE MINNIEBAY, PORT BLAIR.
2021_MES_485167_1
8990/E8
Open Tender
Civil Works
Item Rate
180 days
GE Minniebay
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE Minniebay
₹90,000
Yes
28 Dec 2021
30 Oct 2021
6 Dec 2021
30 Oct 2021
27 Nov 2021
13 Nov 2021
Amount
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in hard/dense soil complete all as specified and as directed.
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in soft/loose soil complete all as specified and as directed.
Returning filling including spreading, levelling, watering and well ramming in layers n.exc 25cm complete all as specified and as directed.
Removal of excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
M&L for PCC 1:4:8, D-2 using 40mm graded stone aggregate as in filling mass concrete complete all as specified and directed
M&L for surface excavation in hard and dense soil n.exc 30 cm deep and averaging 15cm deep and getting out complete all as specified and as directed.
M&L for Moorum / Red Bajri filling in floors or pavings, laid in layers n.exc 15cm thick, spread, levelled and well rammed including watering and complete all as specified and as directed.
M&L for hardcore of guage exc 63mm but n.exc 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to make true surface complete all as specified
M&L for 10 mm dia TMT bars cut to length bent to shape required including cranking ,bending , binding with MS wire not less than 0.9 mm dia (annealed) complete all as specified and as directed.
M&L for PCC type B-1, 1:2:4 using 20mm graded stone aggregate in cover slabs with plain faces set in cement mortar 1:6 for drain, manhole & etc complete all as specified
M&L for 100 mm thick PCC 1:4:8 type D 2 using 40mm graded stone aggregate as in filling mass concrete complete all as specified and directed
S&F of heavy duty vitrified tiles, Durastone, weather proof impact resistant, abrasion resistant tiles of size 300x300x9.8mm or high dimension except thickness of any colour any design as approved.including screed bed 15mm thick 1:6, complete all as specified and as directed
M&L for pre-cast concrete with coloured finish extrnal interlocking paver block of M-35 grade , having compressive str 30 N /mm2, 60mm thick of shade as approved by GE laid dry over sand cushion of average thickness 50 mm duly consolidate,set and levelled the block in in proper level with interlocking laid in pavement complete all as specified and directed. Note : Sand filling shall be measured and paid seperately under relevent item of this schedule
M&L for 50mm thick sand filling in under floors all as specified
S&F of framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc. n.exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
S & F in repairs PTMT Graiting square /rounded 100 mm size [Minimum weight 100 Grams] without waste hole or with waste hole to insert waste pipe complete all as specified and directed.
M&L for 100mm CI pipes with spigot and socket ends entrifugally cast class LA, in any length,laid in trenches laid in 15mm thick CM 1:4 as a lean concrete complete all as specified and as directed.
S& F of steel work in tubular trusses including special shaped washers etc complete conforming to IS 1161-1979 grade St-240 complete all as specified
M& L for preparation of new surfaces of steel of any description , over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a priming coat of red oxide zinc chrome complete all as specified
S&F of Pre - painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F of Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F of aluminium flat iron work in wind ties scrow as directed incul all necessary drilling ,bolting , riviting & etc completeb all as specifed
M&L for precast cement concrete block masonry with PCC solid blocks in 1:3:6 type C1 using 20mm graded stone aggregates, exc. 10cm in width and set in CM 1:4 complete all as specified and directed.
M/L for precast cement concrete solid block masonary with solid blocks using PCC 1:3:6 type C1 using 20mm graded stone aggregate n.exc 10cm in width and setting in cement mortar 1:4 etc complete all as specified.
M&L for rendering 10mm thick on fair faces of brick/concrete surface in CM 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
S&F in repairs stainless steel sink with drainage board made out of 1.00 mm thick sheet with plug, washers, Ms angle cantilever brackets for suitable size and connecting union to pipe of overall size 1140 mm x 500 mm and bowl size 510mm x 400 mm x 190 mm all as specified complete all as specified and as directed.
M&L for demolition of Brick work or stone/ boulder masonry, built in cement mortar complete all as specified and as directed.
M & L for preparing newly plastered wall surfaces and applying two coats of oil bound distemper with 3 mm thick wall putty over a coat of primer complete all as specified and as directed
M & L for preparation of old distempered and painted surfaces of walls and applying one coat of oil bound distemper complete all as specified and as directed..
M & L for preparation of old painted wood and wood based surfaces of any description not other wise described not exceeding 10cm width or girth and applying one coat of Synthetic enamel paint complete all as specified and directed.
M & L for preparation of old painted steel surfaces of any description not other wise described over 10 cm width or girth and applying one coat of Synthetic Enamel paint complete all as specified and directed.
M&L for external rendering 5mm thick in CM 1:4 with water proofing compound (water proofing compound shall be used as per manufacturers instructions) over a coat of 10mm thick in CM 1:6 over brick or concrete surfaces finished even and fair complete all as specified and as directed. (Note : WPC shall be maeasured and paid separately under relevent item of this schedule)
Supply only water proofing compound conforming to IS-2645 1975 complete all as specified and as directed..
M& L for preparation of newly plastered surfaces and applying two coats of whether proof exterior acrylic emulsion paint with anti fungal property over a coat of primer and a coat of external wall putty complete all as specified and as directed
M&L for preparation of old plastered wall surfaces and applying one coats of acrylic emulsion based premium quality matt finish exterior antifungal paint as per manufacturer's instructions complete all as specified and as directed Note : The rates are inclusive of Scaffoldings as required
M&L for Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. .
M&L for coloured glazed ceramic tiles in vertical surfaces 350X250X7mm / 450X350X 7mm thick as in skirting /dado, set and jointed in cement slurry and pointed in coloured cement to match laid over 10mm thick cement backing coat in CM 1:3 complete all as specified and as directed.
S&F in repairs 32mm waste fittings, brass, chromium plated for glazed ware sinks and basins etc., with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end complete all as specified and as directed.
S&F in repairs aluminium anodised snap grid false ceiling of standard aluminium section such as wall angle of size 38mm x 25mm x 2.4mm weighing 0.36 Kg/Rm main/cross tees of size 36.5mm x 25mm x 1.4mm weighing 0.24 Kg/Rm, grid size n.exc. 610 x 610mm suspended with 4mm dia GI wire at interval n.exc. 600mm centre to centre for main & cross tees fixed to roof slab roof truss fixed with suitable size MS hook and fastening bolts etc including 'E' board classic 4mm thick oceanic sheet of size n.exc. 610 x 610mm size fixed in ceiling with clips to aluminium snap grid incl preparation of new surface and applying two coats of oil bound distemper over a coat of primer all as specified and directed.
Dismanteling floor or wall tiling including cement mortar bedding complete all as specified and as directed..
M&L for Virified Ceramic tiles 10 mm thick light shad (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match aid over 10mm thick cement backing coat in CM 1:4 complete all as specified and as directed.
S & F Aluminium anodised (minimum anodisation is 50 microns) Door / window / Ventilator/partition frames and shutters (02 Nos glazed & gauzed), side hung type, without sash bars, standard aluminium grills, necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, locking arrangements etc., complete with standard aluminium sections, complete all as specified and as directed by Engineer-in-charge.(Aluminium section shall be of make Jindal/Hindalco/ Indalco). (Note:- Weight of various Aluminium sections handles and locking arrangements shall only be considered for measurement for payment. However cost of rubber packing given in the item shall be deemed to be included in the rate quoted. Glass panels, prelaminated particle boards, glass & aluminium wire cloth as applicable will be measured and paid separately as supplied only).
S& F of 4 mm thick sheet figured glass and glazing with rubber packing around the glass, in squares exceeding 0.50 sqm in each pane complete all as specified and as directed.
S&F of aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40 mm complete all as specified and as directed.
Excavation post holes or similar holes, each n,ecx 0.5 Cum, getting out in hard/ dense soil, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance not exceeding 50m and making good surface complete all as specified and as directed.
M&L for PCC 1:2:4 type C2 using 40mm graded stone aggregate as in filling under post holed etc complete all as specified and directed
M & L for point wiring with 1.5 Sq.mm (nominal area) PVC unsheathed multi stranded copper conductor PVC insulated 1100 volt FRLS grade multi stranded cable drawn through and including PVC casing caping /conduit ISI marked minimum 20mm size and its accessories complete along with 1.5 Sqmm cable but in green colour as continuous earthing wire and connecting to common earth dolly completely concealed ,surface,in walls/ceiling/roofs with and including 1.2 mm thick MS sheet terminal boxes duly fabricated flush mounting in the wall for mounting switches,switch socket combinations fan regulators etc., as required with 3 mm thick plastic laminated sheet top cover all as directed and specified for the following:-
One light /fan point controlled by one 05 Amps switch
One 5 Amps plug point independent board controlled by one switch
One three pin switch socket 5 Amps plug point on same board
All as per item No 46.00 abovebut 2.5 Sqmm single core multi standard copper conductor for one three pin socket 5 Amps on independant board including continuous earth wire PVC insulated 2.5 Sqmm copper solid conductor to common earth dolly
All as per item No 46.00 above but 4 Sqmm single core multi standard copper conductor for one three pin socket 5 Amps on independant board including continuous earth wire PVC insulated 2.5 Sqmm copper solid conductor to common earth dolly
S&F of socket outlet 2/3 pin 5 Amps 240 volts flush type complete all as specified and as directed.
S&F of socket outlet 3 pin 5/15 Amps 240 volts flush type complete all as specified and as directed.
S&F of switches 6 Amps 240 volts flush type complete all as specified and as directed.
S&F of switches 15 Amps 240 volts flush type complete all as specified and as directed.
S&F of ceiling rose surface type bakelite 65 x 50 mm with three terminals with ISI mark complete all as specified and as directed.
S&F of LED tube light fitting, 1x20w, 230V, surface and wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver, flicker free, high efficiency and robust industrial batten family suitable for surface, wall and conduit mounting including all necessary connections complete all as specified and as directed
S&F of load line vertical DB TPN 4 way IP 43 IK-09 with metal double door suitable for provision of MCB , 36 KA 63 Amp complete all as directed (Note : DB shall be fixed in wall such that front cover shall be flush with the wall surface)
S&F of DB SPN 8 way with category of protection double door type IP-42 factory made with tinned copper 200 Amps rated bus bar suitable for MCBs,all as specified and directed. (Note : DB shall be fixed in wall such that front cover shall be flush with the wall surface)
S&F of MCB TPN 40 to 63 Amps, 440 Volts, 10 kA, 'C' curve complete all as specified and directed
S&F of MCB DP 32 Amps, 415 volts, 10 KA "C" curve complete all as specified and directed
S&F of MCB SP 6 to 40 Amps, 240 volts,10 KA "C" curve complete all as specified and directed
S&F of ceiling fan, 5 star rating , 1200mm sweep 240 volt , Opal white / brown colour including hanging rod minimum length 1.5 m and bush ,nut bolts and connecting etc complete all as specified and directed
S&F of exhaust fan , 300 mm sweep 240 volt, 1400rpm, Opal White / brown including making hole suitable size for fixing of exhaust fan and making good to disturbed suface adjuscent to the existing incl exhaust fan flap cover and all connections complete all as specified and as directed
S&F of wall mounted fan, 450mm sweep, 230 volts, fixing on wall with fan clamp/hook incl connections compete all as specified and as directed
S&F of step type fan regulator, 220V single phase complete all as specified and as directed
S&F of LED down light fittings 12 Watts, 240 Volts surface / recess mounted, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver, flicker free, high efficiency and robust industrial batten family incl neceessary fittings complete all as specified and as directed
S&F of LED down light fittings 18 Watts, 240 Volts surface / recess mounted, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver, flicker free, high efficiency and robust industrial batten family incl neceessary fittings complete all as specified and as directed
M&L for sub main wiring complete with 2 x 1.5 sqmm , single core multi stranded copper conductor FR PVC insulated and sheathed cable 1100 Volts grade , drawn in PVC conduit in surface/recessed on walls / roofs etc including 1x 1.0 sqmm size PVC insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site. Note : Three run of cable and one run of conduit shall be considred as one unit
All as per item No 69 above but 2 x 2.5 Sqmm and 1X 1.5 Sqmm wires complete all as specified and as directed
All as per item No 69 above but 2x4 Sqmm and 1X 2.5 Sqmm wires complete all as specified and as directed
All as per item No 69 above but 2x6 Sqmm and 1X 4 Sqmm wires complete all as specified and as directed
Taking down carefully copper/aluminum point wiring (light, Fan, Socket or power) complete, fitting such as switches ceiling roses, pendants, regulators, Sockets etc removing materials at site and making good disturbed surfaces of walls, floors roofs etc all as specified and directed
Taking down carefully copper/aluminum Sub main wiring of size 1.5/2.5/4/6/10/16/25 Sqmm from surface/concealed /existing conduit of any height removing materials at site and making good disturbed surfaces of walls, floors roofs etc all as specified and directed
M&L for earthing complete with GI earth electrode of size 60cmx60cmx6mm buried directly in ground vertically at a depth not less than 2.25 meter below normal ground level with top edge of earth plate at a depth not less than 1.5 meter below normal ground surrounded from all sides by 15 CM thick and packed layer of charcoal dust and common salt filling in alternate layers cleaned connected to and including GI earth wire 4mm size upto 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected light grade 20 mm bore for watering and including funnel wire mesh, RCC pit cover 50 mm thick and PCC chamber pit with PCC 1:3:6 type C-2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 meter) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 all as specified and directed.
S&F in replacement of load line vertical DB TPN 8 way IP 43 IK-09 with metal double door suitable for provision of MCCB , 36 KA 160 Amp complete all as directed (Note : DB shall be fixed in wall such that front cover shall be flush with the wall surface)
S&F in replacement DB SPN 8 way with category of protection double door type IP-42 factory made with tinned copper 200 Amps rated bus bar suitable for MCBs,all as specified and directed. (Note : DB shall be fixed in wall such that front cover shall be flush with the wall surface)
S&F in replacement of MCCB TPN 160 Amps, 415 V, 36KA with thimbles / lugs and nut,bolts all as required complte all as specified and as directed
S&F in replacement of MCB TP 40 to 63 Amps, 440 Volts, 10 kA, 'C' Curve complete all as specified and directed
S&F in replacement MCB DP 32 Amps, 415 volts,10 KA C series complete all as specified and as directed
S&F in replacement MCB SPN 6 to 40 Amps, 240 volts, 0 KA C series complete all as specified and as directed.
S&F in replacement LED tube light fitting, 1x20w, 230V, surface and wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver, flicker free, high efficiency and robust industrial batten family suitable for surface, wall and conduit mounting including all necessary connections complete all as specified and as directed
S & F in replacement LED light fitting, 1x33 w, 230v, 2x2 recessed mounted genaral purpose squre shaped luminaire with high transmitivity diffuser suitable for office application with profiled & flat diffuser fiited on ceiling connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified directed.
S&F in replacement of sheet metal enclosure with socket plug top, single pole and neutral enclosure with two pin earth plug and socket complete with one MCB SP of capacity 20 to 32 Amps complete all as specified and directed at site.
Supply, laying and testing of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 core complete all as specified and as directed
Supply, laying and testing of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 core complete all as specified and as directed
Supply, laying and testing of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 core complete all as specified and as directed
Supply, laying of DWC (double Wall corrugated) HDPE pipe ISI marked of outer dia of 110 mm and inner dia 95 mm polethylene including couplers, bends, cap etc., with smooth internal and profiled external surface for non pressure under ground cable complete all as secified.
Design, Supply, installing testing and commissioning factory fabricated out door type totally enclosed LT cubical panel board suitable size with busbar, conforming to relevant IS and protection class IP-65 ,dust,vermin and weather proof fabricated out of 3.15mm thick CRCA sheet duly powder coated ,mounted on 40x40x5mm MS angle iron frame,duly welded in shape and coated with two coats of synthetic enamel paint of approved colour over a coat of redoxide primer including necessary grouting of legs 300mm deep in ground in PCC 1:4:8 type D2 using 40mm graded stone aggregate ,panel base to be 500mm above ground level with suitable compartments for controls and Monitors including cable glands for incoming and outgoing cables,locking arrangement,including accomodating, supply and fixing the following accessories/items including necessary internal panel wiring with suitable size of Copper wire PVC insulated & sheathed multi stranded complete all as specified and as directed including Supply and fixing the following :-
Supply & laying GI water tubing, medium grade, 50mm bore confirming to IS-1239 [Part-1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, etc laid in tenches / floors or fixed to walls / ceiling / roof etc including testing etc complete all as specified and as directed :
Supply & laying GI water tubing, medium grade, 25mm bore confirming to IS-1239 [Part-1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, etc laid in tenches / floors or fixed to walls / ceiling / roof etc including testing etc complete all as specified and as directed :
Supply & laying GI water tubing, medium grade, 40mm bore confirming to IS-1239 [Part-1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, etc laid in tenches / floors or fixed to walls / ceiling / roof etc including testing etc complete all as specified and as directed
S&F of Gun Metal globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed of 40mm bore complete all as directed.
S&F of Gun Metal globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed of 25mm bore complete all as directed.
S&F of Ball brass valves,high pressure,with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed of 25mm bore complete all as directed.
S&F rotational moulded polyetheylene (HDPE) 2000 ltr water storage tanks, cylindrical & vertical Type, double layered,with 25mm bore tank nipple, ISI marked, hoisted and fixed in position including provision of 40mm / 25mm dia spouts for connecting inlet, outlet, over flow and washout pipes complete as directed
M&L for cutting existing GI/DI pipe line of 150/200mm bore and making connection of 50 mm bore GI pipe complete all as directed at site.
M&L for framed work such as grills,gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and as directed
S&F sluice valve 50mm bore flange type complete PN-1.6 complete all as specified and as directed
Kathir Marketing Services
V CHINNA DURAI
T.THIYAGARAJAN
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .