Tender Value
₹2.1 Cr
EMD Value
₹2.6 L
Closing Date
6 Feb 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
WORKS
14 conditions · 2 needing a document upload
IRGCC 2022 TENDER FORM SECOND SHEET & ACS 1 CLAUSE 10.2 2.Financial Eligibility Criteria: (As Per IRGCC Clause 10.2) 10.2.Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where: V= Advertised value of the tender in Crores of Rupees. N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The Tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. 10.3 Bid Capacity: The tender/technical bid will be evaluated based on bid capacity formula detailed as Annexure-VI. PLEASE READ ALL IRGCC TENDER FORM SECOND SHEET & ACS 1 CLAUSE 10.2 TO EVALUATE THE FINANCIAL ELIGIBILITY CRITERIA
IRGCC 2022 TENDER FORM SECOND SHEET & ACS 1 CLAUSE 10.1 1.Technical Eligibility Criteria: (As Per IRGCC Clause 10.1) (a)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: 1Three similar works each costing not less than the amount equal to 30% of advertised value of the tender OR 2Two similar works each costing not less than the amount equal to 40% of advertised value of the tender OR 3One similar work costing not less than the amount equal to 60% of advertised value of the tender Note for Item 10.1: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate. PLEASE READ ALL IRGCC TENDER FORM SECOND SHEET & ACS 1 CLAUSE 10.1 TO EVALAUTE THE TECHNICAL ELIGIBILITY CRITERIA
Defination of Similar Work :- Any work of EI / PI / RRI / ABS/ IBH/ LC Gate interlocking work which include indoorand outdoor signalling work.
8 conditions · 1 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Complete tender document including NIT details, schedule, conditions is attached herewith. Tenderers are requested to read the tender document thoroughly before quoting their rates.
Tender will be governed as per latest standard Indian Railways General Conditions of Contract, works 2022 and their all correction slips. Tenderer are requested to read the latest IR GCC works 2022 and their all correction slips before submission of their offer and must be submit the all Annexures, documentary evidences, data as mentioned in IRGCC Works 2022 and their all correction slips.
All the documents in support of the Minimum Eligibility Criteria including Letter of Acceptance/Work Order, Documents showing the nature and total value of work, Completion report, Audited balance sheet, Attested certificate from Government employer, Copy of I.T. return etc. should be submitted along with the bid. Railway reserves the right to make or not to make any further reference to the tenderer regarding the fulfillment of the Minimum Eligibility Criteria and to award the tender only on the basis of the documents submitted by the tenderer along with the bid. The tenderer will not have any claim on this account.
Rights of the Railway to deal with Tender: The authority for the acceptance of the tender will rest with the Railway. It shall not be obligatory on the said authority to accept the lowest tender or any other tender, and tenderer(s) shall neither demand any explanation for the cause of rejection of his/ their tender nor the Railway to assign reasons for declining to consider or reject any particular tender or tenders. If the tenderer(s) deliberately gives / give wrong information in his / their tender or creates / create circumstances for the acceptance of his / their tender, the Railway reserves the right to reject such tender at any stage.
If the bidder submits Bid security in the form of Bank Guarantee "The original Bank Guarantee should be delivered in person receive and dispatch section of this office (i.e. DRM office, Engineering Branch, West Central Railway, Jabalpur) before closing date for submission of bids (i.e. excluding the last date of submission of bids)
IMPORTANT NOTES WITH NIT: 1.As per Railway Boards letter no. 94/CE-I/4 Pt.17 dated: 13.08.2012, for all work contract valuing more than Rs.10 Crore, "two Packet System" of tendering mandatorily be followed. 2.As per Railway Boards letter no. 2002/CE-I/CT/37 JV Pt.VIII dated: 14.12.2012, "JOINT VENTURE FIRMS" shall now be applicable to the works tenders of value More than Rs. 10 Crores. 3.This is highly technical work to be executed only by qualifying MEC stipulated in tender document as per IR GCC 2022 with similar work issued vide CSTE office letter no. WCR/N-HQ/150/Wks/Policy/14 dated: 03.08.2018. No any relaxation in MEC will be given for any consideration. Firm failing to satisfy the MEC will be treated as ineligible firm. (IF MEC APPLICABLE) 4.In terms of railway board's letter no. 2020/CE-I/CT/3E/GCC/Policy dated: 30.12.2020, If the bidder is banned for submission of bids on the date of closing of tender, such bid, even if received, shall be treated as invalid while evaluating the bids. 5.Change of inspection authority may be done by engineer-incharge at a later date. 6.In case of more than one valid & eligible L-1 bidders, tender may be awarded to tenderer having higher bid capacity. In case bid capacity is also the same, tenderer having done more value of similar work in last three previous financial years and current financial years up to the date of the opening of the tender, may be selected for the award. Instructions with respect to bid capacity will follow. Supporting document for this may be clearly uploaded by tenderer with their offer. 7.West Central Railway Joint procedure order for undertaking earth work in the vicinity of electrical, signalling, telecom cables issued vide no. WCR/N-HQ/110/JPO Corrsp/Sig.-99 dated: 08.01.2024 instructed vide GM (S&T) JBP letter no. JBP/N.H.Q.120/Policy/T-1/Part-V dated: 10.01.2024 and procedure for undertaking digging work in the vicinity of signalling, electrical and telecommunication cables issued by railway board vid eno.2021/Tele/5(2)/3-Part(1)(3425647) dated 12.06.2023 or any other latest JPO by railways will be applicable in this contract. 8.It is responsibility of the contractor during execution the work near the track, that all safety precautions will be taken like; Safety Jacket, wearing of Safety Shoes and Helmet to avoid any type of causality. 9.The provisions contained in railways circulars, JPO's regarding penalties will be applicable for works requiring digging. 10.As per railway boards letter no. 2017/CE-I/CT/9 dated: 31.05.2023 "for all contracts costing more than Rs.5 crore, Contractor's e-MB is mandatory and contractor's e-MB should be part of Tender Document. All other provisions of railway boards letter no. 2017/CE-I/CT/9 dated: 31.05.2023 will be followed. (If applicable)
S&T Work in connection with provision of two additional loading line, new shunting neck, double exit & development of Container Rail Terminal (CRT) at Kaima station of Jabalpur division on West Central Railway.
JBP-N-SIG-TENDER-2026-4~WCR
JBP-N-SIG-TENDER-2026-4
Open
Works - General
11 Months
Jabalpur, Madhya Pradesh
₹0
₹2.6 L
6 Feb 2026
15 Jan 2026
23 Jan 2026
203 items across 3 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 36,82,234.27 | ||
| — | 15.00 | — | — | ||
| Supply of Phenolic Laminated sheet, resin bonded 10mm thick, grade P3 in standard size of 1.22 x 1.22 Mtr. as per spec. No IS 2036 of 1974. INSPECTION BY CONSIGNEE. | — | — | — | 59,367.15 | |
| — | 150.00 | — | — | ||
| Supply of cartridge fuse block made of PBT as per RDSO Drg. Nos. SA - 23748 Alt. 4 and Spec. Nos. IRS-S-75/2006 with latest amendment. Fuse block shall be suitable for round head type fuses. INSPECTION BY RDSO. | — | — | — | 27,066 | |
| — | 150.00 | — | — | ||
| Supply of non decorating type low voltage cartridge fuse current 2Amp/4Amp in equal proportion round head type a s p e r spec No IRS/S/78/92 with latest amendment. INSPECTION BY RDSO. | — | — | — | 11,716.5 | |
| — | 15.00 | — | — | ||
| Supply of Earth Electrode assembly as per Drg. No. S&T/CON/KOTA/Earthing/01. INSPECTION BY CONSIGNEE. | — | — | — | 13,924.95 | |
| — | 1200.00 | — | — | ||
| Supply of two in two out (4 conductor) Knife edge disconnect terminal block set as per RDSO/SPN/189/2004 ver 3.0 with latest amendment. INSPECTION BY CONSIGNEE. | — | — | — | 97,116 | |
| — | 120.00 | — | — | ||
| Supply of end plate suitable for disconnect terminal. INSPECTION BY CONSIGNEE. | — | — | — | 1,449.6 | |
| — | 60.00 | — | — | ||
| Supply of steel carrier Din rail suitable for fixing disconnect terminal 1 meter long of dimension 35mm X 7.5 mm, 1mm thickness, unslotted. INSPECTION BY CONSIGNEE. | — | — | — | 8,605.2 | |
| — | 240.00 | — | — | ||
| Supply of end stop suitable for disconnect terminal block. INSPECTION BY CONSIGNEE | — | — | — | 2,536.8 | |
| — | 5.00 | — | — | ||
| Supply of PVC insulated flexible wire 16/0.2 mm Dia with latest amendments of various colours. (Red, black & grey) with OEM guaranty/ warranty certificate INSPECTION BY CONSIGNEE. | — | — | — | 31,473.4 | |
| — | 500.00 | — | — | ||
| Supply of ARA Terminal Blocks with links made of PBT spec. No. IRS75/2006 (Rev.2) with latest amendments and RDSO Drg. No. SA-23741A. INSPECTION BY RDSO. | — | — | — | 33,790 | |
| — | 300.00 | — | — | ||
| Supply of DWC pipe 120 mm outer dia 103.5 mm inner dia made of polyethylene in 6 mtrs. straight lengths along with one coupler for every 6 mtr.as per specn. Is14930 or latest anti rodent and flame retardant or as per site requirement. INSPECTION BY CONSIGNEE. | — | — | — | 88,791 | |
| — | 46.00 | — | — | ||
| Supply of low maintenance Lead Acid Secondary Cells 2V/ 80 Amp Hr. as per spec IRS S88/2004 ver 1.0 with latest amendments. INSPECTION BY RDSO. | — | — | — | 91,595.2 | |
| — | 300.00 | — | — | ||
| Supply of GI pipe, inner dia. 100mm dia. B-class as per spec. No.IS 1239PT. 1/2004 with sockets and fittings. INSPECTION BY CONSIGNEE. | — | — | — | 3,61,107 | |
| — | 10.00 | — | — | ||
| Supply of Thermo Shrinkable Jointing Kit (TS4) as per spec.no. IRS TC.77/2012 (Rev3.0) amdt 3 or latest for joints for 6 Quad cable of 0.9 mm dia conductor jelley filled UG cable from RDSO approved firms. INSPECTION BY RDSO. | — | — | — | 31,992.3 | |
| — | 8.00 | — | — | ||
| Supply of QSPA1, 24VDC, Slow to pick up 8F/4B, along with plug board (Base plate) retaining clip and connectors confirming to BRS: 933A, IRS:S60 & IRS:S34 INSPECTION BY RDSO. | — | — | — | 41,024.32 | |
| — | 9.00 | — | — | ||
| Supply of Shunt Signal Post with Base (GI Pipe of 80 mm Dia. Medium class IS Specification IS:1239 Pt-1/1990). INSPECTION BY CONSIGNEE. | — | — | — | 22,356 | |
| — | 9.00 | — | — | ||
| Supply of Track Relay QTA2 (AC immunised relay), 9 Ohm,2F/1B or 4F/2B, along with plug board (Base plate), retaining clips and connectors conforming to BRS:939A, IRS:S34 &IRS:S23. INSPECTION BY RDSO. | — | — | — | 49,513.77 | |
| — | 12.00 | — | — | ||
| Supply of relay universal LEDECR, QECX 61 4F/4B INSPECTION BY RDSO. | — | — | — | 7,23,265.44 | |
| — | 1.00 | — | — | ||
| Supply of cable avoider tool for detecting and route tracing of buried cable, Make- Model-RD-8200G of Radio detection Ltd or similar, HSNcode-9030800. INSPECTION BY CONSIGNEE. | — | — | — | 4,89,094.6 | |
| — | 11.00 | — | — | ||
| Supply of Track feed battery chargers of 10A rating to spec. nos. IRS S89/2013 ver 1.0 with latest amendment. Charger shall be suitable for charging 80 AH battery. INSPECTION BY RDSO. | — | — | — | 23,150.16 | |
| — | 31.00 | — | — | ||
| Supply of track lead junction boxes as per Drg. Nos. RST11509 made from fiber glass along with terminal blocks. The TLJB should be BLACK in colour. INSPECTION BY CONSIGNEE. | — | — | — | 27,297.36 | |
| — | 11.00 | — | — | ||
| Supply of B type choke to specn.Nos.IRS.S.65/83 with latest amendments. INSPECTION BY RDSO. | — | — | — | 36,611.96 | |
| — | 11.00 | — | — | ||
| Supply of adjustable Track Feed Resistance, 30 ohms as per RDSO Drg. Nos. SA- 20161-66M/M with latest amendments (with Phenolic moulded base). INSPECTION BY RDSO. | — | — | — | 11,896.72 | |
| — | 1000.00 | — | — | ||
| Supply of PVC jacketed wire rope for Track Lead connections. PVC jacketed wire rope should be of Galvanised steel wire rope 6 mm dia (6x19 stranded wire with steel core of 6 mm dia) sheathed with PVC 2mm wall thickness, overall thickness being 10 mm. PVC sheath should be made of type 6 compound as per IS 5831 of 1970. Reclaimed or recycled material should not be used. INSPECTION BY CONSIGNEE. | — | — | — | 57,980 | |
| — | 3.00 | — | — | ||
| Supply of portable handheld communication system used for secure peer to peer communication. The device must be equipped latest technology standard as per specification. INSPECTION BY CONSIGNEE. | — | — | — | 56,398.8 | |
| — | 120.00 | — | — | ||
| Supply of Sealed Maintenance free VRLA Battery set of 60 cells (Stackable), in combination of 55+5 cells for SMPS based integrated power supply system, each cell of 2V/300AH capacity, fully charged, confirming to RDSO Specn.no.:IRS:S:93/96(A) with latest amendment. INSPECTION BY RDSO | — | — | — | 5,92,402.8 | |
| — | 5.00 | — | — | ||
| Supply of Electric Point Machine (Rotary locking Type) , 110VDC operation(AC immunity 160V) asper RDSO drg. S-11000with ground connection and clamp lock arrangement suitable or220mm throw for thick web switches as per IRS S24/2025 Rev 3 with amendment 1 or latest. INSPECTION BY RDSO | — | — | — | 5,14,561.45 | |
| — | 4.00 | — | — | ||
| Supply of Relay AC Immune, Plug in type, Style QBCA-1, DC Biased Point Contactor,24V DC, 2F DC, 2HF-4B Contacts (Front Contacts Heavy Duty and Back Contacts Metal to Carbon) Complete with Plug Board, Retaining Clips and Connectors, Conforming to BRS 943, IRS:S-34 andIRS:S-23. (INSPECTION BY RDSO | — | — | — | 27,222 | |
| — | 1.00 | — | — | ||
| Supply of Signal Nos. plates. as per Drg enclosed. INSPECTION BY CONSIGNEE | — | — | — | 494.6 | |
| — | 1.00 | — | — | ||
| Supply of Hand cuff Locks/ Godrej Navtal lock with common key INSPECTION BY CONSIGNEE | — | — | — | 270 | |
| — | 1.00 | — | — | ||
| Supply of position light shunt signal Unit. as per RDSO Nos. SA23840. INSPECTION BY CONSIGNEE | — | — | — | 7,965.71 | |
| — | 1.00 | — | — | ||
| Supply of Offset Bracket 3-1/2" for shunt signal. INSPECTION BY CONSIGNEE | — | — | — | 503 | |
| — | 5.00 | — | — | ||
| Supply of lamp holders and switches, two pin (Bakelite type) for location boxes (Anchor make or equivalent) INSPECTION BY CONSIGNEE | — | — | — | 471.45 | |
| — | 2.00 | — | — | ||
| Supply of Hydrometer, Exide make or similar for measuring specific gravity of Battery Graded acid with mounting stand in location Boxes. Consignee inspection under manufacturer certificate. INSPECTION BY CONSIGNEE | — | — | — | 524.2 | |
| — | 1.00 | — | — | ||
| Supply of "S" shape GI bend pipe Medium class, 50 mm dia. and of 1 mtr length, for cable entry in point machines as per spec. IS:1239 (Pt.I) - 2004 or latest INSPECTION BY CONSIGNEE | — | — | — | 288.53 | |
| — | 1.00 | — | — | ||
| Supply of Ground connections, complete set suitable for IRS Make point Machine for ordinary turnout with tongue attachment insulation as per RDSO Drg. Nos. RDSO/S 3361-62 with latest amendment. This includes supply of Acetyl bushes as per site requirement.(Ground connections for 52 Kgs. Rails as per RDSO drg. Nos. S-3362) INSPECTION BY CONSIGNEE | — | — | — | 8,730.3 | |
| — | 1.00 | — | — | ||
| Supply of William stretcher nylon insulation set suitable for ground connections per RDSO drg Nos T-10367, T-10368, T-10384 as applicable and to the spec IRS S 23 & 40/84 with latest amendment. INSPECTION BY CONSIGNEE | — | — | — | 641.05 | |
| — | 1.00 | — | — | ||
| Supply Gauge Tie plate nylon insulation as per RDSO drg Nos: T- 10372Alt2, T-10368, T- 10371Alt2, T-15083/88/Alt2 & T-11690/Alt2 and to the spec IRS S 23 & 40 with latest amendments as applicable. INSPECTION BY CONSIGNEE | — | — | — | 311.37 | |
| — | 1.00 | — | — | ||
| Supply of pre wired crank handle cum key lock relay box along with LEDs, Push buttons, 8-way terminals strips, string rods, etc. INSPECTION BY CONSIGNEE | — | — | — | 11,107.82 | |
| — | 1.00 | — | — | ||
| SSupply of Electric Point Machine (Rotary locking Type) 110 V DC operations. (AC Immunity 160V) NONTRAILABLE, complete with Lock Detector, cable termination box and slides for lock and detector. As per RDSO specification No. IRS S/24/2025 Rev 3.0 or latest. Requirement of point machine is 143 mm throw only as per RDSO Drg. No. RDSO/S-10800. INSPECTION BY RDSO | — | — | — | 1,17,619.76 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TD-4-KMSSHNeckCRT.pdf
ATTACHMENT
GCC-April2022-1111.pdf
ATTACHMENT
GCCACS1TO10.pdf
ATTACHMENT
JPO10-1-2412-6-23.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .