Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.4 LAccepted-AOC RABINDRA NAGAR P O RABINDRA SARANI SILIGURI 734 006 DIST DARJEELING W B | JALPAIGURI | WEST BENGAL | 734006 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹29.9 L+₹13,402 (0.45%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹30.1 L+₹28,942 (0.97%)Rejected-Finance 9 SARAT BOSE ROAD OPP KALIDHAR TRANSFORMER HAKIMPARA SILIGURI 734 001 | DARJEELING | WEST BENGAL | 734001 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹30.1 L+₹33,608 (1.13%)Rejected-Finance SWAMIJI SARANI HAKIMPARA P O SILIGURI 734001 DIST DARJEELING WB | JALPAIGURI | WEST BENGAL | 734001 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹30.1 L+₹37,682.50 (1.27%)Rejected-Finance OPPOSITE GHOOM DRC PO GHOOM DISTT DARJEELING WB PIN 734 102 | DARJEELING | WEST BENGAL | 734102 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
5 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer sukna
Garrison Engineer sukna, Post-Simulbari, Dist.-Darjeeling, WB-734009
OUTSOURCING OF SERVICES FOR ELECTRIC SUPPLY INSTALLATIONS AND OTHER MISC EM WORKS AT U AREA UNDER AGE EM OF GE SUKNA
2020_MES_362301_2
GE Sukna/8153
Open Tender
Civil Works
Item Rate
330 days
Sukna
AS PER NIT
7 documents required · 7 mandatory
₹500
GE Sukna
₹60,000
Yes
29 Sept 2020
21 Aug 2020
8 Sept 2020
21 Aug 2020
5 Sept 2020
23 Aug 2020
60 days
Amount
Out sourcing of services for operation and maintenance of "U Area Power House 11/.433KV'' having the following electrical equipments / machineries, round the clock in 03 shifts of 8 hours each and including sundays and holidays complete all as specified and directed by Engineer-in-Charge:- Manpower:- One electrician (semi skilled operator) & One helper (un skilled) per shift Timings:- 1st shift - 0600 Hrs to 1400 Hrs 2nd shift - 1400 Hrs to 2200 Hrs 3rd shift - 2200 Hrs to 0600 Hrs (Contd...)
Electrical equipments / machineries:- i) Transformer outdoor step down type 11/0.433KV, 630 KVA - 04 Nos ii) Transformer outdoor step down type 420 KVA - 01 No iii) Transformer outdoor step down type 11/0.433KV, 63 KVA - 01 No iv) Transformer 11/.433KV, 25 KVA - 01 No v) HT four pole structure - 10 Nos vi) HT two pole structure - 07 Nos vii) APFC Panel - 02 Nos viii) LT Distribution Panel with control switch - 27 Nos ix) LT/HT UG Cable - 7300 RM Notes:- The quoted rate is deemed to be included of following :- (i) Daily maintenance and including greasing, lubrications, minor repairs, emergency fault rectification etc, with necessary T&P. (ii) Cleaning of entire installation and surrounding area shall be carried out daily and sanitation system shall be cleaned and kept hygienic. (iii) Approval of Engr-in-Charge shall be taken before employing manpower.
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out all excavated material in soft / loose soil complete all as specified and directed.
Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing of excavated surplus soil to a distance n. exc 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
M&L sand cushioning with clean and dry sand in trenches for protection of UG cable and including punning down complete all as specified and directed. Note:- Punned thickness shall only be measured and paid.
Supply & laying sub class 'B' bricks of old size, laid along alignment of cable as protection to cable in trenches complete all as specified and directed.
Supply & laying LT XLPE insulated, armoured heavy duty electric cable with alumimium conductor, 1100 volts grade, cross sectional area 35 Sqmm x 3.5 Core, laid in trenches / duct / on pole complete all as specified and directed. Make :- Havells / KEI / Polycab / Finolex / Gloster cables Ltd / Asian Cable / RR Kabel Ltd.
All as per Sl. Item No. 8 above but 16 sqmm x 4 Core
S&F cubical type LT panel board, outdoor type, factory made from CPRI approved factory, having overall minimum dimensions 1.20 m (L) X 1.20 m (H) X 0.70 m (W), made out of 3.00 mm thick CRCA steel sheet and including MS angle iron 50 x 50 x 6 mm frame work, legs 0.6 m long, totally enclosed, dust & vermin proof using neoprene rubber gasket (IP-54), double leaf door shutter in front side and single leaf shutter in rear side fixed with hinges having necessary locking arrangement in both front and rear door, with four side projected slanting roof, duly powder coated of approved shade over a coat of red oxide primer both internally and externally and including mounting on PCC platform made out of PCC 1:3:6, 150 mm thick (100 mm below & 50 mm above GL) all round the panel board and including necessary earth work. The panel board shall be suitable for operation on AC 415 Volt, 3 Phase, 50 Hz, 4 wire system and shall have aluminium bus bar of 400 Amps capacity with colour insulating tape / sleeves mounted on porcelain or synthetic insulators, provision for fixing MCCBs / MCBs, necessary inter-connections with bus bar / strip with colour code insulation, LED indicating lamps (R, Y, B), provision of cable entry / exit provided in bottom, connections of all outgoing / incoming, existing / new cables of required size with following accessories and including taking down complete all as specified and directed:- (Contd...)
Incoming :- (i) MCCB 4 pole 400 Amp, 50KA, Ics = 100% Icu - 1 No. Outgoing :- (i) MCCB 4 pole 160 Amp, 25KA, Ics = 100% Icu - 2 Nos. (ii) MCCB 4 pole 100 Amp, 25KA, Ics = 100% Icu - 1 No. (iii) Voltmeter 0 to 500 V, digital type (iv) Ammeter 0 to 400 Amp, digital type (v) Onload Change over switch, 4 pole 400 Amps, 50 Hz 415 V - 01 No with 02 Nos incoming and multi outgoiing Make of MCCB :- Legrand / L & T / Siemens / ABB Make of voltmeter / ammeter :- Havells India Ltd. / HPL India Ltd. / L&T / Schneider / BCH Make of CT/PT:- AE / English Electric / Crompton Greaves / Areva T&D / Schneider Make of Change Over Switch:- L&T / Legrand / ABB / Siemens / C&S Electric Ltd. / Schnieder / Havells India Ltd.
S&F cubical type LT panel board, outdoor type, factory made from CPRI approved factory, having overall minimum dimensions 1.00 m (L) X 1.20 m (H) X 0.70 m (W), made out of 3.00 mm thick CRCA steel sheet and including MS angle iron 50 x 50 x 6 mm frame work, legs 0.6 m long, totally enclosed, dust & vermin proof using neoprene rubber gasket (IP-54), double leaf door shutter in front side and single leaf shutter in rear side fixed with hinges having necessary locking arrangement in both front and rear door, with four side projected slanting roof, duly powder coated of approved shade over a coat of red oxide primer both internally and externally and including mounting on PCC platform made out of PCC 1:3:6, 150 mm thick (100 mm below & 50 mm above GL) all round the panel board and including necessary earth work. The panel board shall be suitable for operation on AC 415 Volt, 3 Phase, 50 Hz, 4 wire system and shall have aluminium bus bar of 300 Amps capacity with colour insulating tape / sleeves mounted on porcelain or synthetic insulators, provision for fixing MCCBs / MCBs, necessary inter-connections with bus bar / strip with colour code insulation, LED indicating lamps (R, Y, B), provision of cable entry / exit provided in bottom, connections of all outgoing / incoming, existing / new cables of required size with following accessories and including taking down complete all as specified and directed:- (Contd...)
Incoming :- (i) MCCB 4 pole 250 Amp, 50KA, Ics = 100% Icu - 1 No. Outgoing :- (i) MCCB 4 pole 63 Amp, 25KA, Ics = 100% Icu - 1 No. (ii) MCCB 4 pole 100 Amp, 25KA, Ics = 100% Icu - 2 Nos. (iii) Voltmeter 0 to 500 V, digital type (iv) Ammeter 0 to 300 Amp, digital type Make of MCCB :- Legrand / L & T / Siemens / ABB Make of voltmeter / ammeter :- Havells India Ltd. / HPL India Ltd. / L&T / Schneider / BCH Make of CT/PT:- AE / English Electric / Crompton Greaves / Areva T&D / Schneider
M&L lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for 11000 volts including taking down complete all as specified and directed. Make:- Oblum / Elpro / BHEL / Areva T&D / Jaipuria Brothers
S&F cable junction box of size not less than 167 mm (w) x 125 mm (h) x 82 mm (d) with terminals, IP 65, with cover and metric knockout for cable entry suitable for 10 sqmm cable, fixing arrangement with MS flat of size 40 x 4 mm, necessary nuts, bolt and washers including taking down complete all as specified and directed. Make:- Hensel Cat No. K9105 or equivalent in Sintex Industries Ltd. / C&S electric Ltd.
Dismantling of overhead aluminium conductor, steel reinforced (ACSR) or AAC conductors complete all as specified and directed.
Dismantling insulators from poles of any type & any size complete all as specified and directed.
Dismantling cross-arms of MS channel or angle sections etc, complete all as specified and directed.
M&L straight through joint heat shrinkable type complete with jointing materials and accessories, suitable for 1.1 KV, 3.5 / 4 core XLPE aluminium conductor cable of size 10 to 16 Sqmm complete all as specified and directed. Make:- 3M / Denson / Raychem
All as per Sl. Item No. 19 above but for cable of size 25 to 50 Sqmm
Boring holes horizontally under road, manually, in soft / loose soil, without cutting / disturbing the existing road surface, suitable for inserting pipe of n exc. 80 mm bore at a depth 0.75 m to 1.0 m from road surface for passing of UG cable, getting out and disposal of soil to a distance not exceeding 50 m complete all as specified and as directed. Note:- GI Pipe shall be measured and paid separately.
S&F 80 mm bore galvanised steel water tubing, medium grade with necessary fittings, laid under road crossing or fixed along electric pole etc, for cable protection complete all as specified and directed. Make - Tata / Jindal Steel / Prakash
S&F PVC insulated 3 core multistranded sheathed cable with 2.5 Sqmm copper conductor for connection of street / security light etc, including taking down complete all as specified and directed. Make:- Havells / Finolex / KEI / Polycab / RR Kabel Ltd.
M&L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to earth lead of galvanised iron strip 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, all as shown in electrical plate No. 3 connected to earthing test point including dismantling complete all as specified and directed. Note:- The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, RCC 1:1.5:3, type A1 cover slab, 50 mm thick reinforced with 8 mm dia TMT bar @ 140 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, 20 mm bore medium grade GI watering pipe, 40 mm bore GI light grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.
GEETA CONSTRUCTION
ASHOK MUKHERJEE
S D CONSTRUCTION CO
Damdoo Bhutia
MS ORIENT ENGINEERING WORKS
SURESH JHA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .