Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹28.8 LAccepted-AOC H NO 177 GOVINDPURA SATWARI JAMMU CANTT 180003 J K | JAMMU | JAMMU AND KASHMIR | 180003 | L-1 | Accepted-AOC Lowest Bidder | |
| 2 | L-2₹29.3 L+₹35,687.72 (1.23%)Rejected-Finance | L-2 | Rejected-Finance Other than lowest bidder | |
| 3 | L-3₹31.6 L+₹2.7 L (9.31%)Rejected-Finance | L-3 | Rejected-Finance Other than lowest bidder | |
| 4 | L-4₹34.7 L+₹5.8 L (19.9%)Rejected-Finance | L-4 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹74,000
Closing Date
7 Oct 2022, 6:00 pmClosed
GE Jammu
GE Jammu c/o 56 APO Pin-900277
SPECIAL REPAIR OF SEWAGE LINE AT RANJIT LINES INCLUDING CERTAIN MINOR WORKS AND REVENUE WORKS IN MIRAN SAHIB UNDER GE JAMMU
2022_MES_551233_1
GEJC-47/2022-23
Open Tender
Civil Works
Item Rate
200 days
AoR of GE Jammu
Please refer Tender Documents
9 documents required · 9 mandatory
₹500
GE Jammu
₹74,000
Yes
21 Oct 2022
10 Sept 2022
10 Oct 2022
10 Sept 2022
7 Oct 2022
24 Sept 2022
Amount
B/R Portion: - Excavation in trenches not exceeding 1.5m wide, not exceeding 1.5m in depth, for foundation, etc, or for shafts, wells, cesspits, manholes, pier holes, etc not exceeding 10 Sqm on plan and not exceeding 1.5m in depth and getting out in any type of soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5m but not exceeding 3.0 m deep and getting out in hard / dense soil complete all as specified and directed.
Demolition / breaking of drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar and taking out off trenches and removing the debris from the site all as specified of 150mm / 200 mm dia pipe including demolition of cement concrete haunching etc complete all as specified and directed.
Material and Labour for concrete bed to 150 mm bore pipe (1:4:8) in type D-2 (using 40mm graded crushed stone aggregate) including haunching against the sides of pipe complete all as specified and directed.
Supply and fixing and laying 150 mm thick reinforced concrete pipes class NP-2 laid and jointed complete with collars as in trenches complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removal of surplus excavated soil to a distance exceeding 250 m and not exceeding 500m and deposited where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Cleaning of septic tanks / manhole of any capacity by removing sludge and sludge water by pumping machine operated with vacuum pressure to suck the sludge and containing in itself and the sludge / sludge water is to be disposed off to a distance of 2 KMs outside the peripherry of defence land including taking off and refixing manholes covers complete all as specified and directed.
Demolition of cement concrete in ground floor and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
Material and Labour cement concrete (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) in foundation, filling and mass concrete complete all as specified and directed.
Material and Labour for cement concrete (1:3:6) type C-1 (using 20 mm graded crushed stone aggregate) as in surface channel and drains including necessary form work etc complete all as specified and directed.
Material and Labour cement concrete in benching (similar to surface channel) with concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) complete all as specified and directed.
Material and Labour extra for forming fair finished drain or channel 30 cm inner girth in cement concrete including moulds, mitred / stopped end etc complete all as specified and directed.
Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, drains etc, but excluding ashlars facings, dressed stone work and precast concrete articles complete all as specified and directed.
Material and Labour brick work with fly ash bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:6) complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key and scrubbing down with water complete all as specified and directed.
Material and Labour rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4), finished even and smooth without using extra cement mixed with water proofing compound up to four storey building complete all as specified and as directed. Note: - Water proofing compound shall be measured and paid separately.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Material and Labour providing precast cement concrete in cover slab (for manhole) or in window, door cill, lintels, with plain fair faces, including chamfered, weathering, throating etc (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) set in CM (1:4) complete all as specified and directed.
Material and Labour mild steel TMT bars 10 mm dia and over cut to length, bend to shape etc complete binding with and including mild steel annealed wire not less than 0.09 mm dia conforming TMT bars complete all as specified and directed.
Material and Labour mild steel work as in framed work as in frame for septic tank / manhole cover complete all as specified and directed.
Material and Labour cement concrete (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in coping of manholes complete all as specified and directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or 3/4 section) in cement concrete (1:2:4) type B-1 smooth finished and reforming benching as required of 2000mm dia pipe complete all as specified and directed.
Material and Labour for construction of soakage well 3.60 M dia and 3 M (Effective depth) deep excavation in any type of soil foundation in PCC (1:3:6) walls of honey combed brick work with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick work in CM RCC cover slab M-25 / SFRC cover interconnecting pipes of RCC / DEC complete filled with brick bats all as shown on drawing no. CEPZ/C-TD-013-13 complete all as specified and directed.
Material and Labour for construction of soakage well 1.80 M dia and 3 M (Effective depth) deep excavation in any type of soil foundation in PCC (1:3:6) walls of honey combed brick work with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick work in CM RCC cover slab M-25 / SFRC cover interconnecting pipes of RCC / DEC complete filled with brick bats as shown on drawing no. CEPZ/C-TD-013-13 complete all as specified and directed.
Material and Labour for construction of septic tank for 100 users capacity including excavation and earth work in ordinary soil, foundation with PCC (1:2:4) type B-1, brickwork in CM (1:4), RCC (1:2:4) type B-1 slab, RCC precast manhole cover having 6mm plate embedded around with angle iron frame, vent shaft and sludge chambers etc all as shown on drawing no. CEPZ/C-TD-013-13 complete all as specified and directed. Note: - Rate quoted includes final depth of invert level of septic tank on the basis of longitudinal slope of sewage line.
Material and Labour for construction of septic tank for 25 users capacity including excavation and earth work in ordinary soil, foundation with PCC (1:2:4), type B-1, brickwork in CM (1:4), RCC (1:2:4) type B-1 slab, RCC precast manhole cover having 6mm plate embedded around with angle iron frame, vent shaft and sludge chambers etc all as shown on drawing no. CEPZ/C-TD-013-13 complete all as specified and directed. Note: - Rate quoted includes final depth of invert level of septic tank on the basis of longitudinal slope of sewage line.
Taking up or down CI / PVC pipes (including all fittings), with spigot and socket ends and lead joints including burning out joints and removing lead of 100 / 75 mm dia pipe complete all as specified and directed.
Supply and fixing cast iron soil, waste and vent pipe of bore 100mm in any length with or without ears with cement joints fixed to wall complete all as specified and directed.
Supply and fixing cast iron soil, waste and vent pipe of bore 75mm in any length with or without ears with cement joints fixed to wall complete all as specified and directed.
Supply and fixing cast iron soil, waste and vent pipe of bore 100mm in any length with or without ears with cement joints laid in floors complete all as specified and directed.
Supply and fixing cast iron soil, waste and vent pipe of bore 75mm in any length with or without ears with cement joints laid in floors complete all as specified and directed.
Supply and fixing in repair 75 mm bore cast iron bends (any radius) with oval access doors complete all as specified and directed.
Supply and fixing in repair 100 mm bore cast iron bends (any radius) complete all as specified and directed.
Supply and fixing in repair 75 mm bore CI branch pieces (Tee), single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches with oval access complete all as specified and directed.
Supply and fixing in repair cast iron vent cowl 75 mm complete all as specified and directed.
Supply and fixing in repair stack clamps out of 50mm x 5mm flat iron and 16mm dia round iron stays including bolts and nuts and securing ends of stay to walls or roof for 75 mm bore pipe complete all as specified and directed.
Supply and fixing in repair stack clamps out of 50mm x 5mm flat iron and 16mm dia round iron stays including bolts and nuts and securing ends of stay to walls or roof for 100mm bore pipe complete all as specified and directed.
Supply and fixing 75 / 100 mm cast iron floor trap with stainless steel grating including jointing to waste pipe fixed in cement concerete (1:2:4) type B-1 complete all as specified and directed.
Supply and fixing PVC (SWR) pipes single socketed in any length with rubber ring joints using solvent adhesives fixed to walls or laid in trenches or in floors with brackets etc of 110mm dia complete all as specified and directed.
Supply and fixing PVC (SWR) bends any radius provided with access door of 110mm dia complete all as specified and directed.
Material and Labour for 75mm thick cement concrete (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) as in floor / plinth protection laid in suitable panels finished even and fair all as specified. 6mm joints should be filled with bitumen mastic filling comprising of one part of heated bitumen 85/25 or 80/100 grade and three parts of sand (all by weight) complete all as specified and directed.
Dismanting floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Material and Labour for non skid ceramic colour tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm screed bed CM (1:6) complete all as specified and directed.
Material and Labour for glazed ceramic colour tiles 450 x 350 mm x 7 mm / 350 x 250 x 7 mm thick as in dados, skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering CM (1:4) complete all as specfied and directed.
Material and labour PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specfied and directed.
Material and labour for brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius built in CM (1:6) etc complete all as specified and as directed by Engineer-in-Charge.
Material and labour for form work to flat soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough finished complete all as specfied and directed.
Material and labour for reinforced cement concrete (nominal mix) (1:2:4) type B-1(using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Material and labour for providing cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed.
Material and labour for preparing newly plastered wall surfaces and applying two coats of cement based paint over and after one coat of priming with alkali?resistant primer complete all as specified and directed
Supply and fixing sinks with drainage board made of stainless steel 1 mm thick in kitchen with plugs, washers and waste coupling, waste pipe, including bedding in cement mortar on wall including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460 mm, bowl size 410mm x 330mm x 160 mm complete all as specified and directed.
Supply and fixing 15 mm bore bib taps long nose / long body, cast copper alloy chromium plated fancy type with capstan head handle screwed down, screwed for brass, weight not less than 450 grams ferrule and fixed complete all as specified and directed.
Supply and fixing 15 mm bore steel tubing, medium grade, galvanised with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and water tightness test complete all as specified and directed.
Removing excavated surplus soil etc not exceeding 50 m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft / loose soil complete all as specified and directed.
Material and Labour for formwork to flat sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work; vertical or to batter fair finished surfaces complete all as specified and directed.
Supply and fixing mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
Material and Labour for reinforced cement concrete (nominal mix) (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
Material and Labour for hardcore of gauge of broken bricks not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
Material and Labour 75mm thick PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) in floor as sub base complete all as specified and directed.
Material and Labour 100mm thick PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) in floor as sub base complete all as specified and directed.
Material and Labour for sand filling under floors or in foundations or in cushing bed of cable including watering and consolidation complete all as specified and directed.
Material and Labour for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design and pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness and size/ shape, made by table vibratory method using PU mould, laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding / laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
Material and Labour for glazed ceramic coloured designer seamless tiles 300 x 600 x 7 to 8 mm thick on vertical surface as in skirting, dado set and jointed with neat cement slurry and pointed in coloured cement to match with the surface over and including 10mm thick backing in CM (1:4) complete all as specified and directed.
Supply and fixing 10mm thick frosted toughened glass as in partitions and similar work including cutting to shape rounded corners, drilling holes fixed to wall with two pair of SS clamp to wall clamp complete all as specified and directed.
Material and Labour for 20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, over and including 20mm thick screed bed in CM (1:6) complete all as specified and directed.
Material and Labour for providing edge moulding to 18-20mm thick granite stone of counters vanities etc. including machine polishing to edge to give high gloss finish etc complete all as specified and directed.
Supply and fixing Box type steel windows comprised of tubular frame and shutters made out of 1.25 mm thick mild steel sheet tube factory made with double side shutters wire gauged shutter and glass glazed shutter (wire cloth and glass panes will be measured and paid separately) with side hung shutters with mild steel handles and mild steel peg stay dovetailed or welded including 02 No's mild steel tower bolts 150 mm long for each leaf and 8 mm square bar grill / guard bars at spacing as shown on drawing welded mild steel flat iron frame work, including other fittings, hinges, mild steel handles, tarred hold fasts, PCC blocks for hold fasts etc all as shown on Drawing No CEPZ/TD -354/09 sheet 1/3 to 3/3 including one coat of red oxide zinc primer complete all as specified and as directed.
Supply and fixing solid PVC door frame of size 50mm x 95 mm made out of 5mm prelaminated PVC sheet reinforced with mild steel square tube all as per specification and drawing in SSR Part II complete all as specified and directed.
Supply and fixing factory made solid PVC moulded door shutter with solid black board core 28 to 30mm thick with 2, 4 or 6 raised panel design with 5mm thick moulded prelaminated PVC sheet on the front face and 5mm prelaminated PVC sheet on back face as per specification and drawing in SSR Part II complete all as specified and directed.
Supply and fixing stainless steel butt hinges, size 100 mm complete all as specified and directed.
Supply and fixing stainless steel handles of AISI 316 grade, 19mm dia, 150mm long complete all as specified and directed.
Supply and fixing 200mm long stainless steel sliding door bolts with hasp and staple fixing clips and bolts of AISI 316 grade fixed to door with complete all as specified and directed.
Supply and fixing stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
Supply and fixing 3mm thick figured glass, pin head type and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane complete all as specified and directed.
Supply and fixing 25 mm dia stainless steel curtain rods grade J4, gauge 20mm with final / side knobs, including fixing half openable brackets BR 100mm long with tighting alanke nuts / side end brackets, 10 No's SS rings in one Rmtr (in respective of complete accessories) complete all as specified and directed.
Supply and fixing vitreous china white wash down water closet pan including fixing bolts, flushing cistern, soft close seat cover and flush pipe with 'P' trap, connecting pipe complete all as specified and directed. Make: - Jaquar Cat Part no : - FLS- WHT-5953PPSM, Parryware Verve Cat Part No: - C-0269 and C-0762, Kohler.
Supply and fixing toilet paper holder with cover fixed to walls with chromium plated brass screws complete all as specified and directed. Make: - Parryware Cat Part No: - T-6514A1 or Jaquar Cat Part No: - ACN-7753, Kohler.
Supply and fixing 2 way cast copper alloy chromium plated 15mm bib tap with wall flange fixed to pipe complete all as specified and directed. Make: - Jaguar Cat Part No: - KUP 35041PM or Parryware Cat Part No: - G-4134A1, Kohler.
Supply and fixing health faucet cast copper alloy chromium plated with flexible chrome hose and wall hooks complete all as specified and directed. Make: - Jaguar Cat Part No: - ALD-573 or Parryware Cat Part No: - T-9941A1, Kohler.
Supply and fixing vitreous china white table top wash basins, including waste pipe, brackets and connecting pipe fixed complete all as specified and directed. Make: - Parryware Cat Part No: - Aquiline C8909 or Jaquar Cat Part No : - KUS WHT-35935, Kohler.
Supply and fixing waste coupling 32mm size half tred with 80mm height fixed to wash hand basin and connected to bottle trap complete all as specified and directed. Make: - Jaquar Cat Part No: - ALD 709, Paryware Cat Part No: - T994326, Kohler.
Supply and fixing cast copper alloy chromium plated 32mm size bottle trap with 259mm and 190mm long wall connection pipe and wall flange fixed to wash hand basin and wall complete all as specified and directed. Make: - Parryware Cat Part No: - T3202A1, Jaquar Cat Part No: - ALD769L250x190, Kohler.
Supply and fixing pillar cock cast copper alloy, chromium plated fixed to 15mm dia mild steel pipe complete all as specified and directed. Make: - Jaquar Cat Part No: - KUP 35001PM, Parryware Cat Part No: - G4814A1, Kohler.
Supply and fixing towel ring fixed to wall with chromium plated brackets screws complete all as specified and directed. Make: - Parryware Cat Part No: - T6501A1, Jaquar Cat Part No: - CAN 1121BN, Kohler.
Supply and fixing bib tap cast copper alloy, chromium plated fixed to 15mm dia mild steel pipe complete all as specified and directed. Make: - Jaguar Cat Part No: - KUP 35037PM, Parryware Cat Part No: - G 3470A1, Kohler.
Supply and fixing towel rail fixed to wall with chromium plated braces screws complete all as specified and directed. Make: - Parryware Cat Part No: - T6501A1, Jaquar Cat Part No: - AKP35711PS, Kohler.
Supply and fixing angle cock chromium plated fixed to 15 mm dia mild steel pipe complete all as specified and directed. Make: - Parryware Cat Part No: - G0253A1, Jaquar Cat Part No: - KUP35053PM, Kohler.
Supply and fixing 600mm long PVC connection pipe fixed to 15mm dia pipe complete all as specified and directed.
Supply and fixing 100mm stainless steel grating complete all as specified and directed.
Supply and fixing 100mm PVC (SWR) floor trap / nahni, multi door with grating including jointing with solvent cement complete all as specified and directed.
Supply and fixing in PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls, 50 mm bore complete all as specified and directed.
Supply and fixing PVC (SWR) bends any radius, 110 mm bore complete all as specified and directed.
Supply and fixing PVC (SWR) cowl 100mm dia complete all as specified and directed.
Supply and fixing 250 litre capacity HDPE water storage tank, cylinderical vertical with closed top, having three layers, with over all thickness as per IS with locking arrangements hoisted and fixed in position complete all as specified and directed in SSR Part-II.
Supply and fixing 25mm nipple suitable for HDPE water tank (minimum weight 20mm - 45 gms) complete all as specified and directed.
Supply and fixing 25mm ball valves high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe and fixed (minimum weight 25mm-455 grams) fixed complete all as specified and directed.
Supply and fixing gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe 25 mm bore complete all as specified and directed.
Supply and fixing 25mm water steel Tubes, 'medium grade' galvanised,with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Cutting chases, pinning in. making good to facings in brick wall where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
Material and Labour for provision of roof treatment with polymeric water proofing membrane all as given below :- (a) Applying a coat of bituminous primer conforming to IS : 3384-1986 @ 1.2 Kg/sqm on prepared surface and allowed to dry. (b) Applying and laying 3mm thick APP membrane having non woven polyester matt at core and covered with high quality polymeric asphaltic protected thermo fusible HMHDPE film on both sides with over laps 10cm and 15 cm at longitudinal and transverse direction respectively and sealed by flame, sealing all overlaps complete including treatment at all junctions and corners. The membrane shall be torched into groove on vertical plane and groove sealed with cement mortar 1:3. (c) Material and Labour for two coats of aluminium paint on membrane surface all as specified and directed.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed.
Material and Labour rendering 5mm thick on fair faces of ceiling surfaces in cement mortar 1:3, finished even and smooth without using extra cement complete all as specified and as directed.
Material and Labour for preparing newly plastered ceiling surfaces and applying three coats of white wash complete all as specified and directed.
Material and Labour for Preparation of new steel surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over and after priming a coat red oxide zinc chrome (ordinary tint) complete all as specified and directed by Engr-in-Charge.
Material and Labour for 150mm dia Salt glazed stoneware drain pipes laid in trenches and jointed complete all as specified and directed.
Material and Labour for brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick wall in CM 1:4 complete all as specified & directed by Engineer-in-Charge
Supply and fixing double bowl stainless steel sink with draining board, made out of 1.00mm thick sheet for kitchen or lab with plug, washers waste pipe, cast ironn cantilever brackets, connecting union overall size 1015x500x160mm with two bowl complete all as specified and directed.
Supply and fixing 12 mm thick Plywood, grade BWR, type BB,and teak wood 6mm thick lipping, veneered with decorative laminate 0.9mm thick type 1 of surface finish colour and pattern as approved fixed with screws to timber frame work for shelf, drawer and shutter full size fitted under the kitchen cooking platform and other platform incl fittings etc complete all as specified and directed including provision of fixing arrangement Make Kitply/Greenply/Century ply.
Supply and fixing 30mm wide flap (when open) SS Continuous (piano) hinges, bright finish or electrogalvanised fixed to Kitchen cuboard complete all as specified and directed.
Supply and fixing stainless steel handle 200mm complete all as specified and directed. Make Hettich/ozone/kaff
Material and Labour for 25mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate) complete all as specified and directed.
Material and Labour for Non - skid joint free coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15 mm thick for finishes in CM 1:6 complete all as specified and as directed by Engr-in-Charge..
Material and Labour for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishingincluding screed bed or bedding layer of mortar 20 mm thick for finishes in CM 1:6 complete all as specified and as directed by Engr-in-Charge..
Material and Labour for Machine cut Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including rendering 10 mm thick in CM 1:4 as backing of wall tiles complete all as specified and as directed by Engr-in-Charge.
Taking down Chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m each but with shutters (without taking off shutters from the frame) complete all as specified and directed.
Supply and fixing for 125 x 60mm Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and directed.
Material and Labour PCC (1:3:6) type C1 as in bed blocks for hold fast, backfill to pressed steel frames for doors including necesssary formwork complete all as specified and directed.
Supply and fixing for 30mm thick 2nd class hardwood Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed.
Supply and fixing for 30mm thick 2nd class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
Supply and fixing for 140mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed.
Supply and fixing for 200mm long Mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed to door complete all as specified and directed.
Supply and fixing for MS 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
Supply and fixing for 150mm long Extruded aluminium alloy handles, fabricated type, anodised, fixed to door complete all as specified and directed.
Supply and fixing 300mm long Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed to door with complete all as specified and directed
Supply and fixing in repair 'E' board everest make 600x600x4mm thick white prelaminated sett embosed reinforced designer ceiling board tiles of approved texture at all height laid on hot dipped galvanised iron imposed grid with 24mm wide T-section exposed flanges which shall be poweder coated white. The frame work shall comprise of main runner made from 0.33 mm thick GS sheet and of size 24x32x300mm abd soaced at 1200mm centers securely fixed to be structural soffts by approved hangers at 1200 mm maximum centrers. Hangers of GI wire 4mm dia to be fixed by approved rawl plug level and justers and screws etc. The last hanger at the end of each main runner shall not be grater than 450mm from adjacent wall, Flush fitting of 1200mm long cross tee (with double stiching) to be interlocked between main runners at 600mm center to from 1200x600mm modules cross tee longer than 600mm to be supported independtly. 600x600mm dodules to be formed by fitting 600mm long cross tee centrally between the 1200mm cross tee. Tee, perimeter wall angle shall be of 0.45mm thick GS sheet of size 19x19mm and 300mm long of white colour all as per manufacture insturction.
Taking down and Supply and fixing 15mm water steel Tubes, 'medium grade' galvanised,with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed
Material and Labour Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6, finished even and smooth without using extra cement complete all as specified and as directed.
Material and Labour for two coats of oil bound distemper of wall to newly plastered surfaces over 1mm thick wall care putty including preparation of surfaces complete all as specified and directed
Material and Labour for one coat of oil bound distemper of wall to old plastered surfaces including preparation of surfaces complete all as specified and directed
Material and Labour for Preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over and after priming with a coat pink primer complete all as specified and directed by Engr-in-Charge.
E/M Portion: - Taking down old unsv copper/aluminium point wiring concealed / batten (light, fan, socket or power) complete, including fixture and fittings such as switches,sockets, ceiling roses,bell push,bell electric,lamp holder,bulk head fitting, pendants, regulators, sockets, light fitting and any type switch board wooden/iron,round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed
Material and Labour for point wiring for one light/fan/call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 sqmm copper conductor multistrand FRLS, PVC insulated (unsheathed) drawn into an including new concealed PVC rigid/ 1.8mm wall thickness ISI marked including new CI/pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and directed Note : (a) wiring shall be done by using proper colour coding (b) Earth wire shall be of green colour (c) On RCC roof/celing PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engr-in-Charge.
Description All as per item No 136 here in above but One 5 pin socket outlet 5 amps on the same boardcomplete all as specified and directed
Description All as per item No 136 here in above but One 5 pin socket outlet, 5amps, independent complete all as specified and directed
Description All as per Item No 136 here in above but for one 5 pin socket outlet 15 Amps on Independent board with cables 2.5 sqmm size complete all as specified and directed
Description All as per item No 136 Here in above but drawn through an including new surface conduit PVC rigid non metalic conduit 20 mm dia for socket outlet 5 amp independent board complete to accomodate the accessories for PVC Gang Box complete all as specified and directed
Description All as per item No 136 Here in above but drawn through an including new surface conduit PVC rigid non metalic conduit 20 mm dia for socket outlet 15 amp independent board complete to accomodate the accessories for PVC Gang Box complete all as specified and directed
Material and Labour for replacement distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as specified and directed Note:- Distribution board and MCBs should be same make.
Supply and fixing in replacement 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed
Supply and fixing in replacement SPN 32 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed
Supply and fixing in replacement for switch piano, flush type single pole one way 5Amp, 240 volts complete all as specified and directed
Supply and fixing in replacement for switch piano, flush type single pole one way 15 Amps, 240 volts complete all as specified and directed
Supply and fixing in replacement Socket outlet 2 in 1, 3 pin, 5A complete all as specified and directed
Supply and fixing in replacement Socket outlet 5 pin, 15 Amp, flush type, 240 Volts, 6 pin flush type complete all as specified and directed
Supply and fixing in replacement Ceiling Rose 3 terminal surface type complete all as specified and directed
Supply and fixing in replacement LED lights fitting 1x 20W, 220V, AC decorative box type complete with LED tube rod 20 watts driver, holder and power factor >0.95 , 100 Lumen/Watt, 6500 K cool day type conforming to ISI including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. (4' ft long ) with LED rod 20 watt, 230 Volts 50 Hz. complete all as specified and directed
Material and Labour in replacement for Sub main wiring with proper colour coding , insulated , unsheathed , multistranded ,copper conductor FRLS, cable of 2 run 6 Sqrmm for phase and neutral and one run of 6.0 Sqrmm for earth wire unsheathed , miltistranded , copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and directed Note : Wiring shall be done in proper colour coding.
Supply and fix in replacement exhaust fan, steel body AC single Phase. 230V of size 350m sweep with, blades, and frame and louvers complete all as specified and directed.
Supply and fixing in replacement of Vertical Distribution Board (TP&N) 4 way double door suitable for and including MCCB 125 Amp 16 KA four pole as incomer and out going MCBs and should be IP 43 protected with Copper BusBars, Neutral Links, Earthing bar complete all as specified and directed Note:- (i) Rate includes MCCB four pole 125 Amp, 16 KA, 415 volts with adjustable thermal settings. (ii) MCBs shall be measured and paid separately. (iii) TPN DB and MCCB should be of same make.
Supply and fixing in replacement PVC box (gang bx) surface mounted heavy duty 3 way complete with ocket outlet 2 in 1 , 6 pin 5 amp 240 volt alongwith switch piano 5 amp 240 volt complete all as specified and directed
Supply and fixing in replacement PVC box (gang bx) surface mounted heavy duty 3 way complete with ocket outlet 2 in 1 , 6 pin 5 amp 240 volt alongwith switch piano 15 amp 240 volts complete all as specified and directed
S&L and testing cable XLPE Insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable (Heavy duty) with stranded aluminium conductor 1100 V grade cross sectional area 25 Sqmm, 4 core in and incl taking out old one complete all as specified and directed
Supply and laying comman burnt clay building sub class `B' bricks, laid over sand Cushioning laid at right angle along with cable, including taking down old one complete all as specified and directed
S&L in replacement of GI tubing tight graded 40 mm bore incl all accessories for encasing cables for mechanical protection, laid under plinth/floors/path culverts with complete accessories such as bends/sockets/reducers/saddles incl necessary threading/drilling works complete all as specified and directed (MS work will be measured under separate item in schedule)
Material and Labour of distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 4 way 240 volts double door complete all as specified and directed Note:- Distribution board and MCBs should be same make.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed
Supply and fixing SPN 32 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed
Supply and fixing switch piano, flush type single pole one way 5Amp, 240 volts complete all as specified and directed
Supply and fixing Switch socket outlet combined 2 in 1 , 3 pin 5 amp and `15 amp flush type , 240 volts complete all as specified and directed
Supply and fixing Ceiling Rose 3 terminal surface type complete all as specified and directed
Material and labour Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed
Material and labour Self ballast LED retrofit Lamp with PVC body and PC Diffuser 9 watt 230 Volt 6500K complete all as specified and directed
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type complete with LED tube rod 20 watts driver, holder and power factor >0.95 , 100 Lumen/Watt, 6500 K cool day type conforming to ISI including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. (4' ft long ) with LED rod 20 watt, 230 Volts 50 Hz. complete all as specified and directed
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed
Material and Labour for Sub main wiring with proper colour coding , insulated , unsheathed , multistranded ,copper conductor FRLS, cable of 2 run 6 Sqrmm for phase and neutral and one run of 4.0 Sqrmm for earth wire unsheathed , miltistranded , copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and directed Note : Wiring shall be done in proper colour coding.
Material and Labour for Earthing complete with galvanised mild steel earth plate electrode of size 600x600x6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised ironl including PCC pit in PCC 1:2:4 type B-1 pre-cast RCC cover slab using reinfocement with suitable handle made of round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube flor watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion complete all as specified and directed
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate,NRV, connection piece etc. Note:- Rates are deems to be includes the cost for fixing of 4 Nos rawl plug of suitable size (4" to 6 ") nuts and bolts , grouting work in RCC/ Brick wall complete all as specified and directed
Material and Labour for cutting to existing pipe 15/20mm dia in position and insertion of T , additional alteration in position complete with GI fittings as required at site for connecting New GI pipe complete all as specified and directed by Engr-in-charge.
Supply and fix Galvanised iron pipe medium grade of size 15mm complete with all fittings such as bend, tee, reducer, elbow and union of require size complete all as specified and directed. Note:- Rates are deemed to be included for fixing of MS clamps of suitable size to hold the GI pipe.
Supply and fix gun metal or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete of size 15 mm dia complete all as specified and directed.
Material and Labour PVC connection pipe heavy duty ISI marked of 15mm size with PTMT nuts of length 450mm from GI pipe to Water cooler complete all as specified and directed.
Supply and fix Bib Tap fancy type cast copper alloy with crutch or butterfly handle, screwed down for iron pipe 15mm dia complete all as specified and directed.
PAKAYA BUILDERS AND DEVELOPERS PVT LTD
M/S PRITHIVI RAJ AND SONS
JK BUILDERS AND DEVELOPERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .