Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.1 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹45.3 L+₹3.1 L (7.36%)Rejected-Finance DAIRY FARM JUNCTION VIJAY BAUGH ROAD SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Not a lowest bidder | |
| 3 | L3₹47.1 L+₹5.0 L (11.8%)Rejected-Finance 956 2 CHANDERSEKER ENTERPRISE OPP MARICAR HOSPITAL OLD CCS JUNGLIGHAT SOUTH ANDAMAN ANDAMAN NICOBAR 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L3 | Rejected-Finance Not a lowest bidder | |
| 4 | L4₹47.9 L+₹5.8 L (13.7%)Rejected-Finance | L4 | Rejected-Finance Not a lowest bidder | |
| 5 | L5₹50.2 L+₹8.0 L (19.0%)Rejected-Finance NEAR OLD CCS JUNGLIGHAT SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L5 | Rejected-Finance Not a lowest bidder |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
19 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Brichgunj
Garrison Engineer Brichgunj, Port Blair
SPL REPAIR AND CERTAIN LBW WORKS UNDER AGE EM GE BRICHGUNJ
2023_MES_613333_2
8389A
Open Tender
Civil Works
Item Rate
180 days
Brichgunj
As per NIT
9 documents required · 9 mandatory
₹500
Garrison Engineer Brichgunj
₹88,000
Yes
1 Dec 2023
31 Aug 2023
21 Sept 2023
31 Aug 2023
19 Sept 2023
7 Sept 2023
Amount
Supply, install, testing and commisioning of junction boxes, weather/vermin proof made out of 3.15mm thick CRCA sheet(CPRI approved) duly powder coated of size 60cm X 60cm x 60cm(depth), floor mounted free standing type with provision of space for 160A ,4P,MCCB, aluminium bus bar 300 Amps current carrying capacity for 3 Nos phase & neutral with colour coded heat shrinkable insulated sleeves and insulated support, mounting the junction box with PCC (1:3:6) type C1, bedding upto height of 30cm above ground level , including taking down old terminal boxes complete all as directed and as specified.
M&L, Earthing complete with galvanised steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of plate not less than 1.5m below normal ground level connected tocopper earth strip 32 x 6mm as earth lead by means of bolts, nuts, washers and check nuts made out of copper earth plate all as shown on Electrical Plate No. 3 of SSR Part-I including testing on completion complete all as specified and directed. Note 1: The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, RCC 1:2:4 type B-1 using 20mm graded stone aggregate, 50mm thick RCC cover slab reinforced with 6 Nos of 8mm dia TMT bars both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub-heading earthing, specified on Sl. Page No. 422 of SSR Part-II.
Supply and fix G strip 32mm x 6mm buried in ground complete all as specified and directed.
S & F in repairs SMC junction box of inner size 1415X1415X450 mm , light weight including 4 way Connector block of 63A rating ,with 6amps MCB fixed on pole/Wall/ Panel using necessary fasteners all as directed and as specified.
S & F in repairs SMC junction box of inner size 3020X3020X500 mm , light weight including 4 way Connector block of 63A rating ,with 6amps MCB fixed on pole/Wall/ Panel using necessary fasteners all as directed and as specified.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3.5 core completed all as specied as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core completed all as specied as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core completed all as specied as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core completed all as specied as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core completed all as specied as directed.
Supply and lay HDPE double wall corrugated pipes and including fittings such as couplers, bends, end caps etc., ISI marked of outer dia of 90mm and inner dia of 76mm polyethylene with smooth internal and profile external surface for non pressure under ground cable complete all as speciedd and as directed.
Supply and lay HDPE double wall corrugated pipes and including fittings such as couplers, bends, end caps etc., ISI marked of outer dia of 63mm and inner dia of 50mm polyethylene with smooth internal and profile external surface for non pressure under ground cable complete all as speciedd and as directed.
Supply and lay HDPE double wall corrugated pipes and including fittings such as couplers, bends, end caps etc., ISI marked of outer dia of 40mm and inner dia of 32mm polyethylene with smooth internal and profile external surface for non pressure under ground cable complete all as speciedd and as directed.
Excavation in trenches not exceeding 1.50m wide and n.exc 1.5m depth for foundation, laying of UG cables / pipeline etc or for shafts, wells, cesspits, manholes, pier holes etc not excluding 10 Sqm on plan in hard/dense soil and getting out , complete all as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n.exc. 25cm in any type of soil complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point as directed.
Supply and lay light grade GI tube for cable protection of size 50mm
Disconnecting and taking out old U/S defective LT UG cabler of any size/type from trenches/wall/poles/pipes/all as directed.
Supply and laying in trenches or on pedestal wherever required , jointing , testing and commissioning of ISI marked 110 mm outer dia HDPE pipes of pressure rating 10 kgf/cm2 including necessary clamps as required at site all as specified and as directed.
All as per Item Sl No 26.00 here-in-before but 90 mm outer dia HDPE Pipe complete all as specified and as directed.
All as per Item Sl No 26.00 here-in-before but 63 mm outer dia HDPE Pipe complete all as specified and as directed.
Supply and laying in trenches or on pedestal wherever required ,jointing ,testing and commissioning of ISI marked HDPE pipes Pressure rating 6 kgf/cm2 of 50 mm bore including taking down of existing unserviceable pipes all as specified and as directed.
All as per item No 27.00 here in before but 40 mm dia complete all as specified and as directed.
S&F of Sluice Valve, Cast Iron body, Stainless Steel Spindle, Gun Metal Rings including Wheel for operation, Flanged and Drilled, size 100 mm bore, confirming to IS - 14846, Class PN -1.6, Long Body type including necessary flanged for fixing with 110 mm outer dia HDPE pipes and all Jointing materials like flanged socket, spigot etc complete all as specified and as directed.
All as per Item Sl No 31.00 here-in-before but of size 80 mm and fixing with 90 mm outer dia HDPE Pipe complete all as specified and as directed.
M&L for brand pop up impact rotor sprinkler of radius not less than 15 mtr colour in black recommended discharge rate approx 24 Ltr/Min adjustable from 2 digree to 360 digree suitable including swing joint and service saddle all as specified and directed
M&L for PCC 1:3:6 type C1 (using 20mm graded aggregate) as in coping, foundation, support for HDPE Pipe complete, all as specified and as directed.
M&L for cutting bittumen road / hard top at site as required for laying of pipe line and making good of disturbed surface as per existing top with 20mm graded stone aggregate and bitumen layer etc complete all as specified and as directed.
M&L for Construction of Brick Masonry valve chamber of size 900x900x 900mm (Internal dimensions) with PCC 1:4:8 foundation 150mm thick, brick work built in CM 1:6, PCC 1:3:6 coping 50mm thick, plastering 15mm thick in CM 1:6 to all internal and exposed surfaces including excavation earthwork in hard/dense soil, MS sheet cover 4mm thick with locking arrangement embedded in PCC and painting to MS cover with two coats of synthetic enamel paint over one coat of red oxide primer etc complete all as specified and directed.
S&F non return valve with flanged ends of any pattern with bypass arrangement and ISI marked including jointing materials and necessary joints and nut bolts with washer for flanged ends of size 100 mm complete all as specified and as directed.
S&F of CI Foot valve of 100 mm bore including necessary bolts and nuts complete all as specified and as directed
S&F Ductile Iron Pressure pipes with flanged ends suitable for suction line of size 100 mm dia Class "K-9" conforming to IS-8329 including jointing mtrls like nuts & bolts, rubber gasket for jointing complete all as specified and as directed.
M&L for cutting existing 100 mm GI/HDPE pipe line and insertion of Tee as per site requirement and tanking branch connection all as specified and as directed.
All as per Item Sl No 41.00 here-in-before but 110 mm dia HDPE Pipe complete all as specified and as directed.
S&F Air Release Valve, 100mm bore of pipe with all jointing materials complete all as specified and directed.
Supply and lay cable XLPE Insulated screened ,PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductors all as per IS -7098(Part-1 1977) and Part 2- 1985 of size 50 sqmm 4 core laid in trench / wall / floor of following size all as specified and as directed.
Supply & lay cable protection pipe of HDPE (DWC) incl couplers, bends etc of size 65 mm OD suitable for 50 sqmm XLPE Cable confirming to IS 14930 -II and ISI Marked all specified and directed.
M&L for fabrication of MS Busbar Chamber outdoor type of nominal dimension not less than 600 mm x 600 mm x 400 mm duly provided with 04 Nos aluminimum bus bar alongwith fixing one 4 Pole MCCB of 100 Amp weather/vermin proof with both way opening duly provided with neoprene rubber gasket on CRCA steel sheet encloser including making connection /thimbles complete all as sepcified and directed
Sree Tirumala Enterprises
CHANDER SEKER ENTERPRISE
M/s Prem Enterprise
SKV Engineering
Reliance Sales Agency
M/s Kamal Electrical
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .