Loading…
Loading…
Tender Value
₹3.0 Cr
EMD Value
₹5.9 L
Closing Date
14 May 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
SIGNAL
15 conditions · 3 needing a document upload
For works costing more than Rs.50 Lakhs:The tenderer must have minimum average annual contractual turnover of V/N or "V" whichever is less; where V = Advertised value of the tender in crores of Rupees. N = Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB in GCC APRIL 2022, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. Non submission of the above, the offer will be summarily rejected. (Ref : Advance Correction Slip No.1 dt:14/07/2022 to IRSGCC- 2022 ).
Option for Payment: An option is available that the Supplier/Contractor to take payment from Railways through Letter of Credit (LC) arrangement, having the estimated value of Rs.10 Lakhs and above. All the suppliers/contractors are requested to make use of this facility from Railways.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender. Note for Item 10.1: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organization, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
"The Similar work is defined as, "Any signal interlocking works involving EI or RRI or PI or IBS or IBH or LC gate or yard modification or UFSBI or Track circuit (AFTC or DC TC) or Axle Counter (SSDAC or MSDAC or HASSDAC) or Automatic signaling."
17 conditions · 3 needing a document upload
All the tenderers/Contractors have to deposit Earnest Money Deposit (EMD) & Tender Document Cost (TDC), in respect of e- tendering, should be accepted through net banking or payment gateway only. Fixed Deposit Receipt (FDR) will not be accepted as EMD for tenders invited on IREPS (e-tender portal). When submitted in physical form, the Tenderer shall upload scanned copies of financial instruments such as EMD, Tender form cost, mandatory credentials such as experience, turn over certificates and any other documents as applicable. All documents related to Partnership deed/Joint venture/ Consortium/ MOU, duly signed by the notary public, should be uploaded at the time of submission of bid S&T/SA failing which offer will be summarily rejected.
Until a formal agreement is prepared and executed, acceptance of this tender shall constitute a binding contract between us subject to modifications, as may be mutually agreed to between us and indicated in the letter of acceptance of my/our offer for this work.
I/We also hereby agree to abide by the Indian Railways Standard General Conditions Of Contract, with all correction slips up-to- date and to carry out the work according to the Special Conditions of Contract and Specifications of materials and works as laid down by Railway in the annexed Special Conditions/Specifications, Schedule of Rates with all correction slips up to date for the present contract
I/We have read the various conditions to tender attached hereto and agree to abide by the said conditions
I/We also agree to keep this tender open for acceptance for a period of 45 days from the date fixed for opening the same
I/We hereby Confirm that the rates, rebates and/or other financial terms, if any, quoted by us in the relevant fields of the Financial Bid page will only be the ruling terms for deciding the inter-se ranking, and any such condition having financial repercussions, if quoted by us anywhere else including attached documents shall not be considered for deciding inter-se ranking
However, Railways shall have the right to incorporate any such condition quoted by us, in the contract, at their discretion, if contract is placed on us.
I/We have read the various conditions attached/ referred to in this tender document, and agree to abide by the said conditions.
Deployment Of Qualified Engineers At Work Sites By The Contractor. The contractor shall also employ Qualified Graduate Engineer or Qualified Diploma Holder Engineer, based on value of contract, as may be prescribed by the Ministry of Railways through separate instructions from time to time.(As per RB ltr no.2012/CE-I/CT/O/20 dt:10.05.2013)
One qualified Graduate Engineer when the cost of the work is Rs. 200 lakhs and above.
One qualified Diploma holder Engineer when the cost of the work 9.1.1 to be executed is more than Rs.25 lakhs but less than Rs.200 lakhs.
In case the contractor fails to employ the technical staff as aforesaid, he shall be liable to pay a an amount of Rs.40,000/ (Rupees Forty thousand) for each month or part thereof for the 9.1.2 default incase of Graduate Engineer and Rs.25,000/- (Rupees Twenty five thousand) for each month or part thereof for the default in case of Diploma holder (Engineer)
In case of more than one L-1 bidders, tender may be awarded to tenderer having higher Bid Capacity. In case Bid Capacity is also the same, tenderer having done more value of similar work in last three previous financial years and the current financial year upto the date of opening of the tender, may be selected for the award. Instructions with respect to Bid Capacity will follow.
All the contracts on works/goods/services will be subject to the new GST act as applicable from time to time. Contractors have to register themselves with GST authorities and to furnish the GST registration number in order to process the bills from 01.7.2017
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
I/WE also hereby agree to abide by the INDIAN RAILWAY GENERAL CONDITIONS OF CONTRACT- APRIL 2022, with all correction slips up to date and to carry out the works accordingly.
In the e-tendering process, it is mandatory that every tenderer/contractor/firm registered with WWW.IREPS.GOV.IN to submit your bank details i.e.Name of the Bank along with Bank Branch Code, Account Number, IFSC Code, and PAN Number
SALEM DIVISION: Provision of tools and equipments for implementation of SMMS, Painting of S&T assets, Fencing of critical locations and other reliability improvement works over Salem Division.
SA-SG-120-I-OT-03-2026
SA-SG-120-I-OT-03-2026
Open
Works - General
12 Months
Salem, Tamil Nadu
₹0
₹5.9 L
14 May 2026
21 Apr 2026
30 Apr 2026
60 items across 1 schedule · ₹1,54,76,422.38 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | "Submission of all relevent final 'As mades' of circuit diagrams, contact analysis charts, termination particulars of apparatus cases and cable termination rack, power supply arrangements, relay index board, cable plans, cable route plans, red boundary plans and all other particulars covered under various schedules. All 'As mades' shall be prepared by the Contractor in AUTOCAD 2000 or latest and submitted in CDs. One copy of the 'As mades' check print shall be submitted before Testing the circuits. The final negatives shall be made in tracing sheet (80 to 90 gsm). All 'As mades' except cable plan, cable route plan, bonding diagram & power supply diagram shall be prepared in A3 size. On approval the contractor shall submit along with the negatives, 8 copies in each, duly making booklet neatly bound. Out of 8 sets, 2 sets of drawings and other plans shall be kept in transparent plastic cover (2 sheets back to back in one plastic cover) and handed over to Railways. Also the contractor has to supply one set of As mades in 'Reproduction Film'. The approved circuit diagram will be issued by Railways in soft copy as well as two sets of hard copies. Wherever alterations to existing circuits are involved, the existing as-made circuit diagrams will be supplied by Railways either in CDs or RP film. The Contractor shall incoporate the details of all the new wirings and alterations in the CD/ RP film and submit them to Railways. Onapproval 8 copies shall be made for As-made circuit diagrams also as mentioned above" | Sheet | 100.00 | 382.12 | 38,212 |
| 2 | S u p p l y o f Protocol Converter suitable for Electronic Interlocking system equipment | Numbers | 4.00 | 68,051.41 | 2,72,205.64 |
| 3 | S u p p l y o f D u a l C a r d R S 2 3 2 t o EI/OFC converter suitable to insert in the Datalogger Eurorack for inter-linking Datalogger/MFEP | Numbers | 4.00 | 45,367.61 | 1,81,470.44 |
| 4 | Wiring o f Relay Inputs t o Wa g o Block and Wago block to Datalogger. Necessary Wagos required is included as per schedule | Per Unit | 100.00 | 285.86 | 28,586 |
| 5 | Wiring of Analog Voltages from IPS Room to Datalogger. Necessary Wa g o s required is included as per schedule | Numbers | 50.00 | 285.86 | 14,293 |
| 6 | Provision of earth electrodes as per drawing No.SG/CN/02/13 and earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, SM's room for block and control, and earthing of all equipments in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS flat 35mm X 6mm/19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, M sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 5.00 | 1,707.55 | 8,537.75 |
| 7 | Supply of DC-DC Converter of Capacity 110V DC/24-40V, 10A as per RDSO Specifications RDSO/SPN/165 /2012 Ver 3.0 or latest | Numbers | 8.00 | 21,381.6 | 1,71,052.8 |
| 8 | Supply of 'B type choke IRS:S 65-83 | Numbers | 400.00 | 2,855.6 | 11,42,240 |
| 9 | "Supply of distilled water plant similar to'KILBURN' make capacity 3.5 to 4.5 Lits. per hour, with two detachable heating elements of 1500W each to work on 230VAC, single phase, fitted with automatic cut-outs and removable connectors, with Stainless Steel boiling chambers, condenser pipe, toughened glass lid; Distilled water plant, tank 200 Litres capacity similar to sintex make, GI pipe 25mm dia, power plug with socket, regulating valves, jelly, cement, sand and other materials shall be supplied by the Contractor" | Numbers | 10.00 | 25,774.2 | 2,57,742 |
| 10 | "Installation o f distilled w a t e r p l a n t with provision o f w a t e r supply connection from water tap to water tank, water tank to distilled water plant using G . I Pipes 25mm dia and with regulating valves, provision of separate power supply socket a n d wiring. This work includes fixing of 2 Nos. of rails on the wall a n d g r o u t i n g a s instruc te d by Railway representative at site. (Cut rails will be supplied by Railways)." | Numbers | 10.00 | 11,745.65 | 1,17,456.5 |
| 11 | Installation of power equipments like battery chargers, transformers, transformer rectifiers, invertors, D C - D C convertors etc., in the apparatus cases and wiring the same using wire PVC 7/1.4mm a n d 3/0.75mm copper as per the approved wiring diagram and painting of particulars in the inside of the doors of the apparatus cases. The work also includes provision o f protective arrangements i n bare terminals carrying high voltages. (Supply of power equipments is not included in this schedule).[Wire PVC 7/1.4mm and 3/0.75mm copper, protective arrangements, paint and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 8.00 | 1,708.01 | 13,664.08 |
| 12 | Supply a n d provision o f normal joint using Thermo shrink jointing k i t (RDSO specs No TC/77/2012 ( Rev.3) with amendment No.1&2 o r latest.& jointing k i t t o be inspected by RDSO) f o r 4 / 6 quad cable normal joint. The work includes excavation of joint p i t o f size 1mX1.5mX1.5m and closing t h e sam e after completion of cable joint as per the instruction of Railway representative at site. | Numbers | 30.00 | 4,628.91 | 1,38,867.3 |
| 13 | S u p p l y a n d installation o f 2 4 Fi b r e Joint enclosure f o r armoured optical fi b r e cable c o n f o r m i n g t o RDSO spec.RDSO/SPN/TC/68/2014 rev2.0 or latest | Numbers | 20.00 | 13,647.37 | 2,72,947.4 |
| 14 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. (Laying of cables is not included in this schedule) | Metre | 6000.00 | 64.1 | 3,84,600 |
| 15 | Removing/breaking of existing RCC slabs on the Passenger Platform, trenching to a depth o f 0 . 6 m t o accommodate t h e additional cables, replacing the slabs removed after the cables are laid and replastering with cement mortar, refilling the trench by ramming and consolidating i t a s p e r t h e instructions of Railway Representatives a t site. (Laying of cables is not included in this schedule). | Metre | 300.00 | 314.41 | 94,323 |
| 16 | Excavation of trench along route of existing c a b l e d u c t , o p e n i n g t h e s l a b s to a c c o m m o d a t e a d d i t i o n a l c a b l e laying, REPOSITIONING the slabs removed after the cables are laid and PLASTERING with cement mortar, and refilling the trench by ramming and consolidating it as per the instructions of Railway Representatives a t site. (Laying of c a b l e s i s n o t included i n t h i s schedule.) [Cement,M Sand and all other miscellaneous materials required f o r the work shall be supplied by the Contractor]. | Metre | 500.00 | 161.92 | 80,960 |
| 17 | Excavation of trench to a depth of 1 Mtr. for track crossing of cables, refilling of trench by ramming a n d consolidating i t a s p e r the instructions of Railway representative at site a f t e r l a y i n g o f D W C / RC C p i p e s . During excavation of trench, it has to be ensured that the excavated soil does not mix with the ballast available. The depth of 1m trench shall b e f r o m t h e bottom o f sleepers for track crossings. Laying of cables and DWC pipes is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not included in this schedule). | Metre | 300.00 | 385.45 | 1,15,635 |
| 18 | Provision of GI pipes (50/100mm dia) for cable laying with offset at both ends and with couplings over RCC bridges, drainage, culverts, and girder bridges. For RCC bridges, drainage, and culverts, the pipes shall be mounted on concrete masonry supports of size 300mm x 300mm x 300mm at an interval of 2 meters. For girder bridges, the pipes shall be fixed on suitable MS clamps at an interval of 2 meters. The ends of the pipes shall be closed with brick masonry abutments to ensure that no cable is exposed. The work shall be carried out as per the instructions of the Railway representative at the site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).Stone jelly (20/25mm size), bricks, sand, cement, MS angles, flats, bolts, nuts for manufacturing and fixing clamps, bricks, M sand, cement, and other miscellaneous materials for the work shall be supplied by the contractor. | Metre | 360.00 | 208.54 | 75,074.4 |
| 19 | Provision of GI pipes (50/100mm dia) for cable laying in hard rocky area with off sets at both ends duly supported b y concrete blocks of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall be closed with brick masonry abutments work so that no cable is exposed, The work shall be carried out as per the instructions of Railway representative at site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).[Stone jelly of size 20/25mm, bricks, sand, cement, a n d a l l other miscellaneous materials required for the work shall be supplied by the Contractor]. | Metre | 180.00 | 182.87 | 32,916.6 |
| 20 | Laying of signaling/power/ telecommunication cables a s p e r cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc.(Supply o f cables i s not included in this schedule). | Metre | 16000.00 | 18.18 | 2,90,880 |
| 21 | "Refilling of cable trench 1m depth by 0.3m width throughout, with earth after laying of c a b l e s , a n d consolidating t h e t r e n c h by ramming and levelling." | Metre | 6000.00 | 15.4 | 92,400 |
| 22 | "Digging of pit to a depth of 800mm of size 300mmX300mm, c a s t i n g o f concrete foundation o f s i z e 300mmX300mmX300mm and Placing of RCC cable markers on top of t h e foundation a n d refilling t h e p i t and consolidating i t b y r a m m i n g . T h e cable markers shall be provided at an interval of 20 Mtrs. within station limits and 50 Mtrs. outside station l i m i t s throughout t h e cable route, diversions a n d a l s o a t every track/road crossing." | Numbers | 120.00 | 123.35 | 14,802 |
| 23 | Excavation o f c a b l e c o i l p i t t o a s i z e of 1.5mx1.5m a n d d e p t h a s instructed by Railway representative at site, for coiling the cables i n r e a r o f r e l a y rooms/ A F TC huts, apparatus cases etc. The work includes coiling t h e underground cables a n d placing closely o n e layer o f country bricks o f size approx. 220mm x 100mm x 60mm breadth wise above the cables to cover all the cables in the cable pit, closing and consolidating the pit by ramming and levelling.[Country bricks of size 220mmx100mmx60mm (approximately) shall be supplied by the Contractor]. | cum | 10.00 | 949.05 | 9,490.5 |
| 24 | " R o a d c r o s s i n g / Tr a c k C r o s s i n g through Horizontal Drilling at approximately depth of 1.5 to 2 m below t h e formation level of the earth including insertion of HDPE pipe/DWC pipe along with couplers, drawl of cable (or) direct drawl o f cables etc . (Note: T h e pilot used for HDD should be of sufficient size to s u i t insertion o f H D P E / D W C p i p e o f size 120mm (outer dia.) or direct drawl of three cables (Signalling/Power/Quad/OFC) or three nos.of 4 0 m m d i a H D P E p i p e o r a n y other combination as directed by the site engineer) ( Supply o f HDPE pipe i s not covered in this schedule)" | Metre | 100.00 | 1,351.45 | 1,35,145 |
| 25 | B l o w i n g / D r a w i n g o f O F C cable/Power cable/Signalling c a b l e i n s i d e permanently solid lubricated HDPE Pipe already laid. This work includes necessary duct integrity test for solid lubricated H D P E pipe. ( This includes Transportation o f materials from nominated stores to site) | Metre | 4000.00 | 23.43 | 93,720 |
| 26 | Supply of Signal post telephone with facility o f p a g i n g a n d talk-back including voice communication e q u i p m e n t w i t h suitable switching arrangement at the Signal post and at SM's room as per specification enclosed in t h i s document. T h i s includes drawl o f tail cable through G I pipe 25mm dia and 2 mtrs long duly clamped to Signal post with bend as required a t site, termination of tail cable at one end in the apparatus case and other end in the console. In the SM's room, console shall be fixed on a table top. T h e wiring shall be done using wire PVC 16/0.2mm copper. [Talk- back equipment complete including housing b o x , w i r e P V C 16/0.20mm a n d all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 15.00 | 11,897.35 | 1,78,460.25 |
| 27 | Manufacture and supply o f M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug i n type a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing o f p l u g b o a r d s , r e l a y s , r e s i s t o r s and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram a n d painting the particulars.[Wire P V C copper, 3/0.75mm and 1 6 / 0 . 2 m m c o p p e r , P h y n o l i c synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1 9 9 5 - Ty p e F 5 , f o r fi x i n g resistors and condensers, M S fl a t s 2 5 m m x 6 m m brass bolts a n d nuts, paints, soldering materials, r e s i s t o r s , c o n d e n s e r s a n d a l l other miscellaneous materials required for the work shall be supplied by the contractor]. a)Wiring of Signal/ point/ LC control circuit (up to 4 relays/Plug in type) | Set | 5.00 | 4,945.51 | 24,727.55 |
| 28 | Manufacture and supply o f M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug i n type a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing o f p l u g b o a r d s , r e l a y s , r e s i s t o r s and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram a n d painting the particulars.[Wire P V C copper, 3/0.75mm and 1 6 / 0 . 2 m m c o p p e r , P h y n o l i c synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1 9 9 5 - Ty p e F 5 , f o r fi x i n g resistors and condensers, M S fl a t s 2 5 m m x 6 m m brass bolts a n d nuts, paints, soldering materials, r e s i s t o r s , c o n d e n s e r s a n d a l l other miscellaneous materials required for the work shall be supplied by the contractor]. b)Wiring o f Signal/ Point/ L C control circuit (up to 8 relays/plug in type) | Set | 10.00 | 8,786.26 | 87,862.6 |
| 29 | Manufacture and supply o f M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug i n type a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing o f p l u g b o a r d s , r e l a y s , r e s i s t o r s and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram a n d painting the particulars.[Wire P V C copper, 3/0.75mm and 1 6 / 0 . 2 m m c o p p e r , P h y n o l i c synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1 9 9 5 - Ty p e F 5 , f o r fi x i n g resistors and condensers, M S fl a t s 2 5 m m x 6 m m brass bolts a n d nuts, paints, soldering materials, r e s i s t o r s , c o n d e n s e r s a n d a l l other miscellaneous materials required for the work shall be supplied by the contractor]. c)Wiring o f Signal/ Point/ L C control circuit (up to 12 relays/plug in type) | Set | 5.00 | 11,355.02 | 56,775.1 |
| 30 | Manufacture and supply o f M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug i n type a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing o f p l u g b o a r d s , r e l a y s , r e s i s t o r s and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram a n d painting the particulars.[Wire P V C copper, 3/0.75mm and 1 6 / 0 . 2 m m c o p p e r , P h y n o l i c synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1 9 9 5 - Ty p e F 5 , f o r fi x i n g resistors and condensers, M S fl a t s 2 5 m m x 6 m m brass bolts a n d nuts, paints, soldering materials, r e s i s t o r s , c o n d e n s e r s a n d a l l other miscellaneous materials required for the work shall be supplied by the contractor]. d)Wiring o f Signal/ Point/ L C control circuit (up to 20 relays/Plug in type) | Set | 10.00 | 13,597.41 | 1,35,974.1 |
| 31 | Fixing o f PBT terminal block/ PBT fuse block, rubber grommets, clamping of cables using teakwood c a b l e c l a m p s a n d base planks, termination o f cables, provision of ND type f u s e s o f required capacities, provision of copper b u s b a r f o r supply terminals, wiring, provision o f termination particulars diagram board using plywood of thickness 1 2 m m - teakwood finish o f size 1800mm x 1200mm with Aluminium grooved channel frame in the relay room. The blank spaces over the top of the cable termination rack shall b e covered with phynolic s h e e t o f t h i c k n e s s 3mm wherever required. The termination and cable core particulars shall b e painted o n the PVC/ n y l o n s l e e v e s . T h e w o r k a l s o includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply of PBT terminal blocks 25mm & 6 0 m m centers a n d P B T Fu s e blocks i s not covered in the schedule) [Wire PVC 3/0.75mm copper, brass bolts and nuts and washers, for fixing PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 50mm x 50mm for cable clamps, 25mmx 100mm for base planks, phynolic sheet 6mm thick of size 1200mm x 1800mm with aluminium grooved channel frame, phynolic s h e e t 3 m m thick, paint a n d a l l other miscellaneous materials shall be supplied by the Contractor]. a)Fixing of PBT terminal blocks (25mm/60mm centre) and termination (Per Unit = Per Terminal Block) | Per Unit | 150.00 | 167.99 | 25,198.5 |
| 32 | Fixing o f PBT terminal block/ PBT fuse block, rubber grommets, clamping of cables using teakwood c a b l e c l a m p s a n d base planks, termination o f cables, provision of ND type f u s e s o f required capacities, provision of copper b u s b a r f o r supply terminals, wiring, provision o f termination particulars diagram board using plywood of thickness 1 2 m m - teakwood finish o f size 1800mm x 1200mm with Aluminium grooved channel frame in the relay room. The blank spaces over the top of the cable termination rack shall b e covered with phynolic s h e e t o f t h i c k n e s s 3mm wherever required. The termination and cable core particulars shall b e painted o n the PVC/ n y l o n s l e e v e s . T h e w o r k a l s o includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply of PBT terminal blocks 25mm & 6 0 m m centers a n d P B T Fu s e blocks i s not covered in the schedule) [Wire PVC 3/0.75mm copper, brass bolts and nuts and washers, for fixing PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 50mm x 50mm for cable clamps, 25mmx 100mm for base planks, phynolic sheet 6mm thick of size 1200mm x 1800mm with aluminium grooved channel frame, phynolic s h e e t 3 m m thick, paint a n d a l l other miscellaneous materials shall be supplied by the Contractor]. b)Termination using P B T fuse block i n cable termination rack (Per Unit = Per Fuse Block) | Per Unit | 25.00 | 201.27 | 5,031.75 |
| 33 | Fixing o f additional p l u g boards, 5 0 ways terminal blocks and wiring of additional relays as per the approved circuit diagram using wire PVC 16/0.2mm copper. Additional wire supporting tray with cover made of PVC shall be provided wherever required. Alterations to Relay particulars shall be incorporated in the relay Index board.(Supply o f r e l a y s , plug boards, connectors and retaining clips and 50 w a y terminal boards i s n o t covered i n this schedule).[Wire PVC 16/0.2mm copper, 2 BA terminals, teakwood plank 2 5 m m t h i c k for fi x i n g resistors a n d condensers, soldering materials, b u n c h i n g t h r e a d , w i r e wound resistance, condenser, w i r e supporting tray with cover of suitable size made of PVC, paint, varnish and a l l other miscellaneousmaterials required for the work shall be supplied by the Contractor ] | Per Relay | 50.00 | 726.5 | 36,325 |
| 34 | Carrying out alterations to the existing relays in the relay racks/apparatus cases as per the approved circuit diagram using wire PVC 16/0.2mm copper. The work includes painting alterations and releasing the unwanted wires c a r e f u lly w i t h o u t disturbing the existing wiring.[Wire PVC 16/0.2mm copper, soldering materials, b u n c h i n g t h r e a d s , condensers, resistances a n d teakwood p l a n k f o r fixing the m a n d a l l other miscellaneous materials required for the work shall be supplied by the Contractor]. | Per Relay | 1250.00 | 695.67 | 8,69,587.5 |
| 35 | Supply of Block Filter Unit used in conjunction w i t h b l o c k instrument i n 25KV, 50Hz AC traction area as per specification No IRS:S- 68/89 including latest amendment | Numbers | 12.00 | 18,161.86 | 2,17,942.32 |
| 36 | Supply and laying of PVC Warning Tape colour Orange, width o f 250mm (10") by printing w i t h b l a c k l e t t e r s 'Indian RailwaySignal/Telecom/OFC Cable' on both sides | Metre | 6000.00 | 46.15 | 2,76,900 |
| 37 | Supply of HDPE Pipe 40mm (outer dia)/33 mm (inner dia) with couplers | Metre | 4000.00 | 60.93 | 2,43,720 |
| 38 | S u p p l y a n d I n s t a l l a t i o n o f Wall/Rack mountable 2 4 Fi b r e management system ( F M S ) conforming t o RDSO/SPN/TC- 37/2000(rev-3 a m d t - 1 o r l a t e s t sim ila r to COMMSCOPE m a k e o r better, suitable for splicing and front patching 24F cable with all accessories and terminating the optical fibre cable with splicing and front patching in FMS in the Location Box. This includes Supply and Provision of 4 nos of Patch cords of required l e n g t h ( A l l o t h e r m a t e r ia ls r e q u i r e d for splicing are to be supplied by contractor ) | Numbers | 10.00 | 18,686.74 | 1,86,867.4 |
| 39 | Supply of Track Feed Resistance | Numbers | 500.00 | 287.77 | 1,43,885 |
| 40 | Supply of ND Fuse of various capacities (Per unit=Per fuse) | Per Unit | 3000.00 | 37.74 | 1,13,220 |
| 41 | Painting of existing colour light Signals as per standard practice. The work involves scraping o f old paint, applying one coat of Red oxide and two coats of Aluminium/ enamel paint on t h e Signa ls - complete as instructed by Railway representative at site.[Aluminium paint, red-oxide a n d a l l other miscellaneous materials required f o r the work shall be supplied by the Contractor]. | Numbers | 800.00 | 2,442 | 19,53,600 |
| 42 | Releasing of existing tail cables and drawl of new tail cables for colour light signals up to four aspects with o r without route indicator, post type shunt signal and Calling on signals, termination o f n e w t a i l cables and wiring using wire P V C 3/0.75mm copper. This work includes drawl of new tail cables into the signal post duly releasing the existing tail cables from the relevant signals and re- surfacing t h e earth excavated as instructed by Railway representative at site. [Wire PVC 3/0.75mm copper, paints and all other miscellaneous materials shall be supplied by the Contractor]. | Per Unit | 100.00 | 1,524.86 | 1,52,486 |
| 43 | Painting o f existing b o a r d s l i k e LEGEND boards, warning boards, STOP boards etc., as p e r s t a n d a r d p r a c t i c e a n d a s p e r the instructions of Railway representative at site. (Supply o f b o a r d s i s n o t included i n this schedule).[Paint and all other miscellaneous materials required f o r t h e w o r k s h a l l be supplied by the Contractor]. | Numbers | 260.00 | 1,262.63 | 3,28,283.8 |
| 44 | " E x c a v a t i o n o f pit, casting concrete foundation and erection of apparatus case half size as per Drg, No.SG/CN/02/7, fixing one 'E' t y p e l o c k f o r t h e f r o n t d o o r and latching arrangement for the back door, and fixing of o n e hardwood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts and nuts, cement, 'E' type locks, M sand, stone jelly of size 20/25mm,37mm hard wood planks, latching ""arrangements, paints, varnish, fixing bolts & nuts and all other miscellaneous materials required f o r t h e w o r k s h a l l be supplied by the Contractor]""" | Numbers | 20.00 | 8,787.04 | 1,75,740.8 |
| 45 | Termination o f n e w main/tail cables o n the existing terminals/ fuse blocks in apparatus c a s e s / b a t t e r y b o x e s / C T b o x e s / cable termination r a c k s a s p e r approved circuit diagram. T h e terminal particulars a r e to be r e p a i n t e d / c o r r e c t e d o n t h e d o o r s of a p p a r a t u s c a s e s / b a t t e r y b o x e s / cable termination boxes and FTOT index board as instructed by Railway representative at site. T h i s w o r k i n c l u d e s c l o s i n g t h e opening create d f o r e n t r y o f n e w c a b l e s i n the apparatus cases with masonry brick work and sealing t h e bottom o f t h e apparatus cases/ cable termination racks with cable compound. [Paints, wire PVC 3/0.75mm and 16/0.2mm copper, sealing compound, bricks, cement, M sand and all other required miscellaneous materials shall be supplied by the contractor]. (Per Unit = Per Terminal block) | Per Unit | 1500.00 | 73.59 | 1,10,385 |
| 46 | Termination of main, tail, Signaling and power cables a n d internal wiring on terminal/ fuse b l o c k s i n n e w apparatus cases, cable termination b o x e s a n d i n gate Lodges excluding c a b l e termination r a c k at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing o f Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm t h i c k for terminal board to suit each apparatus c a s e , varnishing all teakwood items, fixing o f terminals/ fuse blocks o n the terminal board, drilling of necessary holes, termination of cables, wiring, identification of c a b l e s using aluminium tags with letters punched neatly, as p e r approved circuit d i a g r a m a n d cable plan, p a i n t i n g of particulars o n sleeves andalso o n t h e inner side o f t h e doors of apparatus cases. After terminations are "over, t h e side openings of apparatus case foundation s h a l l b e closed with brick work, cement plastered, the inter- space filled with M sand up to base level and t h e bottom surface s h a l l b e s e a l e d with sealing compound.(Supply of PBT terminals and Fuse blocks is not c o v e r e d i n this schedule)." a)Termination o n 25/60mm PBT terminals (new location)(Phynolic sheet)(Per Unit = Per Terminal block) | Per Unit | 1250.00 | 172.14 | 2,15,175 |
| 47 | Termination of main, tail, Signaling and power cables a n d internal wiring on terminal/ fuse b l o c k s i n n e w apparatus cases, cable termination b o x e s a n d i n gate Lodges excluding c a b l e termination r a c k at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing o f Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm t h i c k for terminal board to suit each apparatus c a s e , varnishing all teakwood items, fixing o f terminals/ fuse blocks o n the terminal board, drilling of necessary holes, termination of cables, wiring, identification of c a b l e s using aluminium tags with letters punched neatly, as p e r approved circuit d i a g r a m a n d cable plan, p a i n t i n g of particulars o n sleeves andalso o n t h e inner side o f t h e doors of apparatus cases. After terminations are "over, t h e side openings of apparatus case foundation s h a l l b e closed with brick work, cement plastered, the inter- space filled with M sand up to base level and t h e bottom surface s h a l l b e s e a l e d with sealing compound.(Supply of PBT terminals and Fuse blocks is not c o v e r e d i n this schedule)." b)Termination o n P B T fuse block (new location) (Phynolic sheet)(Per Unit = Per Fuse block) | Per Unit | 50.00 | 209.93 | 10,496.5 |
| 48 | Termination of main, tail, Signaling and power cables and internal wiring by fixing additional terminals/ fuse blocks on the existing terminal boards of apparatus cases, cable termination boxes etc. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, o n t h e existing terminal boards, drilling o f necessary holes, termination of cables, wiring, identification of c a b l e s using aluminium tags with letters punched neatly, as p e r approved circuit d i a g r a m a n d cable plan, p a i n t i n g of particulars o n sleeves and also o n t h e inner side o f t h e doors of apparatus cases. After terminations are over, t h e side openings of apparatus case foundation s h a l l b e closed with brick work, cement plastered, the inter- space filled with M sand up to base level and t h e bottom surface s h a l l b e s e a l e d with sealing compound. a)Termination of cables on 25/60mm PBT terminals (existing location) (Per Unit = Per Terminal block) | Per Unit | 1250.00 | 151.09 | 1,88,862.5 |
| 49 | Termination of main, tail, Signaling and power cables and internal wiring by fixing additional terminals/ fuse blocks on the existing terminal boards of apparatus cases, cable termination boxes etc. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, o n t h e existing terminal boards, drilling o f necessary holes, termination of cables, wiring, identification of c a b l e s using aluminium tags with letters punched neatly, as p e r approved circuit d i a g r a m a n d cable plan, p a i n t i n g of particulars o n sleeves and also o n t h e inner side o f t h e doors of apparatus cases. After terminations are over, t h e side openings of apparatus case foundation s h a l l b e closed with brick work, cement plastered, the inter- space filled with M sand up to base level and t h e bottom surface s h a l l b e s e a l e d with sealing compound. b)Termination of cables on PBT fuse block (existing location)(Per Unit = Per Fuse block) | Per Unit | 25.00 | 188.86 | 4,721.5 |
| 50 | "Painting of existing apparatus case (Outside) - Full size" | Numbers | 2350.00 | 1,182.15 | 27,78,052.5 |
| 51 | "Painting of existing apparatus case (Outside) - Half size" | Numbers | 1450.00 | 1,132.2 | 16,41,690 |
| 52 | Provision of HDPE Pipe of dia 40/33 mm | Metre | 4000.00 | 26.11 | 1,04,440 |
| 53 | Laying o f DWC/Split D W C P i p e s f o r Track Crossing/Road Cutting/Trenches | Metre | 6000.00 | 42.46 | 2,54,760 |
| 54 | Releasing o f existing apparatus cases (Full/ H a l f / Q uarte r s i z e ) w itho ut d a m a g e after releasing the shelf planks, Terminal blocks, Fuse Blocks, Terminal Boards, Relays o f all t y p e s E K T s , S e c o n d a r y Cells, power equipments, 'E' type locks, etc., and breaking the concrete foundation. After releasing, the resultant pits are to be closed and consolidated by ramming and levelling. The released materials shall b e accounted and stacked a t a place a s instructed by Railway representative at site. | Numbers | 200.00 | 3,006.71 | 6,01,342 |
| 55 | Providing the services of Computer oriented technical manpower t o carryout w o r k s like Drawing, computation, w rite up e t c . , using computer, using software like AUTOCAD, MS O ffi c e etc., f o r 08.00 h r s i n a d a y w i t h all expenses of transportation, accommodation, f o o d , consumables e t c . , w i t h a l l ascents, descents, taxes, octroi, c e s s , f e e s , duties, d u t i e s w i t h contractors c o s t e t c . , a s per special conditions/ specifications/ regulations and as directed by Engineer-in-charge. Note: The person engaged for providing the services shall b e convergent w ith computer working knowledge in above software. | Man- Days | 60.00 | 913.28 | 54,796.8 |
| 56 | Protection adjustments a n d re-instating of S&T gears by deputation of Helpers/Unskilled Labour for executing additional S&T portion of t h e w o r k s . The work can involve fixing, releasing, dismantling, replacement,excavation, clearing of vegetation, loading and unloadingof material and assisting skilled persons etc as per instruction of Railway representative. | Man- Days | 100.00 | 847.59 | 84,759 |
| 57 | Protection, adjustment and reinstating of S&T g e a r s b y d e p u t a t i o n of Fitter/Wireman/Painter/Welder/ Mason/Cable Jointer (Skilled Labour or Technician ) etc., for executing additional S&T portion of works. The w o r k c a n i n v o l v e fixing, releasing, dismantling, replacement, painting or alteration o f vario us signallilng assets or parts, termination of cables, minor patch work on damages at location box, Plastering, Concreting b r i c k w o r k , w i r i n g alterations, cable jointing etc as per instruction of Railway representatives at size. | Man- Days | 50.00 | 1,073.45 | 53,672.5 |
| 58 | Transportation of Signalling materials by road a s p e r t h e i n s t r u c t i o n s o f Railway representative at site. The work also includes l o a d i n g a n d u n lo a d in g o f the materials a)Transportation o f Signalling materials upto 100kms | MT-Km | 2000.00 | 22.75 | 45,500 |
| 59 | Transportation o f Signalling materials more than 100km | MT-Km | 1000.00 | 13.91 | 13,910 |
| 60 | Engaging mechanical excavators like JCB or other machineries for regarding and levelling t h e formation, dismantling a n y infringing structures, clearing and removing debris etc., with all leads and lifts etc., complete and as per the instruction o f Railway representative at site. | Hour | 20.00 | 1,202.5 | 24,050 |
| Schedule total | ₹1,54,76,422.38 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderDocumentOT72025.pdf Special Condition
ATTACHMENT
Tenderdocument1_1_2.pdf
ATTACHMENT
I_CT_GCC-
ATTACHMENT
ACS110.pdf
ATTACHMENT
LetterofCreditRBLr_1.pdf
ATTACHMENT
JPODETAILS.pdf
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27.04.22.pdf
ATTACHMENT
TenderDocumentOT72025.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .