Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.4 LAccepted-AOC 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | L1 | Accepted-AOC DUE TO L1 | |
| 2 | L2₹20.7 L+₹1.7 L (9.20%)Rejected-Finance RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L2 | Rejected-Finance HIGHER RATE | |
| 3 | Rejected-Technical 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | - | Rejected-Technical Rejected due to valid compentency certificate of two (02) AC Mechanics each having minimum working experience of 02 years in the filed of Air Conditioning has not found | |
| 4 | Rejected-Technical RZ 1 7 167 GALI NO 6 DURGA PARK NASIRPUR SOUTH WEST DELHI DELHI 110045 | SOUTH WEST | DELHI | 110045 | - | Rejected-Technical Rejected due to valid compentency certificate of two (02) AC Mechanics each having minimum working experience of 02 years in the filed of Air Conditioning has not found |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
6 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NEW DELHI
GE NEW DELHI, SP MARG NAR ABHM GATE NO 5
REPAIR/ MAINT OF WINDOW/ SPLIT/ CASSETTE TYPE ACs AND ITS CONNECTED ACCESSORIES AT KASHMIR HOUSE UNDER GE NEW DELHI
2024_MES_653117_1
NIT No GE/ND-11/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE NEW DELHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE NEW DELHI
₹40,000
Yes
6 Jul 2024
9 May 2024
13 Jun 2024
9 May 2024
6 Jun 2024
24 May 2024
Amount
Labour for checking and attending complants of ACs, Refrigerators etc of any capacity, rectification minor defects and make the equipment functional complete all as specified and directed. Note: any parts required for replacement shall be measured and paid separately under respective items Note:- (a) The contractor should detail minimum one AC Mechanic & one helper to attend complaints in kashmir House and he must submit copy of valid competency certificate of two(2) AC mechanics each having minium working experience of two years in the field of air conditioning & refrigeration. The certificate should be issued by the OEM only stating the technical qualification & experience of the mechanics to be deployed, faling which the bid of the contractor is liable to be rejected. (b) The complaint should be attended on same day within 3 hours . (c) If the complaint not attended/not completed on same day within three hours recovery will be done as follows:- (i) For first day Rs.500/- (ii) For second day Rs.800/- (iii) For next every day Rs.1000/-
Servicing of Window type AC 1.5/2 Ton capacity of any make / model by taking out the AC, Cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of AC complete all as specified and directed.
All as per item No 2 above but Split type AC of any type and 1.5/2 Ton capacity complete all as specified and directed.
Servicing of cassette /tower type split AC 3.5 to 4.0 Ton capacity of any make / model with indoor and outdoor unit by taking out the AC, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of AC complete all as specified and directed. Note: Unserviceable spares parts required to be replaced shall be measured and paid separately under respective items.
Supply only running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 Volt for AC upto 4.00 Ton complete all as specified and directed.
Supply only Running capacitor 6 mfd 230 volt complete all as specified and directed.
Supply only Running capacitor 4 mfd 230 volt complete all as specified and directed.
Supply & charging gas refrigerant R-22 /410 A/ or as existing to window type/Split type/Cassette/Package type AC up to 4 Ton capacity including removing of leakage if any and testing complete all as specified & directed by Engineer-in-charge
Supply only starting relay suitable for 1.5/2 Ton capacity AC complete all as specified and directed.
Supply only over load protector suitable for 1.5/2 Ton capacity AC complete all as specified and directed.
Supply only thermostat switch suitable for 1.5/2 Ton capacity AC complete all as specified and directed.
Supply only starting relay suitable for 4.0 Ton capacity AC complete all as specified and directed.
Supply only over load protector suitable for 4.0 Ton capacity AC complete all as specified and directed.
Supply only thermostat switch suitable for 4.0 Ton capacity AC complete all as specified and directed.
Supply only cordless Remote for inverter type ACs Hot & cool suitable for 1.5 Ton AC as per sample complete all as specified and directed.
Supply only cordless Remote for ACs suitable for 1.5/2 ton split/window AC as per sample complete all as specified and directed.
Supply and fixing in replacement reciprocating /Rotary type compressor suitable for 1.5 to 2.0 Ton capacity split type AC of the same make and model as per existing make of ACs, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed.
Supply and fixing in replacement reciprocating/Rotary type compressor suitable for 1.5 to 2 Ton capacity window type AC of the same make and model as per existing make of ACs, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed.
Supply and fixing in replacement any type of compressor suitable for Inverter type 1.5 to 2 Ton capacity split AC of the same make and model as per existing make of ACs, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed.
Supply and fixing in replacement of three phase compressor suitable for 3.5 to 4.0 Ton capacity suitable of cassete /tower AC of the same make and model as per existing make of ACs complete all as specified and directed.
Supply only in replacement air filter synthetic/ nylon as per existing size and shape suitable for 1.5/2 Ton capacity window type Acs complete all as specified and directed.
Supply only in replacement air filter synthetic/ nylon as per existing size and shape suitable for 1.5/2 Ton capacity split type AC's complete all as specified and directed.
Supply only in replacement air filter synthetic / nylon type as per existing size and shape suitable for 3.5/4.0 Ton capacity cassette type split AC's complete all as specified and directed.
Supply only in replacement new fan motor (inoor/outoor) 1/4,1/5 HP single/double shaft as per existing model sutaible for Split type ACs 1.5/2 Ton complete all as specified and directed.
Supply only in replacement new DC fan motor (inoor/outoor) 1/4,1/5 HP single/double shaft as per existing model sutaible for Split type ACs 1.5/2 Ton complete all as specified and directed.
Supply only in replacement fan motor single/double shaft as per existing model suitable for 3.5/4.0 Ton AC's of any make/type complete as per requirement on site complete all as specified and directed.
Supply only in replacement new DC fan motor single/double shaft as per existing model suitable for 3.5/4.0 Ton cassatte type AC's of any make/type complete as per requirement on site complete all as specified and directed.
M & L for rewinding of fan motor suitable for ACs up to 4 Ton capacity with super enameled copper winding wire of same gauge including replacement of insulating material, bushes and shaft complete all as specified and directed.
Supply only in replacement condensor fan blade made out of aluminium /plastic suitable for upto 2 Ton capacity window type Acs complete all as specified and directed.
Supply only in replacement of condensor fan blade made out of aluminium /plastic suitable for upto 2 Ton capacity split type Acs complete all as specified and directed.
Supply only in replacement of condensor fan blade made out of aluminium /plastic suitable for upto 4.0 Ton capacity cassette type complete all as specified & directed.
Supply only in replacement of evaporating air blower made out of aluminium /plastic suitable for upto 2 Ton capacity for window type AC complete all as specified and directed.
Supply only in replacement of evaporating air blower made out of aluminium /plastic suitable for upto 2 Ton capacity for split type AC complete all as specified and directed.
Supply only in replacement of indoor air blower made out of aluminium /plastic suitable for upto 4.0 Ton capacity type complete all as specified & directed.
Supply only in replacement air direction changer louver motor ( swing motor) suitable for split type ACs as per existing make and model complete all as specified and directed.
Supply only in replacement PVC insulated flexible copper conductor 3 core 1100V Grade of size 2.5 sqmm complete all as specified and directed.
Supply only in replacement PVC insulated flexible copper conductor 3 core 1100V Grade of size 4.0 sqmm complete all as specified and directed.
Supply only in replacement of synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split AC units complete all as specified and directed.
Supply only in replacement of synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split AC units complete all as specified and directed.
Supply only in replacement of synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9 mm ("3/8") for refrigerant copper piping of split AC units complete all as specified and directed. Make:- Supreme/Gulf-o-flex/Superlon.
Supply only in replacement of synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16 mm ("5/8") for refrigerant copper piping of split AC units complete all as specified and directed. Make:- Supreme/Gulf-o-flex/Superlon.
M & L for replacement of front grill suitable for window type ACs upto 2 Ton capacity of any Make as per existing size and shape complete all as specified and directed.
M & L for replacement of reverse valve system suitable to 1.5/2 Ton split/window AC for heating option complete all as specified and directed. Make: Gas charging shall be paid and measured under respective item
Supply only copper tubing heavy duty inner dia 6 mm (1/4") for refrigerant for Acs complete all as specified and directed. Make-Mandev/Mandley/ Uniflow
Supply only copper tubing heavy duty inner dia 13mm (1/2") for refrigerant for Acs complete all as specified and directed.
Supply only copper tubing heavy duty inner dia 9 mm (3/8") for refrigerant for Acs complete all as specified and directed.
Supply only copper tubing heavy duty inner dia 16 mm (5/8") for refrigerant for Acs complete all as specified and directed.
Supply only condensing coil suitable for 1.5/2 Ton split/window type ACs as per existing size/shape and as per existing make complete all as specified and directed.
Supply only evaporating coil suitable for 1.5/2 Ton split/window type ACs as per existing size/shape and as per existing make complete all as specified and directed.
M&L for checking the leakage by feeding dry Nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas R-12/22/134a for water cooler, Split type/Window type AC/ Deep Freezer /Refrigerator any size any capacity as on site complete all as specified and directed by Engr-in-Charge.
Supply only brass flare nut/connector heavy duty of size 6 mm/9 mm (1/4", 1/2") as per existing size complete all as specified and directed.
Repair to control processing board( Remote control kit) with hand set including replacement of current transformer, ICs, dieods, resistances, sensors etc complete for 1.5/2 Ton split type ACs of any make & model complete all as specified and directed.
Repair to control processing board( Remote control kit) inverter type with hand set including replacement of current transformer, ICs, dieods, resistances, sensors etc complete for 3.5/4 Ton cassette type ACs of any make & model complete all as specified and directed.
M&L for replacement of unserviceable display along with PCB suitable for NON inverter Split type AC 1.5/2 TR with new PCB along with display unit complete all as specified and directed. Make-Hitachi/Voltas/Carrier/Daikin
M&L for opening and taking down existing unserviceable PCB along with display unit and fixing of new PCB along with display unit suitable for Indoor unit of Inverter AC of capacity1.5/2 Ton split type AC complete all as specified and directed by Engr-in-Charge.
M&L for opening and taking down existing unsv PCB and fixing of new PCB suitable for Outdoor unit of 1.5/2 Ton split type AC inverter AC complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement split type AC 1.5/2 Ton indoor unit kit with PCB complete with sensor complete with fixing plate suitable to non inverter type AC complete all as specified and directed.
Supply and fixing in replacement split type AC 1.5/2 Ton indoor PCB unit kit complete with sensor complete with fixing plate suitable to inverter type model and make AC complete all as specified and directed.
Supply and fixing in replacement split type AC 1.5/2 Ton outdoor unit kit complete with compressor,condensor coil, condensor fan with blade and sensor suitable to non inverter type existing model and make AC complete all as specified and directed.
Supply and fixing in replacement split type AC 1.5/2 Ton outdoor unit kit complete with compressor, condensor coil, condensor fan with blade and sensor suitable to inverter type existing model and make AC complete all as specified and directed.
Supply and fixing in replacement window AC kit 1.5/2 Ton PCB with sensor complete with condensing coil, fan motor, blower and motor, compressor and grill complete suitable to non inverter type existing model and make AC complete all as specified and directed.
Supply only in replacement voltage stablizer of capacity 3 to 5 KVA ,copper wounded made of metalic body complete all as specified and directed
Supply and fix in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 TR as per sample complete all as specified and directed.
M&L in replacement Metal Clad Plug & socket board SP&N enclosure with single pole and earth metal plug & socket suitable for 20 Amps MCB AC, 220 V, 50Hz complete all as specified and directed.
M&L in replacement modular AC board SP&N enclosure with single pole and earth metal plug & socket suitable for 20 Amps MCB AC, 220 V, 50Hz complete all as specified and directed.
S&F in replacement of plug top 3 pin, 15 Amps, 230 volts, 50 Hz AC complete all as specified and directed.
Taking down AC of any type, any capacity and any make, dismantling of copper pipe, transportation to work shop for carrying out necessary repair work, transportation back to location of installation , reinstallation/refixing in position after complete repairs as required and making functional including testing complete all as specified and directed.
M&L for taking down Split/Window AC and shifting from one position to other within te premises Complete with copper tubing indoor plate and copper tubing complete with all accessories with making good the disturbed surfaces with cement plaster and POP Complete all as specified and as directed by Engr-in-Charge.
M & L for making suitable hole in the wall to fix window or split AC and maintain the surface as per existing condition complete all as pecified and directed. Note : (a) plastering ,putty ,painting includede in the quoted rate (b) covering the window by ply if nececssary also included in the quoted rate
Supply only in replacement wall stand /chauki stand fastener upto 8mm size to fix outdoor of split/cassete ac made of metalic stell complete all as specified and directed.
RUCHIKA ENGG.WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .