Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 CrAccepted-AOC | ₹7.7 Cr Quoted ₹7.9 Cr | L1 | Accepted-AOC LOWEST |
| 2 | L2₹8.9 Cr+₹98.9 L (12.6%)Rejected-Finance | ₹8.9 Cr+₹98.9 L (12.6%) | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹9.5 Cr+₹1.6 Cr (20.3%)Rejected-Finance | ₹9.5 Cr+₹1.6 Cr (20.3%) | L3 | Rejected-Finance NOT LOWEST |
| 4 | L4₹9.6 Cr+₹1.8 Cr (22.5%)Rejected-Finance | ₹9.6 Cr+₹1.8 Cr (22.5%) | L4 | Rejected-Finance NOT LOWEST |
| 5 | L5₹9.8 Cr+₹2.0 Cr (24.8%)Rejected-Finance | ₹9.8 Cr+₹2.0 Cr (24.8%) | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹8.3 Cr
EMD Value
₹7.4 L
Closing Date
11 Dec 2019, 6:00 pmClosed
CE (AF) WAC PALAM, DELHI CANTT-10
HQ CE (AF) WAC PALAM, DELHI CANTT-10
RECONSTRUCTION/ADDN/ALTN OF AIRMEN MESS AND CERTAIN LIVING ACCOMODATION AT AF STATION ADAMPUR
2019_MES_264263_1
CEWAC/ADM/T-35/2019-20
Open Tender
Civil Works
Lump-sum
415 days
ADAMPUR
AS PER NIT
8 documents required · 8 mandatory
₹3,000
Yes
GE (AF) ADAMPUR
₹7.4 L
Yes
5 Mar 2020
3 Jul 2019
12 Dec 2019
3 Jul 2019
11 Dec 2019
5 Dec 2019
3 Jul 2019 - 18 Jul 2019
Amount
SCHEDULE `A' PART - I (Building Works) is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only.
Construction of Ors Single living accomodation (246 Qtrs) (G+2) with permanent specifications complete all as specefied as shown on drawings.
Construction of single living in Officers accomodation Flt Lt (12 Unit) (G+1) with permanent specifications complete all as specefied as shown on drawings.
Construction of Servant Qtrs with permanent specifications complete all as specified as shown on drawings.
Construction of Sub station Building with permanent specifications complete all as specified as shown on drawings.
Construction of garages with permanent specifications complete all as specified as shown on drawings.
NOTE: Schedule ‘A’ Part II to XIII under are Prepriced by MES.
Lump sum price worked out by the Contractor for “SITE CLEARANCE AND EARTH WORK” as listed in Schedule ‘A’ Part II
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION"” as listed in Schedule ‘A’ Part III
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part IV
Lump sum price worked out by the Contractor for "SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part V
Lump sum price worked out by the Contractor for “AREA DRAINAGE WORK” as listed in Schedule ‘A’ Part VI
Lump sum price worked out by the Contractor for “ROAD AND PATH " as listed in Schedule ‘A’ Part VII
Lump sum price worked out by the Contractor for “ADDITION/ ALTRETION TO AIR MEN MESS" as listed in Schedule ‘A’ PartVIII
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part-IX
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIC SUPPLY ” as listed in Schedule ‘A’ Part - X
Lump sum price worked out by the Contractor for “SOLAR WATER HEATING SYSTEM" as listed in Schedule ‘A’ Part XI
Lump sum price worked out by the Contractor for “REFRIGRATION & AIR CONDITIONING” as listed in Schedule ‘A’ Part XII
Lump sum price worked out by the Contractor for “DEMOLITION/DISMANTLING” as listed in Schedule ‘A’ Part XIII
SCHEDULE `A' PART - XIII MISC ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only.
INTERNAL ELECTRIFICATION
S&F LED bulb 09 watt complete all as specified and directed, complete all as specified and directed by Engineer-in-Charge. Make:Bajab/philips/Havells.
Supply and fixing ceiling fan 1200mm sweep 5 star rating complete including modular step up type fan regulator 230 volts (single phase) and provisioning of flexible copper cord of size 23/0.0076 of required length from ceiling rose or connector to ceiling fan for giving connection complete all as specified and as directed by Engineer-in-Charge.Make for Fan : Crompton/Bajaj/ Havells.
Supply and fixing metal frame body exhaust fan of size 300 mm sweep, 900 RPM 230 volts single phase AC supply with louvers complete with, bolt, nuts and washers, suitably embedded in the wall including making suitable opening and provisioning of flexible copper cord three core PVC sheathed of size 23/0.0076 from ceiling rose to exhaust fan for giving connection complete all as specified and directed. Make for Exh fan: Crompton/Bajaj/ Havells.
S&F energy saving decorative box type batten light fitting surface mounted complete with high efficiency PMMA diffuser soft glare free light LED lamp 20 watt suitable for 120 volts to 270 volts of system efficacy not less then 90 lumen/watt, with all accessories, pre-wired, including lamp and providing flexible copper wire, twin core cable complete all as specified and directed by Engineer-in-Charge.Make:- Crompton Greaves Cat Part No. DMLN1LT8-16 & LTT8-20 or equivalent in Philips/Bajaj/Havells.
S&F energy saving surface/recessed mounted decorative luminaire LED light fitting 36 Watt, 230 Volts suitable for 600x600 mm Modular/POP/Gypsum ceiling with high efficiency PMMA diffuser soft glare free light LED lamp suitable for 120 volts to 270 volts of system efficacy not less then 90 lumen/watt, with all accessories, pre-wired, including lamp and providing flexible copper wire, twin core cable complete all as specified and directed by Engineer-in-Charge.Make:- Crompton Greaves Cat Part No. LCTLS-36-CDL or equilent in Philips/ Bajaj/Havells.
S&F LED sleek mirror light fitting 10 watt provided with high output diffuser 2 ft long, 230 Volts complete with all accessories, pre-wired including lamp and providing flexible copper wire, three core cable PVC insulated sheathed complete all as specified and directed by Engineer-in-Charge. Cat No- HLB-03-10-CW-AL(HALONIX) or its equivalent in Bajaj/philips/Havells. or equivalant in Phillips/Havells/Osram.
Supply & Fixing LED security Flood light fitting 50 watt, having uniformaty ratio 0.25, high pressure die cast aluminium housing, heat resistant toughened glass with frame, IP66 protection complete with lamp & connected items and connection with suitable cable from ceiling rose to light fitting and fixing on GI pipe bracket made out of suitable dia GI pipe medium grade 1.2mtr long bent to shape and fixed on wall with flat iron clamps, nut, bolts washer etc all as specified and directed. Cat No- HLFLD-ML17-50-CWL(HALONIX) or its equivalent in Bajaj/philips/Havells. or equivalant in Phillips/Havells/Osram.
NOTE FOR ITEM N 3.05 TO 3.08 :- (i) For all types of LED fittings and luminaire should be same manufacturer. (ii) LM -79 & 80 cretificate for all light fittings shall be submitted by the contractor before fixing at site or taking payment against material.(iii) System efficacy should be more than 100 lummens / watt (d) CRI should be 80 (v) THD should be less than 20% (vi) PF should be more than 0.95
S&F sheet metal enclosures Vertical type doubledoor (VTPN) incomer, with Acrilic Door , cement spill protector For and outgoing with MCB Triple pole and neutral, 4 ways, IP-43 protection, with 100 Amps rated bus bar breaking capacity 25KA , 415 Volts complete all as specified and directed by Engineer-in-Charge. Make : Indoasian/Legrand/L&T
S&F sheet metal enclosures Vertical type doubledoor (VTPN) MCCB incomer, and outgoing with MCB Triple pole and neutral, 4 ways, IP-43 protection, with 200 Amps rated bus bar breaking capacity 25 ka, 415 Volts complete all as specified and directed by Engineer-in-Charge. Make : Indoasian/Legrand/L&T
S&F MCCB 3 pole, 415 Volt, 100 Amps with breaking capacity 25 KA complete all as specified and directed. Make : Indoasian/Legrand/L&T
S&F MCCB 3 pole, 415 Volt, fixed type 200 Amps with breaking capacity 25 KA complete all as specified and directed. Make : Indoasian/Legrand/L&T.
S & F MCB TPN 63 Amps, 16KA 240 volts 'C' series complete all as specified and directed
S & F MCB SP 6 to 32 amps, 10KA, 240 volts 'C' series complete all as specified and directed
S & F MCB TP 63 amps, 16KA, 440 volts 'C' series complete all as specified and directed
S & F MCB SPN 40 Amps, 10KA, 240 volts 'C' series complete all as specified and directed
S/F socket outlet modular type 6 amps 5 pin combined two module 230 volts complete all as specified and as directed.
S/F socket outlet modulor type 6 &16 Amp, 3 & 6 pin combined shuttered type 230volts complete all as specified and directed.
S&F switch modular type 1 way 6 A, one module 230 volts complete all as specified and as directed.
S&F switch modular type 2 way 6 A, one module 230 volts complete all as specified and as directed.
S&F bell push modular type 6 A, one module 230 volts complete all as specified and as directed.
S&F switch modular type 1 way 16 A, one module 230 volts complete all as specified and as directed.
M & L for sub main wiring with two single core FRLSH, PVC insulated, multi stranded, unsheathed copper conductor cable with size 10 Sqmm and drawing through & including Non metallic PVC rigid conduit concealed in wall including earth continuity conductor of size 10 Sqmm PVC insulated unsheathed multi stranded copper conductor cable with suitable size of PVC Conduit as per IS , Not less than 32 mm and connected to earth dolly to be drawn in concealed PVC conduit including connecting to main board complete all as specified and directed by Engineer-in-Charge. Note:- Two run of copper condutor phase and neutral and one run of same size earth wire including one run of PVC conduit with cutting chasing and pointing shall be measured as one unit length.)
M & L for sub main wiring with two single core FRLSH, PVC insulated, stranded, unsheathed copper conductor cable with size 06 Sqmm and drawing through & including Non metallic PVC rigid conduit concealed in wall including earth continuity conductor of size 06 Sqmm PVC insulated unsheathed multi stranded copper conductor cable with suitable size of PVC Conduit as per IS , Not less than 25 mm and connected to earth dolly to be drawn in concealed PVC conduit including connecting to main board complete all as specified and directed by Engineer-in-Charge. Note:- Two run of copper condutor phase and neutral and one run of same size earth wire including one run of PVC conduit with cutting chasing and pointing shall be measured as one unit length.)
S&F modular white cover plate with frame 2 module complete all as specified and as directed.
S&F modular white cover plate with frame 3 module complete all as specified and as directed.
S&F modular white cover plate with frame 4 module complete all as specified and as directed.
S&F modular white cover plate with frame 6 module complete all as specified and as directed.
S&F modular white cover plate with frame 8 module complete all as specified and as directed.
ADDITON/ ALTRETION
M&L 2 coat of exterior emulsion paint on face of column, chajja on new wall surface including putty and primer preparation.
S&F steel windows 1.25mm thick box type (primer coated) ERW hollow *P‘ section of size 60mmX25mm single rebate comprises of skeleton shutter ERW sec 50X20mm & 1mm thick & openable leaf consisting two nos sash bar of T section 20X3mm complete welded to frame incl cutting holes & making good dismanteled portion in PCC 1:2:4 type- B-l four nos for each window incl following:-a)Hold fast 150mm long 12mmX3mm made to shape-04nos each window b)Handle of Z section 20X25mm ,100mm long Olnos each leaf IVIS c)tower bolt 150mm long 02 nos each leaf d)Z sec 20X25mm ,100mm stopper-Olnos per leaf.
e)Cleat 55mm long of hollow square 15X20X63mm welded to hinges-OlNos per leaf . f)MS Box type hinges of size 75X12mm-02Nos per leaf Fabrication & fixing as per Drg No CE JZ/TD-06/07 Make/Manufacture by 1 M/S Tee Pee enterprises amritsar 2. M/S Ram fabricator 'P' Ltd Panchkula. Note Wire mesh and painting shall be measured and paid separately under appropriate item.
All as Item No. 4.02 & 4.03 herein before but glazed.
SOLAR WATER HEATING SYSTEM
Supply and fixing brass non return valve of size 20 mm dia bore including cutting of pipes and insertion of NRV ISI marked complete
GEYSER
Taking down of old unserviceable geyser any type along with connection pipe and fixing accessories and deposited to E/M store yard complete all as specified and directed.
Supply and fixing of electric storage water heateter (Geyser) of rated capacity 25 litres single phase 230 volt vertical type with having five statr rating , ISI mark including hanging of geyser on wall with the help of nut bolt with screw fasner with PCC work including hot & cold PVC connection and testing complete all as specified and directed by Engr in Chargeor Make- Havells/Crompton/Recold/Bajaj
REFRIGRATION & AIRCONDITIONING
Supply , installation and testing of hi wall mounted split type air conditioner unit alongwith indoor and out door system complete unit of five star rating and EER 3.2 of capacity 1.5 TR ,,with codrdless rermote unit ,single phase 220 Volt to 240 Volt 50 Hz with having in built air ioniser and plasma filter for better indoor air quality rotary compress , system and other connected fixing accessories including making of suitable hole on wall/ celind/ roof and duly fixed on wall/ celing/ roof with the help of factory mounting metalic stand and nut , bolt , screw fastener etc and also proving of suitable type / size of suction & delivery copper tubes pipe with insulating materials all as per required at site complete all as specified and directed by Engr - in Charge
Supply , installation and testing of voltage stabilizer of rated capacity 4 KVA for autiomatic operation , for single phase ,cooper wound ,wall ,mounted indoor type,naturally air cooled with digital display and out put voltage 220+-9% calibration accuracy -+3% & designed for input variation between 170 volt to 260 volt and duly fixed on wall with the help of factory mounting metalic stand and nut , bolt , screw fastener etc and also providing of suitable type / size of cooper cable connection complete all as specified and directed by Engr - in Charge
Supply , installation and testing of voltage stabilizer of rated capacity 3 KVA for autiomatic operation , for single phase ,cooper wound ,wall ,mounted indoor type,naturally air cooled with digital display and out put voltage 220+-9% calibration accuracy -+3% & designed for input variation between 170 volt to 260 volt and duly fixed on wall with the help of factory mounting metalic stand and nut , bolt , screw fastener etc and also providing of suitable type / size of cooper cable connectionc complete all as specified and directed by Engr - in Charge
EXTERNAL WATER SUPPLY
Taking down of old unserviceable gate / globe valve from existing pipe line of size 15/20 mm bore complete all as specified and directed.
Demolition of existing valve pit any size any type complete and taking out of old broken unserviceable accessories from valve pit with its connection and fixing accessories incl excavation works complete all as specified and directed.
M&L for boring of holes under road, pavement, hard standing, texi track by tenchless technology usign ultrasounding tenchnique of by manual machine method andincluding providing HDPE pipe 150mm dia suitable for 0.4 mpa working pressure etc for complete all as specified and directed by EIC.
M&L for construction of masonry valve pit of size 60x60x60cm internal dimensions including making excavtion adn earth work complete suitabelfor gatet valve 80/50/40 mm dia complete all as specified and shown on drawing including duly fixed alognwith 40x40x6 mm angle iron framewith MS cover plate 3 mm thick and locking arragement system and duly painted with two coats of sythetic enamel paint overa coat of red oxide primer complete all as specified and directed.
Supply, installation, testing and commisioning of self priming mono block pump set with motor of suitable rating capacity rating capacity 3 HP three phase 415 volt AC supply 1500 rpm with having sync spped, CI impeller, shaft, glaned packing sealing complete al as per pump model No SP2HM of make Kirloskar Brothers Ltd or equivent specification and model of other mentioned CA make complete set including providing of suction and delivery pipe line attachement system complete all as specified and directed.
Supply, installed, testing and commissioing of floor mounted tpye new LT distrucbution panel board cubricfal shape out door type factory fabricated made out 3.15 mm thick mild steel sheet with epoxy powdercoated and CPRI approved including totally enclosed weather, dust & vermin proof having both sides double door system and fabricated with MS hinges, clamp, nut & bolt or drilling, bending and welding hot & cold etc and including necessary louvers, gasket, air vent and opening with locking arrangment on front side door system suitbale for 3 phase 4 wire 415 volt 50hz AC supply system including consisting of nos of required incoming/ outgoing feeder/ compartments with mounting channel alongwith suitbale curret rating sub distribution bus bar based on load with PVC colour heatshinkable
sleeve as per phase wised sequence including providng of digital type one volt meter and three nos of amps meter, with four nos of rotary slector switch, stauible CTratio , three phase RYB LED indicator lamp set alongwith three nos of motor start stop push botton with its LED indication lamp and internal control wiring for each contractors with multi stranded copper wire, danger ntoice board, cable grand, earth terminal poitn etc including providng of comprissing of following mentioned nos of all controlling fixing accessories complete. the panel board should be fitted on agle iron complete bottom base frame of size 40x40x6 mm and 75 cm height including grounted in PCC plate from with all fixing accessories all as specified and directed by Engr-in-charge Note :- The LT panel board drawing and details data of panel and its fixing item accessories shall be approved by GE before execution of work/fabrication of LT panel board work at factory
(a) MCCB of rating capacity 63 Amps 4 pole 25 KA 415 volts with adjustabel termal and fixed megneticseting type -01 make-Havelles/ABB/Legrand . (b) MCCB of rating capacity 20 Amps 3 pole 10 KA 415 volts with adjustabel termal and fixed megneticseting type -03 Nos make-Havelles/ABB/Legrand. . (c) Power contractor MNX series type 3 pole suitable for operating of automatically phase sequence correction/phases reversed purposed including providing of 02 Nos if MNX 25 Amp3 pole contractors with AE coil, alongwith suitable rating phase correction relay NO/NC type including all inter connection wiring connection work-01 No set , DOL starter suitable for the capacity of 3 HP moto, 3 Phase AC supply - 03 Nos, complete all as specified and diirected by EIC Make-Havelles/ABB/Siemens/L&T/BCH
(d) Power contractor MNX series type 3 pole suitable for operating of motor on & off sytem position purposed including including providing of 12 Nos if MNX 12Amp3 pole contractors with AE coil, alongwith suitable rating phase correction relay NO/NC type including all inter connection wiring connection work-03 Nos set complete all as specified and diirected by EIC Make-Havelles/ABB/Siemens/L&T/BCH. (e) Single phasing preventor having system AC aux supply 415 Volt AC 50 HZ of type/modle VSP-2 of VSP3 type compelte - 03 Nos of Nake - Mnilec/L&T/Bentex
EXTERNAL ELECTRIFICATION
Taking out old u/s LT under ground cable of sizes upto 120 Sqmm and removed from site complete all as specified and directed.
Taking out old u/s LT/HT bus bar/ panel of different sizes with enclosure and removed from site complete all as specified and directed.
Supply installation, testing and commissioning of Main Lt panel board CPRI approved power coated indoor type suitable for 3 phase 415 volts 04 Nos of copper bus bar of rating 600 amps dust weather and vermin proof made of 2mm CRCA mid steel sheet glands locking arrangement and angle iron frame and logs of 90cm long using 60x60x6mm size MS angel iron fixed in floor in PCC 1:4:8 type D2 base of appropriate size including necessary escavation earth work complete all as specified and directed and comprising of following: a) Incoming: i) MCCB 400Amps 4 pole 50KA-01 Nos ii)Digital volt meter 0 to 500 volt -01 Nos iii) Digital amp meter 0 to 600 amps-01 Nos iv) LED indicator set - 01Nos b)Out going: i) MCCB 4 pole 200Amp 35KA-01 Nos ii) MCCB 4 Pole 100 Amb 25 KA- 06 Nos
Supply fixing installation and cmoomissioning of LT panel borad manufactured by CPRI approved, outdoor type floor mounted, factory made suitable for 3 phase 415 volts copper bus bar duly insulated by insulation of RYB colur 300 Amps rating mounted on procelain insulators. The panel shall be factory made double door made out of 3.15mm thick MS sheet (CRCA) totally enclosed dust verinin and rust proof frost operated front and rear opeining with locking arrangements fixed withy M S angle iron frame of size 56X50X6mm including PCC work for grounding and duly painted with two coats of synthetic enmel paint over a coat of red oxide primer, standard copper conductor of suitable size including and cable gland to incoming and outgoing cable etc all as directed at site. INCOMING: i) MCCB 160 amps 04 pole 35KA (Double break contract Design with Adjustable type) 01 Nos ii) Ditial volt ineter 0 to 500 volt-01 Nos iii) Digital amp meter 0 to 200 amps-01 Nos iv) LED indicator set - 01Nos b)Out going: (i) MCCB 63Amps, 4 pole 25 KA , 415 Volts-02 Nos (ii) MCCB 4 Pole 40 Amps 10 KA, 415 volts- 02 Nos
S & F bollard light fitting LED decorative resistant to impact and corrsion glare free Cat part No.LPTO-40-CDL/M 40 watts Make: CG or equivalent.
Boing of holes under road pavement hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa pressure complete all as specified and directed.
Supply installations, testing and commissioning of transformer step down indoor colled, VECTOR group Dyn-11 double copper wound 11 KV/433 Volts, AC 3 phase 50 cycle 4 wire system of capacity 250KVA off curcuit tap changer on HT side to vary secondary voltage upto level + 7.5% volts in three step 2.5% each complete or as per manufacturere design withstandard acccessories of fitment all as per IS 1180 level one, conventional oil level indicator, drain valve for filtreration of oil, silicate, breather, explosion vent etc with first fill of transformer oil and complete with necessary civil work for foundation as per manufacturer recommendations complete all as specified and directed by Engr-in-Charge. Note: The transformer shall be provided with cable box on both HT and LT side.
Supply and fix rubber mating of size 2mtr X 1mtr X 119mm thick complete all as specified.
Supply installation testing and commissioning of 11KV 630 Amps 21 KVA outdoor typs both side extensible motorised 5 way SF6 gas insulated floor mounted with copper bus bar ring main unit should consist of 01 No incoming vaccum circuit breaker along with mechanical and electrical interlock and 04 Nos outgoing vaccum circuit breakeer. All live parts, bus bars, VCB will be enclosed in hermetically sealed 2/2.5mm thick stainless steel tank of SS441 grade with IP CLASS IP67 and tested as per latest IEC62271-200HT panel shall be with fixed type VCB for 11KV earth system 50Hz AC three phase including earth fault and over current protection relay with indicators as under:- i) Incoming and outgoing VCBs consisting of following:- a) Manual and motor operated 630A vaccum circuit breaker having spring mechanism. b) Three position disconnector/earthing switch down steam vaccum circuit- breaker. c) Three position single spring mechanism for disconnector/earthing switch. d) capacitive voltage indication fixed type. complete,
e) PUsh button for On/OFF the VCB. f) 30/C+1E/F self powered numerical proteciton relay with low and high set for over current and earth fault. g) Ring core protection current transformer for of suitable ratio 2.5VA with communication port. h) Mechanical ON/OFF/EARTH/SPring charge indication,. i) cable boxes suitable for 1X3CX120Sqmm XLPE cable with cable termination protectors. j) cable boxes should be Arc proof with hinged doors interlocked withrespective earthing switches. k) Mechanical as well as electrical interlocked should be provided to avoid phase shorting.
Supply install testing and commissioning of APFC panel of capacity 100 KVAR 3 Phase, 4 pole 415 volt indoor type made out of 2mm thick CRCA sheet, duly powder coated paint over a coat of red oxide primer, suitable for IP-54 protection class and having the name plate of the manufacture fixed to is and complete with contractor. APFC relay and power factor meter, making bank connection with suitable size of copper wire. CTR aluminium busbar, dust and vermin proof with angle iron 50x50x6mm frame (bottom portion of panel) on and including and cable entry boxes with calbe gland incl locking arrangement complete with the following.
INTERNAL WATER SUPPLY
S&F wall mixture with hot and cold water mixing mounted on wall 15 mm bore dia, cast copper alloy with capstan heads, CP screwed down, high pressure, with long screwed shanks and fly nuts fancy type screwed for iron pipe, fixed, complete all as specified
DEMOLITION
Taking down steel tubing and connection 20 mm bore, incl all fittings, complete all as specified.
Taking down steel tubing and connection 15 mm bore, incl all fittings, complete all as specified.
Taking down steel tubing and connection 25 to 40 mm bore, incl all fittings, complete all as specified.
Rabina Enterprises Pvt Ltd
Saru Enterprises Pvt Ltd
M/S S.R.M BUILDERS AND ENGINEERS PVT LTD
M/s Jatindra Construction Company
M/s Madan Lal Bansal and Co. Contractors Pvt. Ltd.
N K Gupta Builders Pvt. Ltd.
Bharat Constructions
Agarwal Jagdish Construction Company Pvt. Ltd.
Om Parkash Nargotra Constructions Pvt. Ltd.
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .