TRD
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited\ Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: 1. Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or 2.Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or 3.One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Definition of Similar Work(s) mentioned under Standard Technical Criteria: "Execution of any works of 25kV AC traction sub-stations or switching posts for Railways" Or "Execution of any HT Sub-station / Switch yard of voltage equal to or more than the voltage involved in the proposed tender work"
2 conditions · 1 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The tenderer firm should have Valid Electrical Contractors License granted by the Government. Tenderers should submit the copy of these certificates along with the tender document failing which the offer will liable to be rejected.
Augmentation/Improvement by Replacement of Overage PSI assets over Ratlam division
EL-TRD-58-2025-26-20~WR
EL-TRD-58-2025-26-20
Open
Works - General
18 Months
Ratlam, Madhya Pradesh
₹0
₹3.2 L
3 Feb 2026
9 Jan 2026
20 Jan 2026
63 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 3,32,60,566 | ||
| — | Breakup | for details. | — | ||
| Supply & Erection of Galvanised Steel Structure with SPS | — | — | — | 7,05,275 | |
| — | 35.00 | — | — | ||
| Concrete for foundation and plinth in all type of soil including hard soil and rock | — | — | — | 2,59,385 | |
| — | Breakup | for details. | — | ||
| Supply & Erection of galvanised Structure bonds & other bonds 40*6mm | — | — | — | 1,72,710 | |
| — | Breakup | for details. | — | ||
| Supply & Erection of galvanised Structure bonds & other bonds 50*6mm | — | — | — | 33,120 | |
| — | Breakup | for details. | — | ||
| Supply & Erection of Earth electrode assembly | — | — | — | 29,575 | |
| — | Breakup | for details. | — | ||
| Supply & erection of 132 kV Support Insulator. | — | — | — | 7,86,450 | |
| — | Breakup | for details. | — | ||
| Supply & erection of 132 KV, double pole SF-6 gas circuit breaker(1600A). | — | — | — | 14,90,194 | |
| — | Breakup | for details. | — | ||
| Supply, erection, testing & commissioning of 132 KV current transformer | — | — | — | 3,61,813 | |
| — | Breakup | for details. | — | ||
| Supply, erection, testing & commissioning of 132 KV lightening arrester | — | — | — | 4,23,834 | |
| — | Breakup | for details. | — | ||
| Supply, erection, testing & commissioning of 132 KV double pole isolator | — | — | — | 8,32,702 | |
| — | Breakup | for details. | — | ||
| Supply, erection, testing & commissioning of 132 KV potential transformer | — | — | — | 3,67,786 | |
| — | Breakup | for details. | — | ||
| Supply & erection of Control & Relay Panel for Shunt Capacitor Bank | — | — | — | 50,05,196 | |
| — | Breakup | for details. | — | ||
| Supply & erection of 25KV neutral current transformers. | — | — | — | 4,15,344 | |
| — | Breakup | for details. | — | ||
| Supply & erection of 25 KV single pole vacuum circuit breaker. | — | — | — | 50,74,860 | |
| — | Breakup | for details. | — | ||
| Supply & erection of 25 KV vacuum interrupter(1600 A). | — | — | — | 30,32,958 | |
| — | Breakup | for details. | — | ||
| Supply, erection, testing & commissioning of 25 KV potential transformer (Type-I) | — | — | — | 2,78,349 | |
| — | Breakup | for details. | — | ||
| Supply, erection, testing & commissioning of 25 KV potential transformer (Type-II) | — | — | — | 5,98,746 | |
| — | Breakup | for details. | — | ||
| Supply, erection, testing & commissioning of 25 KV current transformer | — | — | — | 2,72,002 | |
| — | Breakup | for details. | — | ||
| Supply, erection, testing & commissioning of 25 KV double pole isolator | — | — | — | 33,51,880 | |
| — | Breakup | for details. | — | ||
| Supply, erection, testing & commissioning of 25 KV lightening arrester | — | — | — | 3,16,092 | |
| — | Breakup | for details. | — | ||
| Supply, erection, testing & commissioning of 25 KV single pole isolator | — | — | — | 9,35,796 | |
| — | Breakup | for details. | — | ||
| Supply, erection, testing & commissioning of Battery Charger 110V, 200AH | — | — | — | 3,67,442 | |
| — | Breakup | for details. | — | ||
| Supply & erection of 25 kV Support/post Insulator. | — | — | — | 86,592 | |
| — | 3.00 | — | — | ||
| Erection, testing & commissioning of Shunt Capacitor Bank for 6600KVAR | — | — | — | 28,341 | |
| — | Breakup | for details. | — | ||
| Supply, erection, testing & commissioning of series reactor suitable for 6600KVAR Capacitor Bank | — | — | — | 65,46,664 | |
| — | 80.00 | — | — | ||
| Dismantling of PSI assets (from Sr No 7 to 21) | — | — | — | 4,97,440 | |
| — | 45.00 | — | — | ||
| Supply of Silica Gel Breather (250 gm) | — | — | — | 10,125 | |
| — | 45.00 | — | — | ||
| Supply of Silica Gel Breather ( clear view type ) of 0.500kg | — | — | — | 14,355 | |
| — | 10.00 | — | — | ||
| Supply of Silica Gel Breather (8Kg) | — | — | — | 55,220 | |
| — | 80.00 | — | — | ||
| Supply of Silica Gel | — | — | — | 10,320 | |
| — | 9000.00 | — | — | ||
| Supply of transformer oil | — | — | — | 9,00,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderdocPSI2024-25.pdf
ATTACHMENT
GCCApril2022.pdf
ATTACHMENT
GCCACS1to10.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .