Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.4 LAccepted-AOC 20 JAIN BAZAR JAMMU 180003 J K | JAMMU | JAMMU | J K | 180003 | L1 | Accepted-AOC L1 | |
| 2 | L2₹36.9 L+₹1.9 L (5.42%)Rejected-Finance C O KHASRA NO 483 KALSHUM AKHTAR PANCHAYAT KAHYTAR MALAD MORH REHMBAL UDHAMPUR 182121 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182121 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹37.2 L+₹2.2 L (6.23%)Rejected-Finance HOUSE NO 41 WARD NO 09 ARYA SAMAJ GALI UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹37.2 L+₹2.2 L (6.29%)Rejected-Finance WARD NO 11 HOUSE NO 305 JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹39.9 L+₹4.9 L (13.9%)Rejected-Finance SHOP NO 82 6 TRANSPORT NAGAR NARWAL JAMMU 180004 | JAMMU | JAMMU | J K | 180004 | L5 | Rejected-Finance OTHER THAN L1 |
| Sl No | Description | Qty | Unit | VARDHMAN INTERNATIONAL L8 | Balbir Enterprises L5 | SINGH CONST CO L6 | A K JAIN AND SONS L1 | PARDEEP SHARMA L4 | M/S DHARAM & SONS ENTERPRISES L7 | A K ENTERPRISES ENGINEER CONTRACTOR AND GEN ORDER SUPPLIERS L2 | M/S N.K. POWER SYSTEMS AND PROJECTS L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Material and labour for carrying out ‘B’ check for various capacity DG set by replacing the following accessories of DG set, complete all as specified and directed by Engineer-in-Charge. (a) Oil filter. (b) Air filter. (c) Fuel filter. (d) By pass filter. (e) Engine oil . (f) coolent. Note :- Service Certificate of the 'B' Check shall be submitted by the contractor. (ii) Engine oil & coolent shall be measured and paid separately. (iii) Labour & transportation shall be arranged by contractor and quoted rate deemed to be inclusive in the unit rate. Make of DG set shall be repaired : KIRLOSKER/ CUMMINS /GREAVES. | |||||||||||
| 1.01 | Description all as per Ser item No.1.00 here-in-before but for 320 to 500 KVA DG set, complete all as specified and directed by Engineer-in-Charge. | 4 | Each Job | 10,000 ₹40,000 | 5,000 ₹20,000 Lowest | 10,000 ₹40,000 | 20,000 ₹80,000 | 10,000 ₹40,000 | 13,000 ₹52,000 | 13,000 ₹52,000 | 5,800 ₹23,200 |
| 1.02 | Description all as per Ser item No.1.00 here-in-before but for 160 to 250 KVA DG set, complete all as specified and directed by Engineer-in-Charge. | 12 | Each Job | 6,000 ₹72,000 | 3,500 ₹42,000 Lowest | 8,500 ₹1,02,000 | 18,000 ₹2,16,000 | 8,000 ₹96,000 | 8,000 ₹96,000 | 10,000 ₹1,20,000 | 5,000 ₹60,000 |
| 1.03 | Description all as per Ser item No.1.00 here-in-before but for 100 to 125 KVA DG set, complete all as specified and directed by Engineer-in-Charge.. | 15 | Each Job | 4,500 ₹67,500 | 3,500 ₹52,500 Lowest | 7,000 ₹1,05,000 | 10,000 ₹1,50,000 | 7,000 ₹1,05,000 | 4,000 ₹60,000 | 8,000 ₹1,20,000 | 4,000 ₹60,000 |
| 1.04 | Description all as per Ser item No.1.00 here-in-before but for 30 to 75 KVA DG set, complete all as specified and directed by Engineer-in-Charge. | 8 | Each Job | 3,500 ₹28,000 | 3,500 ₹28,000 | 3,500 ₹28,000 | 8,000 ₹64,000 | 6,500 ₹52,000 | 3,500 ₹28,000 | 7,000 ₹56,000 | 3,400 ₹27,200 Lowest |
| 1.05 | Description all as per Ser item No.1.00 here-in-before but for 10 to 30 KVA DG set, complete all as specified and directed by Engineer-in-Charge. | 8 | Each Job | 2,000 ₹16,000 Lowest | 3,500 ₹28,000 | 2,400 ₹19,200 | 7,500 ₹60,000 | 5,500 ₹44,000 | 2,900 ₹23,200 | 6,000 ₹48,000 | 3,000 ₹24,000 |
| 2.00 | Taking out the existing battery of DG set and repair/replacement of unserviceable/faulty lead acid Battery of capacity 150 AH, 12V including connecting to DG set,complete all as specified and directed by Engineer-in-Charge. | 5 | Each | 13,000 ₹65,000 | 18,000 ₹90,000 | 13,500 ₹67,500 | 15,000 ₹75,000 | 11,000 ₹55,000 Lowest | 13,500 ₹67,500 | 12,500 ₹62,500 | 12,000 ₹60,000 |
| 3.00 | Description all as per item No. 2.00 here-in-before but of 180 AH, 12V including connecting to DG set, complete all as specified and directed by Engineer-in-Charge. | 10 | Each | 14,500 ₹1,45,000 Lowest | 20,000 ₹2,00,000 | 15,000 ₹1,50,000 | 18,500 ₹1,85,000 | 16,900 ₹1,69,000 | 21,000 ₹2,10,000 | 15,000 ₹1,50,000 | 17,000 ₹1,70,000 |
| 4.00 | Renewal/ repairs/supply of unserviceable automatic voltage regulator (AVR) 10 to 160 KVA DG set including all spares, testing, complete all as specified and directed by Engineer-in-Charge.
Make:- As per OEM approved make. | 4 | Each Job | 2,500 ₹10,000 Lowest | 2,500 ₹10,000 Lowest | 10,000 ₹40,000 | 3,000 ₹12,000 | 7,000 ₹28,000 | 3,500 ₹14,000 | 4,000 ₹16,000 | 8,000 ₹32,000 |
| 5.00 | Renewal/ repairs/supply of unserviceable automatic voltage regulator (AVR) 200 KVA to 500 KVA DG set including all spares, testing, complete all as specified and directed by Engineer-in-Charge.
Make:- As per OEM approved make. | 4 | Each Job | 5,000 ₹20,000 | 3,500 ₹14,000 Lowest | 10,000 ₹40,000 | 5,000 ₹20,000 | 9,000 ₹36,000 | 4,500 ₹18,000 | 7,000 ₹28,000 | 13,000 ₹52,000 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
12 May 2026, 6:00 pmClosed
GE (Utilities) Udhampur
GE (Utilities) Udhampur PO-Garhi pin-182121
Repair/Maint of DG sets in AOR of CPH and other locations under GE Utilities Udhampur
2026_MES_761305_1
GE/U-13/2026-27
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (Utilities) Udhampur
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (Utilities) Udhampur
₹98,000
30 May 2026
21 Apr 2026
14 May 2026
21 Apr 2026
12 May 2026
5 May 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: GE Utilities Udhampur
Name of Work: Repair/Maint to of DG Sets in AOR of CPH and other locations under GE Utilities Udhampur
Contract No: GE/U-13/2026-27
Ser. No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category
Material and labour for carrying out ‘B’ check for various capacity DG set by replacing the following accessories of DG set, complete all as specified and directed by Engineer-in-Charge. (a) Oil filter. (b) Air filter. (c) Fuel filter. (d) By pass filter. (e) Engine oil . (f) coolent. Note :- Service Certificate of the 'B' Check shall be submitted by the contractor. (ii) Engine oil & coolent shall be measured and paid separately. (iii) Labour & transportation shall be arranged by contractor and quoted rate deemed to be inclusive in the unit rate. Make of DG set shall be repaired : KIRLOSKER/ CUMMINS /GREAVES. BI01010001010000000000000515BI0100001134
Description all as per Ser item No.1.00 here-in-before but for 320 to 500 KVA DG set, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001135 Each Job 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No.1.00 here-in-before but for 160 to 250 KVA DG set, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001136 Each Job 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No.1.00 here-in-before but for 100 to 125 KVA DG set, complete all as specified and directed by Engineer-in-Charge.. BI01010001010000000000000515BI0100001137 Each Job 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No.1.00 here-in-before but for 30 to 75 KVA DG set, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001138 Each Job 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No.1.00 here-in-before but for 10 to 30 KVA DG set, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001139 Each Job 0.0000 Excess(+) Full Conversion INR
Taking out the existing battery of DG set and repair/replacement of unserviceable/faulty lead acid Battery of capacity 150 AH, 12V including connecting to DG set,complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001140 Each 0.0000 Excess(+) Full Conversion INR
Description all as per item No. 2.00 here-in-before but of 180 AH, 12V including connecting to DG set, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001141 Each 0.0000 Excess(+) Full Conversion INR
Renewal/ repairs/supply of unserviceable automatic voltage regulator (AVR) 10 to 160 KVA DG set including all spares, testing, complete all as specified and directed by Engineer-in-Charge. Make:- As per OEM approved make. BI01010001010000000000000515BI0100001142 Each Job 0.0000 Excess(+) Full Conversion INR
Renewal/ repairs/supply of unserviceable automatic voltage regulator (AVR) 200 KVA to 500 KVA DG set including all spares, testing, complete all as specified and directed by Engineer-in-Charge. Make:- As per OEM approved make. BI01010001010000000000000515BI0100001143 Each Job 0.0000 Excess(+) Full Conversion INR
Dismantling of exhaust pipe of the DG set 63 KVA to 500 KVA capacity by unscrewnuts and bolts and taking down the pipe with muffler, cleaning the silencer,welding works if required ,painting and fixing the same in its original position, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001144 Each Job 0.0000 Excess(+) Full Conversion INR
Disconnecting all the incoming and outgoing rubber hoses and draining out the water from the choked radiator assembly of the existing make and model and various capacities DG sets and taking down the radiator assembly by unscrewing all mechanical/electrical connections from the existing mounting, transporting the same to civil workshop for carrying out servicing, opening the top and bottom covers of radiator assembly, cleaning thoroughly the chocked pipe of the radiator by using chemical detergent, lime caustic soda, cotton etc., cleaning of all the deposited sediments in the pipes/tubes including arresting of leakage by means of soldering, brazing and transporting back to site and refixing the same in its original position with suitable size nuts, bolts and washers and Anti vibrating mounting(AVM) pads as required as per OEM recomendation etc., for the DG set of capacity up to 500 KVA, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001145 Each Job 0.0000 Excess(+) Full Conversion INR
Renewal /supply of battery cable leads of copper conductor and with brass lugs terminal, for the 12V, 150/180 /200 AH batteries to self stater as that of existing size and length, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001146 Each set 0.0000 Excess(+) Full Conversion INR
Taking down the U/S belt from the DG set Supply ,test and commissioning of belts suitable for fan ,alternator, dynmo, radiator of the DG Set of capacity 10 KVA to 500 KVA, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001147 Each 0.0000 Excess(+) Full Conversion INR
Engine oil 15W/40 for toping up upto the required level and service, complete all as specified and directed by Engr-in-Charge. Make :- CASTROL/ INDIAN OIL/ SERVO BI01010001010000000000000515BI0100001148 Ltr 0.0000 Excess(+) Full Conversion INR
Replacement /supplyof Line Voltage Monitors (LVMS) of existing make of DG set of 100 KVA to 500 KVA capacity listed parameters including testing, complete all as specified and directed by Engineer-in-Charge. Make :- OEM recommended BI01010001010000000000000515BI0100001149 Each 0.0000 Excess(+) Full Conversion INR
Replacement/supply of Line Voltage Monitors (LVMS) of existing make of DG set capacity up to100 KVA capacity listed parameters including testing, complete all as specified and directed by Engineer-in-Charge. Make :- OEM reccommended BI01010001010000000000000515BI0100001150 Each 0.0000 Excess(+) Full Conversion INR
Drain out the fuel from the fuel tank of DG set of any size/capacity and keeping it in separate container safely, disconnecting all the fuel lines and other mechanical connections and taking out the fuel tank for cleaning, internally and externally by removing all the accumulated dirt/ sediment, leak testing the tank and welding/ brazing including one coat of synthetic enamel paint, refixing the tank in its original position, replacing the drain plug and PVC pipe, calibrating the fuel tank, refilling the drained out fuel back into the tank and marking of liters in gauge and provision of locking arrangements, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001151 Each Job 0.0000 Excess(+) Full Conversion INR
Drain out the fuel from the fuel tank of capacity 24 KL Diesel tank and keeping it in separate container safely, disconnecting all the fuel lines and other mechanical connections and taking out the fuel tank for cleaning, internally and externally by removing all the accumulated dirt/ sediment, leak testing the tank.incl two coat of synthetic enamel paint, refilling the drained out fuel back into the tank and marking of liters in gauge and provision of locking arrangements, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001152 Each Job 0.0000 Excess(+) Full Conversion INR
Removing the defective charging dynamo/alternator of capacity 12/24 Volt DC any make, model, of capacity 10 to 100 KVA and opening it by removing all nuts and bolts, cleaning with necessary cleaning agent and overhauling, lubricating of the rewinding the damaged winding of field coils with super enameled copper wire suitable for same existing size/guage & reconnecting the same, refixing back in original position including making all necessary electrical/mechanical connections, testing and commissioning, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001153 Each Job 0.0000 Excess(+) Full Conversion INR
Removing the defective charging dynamo/alternator of capacity 12/24 Volt DC any make, model, of capacity 100 to 500 KVA and opening it by removing all nuts and bolts, cleaning with necessary cleaning agent and overhauling, lubricating of the rewinding the damaged winding of field coils with super enameled copper wire suitable for same existing size/guage & reconnecting the same, refixing back in original position including making all necessary electrical/mechanical connections, testing and commissioning, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001154 Each Job 0.0000 Excess(+) Full Conversion INR
Inhibitor corrosion (coolant additive concentrate) required for top up, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001155 Ltr 0.0000 Excess(+) Full Conversion INR
Supply and topping up of acid mixture suitable for lead acid batteries of 12 volts, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001156 Ltr 0.0000 Excess(+) Full Conversion INR
Supply and topping up of distilled water suitable for lead acid batteries of 12 volts, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001157 Ltr 0.0000 Excess(+) Full Conversion INR
Supply and fix Battery brass terminal and jelly, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001158 Each 0.0000 Excess(+) Full Conversion INR
Calibration of the U/S Fuel injection pump assy ,Test & commisioning of Fuel injection pump assy after calibration inclusive of injector system for following DG set, complete all as specified and directed by Engineer-in-Charge:- Note :- Calibration shall be performed before erection of FIP. (a) 10 KVA to 500 KVA BI01010001010000000000000515BI0100001159 Each Job 0.0000 Excess(+) Full Conversion INR
Overhauling of injector nozzles of capacity 160 KVA to 320 KVA test & commisioning of injector nozzles inclusive of injector system, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001160 Each Job 0.0000 Excess(+) Full Conversion INR
Overhauling of injector nozzles of capacity 40 KVA to 125 KVA test & commisioning of injector nozzles inclusive of injector system, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001161 Each Job 0.0000 Excess(+) Full Conversion INR
Overhauling of injector nozzles of capacity 10 KVA to 40 KVA test & commisioning of injector nozzles inclusive of injector system, complete all as specified and directed by Engr-in-Charge. BI01010001010000000000000515BI0100001162 Each Job 0.0000 Excess(+) Full Conversion INR
Repair to Self starter Motor, 12/24 volts, suitable for existing DG set above 10 KVA to 160 KVA capacity including making all necessary electrical/mechanical connection as per recomendation of OEM of DG Set & dismantling/taking out old unserviceable self starter Motor from existing position, complete all as specified and directed by Engineer-in-Charge. Make :- Approved by OEM of DG set. BI01010001010000000000000515BI0100001163 Job 0.0000 Excess(+) Full Conversion INR
Repair to Self starter Motor, 12/24 volts, suitable for existing DG set above 200 KVA to 500 KVA capacity including making all necessary electrical/mechanical connection as per recomendation of OEM of DG Set & dismantling/taking out old unserviceable self starter Motor from existing position, complete all as specified and directed by Engineer-in-Charge. Make :- Approved by OEM of DG set. BI01010001010000000000000515BI0100001164 Job 0.0000 Excess(+) Full Conversion INR
S & F Diesel benjo Hose pipes of 1.0 Meter length with both edges brass clamps of existing model suitable to DG Set of capacity up to 160 KVA including taking down old unserviceable one, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001165 Each Job 0.0000 Excess(+) Full Conversion INR
S & F Diesel benjo Hose pipes of 1.0 Meter length with both edges brass clamps of existing model suitable to DG Set of capacity above 200 KVA up to 500 KVA including taking down old unserviceable one, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001166 Each Job 0.0000 Excess(+) Full Conversion INR
Repairs to Alternator of following DG Sets, transporting the same to the OEM authorised service center/work shop and carrying out the repairs such as taking out the burnt out winding and rewinding the alternator with copper wire of same guage turns and weight, checking of commentator, brushes complete and refixing the same in its existing position after transporting back to the site and connecting up electric connections with suitable lugs complete and testing, complete all as specified and directed by Engineer-in-Charge:- Note: Copper winding material will be measured and paid seperately under relevant Item BI01010001010000000000000515BI0100001167
DG set Upto 160 KVA capacity. BI01010001010000000000000515BI0100001168 Each Job 0.0000 Excess(+) Full Conversion INR
DG Set of capacity 200KVA to 500 KVA. BI01010001010000000000000515BI0100001169 Each Job 0.0000 Excess(+) Full Conversion INR
Supply only High conductivity copper conductor winding material including necessary insulation material required, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001170 Kg 0.0000 Excess(+) Full Conversion INR
Overhauling of Turbo Charger Assembly duly disconnecting the mechanical and electrical connections from for the following DG sets, opening and thoroughly checking to carry out repairs complete to the Turbo Charger Kit and spares as required at site including any mechanical and reassembling and refixing the same after repair to its original position and reconnecting the same including testing, complete all as specified and directed by Engineer-in-Charge:- BI01010001010000000000000515BI0100001171
DG Sets of capacity 10 to 160 KVA. BI01010001010000000000000515BI0100001172 Each Job 0.0000 Excess(+) Full Conversion INR
DG Sets of capacity 200 KVA to 500 KVA. BI01010001010000000000000515BI0100001173 Each Job 0.0000 Excess(+) Full Conversion INR
Dismantling & disconnecting all connection of upper and lower engine, cylinder heads,lines,thrust valve,valve seat inlet and exhaust,main bearing set,inlet valve and exhaust valve,head gasket,CR bearing,hose set,ring set,valve seal,liner O ring,oil seal set,O rings kit,Crank shaft ,Connecting roads,Push roads,Valve Guides, Valves seats. and all connecting items like ring ,washer,gasket etc from diesel engine and sent to OEM authorised Service center for calibration and repairs by replacing the all above said spares such as cylinder heads,lines,thrust valve,valve seat inlet and exhaust,main bearing set,inlet valve and exhaust valve,head gasket,CR bearing,hose set,ring set,valve seal,liner O ring,oil seal set,O rings kit,Crank shaft ,Connecting roads,Push roads,Valve Guides, Valves seats ,piston assy and all connecting items like ring ,washer,gasket etc and re-assembling to its original position with necessary fittings and O rings for the following capacities including testing, complete all as specified and directed by Engineer-in-Charge . Note : Any minor or major spares other than above is included in the quoted rates. BI01010001010000000000000515BI0100001174
DG Sets of capacity 10 to 160 KVA. BI01010001010000000000000515BI0100001175 Each Job 0.0000 Excess(+) Full Conversion INR
DG Sets of capacity 200 to 320 KVA. BI01010001010000000000000515BI0100001176 Each Job 0.0000 Excess(+) Full Conversion INR
Taking down unserviceable camshaft assembly of 500 kVA diesel generator set make -greaves , including dismantling of engine components as required, removal of defective camshaft, cleaning of mating surfaces, and supplying & fixing in replacement new camshaft assembly for 500 KVA DG set of make- greaves, including bearings, bushes, alignment, setting of valve timing, reassembly, oiling, testing and commissioning complete all as specified and directed by Engineer-in-Charge . BI01010001010000000000000515BI0100001177 Each 0.0000 Excess(+) Full Conversion INR
Taking down unserviceable piston assembly of 500 kVA diesel generator set make -greaves, including opening of cylinder head/crankcase as required, removal of worn-out piston assembly, cleaning of cylinder liner and mating parts, and supplying & fixing new piston assembly in replacemrnt for 500 KVA DG set of make- greaves complete with piston rings, gudgeon pin, circlips, including checking of clearances, lubrication, reassembly, tightening, testing and commissioning complete all as specified and directed by Engineer-in-Charge . BI01010001010000000000000515BI0100001178 Each 0.0000 Excess(+) Full Conversion INR
Taking down unserviceable water pump assembly of 500 kVA diesel generator set make -greaves, including draining of coolant, dismantling of connected piping, belts and mounting arrangement, removal of defective pump, cleaning of mating surfaces, and supplying & fixing new water pump assembly in replacemrnt for 500 KVA DG set of make- greaves complete with impeller, shaft, bearings and seals of make Greaves, including refitting, alignment, belt tensioning, refilling coolant, testing and commissioning complete all as specified and directed by Engineer-in-Charge . BI01010001010000000000000515BI0100001179 Each 0.0000 Excess(+) Full Conversion INR
Taking down unserviceable Fuel injection pump assy (FIP) of 500 kVA diesel generator set make -greaves, and supplying & fixing new Fuel injection pump assy (FIP) pump assembly in replacemrnt for 500 KVA DG set of make- greaves complete with Test & commisioning of Fuel injection pump assy inclusive of injector system complete all as specified and directed by Engineer-in-Charge . BI01010001010000000000000515BI0100001180 Each 0.0000 Excess(+) Full Conversion INR
Supply and fix in replacement 'cylinder head bolt' for DG set of 500 KVA capacity including testing, complete all as specified and directed by Engineer-in-Charge . BI01010001010000000000000515BI0100001181 Each 0.0000 Excess(+) Full Conversion INR
Supply and fix in replacement 'Inlet Valve' for DG set of 500 KVA capacity including testing, complete all as specified and directed by Engineer-in-Charge . BI01010001010000000000000515BI0100001182 Each 0.0000 Excess(+) Full Conversion INR
Supply and fix in replacement 'Exhaust Valve' for DG set of 500 KVA capacity including testing, complete all as specified and directed by Engineer-in-Charge . BI01010001010000000000000515BI0100001183 Each 0.0000 Excess(+) Full Conversion INR
Supply and fix in replacement 'set of Gaskets' for DG set of 500 KVA capacity including testing, complete all as specified and directed by Engineer-in-Charge . BI01010001010000000000000515BI0100001184 Each 0.0000 Excess(+) Full Conversion INR
Supply and fix in replacement 'Idler gear Bush Assembly' for DG set of 500 KVA capacity including testing, complete all as specified and directed by Engineer-in-Charge . BI01010001010000000000000515BI0100001185 Each 0.0000 Excess(+) Full Conversion INR
Supply and fix in replacement 'Main Bearing set' for DG set of 500 KVA capacity including testing, complete all as specified and directed by Engr-in-Charge. BI01010001010000000000000515BI0100001186 Each 0.0000 Excess(+) Full Conversion INR
Supply and fix in replacement 'connecting rod Bearring set' for DG set of 500 KVA capacity including testing, complete all as specified and directed by Engineer-in-Charge . BI01010001010000000000000515BI0100001187 Each 0.0000 Excess(+) Full Conversion INR
Supply and fix in replacement 'D - Liner of Dia -115 mm' for DG set of 500 KVA capacity including testing, complete all as specified and directed by Engr-in-Charge. BI01010001010000000000000515BI0100001188 Each 0.0000 Excess(+) Full Conversion INR
Supply and fix in replacement 'Valve Guide -semi finish' for DG set of 500 KVA capacity including testing, complete all as specified and directed by Engineer-in-Charge . BI01010001010000000000000515BI0100001189 Each 0.0000 Excess(+) Full Conversion INR
Supply and fix in replacement 'connecting rod bolt M12X 1.25X67' for DG set of 500 KVA capacity including testing, complete all as specified and directed by Engineer-in-Charge . BI01010001010000000000000515BI0100001190 Each 0.0000 Excess(+) Full Conversion INR
Supply and fix in replacement 'Magnetic Pick sensor' for DG set of 500 KVA capacity including testing, complete all as specified and directed by Engineer-in-Charge . BI01010001010000000000000515BI0100001191 Each 0.0000 Excess(+) Full Conversion INR
Supply and fix in replacement 'Gasket cylinder head' for DG set of 500 KVA capacity including testing, complete all as specified and directed by Engineer-in-Charge . BI01010001010000000000000515BI0100001192 Each 0.0000 Excess(+) Full Conversion INR
Supply and fix in replacement 'O ring liner ' for DG set of 500 KVA capacity including testing, complete all as specified and directed by Engineer-in-Charge . BI01010001010000000000000515BI0100001193 Each 0.0000 Excess(+) Full Conversion INR
Supply and fix in replacement 'Bush small end' for DG set of 500 KVA capacity including testing, complete all as specified and directed by Engineer-in-Charge . BI01010001010000000000000515BI0100001194 Each 0.0000 Excess(+) Full Conversion INR
Supply and fix in replacement 'Tappet ' for DG set of 500 KVA capacity including testing, complete all as specified and directed by Engineer-in-Charge . BI01010001010000000000000515BI0100001195 Each 0.0000 Excess(+) Full Conversion INR
Supply and fix in replacement 'fuel injectors Including injection pipes' for DG set of 500 KVA capacity including testing, complete all as specified and directed by Engineer-in-Charge . BI01010001010000000000000515BI0100001196 Each 0.0000 Excess(+) Full Conversion INR
Replacement of Hoses & fuel/oil pipes for DG set of 500 KVA capacity comprising Hose Air filter, Hose water pipe radiator, hose water pump, hose to thermostat to radiator A & B bank, hose for spout, hose air filter to turbo, air filter to junction hose, water hose for RCF, pipe FIP oil supply, turbo oil supply pipe, fuel pipe feed pump to filter, fuel pipe FIP to filter A bank motor, fuel pipe FIP to filter B bank motor, flex pipe crankcase to NRV, Fuel hose feed pump 1 to fuel filter 1, fuel filter 1 to shut off valve 1, fuel hose feed pump 2 to fuel filter 2, flex pipe oil c case to FIP including testing, complete all as specified and directed by Engineer-in-Charge . BI01010001010000000000000515BI0100001197 Each Job 0.0000 Excess(+) Full Conversion INR
Supply and fix New Turbo Charger Assembly In replacement duly disconnecting the mechanical and electrical connections from for the following DG sets, opening and thoroughly checking to carry out repairs complete to the Turbo Charger Kit and spares as required at site including any mechanical and reassembling and refixing the new turbo charger assembly to its original position and reconnecting the same including testing, complete all as specified and directed by Engineer-in-Charge:- BI01010001010000000000000515BI0100001198
DG Sets of capacity 10 to 160 KVA. BI01010001010000000000000515BI0100001199 Each Job 0.0000 Excess(+) Full Conversion INR
DG Sets of capacity 200 KVA to 320 KVA. BI01010001010000000000000515BI0100001200 Each Job 0.0000 Excess(+) Full Conversion INR
DG Sets of capacity 500 KVA. BI01010001010000000000000515BI0100001201 Each Job 0.0000 Excess(+) Full Conversion INR
Earthing complete with GI earth plate electrode 60cm x 60cm x 3mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Aluminium earth strip 32 x 6mm dia, by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth elelctrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion, complete all as specified and directed by Engr-in-Charge. Note:- Item of earthing includes cost of 7.5m long aluminium strip of 32 x 6mm size and protection pipe of 40mm bore GI medium grade. BI01010001010000000000000515BI0100001202 Each Job 0.0000 Excess(+) Full Conversion INR
Supply and fix tappet cover for DG set of 10 KVA to 100 KVA capacity with all listed parameters as per OEM recommendation including testing, complete all as specified and directed by Engineer-in-Charge . BI01010001010000000000000515BI0100001203 Each 0.0000 Excess(+) Full Conversion INR
Supply and fix tappet cover for DG set of 125 KVA to 500 KVA capacity with all listed parameters as per OEM recommendation including testing, complete all as specified and directed by Engineer-in-Charge . BI01010001010000000000000515BI0100001204 Each 0.0000 Excess(+) Full Conversion INR
Replacement of controller display suitable to DG set controlls/commands of 10 KVA to 160 KVA capacity with all listed parameters as per OEM recommendation including testing, complete all as specified and directed by Engineer-in-Charge . BI01010001010000000000000515BI0100001205 Each 0.0000 Excess(+) Full Conversion INR
Replacement of controller display suitable to DG set controlls/commands of 200 KVA to 500 KVA capacity with all listed parameters as per OEM recommendation including testing,complete all as specified and directed by Engineer-in-Charge . BI01010001010000000000000515BI0100001206 Each 0.0000 Excess(+) Full Conversion INR
Replacement of microprocessor based control unit suitable to DG set controlls/commands of up to 160 KVA capacity with all listed parameters as per recomendation including testing, complete all as specified and directed by Engineer-in-Charge . BI01010001010000000000000515BI0100001207 Each 0.0000 Excess(+) Full Conversion INR
Replacement of microprocessor based control unit suitable to DG set controlls/commands of 200 to 500 KVA capacity with all listed parameters as per OEM recommendation including testing, complete all as specified and directed by Engineer-in-Charge . BI01010001010000000000000515BI0100001208 Each 0.0000 Excess(+) Full Conversion INR
Replacement of microprocessor based Display unit(HMI) suitable to DG set controlls/commands of 10 KVA to 500 KVA capacity with all listed parameters as per OEM recommendation including testing, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001209 Each 0.0000 Excess(+) Full Conversion INR
Replacement of Actuator suitable to DG set controlls/commands of 10 KVA to 160 KVA capacity with all listed parameters as per OEM recommendation including testing,complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001210 Each 0.0000 Excess(+) Full Conversion INR
Replacement of Actuator suitable to DG set controlls/commands of 200 KVA to 500 KVA capacity with all listed parameters as per OEM recommendation including testing, complete all as specified and directed by Engineer-in-Charge . BI01010001010000000000000515BI0100001211 Each 0.0000 Excess(+) Full Conversion INR
Supply and mounting AVM(anti vibration) pads for Engine,radiator and alternator of DG set of any capacity including labour charges for proper mounting and all necessary misc accessroies, complete all as specified and directed by Engineer-in-Charge . BI01010001010000000000000515BI0100001212 Each set 0.0000 Excess(+) Full Conversion INR
Supply and fix Asbestos rope suitable for existing DG set including, complete all as specified and directed by Engineer-in-Charge . BI01010001010000000000000515BI0100001213 Each job 0.0000 Excess(+) Full Conversion INR
Supply, installation, and commissioning of Automatic SMPS battery charger of approved make 230 V AC input and output 12V/24 V, 10 Amps charging rating suitable for charging DG set lead-acid batteries, with over-voltage, over-current, and short-circuit protection, including mounting, cabling, testing complete all as specified and directed by Engineer-in-Charge . BI01010001010000000000000515BI0100001214 Per job 0.0000 Excess(+) Full Conversion INR
Supply and fix fuel tank lock and key suitable for existing DG set including removing old un seviceable one, complete all as specified and directed by Engr-in-Charge. BI01010001010000000000000515BI0100001215 Per job 0.0000 Excess(+) Full Conversion INR
Supply and fix Door lock and key with door rod assy in side the door suitable for existing DG set including removing old un seviceable one, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001216 Per job 0.0000 Excess(+) Full Conversion INR
Supply and fix Door hinges suitable for existing DG set including removing old un seviceable one, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001217 Per job 0.0000 Excess(+) Full Conversion INR
Taking down the U/S control cable from DG set & AMF panel Supply ,install ,Test & commisioning of control cable from DG set alternator unit to AMF unit of following size DG set, complete all as specified and directed by Engineer-in-Charge:- (a) 120 sq mm BI01010001010000000000000515BI0100001218 RM 0.0000 Excess(+) Full Conversion INR
50 sq mm BI01010001010000000000000515BI0100001219 RM 0.0000 Excess(+) Full Conversion INR
Replacement of on load change over switch, 125 Amps capacity, suitable for 3 phase, 4 pole, 415 Volts,front handle operated suitable in open execution type for fixing in existing panels including necessary lugs,glands.,nuts,bolts inclduing taking down old unserviceable one, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001220 Each 0.0000 Excess(+) Full Conversion INR
Replacement of on load change over switch, 250 Amps capacity, suitable for 3 phase, 4 pole, 415 Volts,front handle operated suitable in open execution type for fixing in existing panels including necessary lugs,glands.,nuts,bolts inclduing taking down old unserviceable one, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001221 Each 0.0000 Excess(+) Full Conversion INR
Replacement of on load change over switch, 400 Amps capacity, suitable for 3 phase, 4 pole, 415 Volts,front handle operated suitable in open execution type for fixing in existing panels including necessary lugs,glands.,nuts,bolts inclduing taking down old unserviceable one,complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001222 Each 0.0000 Excess(+) Full Conversion INR
Supply and fix Contactor Assembly & PLCs wtih under+ over voltage relay for existing DG set AMF panel of capacity 160 to 500 KVA including removing old un seviceable one, complete all as specified and directed by Engr-in-Charge. BI01010001010000000000000515BI0100001223 Job 0.0000 Excess(+) Full Conversion INR
Servicing to AMF panel of capacity 10 KVA to 160 KVA from the Circuit system by checking the following parameters for proper functioning, complete all as specified and directed by Engineer-in-Charge. a) Checking / fault diagnosis of Isolator ,Battery charger,Auto/Manual selector switch & Current Transformer. b) Checking the Electronic circuit boards with phase indication lamp 220 V. c) Checking the functionality & caliberation of Power Relays (Cranking Relays). d) Checking the Mechanism of isolator module and vcb module Note :- Rates of all spares and Parts including repair and replace are included in quoted rate. BI01010001010000000000000515BI0100001224 Job 0.0000 Excess(+) Full Conversion INR
Servicing to AMF panel of capacity 200 KVA to 500 KVA from the Circuit system by checking the following parameters for proper functioning, complete all as specified and directed by Engineer-in-Charge. a) Checking / fault diagnosis of Isolator ,Battery charger,Auto/Manual selector switch & Current Transformer. b) Checking the Electronic circuit boards with phase indication lamp 220 V. c) Checking the functionality & caliberation of Power Relays (Cranking Relays). d) Checking the Mechanism of isolator module and vcb module Note :- Rates of all spares and Parts including repair and replace are included in quoted rate. BI01010001010000000000000515BI0100001225 Job 0.0000 Excess(+) Full Conversion INR
Supply and fix Copper lugs 120 sqmm to 150 sqmm suitable for 1100 Volt copper cable suitable for existing DG set including removing old unserviceable one, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001226 Each 0.0000 Excess(+) Full Conversion INR
Taking down the U/S primary diesel feeder pump assy from DG set Supply ,install ,Test & commisioning of primary diesel feeder pump assy inclusive of all spare and parts system for following DG set, complete all as specified and directed by Engineer-in-Charge:- Note :- Calibration shall be performed before erection of pump. (a) 10 KVA to 160 KVA BI01010001010000000000000515BI0100001227 Each 0.0000 Excess(+) Full Conversion INR
Taking down the U/S primary diesel feeder pump assy from DG set Supply ,install ,Test & commisioning of primary diesel feeder pump assy inclusive of all spare and parts system for following DG set, complete all as specified and directed by Engineer-in-Charge. Note :- Calibration shall be performed before erection of pump. (a) 200 KVA to 500 KVA BI01010001010000000000000515BI0100001228 Each 0.0000 Excess(+) Full Conversion INR
Complaint/Inspection & visit the power house for checking the fault occure in DG set of any capacity ,Rectify the fault at own arrangement and report to JE /Engr in charge after rectifying the fault and proper testing and commissioning of DG. All spare abd parts will be paid and measured separately at site, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001229 Each Job 0.0000 Excess(+) Full Conversion INR
Supply and fix Hour meter operating on 240 V suitable for existing DG set including removing old un seviceable one, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001230 Per job 0.0000 Excess(+) Full Conversion INR
Supply and fix garage mats for floor absorb liquid oil drips pan with waterproof Rubber backing layer for protection of floors. Size of mat 1 mtr x 4 mtr for DG set at substation, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001231 Each 0.0000 Excess(+) Full Conversion INR
M & L for Comprehensive repair of RECD sytem installed on DG sets upto 500 KVA comprising inspection, cleaning, replacement of worn-out filters with approved make, reassembly, and submission of service report complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001232 Each Job 0.0000 Excess(+) Full Conversion INR
M & L for Comprehensive replacement of instrumentation and control system of RECD fitted to DG Set upto 500 kVA comprising supply and fixing in replacement of pressure sensor, temperature sensor, and control panel of approved make, complete with cabling, calibration, testing, and submission of service report complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001233 Each Job 0.0000 Excess(+) Full Conversion INR
M & L for conducting emission (pollution) testing of RECD (Retrofit Emission Control Device) installed on DG sets of capacity up to 500 kVA, including deployment of calibrated testing instruments, skilled manpower, measurement of exhaust emission parameters such as particulate matter (PM), CO, NOx and other pollutants as per applicable norms, preparation and submission of detailed test reports, and issuance of compliance certificate, complete all as specified and as directed by Engineer-in-Charge. Note: Testing shall be carried out through NABL-accredited / State Pollution Control Board (PCB) recognized laboratory.” BI01010001010000000000000515BI0100001234 Each Job 0.0000 Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
TENDER13.pdf
Tender Documents • 1.08 MB
BOQ_852763.xls
BOQ • 10.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .