Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | H1₹3.3 CrAdmitted-Finance H NO 28 11 DHAUJI ROAD NEAR OUR LADY ST MOUNT MARY CHURCH OLD GOA TISWADI GOA | ₹3.3 Cr | H1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Chandrashekar S Yalwar H1 |
|---|---|---|---|---|
| 1.00 | Earthwork in excavation by mechanical means (hydraulic excavator)/ manual means over areas for all leads & lifts in all types of strata comprising of any type of materials either in full or part as the case may be adopting any method/methods as may be convenient as permitted (excluding blasting) in all conditions such as dry, moist, foul, saturated, submerged etc. including dressing of sides, planking and strutting, timbering, ramming of bottom, pumping and bailing out water, barricading, danger lighting, guarding and carting away excess excavated earth at the site identified by the contractor and obtaining all statuatory approvals, as directed by engineer for 50m lead and all lifts etc complete. | 1,371 | Cu.m. | 565 ₹7.7 L |
| 2.00 | Earthwork in excavation by mechanical means (hydraulic excavator)/ manual means in foundation/pipeline trenches drains for all leads & lifts in all types of strata comprising of any type of material either in full or part as the case may be adapting any method/methods as may be convenient as permitted (excluding blasting) in all conditions such as dry, moist, foul, saturated, submerged etc. including dressing of sides, planking and strutting, timbering, ramming of bottom, pumping and bailing out water, barricading, danger lighting, guarding and carting away excess excavated earth at the site indentified by the contractor and obtaining all statuatary approvals, as directed by engineer for 50m lead and all lifts etc complete. | 378 | Cu.m. | 300 ₹1.1 L |
| 3.00 | Refilling the pipeline/foundation trenches, plinth sides, foundation, etc. with available excavated earth in layers not exceeding 20cm in depth consolidating each layer by ramming and watering lead upto 50m and all lifts and disposal of surplus earth as directed. | 1,749 | Cu.m. | 250 ₹4.4 L |
| 4.00 | Supplying and filling in plinth under floors, trenches including watering, ramming, consolidating and dressing complete with moorum | 198 | Cu.m. | 700 ₹1.4 L |
| 5.00 | Supplying and filling approved earth / hard soil obtained from contractor's identified source inclusive of obtaining all requisites statuatory approvals & observing all the security measures, with all lead and lifts, transporting to site, spreading, grading the earth/hard soil in layers not exceeding 250 mm loose layers, breaking clods & compacting including watering each layer to bring it upto to optimum moisture content to attain dry field density not less than 95% of maximum dry density (Procter Test). (Refer detailed specifications enclosed. The cost of the tests, determination of settlement of natural ground by approved method and cost towards obtaining statutory approvals for cutting/borrowing the earth shall be borne by the contractor) | 245 | Cu.m. | 1,200 ₹2.9 L |
| 6.00 | Disposal of surplus earth & debris upto all leads including loading, unloading and stacking, The site should be identified by the contractor and obtain all statuatory approval. | 293 | Cu.m. | 500 ₹1.5 L |
| 7.00 | Providing and laying autoclaved aerated concrete (AAC) blocks masonry with 100mm/125mm thick with Grade-I AAC blocks of density confirming to IS:2185 (Parts-3) in super structure above plinth level up to floor V with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of engineer-in-charge. (The payment of RCC band and reinforcement shall be made for seperately) | 46 | Cu.m. | 8,392 ₹3.9 L |
| 8.00 | Providing & laying rubble packing with hard laterite stone under floors including watering ramming and consolidating etc.in pipeline trenches and other foundations complete. | 352 | Cu.m. | 2,000 ₹7.0 L |
| 9.00 | Providing & constructing laterite masonary in neatly dressed stones of size as specified in Cement mortar 1:5 (1cement : 5coarse sand) in foundation and basement. | 23 | Cu.m. | 6,000 ₹1.4 L |
| 10.00 | Providing and laying autoclaved aerated concrete (AAC) blocks masonry with 150mm/230mm/300mm thick with Grade-I AAC blocks of density confirming to IS:2185 (Parts-3) in super structure above plinth level up to floor V with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of engineer-in-charge. (The payment of RCC band and reinforcement shall be made for seperately) | 12 | Cu.m. | 7,400 ₹88,800 |
Tender Value
₹3.0 Cr
EMD Value
₹5.9 L
Closing Date
7 Jan 2026, 5:00 pmClosed
Member Secretary, GSUDA
gsuda
Construction of Fish Market at Canacona
2026_GSUDA_27045_1
F43/3/ETENDER/34/1829 DT22/12/2025
Open Tender
Civil Works - Buildings
365 days
Canacona
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
₹5.9 L
29 Jan 2026
6 Jan 2026
8 Jan 2026
6 Jan 2026
7 Jan 2026
6 Jan 2026
Earthwork in excavation by mechanical means (hydraulic excavator)/ manual means over areas for all leads & lifts in all types of strata comprising of any type of materials either in full or part as the case may be adopting any method/methods as may be convenient as permitted (excluding blasting) in all conditions such as dry, moist, foul, saturated, submerged etc. including dressing of sides, planking and strutting, timbering, ramming of bottom, pumping and bailing out water, barricading, danger lighting, guarding and carting away excess excavated earth at the site identified by the contractor and obtaining all statuatory approvals, as directed by engineer for 50m lead and all lifts etc complete.
Earthwork in excavation by mechanical means (hydraulic excavator)/ manual means in foundation/pipeline trenches drains for all leads & lifts in all types of strata comprising of any type of material either in full or part as the case may be adapting any method/methods as may be convenient as permitted (excluding blasting) in all conditions such as dry, moist, foul, saturated, submerged etc. including dressing of sides, planking and strutting, timbering, ramming of bottom, pumping and bailing out water, barricading, danger lighting, guarding and carting away excess excavated earth at the site indentified by the contractor and obtaining all statuatary approvals, as directed by engineer for 50m lead and all lifts etc complete.
Refilling the pipeline/foundation trenches, plinth sides, foundation, etc. with available excavated earth in layers not exceeding 20cm in depth consolidating each layer by ramming and watering lead upto 50m and all lifts and disposal of surplus earth as directed.
Supplying and filling in plinth under floors, trenches including watering, ramming, consolidating and dressing complete with moorum
Supplying and filling approved earth / hard soil obtained from contractor's identified source inclusive of obtaining all requisites statuatory approvals & observing all the security measures, with all lead and lifts, transporting to site, spreading, grading the earth/hard soil in layers not exceeding 250 mm loose layers, breaking clods & compacting including watering each layer to bring it upto to optimum moisture content to attain dry field density not less than 95% of maximum dry density (Procter Test). (Refer detailed specifications enclosed. The cost of the tests, determination of settlement of natural ground by approved method and cost towards obtaining statutory approvals for cutting/borrowing the earth shall be borne by the contractor)
Disposal of surplus earth & debris upto all leads including loading, unloading and stacking, The site should be identified by the contractor and obtain all statuatory approval.
Providing and laying autoclaved aerated concrete (AAC) blocks masonry with 100mm/125mm thick with Grade-I AAC blocks of density confirming to IS:2185 (Parts-3) in super structure above plinth level up to floor V with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of engineer-in-charge. (The payment of RCC band and reinforcement shall be made for seperately)
Providing & laying rubble packing with hard laterite stone under floors including watering ramming and consolidating etc.in pipeline trenches and other foundations complete.
Providing & constructing laterite masonary in neatly dressed stones of size as specified in Cement mortar 1:5 (1cement : 5coarse sand) in foundation and basement.
Providing and laying autoclaved aerated concrete (AAC) blocks masonry with 150mm/230mm/300mm thick with Grade-I AAC blocks of density confirming to IS:2185 (Parts-3) in super structure above plinth level up to floor V with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of engineer-in-charge. (The payment of RCC band and reinforcement shall be made for seperately)
Providing & constructing laterite masonary in neatly dressed stones for 23 cms masonary walls in c.m 1:4 (1 cement : 4 coarse sand) in super structure from floor I upto floor V level
Providing & constructing laterite masonary in neatly dressed stones for 23 cms masonary walls in cm. 1:5 (1 cement : 5 coarse sand) in foundation upto plinth level
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 mm nominal size) excluding cost of centering, shuttering and finishing : all works upto plinth level
Providing & laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in - all works upto plinth level
Providing and laying upto floor V level cement concrete 1:11/2:3 (1 cement: 11/2 coarse sand: 3 graded granitic or basaltic stone aggregate 20 mm nominal size) including centering and shuttering etc. - a) Kerbs, Steps and the like at or near ground level
Providing and laying upto floor V level cement concrete 1:11/2:3 (1 cement: 11/2 coarse sand: 3 graded granitic or basaltic stone aggregate 20 mm nominal size) including centering and shuttering etc. - b) String Courses, copings, bed plates, anchor blocks, plain window sills and the like
Providing and laying upto floor V level cement concrete 1:11/2:3 (1 cement: 11/2 coarse sand: 3 graded granitic or basaltic stone aggregate 20 mm nominal size) including centering and shuttering etc. - c) Small lintels not exceeding 1.5 m clear span including coping and the like requiring formwork to the suspended portions
Centering and shuttering including strutting, propping etc. and removal of forms for a) foundation, footings, bases of columns etc.
Centering and shuttering including strutting, propping etc. and removal of forms for b) Vertical surfaces such as retaining walls, return walls, Partitions, walls (any thickness) including attached Pilasters, Buttresses, Plinth and string courses, Fillets and the like
Centering and shuttering including strutting, propping etc. and removal of forms for c) Columns, Piers, Pillars, Abutments, Posts and struts (square, rectangle polygon in plan) at all levels
Centering and shuttering including strutting, propping etc. and removal of forms for d) Sides and Soffits of beams, Beam Haunchings, Cantilever, Girders, Bressumers and Lintels plinth beams not exceeding 1m in depth at all levels
Centering and shuttering including strutting, propping etc. and removal of forms for f) suspended floors, roofs, landings, shelves and their supports, balconies and chajjas at all levels
Centering and shuttering including strutting, propping etc. and removal of forms for g) Vertical or horizontal fins individually or forming box, louvers or projected bands at all levels
Centering & shuttering including Strutting, Propping & removal of forms for sloping or battering surface (slabs, beams, louvers, etc) including folded plates - Columns, Pillars, Posts & struts (circular or curved in plan)
Providing TMT steel reinforcement bars of SAIL, TATA. VIZAG, JSW make only (Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member.
Providing and laying in position machine batched concrete (BMC), machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete work including pumping of concrete to the site of laying but excluding the cost of centering, shuttering, finishing and reinforcement including admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing the strength and durability as per the direction of the Engineer. M30 grade of reinforced cement conrete by using 390 kg of cement per cu.m. of concrete. All works at all floor levels. NOTE:- 1.Use of RMC is permitted at no extra cost. 2.Only digital weigh batcher to be used in case of batching at site.
Add for using cement than the quality as provided in the item of batch mix concrete as arrived as per the mix design
Supplying and fixing Pre-cast cement concrete kerb-stones(factory made,the factory should be ISO certified and registered under Dirctorate of Industries, Govt. of India) of M-20 with 20 mm nominal size granitic/basaltic aggregate properly consolidated by mechanical plat-form and vibrators with smooth finish including fixing at site complete as per specification. - Size 60 cm L x45 cm H x 15 cm T
Supplying and fixing of Precast RCC slabs(factory made,the factory should be ISO certified and registered under Dirctorate of Industries, Govt. of India) at site in concrete Grade of M-25 with 20 mm nominal size Granitic or basaltic aggregate, consolidated by means of mechanical platform, vibration etc. with lifting hooks of M.s. 10mm bars and PVC cups including cost of reincforcement, Certificate from manufacturer shall be produced indicating grade of concret and minimum content of steel in the product along with 5 year free replacement warranty in case of breakage complete and as directed by Engineer -in -charge. - a) Size 900 x 400 x150 mm with steel reinforcement not less than 7.0 kg per unit - 30T Capacity
Supplying and fixing of Precast RCC slabs(factory made,the factory should be ISO certified and registered under Dirctorate of Industries, Govt. of India) at site in concrete Grade of M-25 with 20 mm nominal size Granitic or basaltic aggregate, consolidated by means of mechanical platform, vibration etc. with lifting hooks of M.s. 10mm bars and PVC cups including cost of reincforcement, Certificate from manufacturer shall be produced indicating grade of concret and minimum content of steel in the product along with 5 year free replacement warranty in case of breakage complete and as directed by Engineer -in -charge. - b) Size 750 x 400 x100 mm with steel reinforcement not less than 4.2 kg per unit
Providing and fixing MS grill of required pattern in wooden frames of windows, masonry etc with MS flats, square or round bars with round headed bolts and nuts or by screws - Plain grill
Providing and fixing carbon steel galvanised (minimum coating 5 micron) dash fastner of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide PA6 grade sleeve, including drilling of hole in frame, concrete/ masonry, etc. as per direction of Engineer. - 10 x 120mm
Steel work welded (SAIL, TATA. VIZAG & using electrodes of Ador or ES4B or Deh Secheron make only) in built up sections trusses and framed work including cutting, hoisting, fixing in position and applying priming coat of red lead paint. - In Tees, angles, flats and channels
Supplying and fixing rolling shutters of approved make, made of 80 x 1.25 mm G.M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs grade No.2 and G.M.S. top cover of 1.25mm thick for folling shutterstop cover and spring.
Providing and fixing Ball bearings for rolling shutters
Providing and Fixing M. S. round holding down bolts with nuts and washer plates complete.
Providing & fixing bolts with nuts & washer complete. (Hi Tensile black bolts & nuts as per approved make)
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) (Square Hollow Section (SHS) IS4923 /Rectangular Hollow Section (RHS) IS4923/ Circular Hollow Section (CHS) IS1161 closed Structural Steel of approved make (Min Yeild Stress 310 Mpa)) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc.with hairline finish, including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Ultra-high strength, high-precision, dual shrinkage compensated, free flow cementitious grout for machine , column base plates Providing and Supplying Masterflow 928T of BASF make or equivalent approved which is dual shrinkage-compensated, cementitious grout shall be hydraulic-cement based free-flow, high strength grout that complies with ASTM C1107. The grout shall have compressive strength minimum of 35 MPa at 1 day and 75 MPa at 28 days; flexure strength minimum of 9 MPa at 28 days. The grout must exhibit positive volumetric expansion in plastic stage as well as hardening stage. Grout must be flowable at 0.15 w/c ratio and shall have fresh wet density in excess of 2200 Kg/m3. The grout must be accredited by reputed testing institute for dynamic load resistance test of 2 million cycles with no sign of cracking or strength loss. All scaffolding, ladders, supporting materials etc. complete. Rates shall be inclusive of all labour, materials, tools and plant etc. complete.
Proving & laying Kotah stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and complete with base of cement mortar 1:4 (1 cement :4 coarse sand) - 20mm thk.
Proving & laying Kotah stone slab flooring over 25 mm thick in risers of steps, skirtings, dado & pillars laid on12mm (average) thick cement mortor 1:3 (1 cement : 3 coarse sand) & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete.
Rounding of edges of marble/ Granite / Kotah slab to semi circular slope
Providing and laying jet black mirror polish granite flooring and dado over 20mm thick base of cement mortar 1:4 laid over and jointed with cement slurry including rubbling complete Granitic slab (jet black with mirror polish) 20 mm thick
Providing and laying 20mm thick cuddapah in shelves complete
Providing and fixing Kota stone tread tiles 35mm thick in single piece with rounded of nosing antiskid groove laid on and including 20mm (average) thk bed of cement slurry including pointing with pigmented cement slurry to match the shade of the slab, cleaning etc. complete.
Providing & laying 1st quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-charge in skirting, risers of steps and dados jointing with cement based high polymer modified quick-set tile adhesive (water based) conforming to IS:15477, using 5 kg. adhesive per sq.m of tile area, in average 3 mm thickness, including pointing in white cement mixed with pigment of matching shade complete. - Wall Ceramic Glazed Tiles : 300 x 450
Providing and laying Ceramic glazed floor tiles of size 300x450 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, in flooring treads of steps & landings, jointing with cement based high polymer modified quick-set tile adhesive (water based) conforming to IS:15477, using 5 kg. adhesive per sq.m of tile area, in average 3 mm thickness, including pointing the joints with white cement and matching pigment etc., complete.
Providing and laying antiskid floor tiles 12 x 12 upto 16 x 16 in of Johnson, Somany, Kajaria (thickness to be specified by the manufacturer) of 1st quality conforming to IS:15622 of approved make in shades as specified laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete - Light Shades
Providing and laying vitrified floor in different sizes of (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make in colours and shades as specified laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including grouting the joints with white cement and matching pigment etc., complete. - 600 x 600 mm light Shades
Providing and fixing Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps and dados, jointing with cement based high polymer modified quick-set tile adhesive (water based) conforming to IS:15477, using 5 kg. adhesive per sq.m of tile area, in average 3 mm thickness, including pointing/grouting in white cement mixed with pigment of matching shade complete. - 600x600 mm - light Shades
Providing and laying vitrified industrial floor tiles in different sizes of Johnson, Somany, Kajaria (thickness to be specified by the manufacturer) and conforming to IS:15622 of approved make in colours and shades as specified laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including grouting the joints with white cement and matching pigment etc., complete - 300 x 300 mm Light Shades - 10 mm thick
Providing and and laying vitrified unglazed porcelain tactile floor tiles in different sizes of Johnson, Somany, Kajaria (thickness to be specified by the manufacturer) and conforming to IS:15622 of approved make in colours and shades as specified laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including grouting the joints with white cement and matching pigment etc., complete - 300x300 Design - Liner/ Button
Providing and laying factory made Shot blasted cement concrete interlocking paver block of minimum M35 grade made by heavy duty block making machine with strong vibratory compaction and of aprpoved size and design / shape laid in 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand, etc. all complete as per the direction of Engineer.- in I, Wave, Rectangular, Square etc. shapes. The products should comply to IS 15658:2006 and manfucatured by ISO9001: 2008 certified plant. The shot blasting should be done using 0.4-0.5mm dia steel shots with a speed of 3200 rpm.60 mm thick in all colours except grey
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade, area of slab over 0.50 sqm - Jet Black
Providing and fixing in position Glass mossaic tiles at finished plain/flat/curved/inclided surface of size 10-50 mm square x 4 mm in all colour, design , fixing in customize design as per direction of Engineer. The glass mosaic tiles to be fixed on the surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer.
Vaccum dewatering of laid concrete for roads/ areas using Tremix machinery including formwork with MS channel/ angle sections on sides of concrete with proper supporting system, surface/screed & needle vibrating & levelling of concrete. Vaccum dewatering should be done using suction mats (spread on surface) & suction pump, power floating/ troweling using screen floater, manual spreading of hardening compound (if any), smooth/rough/broom finish to the required slope, camber & level, groove cutting (upto 10mm wide x50mm deep) for contraction/expansion, construction & longitudinal hoints, Providing dowel bars with sleeve/tie bars, filling two component polysuphide sealant/joint filler (Bitumen hot sealing compound: Grade A), taping with masking tape etc complete. (Concrete, reinforcement, Dowel Bar with sleeve/tie bar Reinforcement, tarpaulin sheet to be paid separately)
Providing water proofing treatment over the new RCC roofs, terrace, sunken slabs, chajjas by spreading cement slurry over the RCC slab and laying of 100 mm average laterite stone ballast coba with the necessary gradient for easy flow of rain water and the coba should be covered with damp proof, joint less water proofing plaster of mix 1:3 (1 cement : 3 Fine sand), finish smooth with wooden trowel with false marking of 30cm squares. the Vertical surfaces of the adjoining walls are to be treated upto a height of 30cms including rounding of junctions (The rate includes for complete items including labour and materials and including the cost of initial treatment of roof slab as follows. The injection of damp proof or equivalent compound with cement solution will be given as and when found necessary for filling honey comb cracks etc. in the RCC slabs) Note: The cement consumption 25 kg /sq.m.
An elastomeric, cementitious, waterproof coating for concrete and masonry. Providing and applying on a well prepared vertical surface Masterseal 550EL of BASF make or equivalent elastomeric flexible, two component polymers modified cementitious composite system that requires no addition of water at the site. The product shall be applied in minimum two coats to achieve total DFT of 1mm. The material shall be mixed and applied fully in accordance with the manufacturer's instructions. The product shall exhibit at least 40% elongation at ambient & 30% elongation in under water condition with tensile strength greater then 20 Kg/cm2. The product shall resist 1.5 bars pressure when tested as per DIN 1048 at 2mm DFT. When applied at 2mm DFT, elastomeric coating shall be able to bridge crack up to 0.5mm width. All scaffolding, ladders, supporting materials etc. complete. Rates shall be inclusive of all labour, materials, tools and plant etc. complete.
Providing and fixing colour coated galvulium roofing sheets of 0.5mm thickness including all the accessories (TATA make) but excluding the cost of purlins, rafters, trusses, flashings etc. complete as per the directions of the Engineer in charge.
Providing & fixing in position Galvalume/Zincalume flashings, cappings, ridges, gutters upto 600mm/610mm girth and min 3.00m in length (cold Rolled Steel 550 MPa yeild Stress ASTM A 446 Grade E) with hot-dip metallic coating of aluminium-zinc alloy(AZ 150 galvalume) (150 gms/sqm total of both sides with Al-Zn Composition= 55% & 43.5% resp. & 1.5% Si conforming to ASTM 792/ AS 1397) 0.45 mm base metal thickness and 0.50mm total coated thickness, factory cut at all heights for roof, side & gable cladding complete in all respects with AZ 150 GSM SMP color Coated (20mic exterior coat of Silicon Modified Polyester paint system over 5 mic primer and 5 mic polyester back coat over 5 mic primer) incl. fixing to purlins with no 12x14x55mm mechanically galvanised hex head self drilling screws of the best quality as per AS-3566 class 3-4 approved, which should be compatible to be used with sheets. with integral washers and EPDM seals etc. Silicon sealant non-hardening neutral cure type shall be applied at all end laps, complete as directed.
Providing & Fixing in position Double Skin roof with Zincalume/ Galvalume colour coated & bare profile sheet with subtle square fluting factory cut at all heights for roof, side & Gable cladding complete in all respect. TOP SHEET-The end rib shall be designed for anti-capillary action. The feed material should be manufactured out of nominal 0.45 mm Base Metal Thickness (BMT), Hi-strength steel with min. 550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% Aluminium, 43.5% Zinc &1.5% Si) as per AS 1397 - Zincalume AZ150 (Min. 150 gms/sq.mt total on both sides) with quality paint coat as per AS/NZS 2728 type 3-4. The paint shall have a total coating thickness of nominal 35 μm, comprising of nominal 20 μm exterior SMP coat on top surface and nominal 5 μm reverse backer coat on back surface over nominal 5 μm primer coat on both surfaces of approved colour shade. Total Coated Thickness (TCT) should be 0.50mm. Total Painted Thickness (TPT) should be in addition to 0.50mm. The steel sheet shall be fastened with nominal 40 μm zinc coated or nominal 25 μm zinc-tin alloy coated, Hex head, self-drilling screw as per AS 3566-2002 Class 3 fasteners of approved make with EPDM washer as per the requirement considering the profile shape and design load. The fastener size shall be calculated as per the design or manufacturers recommendations.
The profile sheet, fastener size etc. shall be approved by the Engineer. The sheeting should be with minimum 200mm lap & waterproof with Silicon sealant non-hardening neutral cure type shall be applied at all end laps, complete as directed Z-Sub Girt - roll formed section 50x50x50x1.50 TCT, 120GSM Galvanised, High Strength (345 MPa), approximate Wt. 1.85 kg/r.m. fixed with self tapping screws Glass Wool Insulation with FSK facing 50mm with 24 kg/m3 density in between 2 sheets. LINER SHEET-bare galvalume/zincalume roofing sheet of same profile as top sheet. The feed material is of manufactured out of nominal 0.45 mm Base Metal Thickness (BMT) (0.47 mm TCT), Hi-strength steel with min. 550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% Aluminium, 45% Zinc) as per AS 1397 - Zincalume AZ150 (Min. 150 gms/sq.mt total on both sides), passivated & resin coated. The feed material should have coil manufacturer’s product details marked at regular interval for confirming genuinity of the material. complete as per the directions of the engineer. The steel manufacturer's test certificate for the chemical & mechanical properties of steel must be submitted for approval prior to installation.
Providing and fixing 600mm throat width ridge gravent system along ridges. Construction:- Gravent system should be constructed in 2mm thick GI L angles which should be fixed on the Roof purlins at a distance of 815mm C/C (or as per manfacturers specifications) along the ridge line. All the other accessories like flashing, side flates, rain cap, wind band should be manufaured from 0.47mm thick hi-tensile Bare Galvalume steel (AZ-150 gsm. Aluminium-zinc alloy metallic coating of total both sides 550 MPa yield stress as per AS – 1397 or ASTM-792 A). Top surface above the ridge flashing has to be coved using the SS bird mesh of required. Sealants should be applied to all the Galvalume sheet joints and to the riveted places and ensure that entire system should be watertight including work at all levels and heights etc., complete.
Providing and applying white cement based putty of average thickness 1.00mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
12mm cement plaster 1:4 (1cement: 4 fine sand)
6mm cement plaster to ceiling 1:3 (1 cement : 3 fine sand)
neat cement punning
Extra for providing and mixing water proofing material proportion recommended by the manufacturers. b) 12mm cement plaster 1:4 (1 cement : 4 sand)
18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge including providing and mixing water proofing material proportion recommended by the manufacturers.
12mm thick molded cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand) cm per meter
Applying priming coat with ready mixed primer of approved brand and manufacture on steel work.
Painting two or more coats (excluding priming coat ) with superior quality ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give a even shade
Painting(two or more coats) with synthetic enamel paint of approved brand and manufacture in all shades on new work over and under coat of suitable shade with ordinary paint of approved brand and manufacture
Wall painting (two or more coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade (including min two priming coats and two layers of putty alternatively)
Painting three or more coats with acryllic exterior paint of approved brand and manufacture (such as weather shield, Apex) including applying one coat of cement primer and one coat of surface treatment etc. complete.
Painting one or more coats of acryllic exterior paint of approved brand and manufacture (such as Dulex/ Asian Paints/ Sherwin Willians) on old work including cleaning the surface with water etc. complete.
Applying breathable, non-reactive, antifungal, and water repellant Silane/ Siloxane chemical as approved by Archaeological Survey of India/ Engineer, of approved brand and manufacture, diluted with solvent mineral Turpentine oil in the ratio of 1:12 (One part of approved chemical :12 Part of Turpentine oil), on the exposed laterite masonry surface with two or more coats to give uniform application of chemical on the surface, all complete as per direction of Engineer. (The rate is inclusive of all materials & labours).
Providing and fixing weepholes with rigid PVC make laid in position with a required slope and level while laying pipes of approved the concrete of retaining wall,wing wall and earth retainig structure complete as directed by the Engineer in charge - 110mm dia
Providing and laying filter media with Granular materials crushed stone Aggregates satisfying the rerquirement As Per Clause 2504.2.2 of MOSRT & H Specification to a thickness of 500 mm laid horizontally in layers of 250mm thick and compacted to firm condition etc. complete as direction by Engineer-in-charge.
Providing and fixing Rigid PVC (SELFIT) pipes for public water supply including Railway freight, carting, loading and unloading, stacking, transit insurance etc, conforming to ASTM 2467 with ISO 14001, including all PVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer.conforming to IS 4985-2000 and bearing ISI mark, CLASS 6 KG/ SQ. CM a) Outer dia 63 mm
Providing and fixing Rigid PVC (SELFIT) pipes for public water supply including Railway freight, carting, loading and unloading, stacking, transit insurance etc, conforming to ASTM 2467 with ISO 14001, including all PVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer.conforming to IS 4985-2000 and bearing ISI mark, CLASS 6 KG/ SQ. CM b) 75 mm
Providing and fixing Rigid PVC (SELFIT) pipes for public water supply including Railway freight, carting, loading and unloading, stacking, transit insurance etc, conforming to ASTM 2467 with ISO 14001, including all PVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer.conforming to IS 4985-2000 and bearing ISI mark, CLASS 6 KG/ SQ. CM c) 110 mm
Providing and fixing Rigid PVC (SELFIT) pipes for public water supply including Railway freight, carting, loading and unloading, stacking, transit insurance etc, conforming to ASTM 2467 with ISO 14001, including all PVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer.conforming to IS 4985-2000 and bearing ISI mark, CLASS 6 KG/ SQ. CMd) 140 mm
Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step UPVC solvent cement and testing of joints complete as per direction of Engineer. Internal work - Exposed on wall. SCH-40 (blue)/(white) - 25mm outer dia.
Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step UPVC solvent cement and testing of joints complete as per direction of Engineer. Internal work - Exposed on wall. SCH-40 (blue)/(white) - 32mm outer dia
Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step UPVC solvent cement and testing of joints complete as per direction of Engineer. Internal work - Exposed on wall. SCH-40 (blue)/(white) - 40mm outer dia
Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step UPVC solvent cement and testing of joints complete as per direction of Engineer. Internal work - Exposed on wall. SCH-40 (blue)/(white) - 50mm outer dia.
Providing & fixing G.I. pipes (B class) complete with G. I. Fittings including trenching and refilling etc. (External work) - 15mm nominal bore
Providing & fixing G.I. pipes (B class) complete with G. I. Fittings including trenching and refilling etc. (External work) -32mm nominal bore
Fixing water meter and stop cock in G.I. Pipe line including cutting and threading the pipe and making long screw etc. complete ( cost of water meter and stop cock to be paid separately.
Providing and fixing brass stop cock (heavy) of approved quality - 20mm nominal bore
Providing and fixing brass stop cock (heavy) of approved quality25mm nominal bore
Providing and fixing brass stop cock (heavy) of approved quality 32mm nominal bore
Providing and fixing brass stop cock (heavy) of approved quality 40mm nominal bore
Providing and fixing brass stop cock (heavy) of approved quality 50mm nominal bore
Providing and fixing brass full way valve (heavy duty) with wheel of approved quality - 20mm nominal bore
Providing and fixing brass full way valve (heavy duty) with wheel of approved quality -25mm nominal bore
Providing and fixing brass full way valve (heavy duty) with wheel of approved quality -40mm nominal bore
Providing and fixing brass full way valve (heavy duty) with wheel of approved quality - 50mm nominal bore
Providing and fixing ball valve (brass) of approved quality High pressure with P.V.C. floats - 20mm nominal bore
Providing and placing on terrace roof of floor two (1st floor roof single piece rotational moulded polythene water storage tank having I S I mark and conforming to I S 12701; 1996.- 1000 lit capacity
Providing and fixing square-mouth S.W. gully trap grade ‘A’ complete with C.I grating brick masonry chamber and water tight C.I. cover with frame of 300 x 300 mm size (inside the weight of cover to be not less than 4.53 kg). And frame to be not less than 2.72 kg as per standard design - 150 x 100 mm size – P or S type
Constructing brick masonry manholes or inspection chamber with second class bricks in cement mortar 1:5 (1 Cement : 5 Fine Sand), RCC top slab 1:1.5:3 mix (1 Cement :1.5 Coarse Sand : 3 graded stone aggregate 20mm nominal size) Foundation concrete 1:1.5:3 (1 Cement :1.5 Coarse Sand : 3 graded stone aggregate 20mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 Cement : 3 Coarse Sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4mix (1 Cement :2 Coarse Sand : 4 graded stone aggregate 20mm nominal size) neatly finished complete as per standard design. a) Inside size 90x80 cm and 60 cm deep including Supplying and fixing at the site of work of Steel Fibre Reinforced Concrete (SFRC) manhole covers with frames made as per IS :12592 (part I and II) - 1991 in concrete M45grade. The covers and lapped in 2mm thick. steel plate and this plate & lifting hooks are duly painted in corrosion resistant epoxy paint etc. complete. Light Duty (2.50 Metric Tonne Capacity) a) 450x900
Constructing brick masonry manholes or inspection chamber with second class bricks in cement mortar 1:5 (1 Cement : 5 Fine Sand), RCC top slab 1:1.5:3 mix (1 Cement :1.5 Coarse Sand : 3 graded stone aggregate 20mm nominal size) Foundation concrete 1:1.5:3 (1 Cement :1.5 Coarse Sand : 3 graded stone aggregate 20mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 Cement : 3 Coarse Sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4mix (1 Cement :2 Coarse Sand : 4 graded stone aggregate 20mm nominal size) neatly finished complete as per standard design. b) Inside size 60x60 cm and 60 cm deep including Supplying and fixing at the site of work of Steel Fibre Reinforced Concrete (SFRC) manhole covers with frames made as per IS :12592 (part I and II) - 1991 in concrete M45grade. The covers and lapped in 2mm thick. steel plate and this plate & lifting hooks are duly painted in corrosion resistant epoxy paint etc. complete. Light Duty (2.50 Metric Tonne Capacity) b) 450x600
Supplying and fixing at the site of work of Steel Fibre Reinforced Concrete (SFRC) manhole covers with frames made as per IS :12592 (part I and II) - 1991 in concrete M45grade. The covers and lapped in 2mm thick. steel plate and this plate & lifting hooks are duly painted in corrosion resistant epoxy paint etc. complete. Light Duty (2.50 Metric Tonne Capacity) a) 450x600 mm
Making soak pit 2.5m dia, 3.0m deep with 45 x 45 cm dry brick honey comb shaft and sw drain pipe 100m dia, 1.8 m long complete. Filled with laterite stone aggregate 125 to 180 mm surrounded by laterite stone aggregate of 200 mm and down guage as per standard design
Providing & fixing rigid PVC SWR (soil, waste and rain water drainage pipes of approved make including lubricant etc. complete ( single/double socketed) - 110 mm dia
Providing & fixing rigid PVC SWR (soil, waste and rain water drainage pipes of approved make including lubricant etc. complete ( single/double socketed) - 75 mm dia
Providing & fixing rigid PVC bend (approved make) for SWR pipes including lubricating etc. complete bend with door - 110 mm dia
Providing & fixing rigid PVC bend (approved make) for SWR pipes including lubricating etc. complete bend with door - 75 mm dia
Providing & fixing single Tee of rigid PVC (approved make) for SWR pipes including lubricating etc. complete bend with door - 110 mm dia
Providing & fixing single Tee of rigid PVC (approved make) for SWR pipes including lubricating etc. complete bend with door -75 mm dia
Providing and fixing single “Y” of rigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete, with door - 110 mm dia
Providing and fixing single “Y” of rigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete, with door -75 mm dia
Providing and fixing double “Y” of rigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete, with door - 110 mm dia
Providing and fixing double “Y” of rigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete, with door -75 mm dia
Providing & fixing Nahani trap of rigid PVC of (approved make) for SWR pipes including lubricating etc complete with SS door - 75mm dia
Providing & fixing U.P.V.C. pipe clips (approved make) for S.W.R pipe - 110mm
Providing & fixing U.P.V.C. pipe clips (approved make) for S.W.R pipe - 75mm dia
Providing and fixing NICKEL chrome plated copper alloy Fancy BIB Cock Short Body Jaquar make or equivalent. Confirming to IS 8931;1993 - 15mm nominal bore
Providing and fixing NICKEL chrome plated copper alloy Fancy long body bib cock with wall flance Jaquar make or equivalent. Confirming to IS 8931;1993 - 15mm nominal bore
Providing and fixing NICKEL chrome plated copper alloy Fancy ANGULAR STOP COCK WITH SLINDING FLANCE 15MM Jaquar make or equivalent. Confirming to IS 8931;1993 - 15mm nominal bore
Providing and fixing NICKEL chrome plated copper alloy Fancy CONCEALED STOP COCK WITH SLINDING FLANCE 15MM Jaquar make or equivalent. Confirming to IS 8931;1993 - 20mm nominal bore
Providing and fixing P.V.C. connection pipe with brass unions 15 mm nominal bore - a) 30 cm (12") length
Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer. Concealed work (medium duty SDR 13.5 pipe) including cutting chases and making good the walls etc. - 15 mm dia nominal outer dia pipes.
Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer. Concealed work (medium duty SDR 13.5 pipe) including cutting chases and making good the walls etc. - 20 mm dia nominal outer dia pipes.
Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer. Concealed work (medium duty SDR 13.5 pipe) including cutting chases and making good the walls etc. - 25 mm dia nominal outer dia pipes.
Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including jointing of pipes & fittings with one step UPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer. External work. SCH-40 (blue)/(White) - 20mm outer dia.
Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including jointing of pipes & fittings with one step UPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer. External work. SCH-40 (blue)/(White) - 25 mm dia nominal outer dia pipes.
Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including jointing of pipes & fittings with one step UPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer. External work. SCH-40 (blue)/(White) - 32 mm dia nominal outer dia pipes.
Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including jointing of pipes & fittings with one step UPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer. External work. SCH-40 (blue)/(White) - 40 mm dia nominal outer dia pipes.
Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including jointing of pipes & fittings with one step UPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer. External work. SCH-40 (blue)/(White) - 50 mm dia nominal outer dia pipes.
Supplying & Fixing C.I. Foot valve with metal valve and seat full bore type, having total area through strainer perforations three times that of pipe size suitable for working pressure of 2 kg/sq.cm. As per IS: 4038 (lift type) - 50 mm dia
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 including cutting of stone and making good the walls wherever required. Kitchen sink without drain board. with coupling & all accessories complete with choke stop strainer, Plain type having flat borders for correct sandwithing between the plaform top and bottom slabs complete - Overall size 535mmx460mm (21"x18") bowl size 460mmx380mmx200mm (18"x 15"x 8") depth 200 mm. Glossy. 1.0mm thk,
Construction of meter box of size1.00x0.45x0.90 m in laterite stone masonry in cement mortar1:5 (1cement :5coarse sand). Foundation concrete of 8cm thick 1:4:8 (1 cement : 4 coarse sand : 8 graded granitic or basaltic stone aggregate 40mm nominal size) RCC top slab 8cm thick 1:2:4 (1Cement:2 coarse sand:4 graded granitic or basaltic stone aggregate 20mm nominal size) including high yield steel bars 8mm dia. 4 nos. each in both directions finished with 12mm thick cement plaster 1:6 (1 cement:6 coarse sand) including white washing with lime, two or more coats to give an even shade. Providing & fixing door cover of mild steel angle frame of size 20mmx20mmx3mm including necessary hinges and holdfast of size 100mmx20mmx3mm (2 Nos.), paintings etc. complete as directed by the Departmental Officer (rate inclusive of earthwork in excavation, rubble packing 10cm thick, refilling of excavated earth etc. complete as per the standard drawing). In the various Scattered locations as per the direction of the Engineer -in-charge
Providing anti termite treatment to the building conforming to IS:6313 (part II) 1971 adopted, including adopting the precautions for health hazards and safety measures as required therein with the cost of all materials, chemicals plants, equipments etc required for the treatment and furnishing a guarantee for a minimum period of 10 years from the date of completion including eradicating any infestation of termite free of cost during the guarantee period complete. The payment will be made on the Plinth of the building) - Preconstruction
Proving and laying 120 microns waterproof plastic film/sheet as per IS 14611-1998 as a separation/slip membrane laid flat without creases and with minimum overlap of 200mm at joints, nailed to underneath Plain Cement concrete, if required as directed.
Providing and fixing in position terracotta jallis as per specified size, pattern and colour, all complete. The jalli size of 200-220x200-220x60-63mm with size accuracy of +/-5% and should be suitable for exterior use with less than 6% water absorption capacity. The jalli should be fire resistant, with anti skid and scratch resistant properties. There should be uniformness in colour texture and colour should not fade after exposure to sunlight. The jallis are to be fixed like bricks stacked on each other with adhesives and stiffeners are to be embedded in the jalli to provide strength. The installation process should be as specified by the manufacturer with special tile adhesive approved by the Engineer incharge. Preparation of the surface should be as per manufacturers instructions and specifications. The surface of the jalli has to be cleaned of any residual adhesive soon after installations to give it a clean and neat look. MS plate 40mmx5mm has to be placed at every third layer and welded to MS Hollow section which has to be provided on sides, as per attached drawing. (MS will be paid separately) complete.
Providing and fixing in position terracotta brick tiles wall cladding as per specified size, pattern and colour, all complete. The tiles size of 240x60/75x9/10mm with size variation of +/-2mm/ thickness variation +/-1mm and should be suitable for exterior use with less than 8% water absorption capacity. The tiles should be fire resistant A1, with anti skid and scratch resistant properties (MOH Harderness 5). There should be uniformness in colour texture and colour should not fade after eposure to sunlight. The tiles are to be fixed with 4 to 6mm spacers as specified by the manufacturer. Jointing with cement based high polymer modified quick-set tile adhesive (water based) conforming to IS:15477, using 5 kg. adhesive per sq.m of tile area, in average 3 mm thickness, including pointing in white cement mixed with pigment of matching shade complete. Preparation of the surface should be as per manufacturers instructions and specifications. The surface of the tiles has to be cleaned of any residual adhesive soon after installations to give it a clean and neat look.
Providing & Fixing Signage made of 6mm thick transperent/ coloured acrylic sheet base material. The graphic should be computer cut self adhesive vinyl covered with clear vinyl to protect from peeling. The signage should be fixed with 12mm dia S.S. studs or S. S. Mirror screws.
Providing and fixing signages made from aluminium composite panel 4mm thk. base material with computer cut self adhesive vinyl graphic covered with clear vinyl to protect from peeling. The signage shall be fixed with 12mm dia S.S. studs or S.S. mirror screws.
Providing & Fixing in position Autoglow photoluminescent Signage made of 1.5mm thick Rigid sheet as base material. The colour, text, size graphic symbol should be as specified by the Fire and Safety Department and IS code 12349(1988) (Reaffirmed 2002) . The signages should be approved by the engineer in charge. The signage should be fixed with 12mm dia S.S. studs or S. S. Mirror screws.
Providing & Fixing Backlit LED (6500k, 2W), double sided Emergency Escape Signages showing directional arrow, text and size as directed by engineer in charge. It should contain powder coated steel/ Aluminium fabricated frame. It should have provision to Hang to ceiling with the help of SS chain at both ends. Operating voltage 230VAC/24VDC/ 12VDC with battery operated.IT should have rechargeable battery with back up time more than 90 minutes. IP20 rating. approx size 320x 170x35mm.
Providing and Fixing in position with all necessary accessories, stainless steel floor grating of size 150x 600mm size. Grating to made of SS304 grade and 1.50mm thick
Demolishing cement concrete 1:3:6 or richer mix including disposal of material within 50 m lead.
Demolishing R.C.C. work including stacking of steel bars & disposal of unserviceable within 50 mts. lead.
Demolishing brick work in cement mortar including stacking of serviceable material& disposal of unserviceable material within 50 mts. lead.
Demolishing laterite stone masonry in cement mortar including stacking of serviceable material & disposal of unserviceable material within 50 mts. lead.
Dismantling doors, windows and clearestory windows (steel or wood) shutters including chowkhats architrave holdfast etc. complete and staking within 50 mt. Lead - Of area 3 sq.m. and below
Dismantling steelwork in single sections in channels,angles, tees,flats including dismembering and \taking within 50 mts. Lead
Dismantling steelwork in built up sections in angles, tees, flats and channels including all gusset lates bolts, nuts, cutting dismembering and staking within 50 mts. Lead
Dismantling the tile work in floors and roofs laid in cement including stacking of materials within 50 meters lead for thickness of tiles 10mm to 25mm.
Dismantling asbestos sheet roofing including ridges, hips valley and utters and stacking the material within 50 meters lead.
Dismantling precast concrete or stone slabs in walls, partition walls etc. including stacking within 50 meters lead. Thickness upto 38mm
Dismantling of existing G.I. Pipe including disposal of unserviceable material and stacking of serviceable materials a) upto 20mm nominal bore
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete wood work, steel work, including T & P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metresas per MORTH 202 - Dismantling stone pitching/dry stone spalls
Dismantling the existing light, fan, bell, clock, independent plug point, wiring including circuit mains of all types along with accessories etc.complete as per specification No: WG-DM/PW
Dismantling the existing Aluminium/copper mains,submains wiring upto 10 sq.mm. along with accessories etc.Complete as per specification No: WG-DM/PW
Dismantling of existing fluorescent fitting of any type & size
Dismantling the existing switchgears, DB, and Bus bar of any size complete with/ without board or angle iron frame
Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
Supplying, erecting testing and commissioning Manual Call Point with break glass, push button (Resettable Type) in metal enclosure complete as per specification no. FF-FAAS/MCP
Supplying, erecting, testing and commissioning hooters having high (100dB @ 1m) and low (94dB @ 1m) volume setting, group addressing facility allowing multiple sounders to be activated with CRCA enclosure complete as per specification no. FF-FAAS/HTR
Supplying and fixing of following sizes of rigid PVC conduit alongwith accessories in surface(medium)/recess(heavy) including cutting the wall and making good the same in case of recessed conduit as required. - 25 mm
Supplying, installing, testing and commissioning FRLS, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CBLT/CU
Supplying, installing, testing and commissioning 2 Zone, local signal conventional control panel (LCP) with standard accessories complete as per specification no. FF-FAAS/LCP
Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP
Providing coating of bitumen paint & pipeline corrosion resistant Pypkote tape conforming to IS 10221 Appendix B specification having 4mm thick wrapping for underground 100 mm ring main of fire fighting system. (Pypkote tape comprises of a Tar based Polymeric mix supported on a fabric of high tensile strength Fibreglass).
Providing coating of bitumen paint & pipeline corrosion resistant Pypkote tape conforming to IS 10221 Appendix B specification having 4mm thick wrapping for underground 150 mm ring main of fire fighting system. (Pypkote tape comprises of a Tar based Polymeric mix supported on a fabric of high tensile strength Fibreglass).
Supplying and erecting cast iron double flange sluice valve 100 mm dia. as per specification No. FF-VL/SV
Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FFVL/BFV
Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FFVL/BFV
Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FFFFA/NZ
Supplying and erecting M.S./CRCA cabinet for housing double hose pipe with nozzle (size 750 x 600x 250 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8"x6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit (heavy) with modular switch, modular plates, suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (a) Group C -- with Cat B Modular Accessories
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface PVC conduit (medium) with modular switch, modular plates, suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (a) Group C -- with Cat B Modular Accessories
Wiring for group controlled light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface PVC conduit( medium) and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required - Cat B
Supplying and fixing suitable size modular GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/ 6 A modular switch connection painting etc. as required. - Cat B
Supplying and fixing suitable size modular GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 15/16 A and 5/6 A modular socket outlet modular socket outlet and 15/16 A modular switch connection painting etc. as required. - Cat B
Supplying and fixing modular blanking plate on the existing modular plate switch box excluding modular plate etc. as required - Cat B
Supply and erecting fan hook box (100 mm diameter or equivalent square size, 75mm deep) fabricated out of 16 SWG sheet steel with 10 m round bar hook bounded to RCC steel upto 50 mm length protruding on each side of the box, including painting with 2 coats of red oxide, complete as required.
Supply and erecting 'J' type Mild Steel fan hook fabricated out of 35 X 6 mm flat strip suitable for rafters complete with coach screws etc as required. (a) For 6 inches rafter size
Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.
Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF
Supplying and erecting Street light bracket for erection of side entry fitting on pole with 25 mm. dia. ‘B’ grade G.I. pipe of required length complete as per specification no. FG-BKT/SLB
Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FGODF/SL.
Supplying and erecting integrated LED flood light fitting Max. 30W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 3000 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs at L70B50 including driver with U shaped bracket with minimum 2 Years warranty as per specification No. FGODF/FL.
Supplying and erecting integrated LED flood light fitting Max. 50W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 5000 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs at L70B50 including driver with U shaped bracket with minimum 2 Years warranty as per specification No. FGODF/FL.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit (heavy) of appropriate size as required. (a) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire (20mm Conduit)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit (heavy) of appropriate size as required.(b) 2 x 4 sq.mm + 1 x 4 sq.mm earthwire (20mm Conduit)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit (heavy) of appropriate size as required.(c) 2 x 6 sq.mm + 1 x 6 sq.mm earthwire (25mm Conduit)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit (heavy) of appropriate size as required.(d) 4 x 6 sq.mm + 2 x 6 sq.mm earthwire (32mm Conduit)
Supplying and fixing following way SPN sheet steel MCB distribution board 240 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required (but without MCB/RCCB/Isolator) (a) 8 way double door Cat B
Supplying and fixing following way TPN sheet steel, double door, Horizontal type MCB distribution board 415 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required (but without MCB/RCCB/Isolator). (a) 4 way (4+12), double door, Horizontal type Cat B
Supplying and fixing 6 A to 32 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.(a) SP, Cat B
Supplying and fixing 6 A to 32 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.(b) DP, Cat B
Supplying and fixing 40 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.. - TPN, Cat B
Supplying and fixing SP blanking plate in the existing MCB DB complete as required
Supply and providing Chemical earthing system (Pipe in pipe type) with Outer pipe of the electrode having minimum 80mm diameter as per the enclosed specifiations and drawing.The outer and the inner hot dip galvanised MS pipes shall conform to the specifications and the space inbetween shall be filled with highly crystalline conductive and anti- corrosive mixture conforming to IS-3043. The earth electrode shall be CPRI tested.The scope of work includes boring (300mm dia mimnimum)/excavation of soil/hard rock, refilling with required quantity of back fill compound/Ground resistance enhancement powder of requisite quantity, compaction, constuction of masonary chamber etc complete as required to obtain the desired value. Aluminium tag with embossed earthing value shall be permanently attached to the pipe electrode: - 2 metres length electrode
Supplying and laying 25 mm x 5 mm GI strip at 0.5 m below ground as strip earth electrode including soldering etc. as required
Providing and fixing 25 mm x 5 mm GI strip on surface or in recess for connections etc. as required
Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554 (Part I) , IS:7098(Part I) with latest amendments of following size:- 3 1/2 Core 70 sq.mm
Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. - 3 1/2 x 70 Sq. mm.
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. - In Soily Strata
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 400 sq.mm in the existing masonry open duct, etc. complete as required
Supply and fixing of cable route marker 15 cms diameter of GI plate 6mm thick with inscription theron bolted or welded to 25mm x 25mmx 5mm angle iron 60 cms long and fixing the same in ground with PCC etc complete as required.
Supply, Fabrication, Erection, Testing & Commissioning of Main Panel floor mounted with frame of suitable M.S. channel dully painted, fabricated of 14/16 swg CRCA sheets completely derusted, chemically treated and powder coated with shade suggested by client and having following items as per single line diagram:- 100A, 25KA, Adjustable TP MCCB - 1 no. wiring for ammeter having Three & half digit LED display, external C.T. operated, calibrated for suitable to operate on 500V, 0 to 1000A AC supply, L.T. Current Transformer with bar primary 50/5 to 1000/5 ratio with 15VA, 3 pilot lamps LED with colour glasses with miniature lamps 230 V/250V from GED connected to 100A, 4P alluminium busbar with outgoing of 16 nos 10 - 40A KWH meter with 25A, SP, MCB & 1 no 10 - 40A KWH meter with 40A, TP, MCB., 1 meter as per single line drawing of MLTP
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
Tendernotice_2.pdf
PDF • 3.86 MB
Tendernotice_3.pdf
PDF • 1.09 MB
BOQ_27493.xls
BOQ • 0.50 MB
Download all tender documents and submit your bid