| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.4 CrAccepted-AOC | ₹1.4 Cr | 1 | Accepted-AOC Being lowest and reasonable rates |
| 2 | 2₹1.5 Cr+₹6.6 L (4.73%)Rejected-Finance 04 L BLOCK MARKET SECTOR 11 NOIDA 201301 UP GAUTAM BUDHA NAGAR | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | ₹1.5 Cr+₹6.6 L (4.73%) | 2 | Rejected-Finance Not being lowest tenderer |
| 3 | 3₹1.5 Cr+₹7.2 L (5.13%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | ₹1.5 Cr+₹7.2 L (5.13%) | 3 | Rejected-Finance Not being lowest tenderer |
| 4 | 4₹1.5 Cr+₹9.7 L (6.91%)Rejected-Finance | ₹1.5 Cr+₹9.7 L (6.91%) | 4 | Rejected-Finance Not being lowest tenderer |
| 5 | 5₹1.5 Cr+₹9.7 L (6.93%)Rejected-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | ₹1.5 Cr+₹9.7 L (6.93%) | 5 | Rejected-Finance Not being lowest tenderer |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
2 May 2022, 6:00 pmClosed
HQ CWE (U) DELHI CANTT
HQ CWE (U) DELHI CANTT
PROVISION OF DG SET AT HQ DGBR DELHI CANTT UNDER GE(U) ELECT SUPPLY, DELHI CANTT-10
2022_MES_516565_1
CA NO CWE(U)/D-01/2022-23
Open Tender
Civil Works
Item Rate
180 days
DELHI CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
Yes
GE(U) ELECTRIC SUPPLY, DELHI CANTT -110010
₹2.2 L
Yes
24 May 2022
5 Apr 2022
4 May 2022
5 Apr 2022
2 May 2022
26 Apr 2022
Amount
Supply, Installalation and testing of water cooled Diesel Engine driven Prime duty Generating Set of capacity after all derating factors net of not less than 750 KVA/ 600 KW ,50Hz 415 volt 3 phase, 4 wire,0.8 lagg, 891 BHP minimum Required Power for Rated KVA (bhp) along with AMF system with Acoustic Enclosure as per CPCB Norms, exhaust silencer-Hospital Grade in line including following
Engine comprising of the following: Rugged engine natural liquid cooled (EG Compleat 50:50) with radiator as secondary media with world class OEM powered diesel generator set Advanced in-cylinder technology turbo charged , air cooled aspriated to meet latest emission norms without any after-treatment device. Class defining technology engine is designed to meet stringent exhaust emission tests as per revised MoEF norms, thus offering environment friendly powe Compact in size with optimum power to weight ratio, 12 cylinder, In-line 4 stroke, radiator cooled engine Well designed air handling system with Dry type, heavy duty, replaceable paper element aircleaner with restriction indicator, Air to air after cooling,Optimised turbocharger for increased altitude capabilities, Best in class fuel economy with Inline fuel pump with A1 class mechanical governing, Spin on fuel filter, Standard integral set-mounted radiator system, designedand tested for 50°C ambient temperature,Full flow spin on lube oil filte,First fill of lube oil and coolant, Electrical starter motor with soft start engagement feature, Battery charging alternator,1 x 12 V DC battery /Alternator
Alternator PMG type comprising of the following: Alternator frames from Cummins Generator Technologies Brushless type, Screen protected, Revolving field, Self excited alternator conforming to IS/IEC 60034-13 Phase reconnectable winding with 12 terminals brought out for connection Dedicated winding specially designed for 1 phase / 3 pahse operation Better motor starting capability Best in class efficiency Compact design with sealed bearings for longer life andlesser maintenance Impregnation on all wound components for better mechanical strength, alternator of IP 23, Voltage regulation (Max.)±1%,Class of Insulation H Class, Winding Pitch 2/3,Stator Winding Double layer lap Rotor Dynamically Balanced,Waveform distortion/ Total Harmonic Distortion No load < 1.5 %, Non distorting balanced linear load < 5 %,Maximum Unbalanced Load across phases less than or equal to 25%, Telephonic Harmonic factor < 2% alternator capcity out put shall not be less than 750 KVA /600 KW ,50Hz 415 volt 3 phase, 4 wire,0.8 lagg. 1043Amp / phase
Control Panel comprising of the following: AMF / Control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish.The control panel consists of the following parts of makes as per OEM recomendation: microprocessor based generator set monitoring and control system. AMF Functionality is inbuilt and this control includes an intuitive operator interface that allows for complete generator set control as well as system metering, fault annunciation, configuration, and diagnostics, Copper bus bars with suitable capacity with incoming/outgoing terminals, Indicating lamps for ‘Load ON’ and ‘Set Running’,Instrument fuses / MCBs duly wired and ferruled, Circuit breakers of suitable rating with overload and shortcircuit protections. with motorised change overs /on load power contactors with copper busbars, cables and protective acessories with load / bypass arrangements
Hospital grade silencer : silencer suitably optimized to meet stringen noise emission standards laid down by MoEF / CPCB along with MS supporting structures .along with thermal Insulation on horizontal pipe with Mineral Wool/ Asbestos Rope 50mm Thick wire mesh and 26 gauge aluminium cladding (12")
Controller should be compatable to the following specifications: (i) AMF Functionality controllers of Makes from the OEM (II) Intuitive operator interface which includes LED backlit display with tactile feel soft-switches.Indications - Generator set, Utility Status Lamp. (iii) Remote start-stop with Engine Metering: Oil pressure, Engine temperature, Startingbattery voltage, Engine running hours (iv) AC Alternator Metering: L-L Voltage and L-N Voltage,Current (phase and total), kVA (phase and total) andFrequency. kwh, Total & per phase (kw & kVA), PF, UtilityVoltage and Freq. (v) Engine Protection: Low lube oil pressure, High/Low coolant temperature, Battery Over/Under/Weak Volts, Fail to Crank/ Start, Sensor failure, Cranking lockout, Low fuel level. (vi) AC Alternator Protection: Over/Under Voltage, Over /UnderFrequency, Loss of AC sensing. Overspeed, Over Current. (vii) Data Logging: Engine hours, Control hours and upto 5 recent fault codes (viii) Configurable glow plug control, Cycle Cranking (ix) 12/24 Volt DC operation,Sleep mode,Modbus interface (RS485 RTU),In Power compatible (PC based service tool),Certifications - meets the requirement of relevant ISO, EN, Mil Std. and CE standards (x) Maintenance due alarm based on Engine Run Time and duedate,Exercisor scheduler (xii) Remote HMI, Digital electronic governor with temperture compensation and smooth starting, digital AVR for shunt of PMG excitor with Torque monitoring, Digital electronic governor with temperture compensation and smooth starting, digital AVR for shunt of PMG excitor with Torque monitoring
All pipe line connections, valves etc.required for the lube oils, fuel and cooling system
Battery & Battery charger of rated capacity as per the alternator/ Engine compatability
Mounting Arrangement shall be of the following: (i) Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. (ii) Base frame with integral fuel tank is provided with drainplug, air vent, inlet and outlet connection, level indicator and provision for cleaning
Fuel Tank of capacity 12 hrs running capacity along with Fuel pipe MS class 25mm ID with bends , flanges , valves, tees and bends.
Residnetial type silencer with MS pipe as designed by the OEM horizontal Exhaust pipe complete with bends and flanges of adeeaquate length not less than 10 Mtr.along with thermal Insulation on horizontal pipe with Mineral Wool/ Asbestos Rope 50mm Thick wire mesh and 26 gauge aluminium cladding (12")
Controll / service cables shall be of 4 x 2.5 sqmm, 24 x 2.5 sqmm , 2 x 2.5 sqmm, and 8 x 0.75 sqmm shielded control cables ,pvc insulated copper armoured, controll panel for auxilaries with starters for pumps,heaters etc
RCC foundation with necessary earth work ,PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in foundation, filling and mass concrete / RCC M-30 (20 mm graded aggregate) as in foundations, Plinth beam along with necessary form work / TMT bars of 10mm dia and over cut to length bend to shape required including cranking, bending, spirally for hooping for columns, hooking ends and bidning with and including MS wire (annealed) not less than 0.9mm dia securing with clips / 10 mm thick plastering on fair faces of brick work or concrete surface in CM (1:6),even and smooth without using extra cement / Sand filling in layers around the foundation including watering and consolidation as per OEM dimensions
(l) Acoustic Enclosure shall comprise of the following (i)Specially designed to meet stringent MoEF/ CPCB norms of 75 dBA @ 1mtr at 75% load under free field conditions (ii)The Acoustic Enclosure as per CPCB Norms is made of CRCA sheets in Munselgreen shade and a structural/ sheet metal base frame painted in black. or any other standard colour as specified by the OEM (iii)High quality noise absorbant and fire-retardant grade acoustic insulation material (P.U. Foam) complying to IS8183 designed to have optimum serviceability (iv)Air inlet louvers specially designed to operate at rated load, Made on special purpose CNC machines for consistency inquality and workmanship (v)11 tank pretreatment process and UV resistant powder coating of all parts to withstand extreme environment, Use of special hardware for longer life, Flush styling - no projections, Fluid drains for lube oil and fuel,Fuel filling arrangement inside the enclosure
Note for Item No. 01 to 04 (i) Rate quoted shall include the necessary T&P , RCC foundation , structural works required to support the acessoriess of DG set such as AMF panels, controll cables, Radiators / cooling tower, Exhaust mufflers and water circualtion system / cooling System (ii) rate quoted includes the cost of All fuel ( high speed diesel) , lubes and collant required to carry out the no load and full load test of not less than 24 hrs as diercted by the accepting officer (iii) Rate quoted includes the cost of B check for the DG set such as replacement of lube oil, oil/ fuel filters /belts, O rings consumeables after the test run of the DG set during the warrenty period first 250 hrs or One year which ever is earlier after the date of commissioning
Supplying, laying, jointing testing and connecting in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 630 sqmm single core with multistranded aluminum conductors, IS 7098 marked, suitable for LT 1100 Volt system, laid in trenches fixed to pole, including jointing & testing complete all as specified and directed . Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule.
M&L for installation, testing & commissioning of waterless and maintenance free chemical earthing with 50 MM dia CU bonded MS rod of length 3.00 mtr below ground level including duly augering in ground pre cast or in situ cast in high purity electrically conductive granutar material having ultra low resistive value to achiev resistance below 02 Ohms connected with 32 x 4 MM copper strip complete all as specifed and directed by Engr-in-Charge.
Excavation in trenches not exceeding 1.5 meters wide & not exceeding 1.5 meters in depth for laying of cable and getting out in soft/loose soil including trimming the sides forming bottom surfaces to required level complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 meters wide & not exceeding 1.5 meters in depth for laying of cable and getting out in soft/disintegrated rock including trimming the sides forming bottom surfaces to required level complete all as specified and as directed.
Returning, filling in including spreading leveling, watering and well ramming in layers not exceeding 25 cms thick in each layer of soil complete all as specified.
Removing excavated material to a distance n.exc 50 meters and depositing where directed at a level not exceeding 1.5 mtrs above the starting point all as specified and directed by Engineer-in-Charge.
M/L for HDPE pipe,of size 180 mm dia suitable for 0.3 MPA working pressure with all fitting , laid in trenches for protection of cable in road /drain crossing complete all as specified and as directed.
Material and labour plain cement concrete 1:2:4 mix, type B1 using 20mm graded stone aggregate as in coping including necessary form work, exposed surface of concrete shall be finished even and smooth without using extra cement
GEPS PROJECTS
Vijay Electricals
M/S JIWAN KUMAR MITTAL
mayur enterprises
Water Power Engg. Enterprises
Leo Network power systems
MONA GENERATOR SEVICES PVT. LTD.
B D Raizada Projects Pvt Ltd
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .