Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 LAccepted-AOC 01 NAUJARPUR BASAI KAJI SASNI HATHRAS UTTAR PRADESH 202150 | ALIGARH | UTTAR PRADESH | 202150 | L1 | Accepted-AOC L1 | |
| 2 | L2₹3.5 L+₹1,350 (0.38%)Rejected-AOC BAIRGANV HATHRAS | HATHRAS | HATHRAS | UTTAR PRADESH | L2 | Rejected-AOC L2 | |
| 3 | L3₹4.2 L+₹70,000 (19.8%)Rejected-AOC GIJJROLI AGRA ROAD HATHRAS UTTAR PRADESH 204101 INDIA | HATHRAS | HATHRAS | UTTAR PRADESH | 204101 | L3 | Rejected-AOC L3 |
Tender Value
₹5 L
EMD Value
₹5,000
Closing Date
26 Oct 2020, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE EDC Hathras
SE EDC Hathras
Work
2020_DVVNL_515032_1
EDCH-70/2020-21
Open Tender
Electrical Works
Item Rate
120 days
SE EDC Hathras
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
DVVNL
₹5,000
Yes
22 Jan 2022
27 Sept 2020
26 Oct 2020
27 Sept 2020
26 Oct 2020
27 Sept 2020
30 days
Amount
Carriage of following from 132 KV Hathras store center to 33/11 KV Substations through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-50 Kms.)
8.5 Mtr. long PCC Poles
9/11 Mtr. S.T. Poles
11 KV XLPE cable
11 KV X-Arms, weasal conductor, G.I wire,Disc Insulators, Pin insulators, clamps Abc Bunch and other required line material, if any.
Dismentlling and removal of Pole from the various area, stacking and placement their coils in the respective J.Es (store) duly stacked, as per direction of supervising engineer. It includes the work of cartage, the cost of labour, T&P carrier etc. required for proper completion of work.
8.5 Mtr. long PCC Poles
9/11 Mtr. S.T. Poles
Dismentlling and removal of existing conductor from the various area, stacking and placement their coils in the respective J.Es (store) duly stacked, as per direction of supervising engineer. It includes the work of cartage, the cost of labour, T&P carrier etc. required for proper completion of work.
ACSR Weasel
Erection of following Poles including Cutting of kharanja/mettalic road/concrete portion while digging pit & complete H.T./L.T. fittings as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
PCC poles 8.5/9 Mtr.
O/D Cable Jointing Kit
Erection and grouting of stays as per RESPO manual and as per direction of supervising engineer. Grouting material i.e. cement, sand, brick ballast/stone ballast etc. shall be arranged by the contractor at his own cost.
Fixing of earthing rod as per RESPO manual and as per direction of supervising engineer.
Laying, sagging and stringing and jumpering / binding etc. of new & old ACSR Weasal conductor / GI in 11 KV / LT lines as per RESPO manual and as per direction of supervising engineer.
ACSR Weasal conductor
XLPE Cable
Cutting, chopping, triming of tree branches to clear the line route to give 2 mtr. horizontal and vertical clearance to the line coming in the route of different feeders as per direction of supervising engineer
Installation of extra ''T'' on the erected poles wherever required alongwith all fitting as per direction of supervising engineer including the cost of labour, T&P etc, required for proper completion of work. The "T" pole shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 including the cost of material.
Fixing of following accessories.
11 KV Disc Insulator with fitting.
11 KV Pin with insulator
11 KV X-Arm
F Clamp
11 KV TPMO
11 KV Fuse Set
11 KV Tpop Channel/Dropper Channel
Construction of ST Pole plinth
Providing & Fixing of Danger Board
Grouting of ST Pole (wherever required) with cement, sand and brick ballast/stone ballast in ration 1:4:8 including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. As per actual site requirement.
Construction of plinth of size 5' * 5 * 4' above ground level one ft below the ground level of 9" After Exavation of 4 "earth brick ballast shall be provided and rammering will be done properly After ballast shall be provided and rammering will be done properly After that a retaining wall 9"width by fist class brick in ratio 1:4 of cement & sand shall be made . The earth shall be filled up to one ft.below the top of the plinth After this brick ballast shall be provided upto 6"from the earth level and proper rammering shall be done one No. jall of 12 mm MS tor shall be fixed in the hollow of plinth and one ft. thick RCC in ratio of cement sand & stone ballast shall be laid on the top of the plinth. The 12 mm thick plastering shall be done all round the plinth in 1:4 ratio of cement and sand.
earthing of 250 KVA Transformers
Net Fencing Shall be 1150*1200 mm made of 35*35 mm MS Angle covered by expended netal 14 SWG up to full Height 1200 mm duly steftened by MS flat by an 8 SWG dia bolt & nut
Verious Type T/F Carrage for Exiting plinth/D/pole to proposed plinth/D/pole
25 KVA T/F
250 KVA T/F
Kaccha Road Restraction
Installation of following T/F on newly constructed double pole in proper alignment direction & making HT/LT connection.
25 KVA T/F
250 KVA T/F
Back Cartidge Poles & Other Scrap
STP Pole
Line meterisl
S.K. CONTRACTOR
SUMIT ENGINEERING
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .