Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹79.1 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹85.3 L+₹6.2 L (7.77%)Rejected-Finance DOOR NO 2 31 23 SECTOR 7 SBI COLONY MVP VISAKHAPATNAM 530 017 | VISAKHAPATANAM | ANDHRA PRADESH | 530017 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹85.3 L+₹6.2 L (7.81%)Rejected-Finance D NO 10 36 3 2 FLAT NO N 1 DASARATHA ENCLAVE RAM NAGAR VISAKHAPATNAM 530 002 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530002 | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹88.9 L+₹9.8 L (12.4%)Rejected-Finance NO 16 7 739 3RD FLOOR OSMANPURA CHADERGHAT HYDERABAD TELANGANA 500 024 | HYDERABAD | HYDERABAD | TELANGANA | 500024 | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹89.6 L+₹10.5 L (13.3%)Rejected-Finance 04 L BLOCK MARKET SECTOR 11 NOIDA 201301 UP GAUTAM BUDHA NAGAR | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | L5 | Rejected-Finance Not being lowest |
Tender Value
₹90 L
EMD Value
₹1.6 L
Closing Date
25 Nov 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE UDHAMPUR
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
REPAIR/ MAINT/ FITMENT OF RECD DEVICES FOR CAPTIVE GENERATING SYSTEM OF VARIOUS CAPTIVE IN AOR OF AGE E/M (ELECTRIC SUPPLY) UNDER GE (UTILITIES) UDHAMPUR
2024_MES_680005_1
CWE/U(U)-53/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
UDHAMPUR
AS PER NIT
6 documents required · 6 mandatory
₹1,000
GE (UTILITIES) UDHAMPUR
₹1.6 L
27 Dec 2024
17 Oct 2024
2 Dec 2024
17 Oct 2024
25 Nov 2024
8 Nov 2024
Amount
Supply Installation testing and commissioning Of retrofit emission control device for diesel generator of any make/vintage /Category and capacities as under:- Application :- Reduce particulate matter (PM 2.5), Carbon Monoxide and Hydrocarbons emitted from Diesel Engine Technology/Type :- ESP (Electrostatic Precipitator), Wet Scrubbing, Diesel Oxides Catalyst Guaranteed specified Particulate matter (PM 2.5) Carbon Monoxide, Hydrocarbon reduction efficiency (Min) 70% for all DG sets. Scope of Installation :- a) Installation of Emission Control Retrofit Device when offered by the vendor is inclusive in the scope of supply and shall be done by the seller. b) Construction of suitable earthing station and necessary connections shall be done by the seller. c) Warranty/Service :- 12 months d) Number of preventive maintenance visits offered in a year during warranty period :- 2 visits Back Pressure due to the Emission Control retrofit device :- Maximum back pressure exerted by the Emission Control retrofit device at max prescribed load by DG OEM(as per the capacity of the DG set).
Cont..... item No 1.00:- TEST REPORTS Certification :- The device must be 'Type Approved' in accordance with the Central Pollution Control Board's System and Procedure for Emission Compliance Testing of Retro-fit Emission Control Devices (RECD) for Diesel Power Generating Set Engines, dated 01/02/2022, as well as provide a type testing certificate for all KVA families of required generators. Adhering to this, RECD to be ‘Type Tested’ for an equivalent kVA family as per the System and Procedure from any one of the four Central Pollution Control Board, Govt, of India, recognized/approved test agencies/laboratories as given below: (a) Automotive Research Association of India (ARAI, Pune) (b) International Centre for Automotive Testing (ICAT, Manesar) (c) Indian Institute of Petroleum (IIP, Dehradun) (d) Vehicle Research Development Establishment (VRDE, Ahmednagar):
Cont..... item No 1.00:- General Technical Requirments (GTR)/Commissioning:- a) Emission control retrofit device shall be complete with safety precution to ensure no damage should be done to the DG set operations under anycircumstance.The Emission control retrofit device should be closely coupled with the DG exhaust to ensure 100% of the exhaust passes through theEmission control retrofit device. b) Anti vibration mountings shall be provided for complete Emission control retrofit device in case of flaxible coupling with the DG exhaust c) Emission control retrofit device should have protection against under voltage,over voltage,under frequency ,over frequency,lowbattery voltage,over current,earth fault,short circuit ,phase sequence change etc d) The Emission control retrofit device shall be with cirrosion resistive and HR paint. e) Unloading and placement of the Emission control retrofit device at the time of delivery is in the scope of work. f) The contractor shall provide the trail of the Emission control retrofit device at least two hours on site . g) All exhaust piping ,any extra work, distribution board shall be provided by the contractor in the scope of work.
(a) DG set of capacity of 500 KVA
(b) DG set of capacity of 250 KVA
(c) DG set of capacity of 200 KVA
(d) DG set of capacity of 160 KVA
(e) DG set of capacity of 125 KVA
(f) DG set of capacity of 100 KVA
M/s SS Engineering Enterprises (BID ID -3168476)
eldi techs (BID ID -3163757)
Accurate Power Systems (BID ID -3173941)
GEPS PROJECTS (BID ID -3168594)
slathia construction works (BID ID -3168247)
FANGALIA TRADERS (BID ID -3161821)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .