Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less; where V= Advertised value of the tender in crores of Rupees. N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-F, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
a) Electrical License: The tenderer/Firm should have valid electrical contractor license on their own name or firm name issued by Electrical licensing board of any state. The license should have been issued on a date prior to the date of tender opening. Copy of License shall be uploaded online failing which offer will be rejected.
Technical Eligibility Criteria: (a) The tenderer must have successfully completed or substantially completed any of the following during last 07 (seven) years, ending last day of month before the one in which tender is invited: Three similar works costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works costing not less than the amount equal to 40% of advertised value of the tender, or One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Definition of Similar nature of work: "Works of wiring/cabling or installation and commissioning of electrical items (other than on coaches) such as lights, fans, pumps, charging arrangements, earthing etc. (with or without supply of items / equipment) for 230V, 1phase or 415V, 3phase system or higher voltages".
9 conditions · 1 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderer /s are required to submit a scanned / attested copy of following information along with their tender- 1. Bank Account No 2. Name of Bank 3. Indian Financial System Code {IFSC} 4.PAN No 5. Tenderers Contact No Contractor should provide firms PAN, issued by Income Tax Department with his quote or within30 {Thirty} days of award of contract. No payment will be released without submission of PAN. All taxes including surcharge and cess shall be recovered from his payment as per tax provisions in vogue.
The tenderer shall thoroughly go through the entire tender document and strictly adhere the instructions and directions given at different pages.
It is responsibility of the tenderer that they ensure to see any corrigendum of the tender to check the corrigendum on the website from time to time.
All the required/supporting documents should be scanned and uploaded.
In case the date of closing mentioned in the Notice Inviting Tender is declared a holiday/bandh/strike etc. on any account, the date of closing tender online will not be changed as the application in the website of IREPS does not permit submission of any offer after closing date and time of the tender. However, opening of tenders online will be on any convenient day after the closing date/time of tenders.
Opening of e-tender online:- The e-tenders will be opened online using the IREPS portal. No representative is required to be present for opening of tender and taking notes of rates quoted and ranking as the complete details of rates etc. of all the bidders shall be available to the bidders in the website after the opening of the tender.
Provision of Facade lighting arrangements at all 15 Amrit stations over Nanded division.
NED-E-41-2025-26~SCR
NED-E-41-2025-26
Open
Works - General
12 Months
Nanded, Maharashtra
₹0
₹3.8 L
3 Feb 2026
9 Jan 2026
19 Jan 2026
59 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 4,54,07,434 | ||
| — | 230.00 | — | — | ||
| Supply, Erection, Testing and Commissioning of LED round projector type/flood/pillar/Wall washer facade light, 48 W, RGBW, DC 24 V with IP 65 Protection, Cast Aluminium Double powdered paint, 4 mm safety glass IP 68 Connectors, Luminaire efficacy required minimum guaranteed 50 lumen/watt, CRI > 80, Projecting Distance 30 Mtr, Control mode in DMX switchable dimmable / tunable, static Lighting. 9.5" Round Projector. The product should be BIS approved To be supported with Product test reports and LEDs Test Reports. Luminaire shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. This includes crane charges if any for height work.(Warranty Period of 5years). All test reports and technical data sheets to be submitted to the competent authority for approval.After installation, assembling and commissioning contractor should ensure that all parts of the light are properly fixed and put it into running condition. The entire work should be carried out as per the instructions of Site Engineer. Testing of the fixtures to be done in the presence of Site Engineer for a minimum period of 1 week. | — | — | — | 49,98,590 | |
| — | 105.00 | — | — | ||
| Supply, Installation, Testing, and Commissioning of exterior BIS registered 75W LED RGBW flood/pillar/Wall washer facade lighting luminaire for facade lighting with Die-cast aluminum housing,powder-coated finish, minimum system lumen efficacy equal to or greater than 50lm/w. The luminaire shall be capable of producing dynamic color-changing light with 16 million colors as the light fixture should be programmable using 8-bit control DMX 512 protocol / Ethernet-based control. The luminaire should be complete with a dedicated Lens madeup of UL/VDE approved PC for each LED, offering beam angles of different types such as narrow, medium, wide,or elliptical as per the site requirement. Fixture with constant locking hinges for simple position control from various angles without special tools. The fixture shall be suitable to operate at an ambient temperature range of - 30°C to 50°Cand the complete luminaire shall be IP 66 and IK07 rated. LED Life time shall be at least L70B50 @ 50,000 burning hours at 50°C. LED should beof NICHIA/OSRAM/SEOUL/PHILIPS LUMILEDS/CREE/LEDNIUM/AVAGOmake. DMX enabler circuit should beinside the Luminaire only. Luminaireshall be complete with integrated BISIP 66/67 potted driver and capable ofoperating at line voltage from 90-305Vac, 50Hz with power factor > 0.9.The product should be BIS-approvedwith the R number mentioned on theproduct label. To be supported withProduct test reports - LM79, BISReport, and LEDs Test Reports.Luminaire shall conform to BIS i.e. IS10322 (Part 5/Sec 5) and shall becomplete with all necessaryaccessories required for the proper working of the fixture including weather proof connection cables,waterproof connectors, etc. as required. This includes crane charges if any for height work.(WarrantyPeriod of 5 years). All test reports and technical data sheets are to be submitted to the competent authority for approval. After installation,assembling, and commissioning contractor should ensure that all partsof the light are properly fixed and putit into running condition. The entire work should be carried out as per the instructions of Site Engineer. Testing of the fixtures to be done in the presence of Site Engineer for a minimum period of 1 week. | — | — | — | 38,28,195 | |
| — | 1200.00 | — | — | ||
| Supply, installation, testing, and commissioning of exterior BIS registered 36 W 24V DC RGBW Linear LED Wall Washer luminaire for facade lighting with extruded aluminum housing, powder-coated finish, and Clear toughened glass. With all LEDs ON, minimum system lumen efficacy equal to or greater than 62.9 lm/w.The luminaire shall be capable of producing dynamic color- changing light with 16 million colors as the light fixture should be programmable using 8-bit control DMX 512 protocol /Ethernet-based control. The luminaire should be complete with a dedicated Lens made up of UL/VDE approved PCfor each LED, offering beam angle ofdifferent types such as narrow,medium, wide, or elliptical as per thesite requirement. The fixture shouldbe erected with the necessary required brackets and should have constant locking hinges for simple position control from various angle swithout special tools. The fixture shall be suitable to operate at an ambient temperature range of -30°C to 50°C and the complete luminaire shall be IP66 and IK 07 rated. LED Life time shall be at least L70@ 25C @ 50000 burning hours at 25°C. LED should be of NICHIA/OSRAM/SEOUL/PHILIPS/LUMILEDS/CREE/LEDNIUM/AVAGO make. The product should be BIS approved with R number mentioned on product label. To be supported with Product test reports - LM79, BIS Report and LEDs Test Reports.Luminaire shall be conforming to BISi.e. IS 10322 (Part 5/Sec 5) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. This includes crane charges if any for height work.(Warranty Period of 5 years). All test reports and technical data sheets to be submitted to the competent authority for approval.After installation, assembling and commissioning contractor should ensure that all parts of the light are properly fixed and put it into running condition. The entire work should be carried out as per the instructions of Site Engineer. Testing of the fixtures to be done in the presence of Site Engineer for a minimum period of 1 week. | — | — | — | 1,74,14,400 | |
| — | 315.00 | — | — | ||
| Supply, installation, testing & commissioning of 200 watt DC 24V Constant Voltage driver to operate lighting systems having multiple LED modules connected in parallel, hence to make architectural lighting systems with a very slim form factor and seamlessly integrated into various structures. The driver should be commissioned with all necessary electrical connections and have following features: DC24V Constant Voltage Switch Mode Power Supply,Water proof IP65 or above ingress protection, efficiency more than 85%.Operating temperature: -30 to +65degree centigrade, THD less than 20% with necessary connections, Warranty: 5 Years, Electrical Safety Class:Class 1. (The work to be executed as per direction of engineer in charge atsite. If any other items have beenomitted but required for efficient working for facade lighting it would be responsibility of contractor to supply and provide such items. However the quoted rate shall be inclusive of those items). | — | — | — | 5,60,070 | |
| — | 4280.00 | — | — | ||
| Supply Erection testing and commissioning of DMX signal cable /shielded Cat. 6 or better data cable shall be used for digital communication networks. Size and quantity of cable shall be as per site requirement and as directed by SSE Incharge. Copper lugs, glands of proper size shall be used for connections. | — | — | — | 10,48,600 | |
| — | 1535.00 | — | — | ||
| Supply Erection testing commissioning of male-Female sets for connecting DMX cable of RGB fitting with 5-pin DMX XLR connectors for lighting cables and Effects,Set includes one male connector and one female connector, Gold pins for optimum signal transfer,Stranded Tinned Copper Conductors,PVC Jacket, Length- 6 inches. | — | — | — | 11,03,665 | |
| — | 36.00 | — | — | ||
| Supply, Installation, Testing and Commissioning of DMX Splitter with Input Voltage range : 100-240 V 50-60Hz AC, Power Consumption 4W/8W max. Housing is made of polycarbonate with powder coated finish Mounting, 19 inch rack mountable, Operation Temperature-17°C to +55°C, 5 Output with 5 pin XLR terminal sockets, Ingress Protection Rating IP20. This unit takes the DMX Signal from DMX Controller & split the signal into 5 DMX output per universe/10 DMX output for double rack versions. The output terminals of Splitters are optically isolated from the input. Splitters should be capable to amplify the DMX signal & allowing the data link to be extended by max. 300m (1044 ft.) using AWG 22 DMX cableor 150 m (500 ft.) using AWG 24 DMX cable or maximum 20-25 fixture per output channel. To be provided with IP enclosure if installed in external environment. All test reports and technical data sheets to be submitted to the competent authority for approval. After installation,assembling and commissioning contractor should ensure that all parts of the DMX splitter are properly fixed and put it into running condition. The entire work should be carried out as per the instructions of Site Engineer.Testing of the DMX splitter to be done in the presence of Site Engineer for aminimum period of 1 week. The make of the cable used shall be approved by Railways. | — | — | — | 24,46,128 | |
| — | 18.00 | — | — | ||
| Supply, Installation, Testing and Commissioning, of DMX Controller for the system including all other accessories required for the running of the system Controller should have Input Power 5-12 V DC and Output Protocol DMX 512 with 4 universe, 2 universe should work in Stand Alone Mode and 2 universe should work inlive mode with laptop/ tablet /computer. The universe should be expandable from 2 to 4 DMX 512 universes. It should be compatible for Programmability with PC, Mac, Tablet,Smart phone by using USB & Ethernet.DMX controller should have network controllability feature to control the scene remotely through LAN and triggered via UDP packets on port 2430. It must have sufficient DMX512RJ45 ports and sufficient RS-232 -pinserial ports. It must have ConnectionsType C USB, XLR3, Ethernet, battery.There should be provision for Memory microSD card. Device should haveIntuitive backlit keyboard with 10presets and also have provision ofkeypad on device for changing scenemanually from device. Device shouldbe capable to work on Extendedtriggering possibilities (TCA) & alsohave Smart Upgrade Technology(SUT). It is an IP 20 unit and has anOperating Temperature of 0°C to50°C. OS Requirements for thecontroller is Mac OS X 10.8-10.12,Windows 7/8/10/11. Standards shouldbe EC, EMC, ROHS. The controllershould have a variety of featuresincluding 2048 DMX channels,clock/calendar, iPhone/iPad/Androidremote control, Ethernet facilities, drycontact port triggering and multi-zoneSD card memory. Networksynchronization of one area acrosshundreds of universes with thepossibility of 99 scenes across 5 areaswith auto clock triggering for sunriseand sunset and as per the festivals forspecific occasions. Device should beequipped with meta; clamp to mounton wall. Facade lighting product andits driver should be compatible withDMX controller. To be provided with IP66 polycarbonate enclosure.(Warranty Period of 5 years). All testreports and technical data sheets tobe submitted to the competentauthority for approval. Afterinstallation, assembling andcommissioning contractor shouldensure that all parts of the DMXcontroller are properly fixed and put itinto running condition. The entirework should be carried out as per theinstructions of Site Engineer. Testingof the DMX controller to be done inthe presence of Site Engineer for aminimum period of 1 week | — | — | — | 29,69,208 | |
| — | 5100.00 | — | — | ||
| Supply and laying of 4C X 2.5 sq mm XLPE insulated armoured copper cable suitable for Rated Voltage of 1100V grade and conforming to IS 7098 partI with amendment number 1 2 and 3 reaffirmed 2005 or latest and IS 8130 with latest amendments and with ISI marking. Cable shall be supplied by the OEM or their authorized dealerduly producing dealership certificate Cable shall be tested by CPRI ERDANABL or any other laboratories recognized by the Govt. of India test certificate and OEM warranty certificate shall be produced by the supplier along with the supply of the cable. | — | — | — | 7,24,200 | |
| — | 840.00 | — | — | ||
| Supply and termination of Polyamide cable glands & copper lugs suitable for terminating 4C x 2.5 sq mm XLPE Insulated armoured copper cable.Cable Glands - Cable shall be terminated using double compression type cable glands. Testing requirements of Cable glands shall conform to BS:6121 and gland shall be of robust construction capable ofclamping cable and cable armour (forarmoured cables) firmly without injury to insulation. Cable glands shall be made of heavy duty brass machine finished and nickel chrome plated.Thickness of plating shall not be lessthan 10 micron. All washers and hardware shall also be made of brass with nickel chrome plating Rubber components shall be of neoprene or better synthetic material and of testedquality. Cable glands shall be suitablefor the sizes of cable supplied/erected.Cables to be terminated - UnarmoredHT power cables, Armoured and Unarmored LT power cables,unarmored Control cables and unarmored Screened(instrumentation) cables 2. Cable Lugs- Cable lugs for power cables shall betinned copper solderless crimping type suitable for copper compacted conductor cables. Cable lugs and ferrules for control cables shall be tinned copper type. All power cable lugs shall be Single hole type. The cable lugs for control cables and screened/instrumentation cables shall be pin type and shall be provided with insulating sleeve. Cable lugs and ferrule shall conform to DIN standards. | — | — | — | 92,400 | |
| — | 520.00 | — | — | ||
| Supply and Installation of Junction Boxes, Pipes & flexible conduit of FRPJB (IP 65) Size: 139x 119x 70 mm with stud type terminal suitable for terminating 4c x 2.5 sq.mm XLPE armoured cable,The junction box be 2.7 mm thick with electrically insulated body shock proof, connector leads and control equipped with 1nos.16 amps rewireable fuse and its neccessary cutout. The box should be of front door opening with rubber gasket to make it water tight. The junction box shall be vermin proof having rubber bushes at cable entry.The junction box shall be mounted on pole/ wall etc at the height of 1.50 mtrs or as per site condition by providing MS clamps of suitable size.Color of junction box shall be got approved before erection. The junction box shall be erected in an approved manner as per the site condition and instructions of field Engineer. | — | — | — | 4,38,880 | |
| — | 320.00 | — | — | ||
| Supply and Installation of Junction Boxes, Pipes & flexible conduit of FRPJB (IP 65) Size: 260 x 210 x 116 mm with stud type terminal suitable for terminating 4c x 2.5 sq.mm armoured cable & housing 1 driver,The junction box should be 2.7 mm thick with electrically insulated body shock proof,connector leads and control equipped with 1 nos.16 amps rewireable fuse and its neccessary cutout. The box should be of front door opening with rubber gasket to make it water tight.The junction box shall be vermin proof having rubber bushes at cable entry.The junction box shall be mounted on pole/ wall etc at the height of 1.50 mtrs or as per site condition by providing MS clamps of suitable size.Color of junction box shall be got approved before erection. The junction box shall be erected in an approved manner as per the site condition and instructions of field Engineer. | — | — | — | 3,33,120 | |
| — | 800.00 | — | — | ||
| Supply of MS work of miscellaneous size and for cable tray etc including painting complete. | — | — | — | 52,800 | |
| — | 800.00 | — | — | ||
| Fabrication fixing and erection of MS work of miscellaneous size,riveted,bolted or welded in built up sections including cutting, grinding and straightening, drilling, riveting,handling, hoisting and fixing inposition etc. including applying apriming coat of approved steel prime retc. and duly painted with fine finish with contractors steel and materials.The work shall be done as per the site requirement in an approved manner and as per the instructions of field supervisor. | — | — | — | 7,200 | |
| — | 5000.00 | — | — | ||
| Supply and concealing of rigid PVC conduits of 25 mm Dia (IVORY colour)confirming to IS 9537/P3/1983 orlatest (ISI marked) with wall thickness not less than 2.0mm along with the all accessories and including cutting the wall/ceiling/chipping or elsewhere and making good the same as directed by Engineer in charge at site. | — | — | — | 2,35,000 | |
| — | 44.00 | — | — | ||
| Supply and fixing of 32 A 4P MCB B Curve IS/IEC 60898-1 (2002) 10 kA breaking capacity IP 20 protected terminals of model no.402463 of Legrand make or it's equivalent. | — | — | — | 93,060 | |
| — | 22.00 | — | — | ||
| Supply and fixing of 40 A Electro mechanical 4P RCBO 30 mA sensitivity as per in accordance with IS12640-2 & IEC 61009-1, of Model No.DHBMACTN8030040 of Havell's Make or its equivalent with necessary connections and all accessories complete. | — | — | — | 1,05,006 | |
| — | 900.00 | — | — | ||
| Supply and Laying of 4 core 10 sq mm copper cables XLPE insulated, cores laid up, PVC inner sheathed unarmoured 650/1100V grade as per IS 7098(Part 1) 1988. | — | — | — | 4,19,400 | |
| — | 2240.00 | — | — | ||
| Supply and Installation of Glow Signage Boards Platform information/Vertical amenities/ Tracking facing station name boards | — | — | — | 68,32,000 | |
| — | 900.00 | — | — | ||
| Supplying & erecting mains with 2x6 sq.mm. and earth wire 4 sq.mm FRLSH PVC copper wire, in HMS PVC conduit min.20 mm dia, as per specification. Make: Havells/Finolex/Polycab/Finecab. | — | — | — | 2,19,600 | |
| — | 22.00 | — | — | ||
| Supplying and erecting triple pole and neutral distribution board (TPNDB) with door surface/flush mounted with 4 ways for incoming and 12 ways for outgoing SP/TP MCB's on iron frame/laminated board as per specification No. SW-SWR/MCBDB Make: Legrand/Havells/L&T. | — | — | — | 55,264 | |
| — | 22.00 | — | — | ||
| Supply, erection and marking DP MCB 16-32A, 10 kA B/C-series in provided distribution board as per specification No. SW-SWR/MCB Make: Legrand /Havells/L&T. | — | — | — | 11,264 | |
| — | 22.00 | — | — | ||
| Supply, erection and marking SP MCB 16-32A, 10 kA B-series in provided distribution board as per specification No. SW-SWR/MCB Make: Legrand /Havells/L&T | — | — | — | 4,224 | |
| — | 3000.00 | — | — | ||
| Supply and laying of ISI marked 4 core 16 sq mm cross linked polyethylene (XLPE) insulated LT UG cable, PVC outer sheathed, armoured with galvanized round steel wire or steel strip and with aluminium conductor suitable for rated voltage at 1100 volts grade and conforming to IS:7098(Part-1)/1988 witham dt. no.1,2 & 3 (reaffirmed 2005) or latest. Make:Polycab/Finecab/Finolex/Havells | — | — | — | 4,14,000 | |
| — | 700.00 | — | — | ||
| Supply and running of 8 SWG GI wire is to be laid for earth continuity. | — | — | — | 8,400 | |
| — | 70.00 | — | — | ||
| Supply and erection of earth electrode as per the enclosed specification (including digging earth pit, electrode earth box with reinforced concrete complete with all connected materials and works including connecting the earth electrode and aerial earthing according to IS 3043 and RDSO drawing ETI/OHE/P/7021 in other than substations. | — | — | — | 2,65,860 | |
| — | 450.00 | — | — | ||
| Supply of 100 mm dia 'B' class ERW GI pipe conforming to IS: 1239 Part 1(2004)and fixing with suitable clamps on wall/building including laying of cable through GI pipe. | — | — | — | 4,83,300 | |
| — | 700.00 | — | — | ||
| Cutting of esphated road/ concrete/ cement/under the track etc., and excavation of cable trench 30 cm wide x 90cm deep road etc., for laying of HT/LT UG cable. After laying of cable the trench should be brought to its original position by providing tar/ concrete/ cement as per the site conditions and as per directions of Rly.Engineer. | — | — | — | 1,51,200 | |
| — | 700.00 | — | — | ||
| "Supply, erecting and laying of HDPE pipe of PE-80 grade in PN-4 outer dia of HDPE pipe 63 mm (nearest 2"" dia) and wall thickness minimum 2.5 mm maximum 2.8 mm with ""T' joints, bends, elbows etc.including all other connected accessories.Make: M/s.Sudhakar/ Nagarjunapolymer/Nandi/Plasto. | — | — | — | 92,400 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .