Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.3 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹29.4 L+₹40,975 (1.41%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹32.3 L+₹3.3 L (11.3%)Rejected-Finance 397 JASPREET SALUJA INDORE VISHNUPURI ANNEX INDORE MADHYA PRADESH 452001 | INDORE | MADHYA PRADESH | 452001 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹35.1 L+₹6.1 L (21.2%)Rejected-Finance AVAS VIKAS NANDANPURA JHANSI UP 284003 | JHANSI | UTTAR PRADESH | 284003 | L4 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | M/S Shankardass Devidass L1 | M/S J S ENGINEERS L2 | M/S ANMOL TRADING CO L3 | M/S Hema construction L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully unserviceable aluminium point wiring (light, fan, socket bell or power) complete, (fittings such as switches, ceiling rose lamp holder, regulators, sockets, pendants) stacking at site and keeping in safe custody for taking credit, complete all as specified and directed. | 1,700 | Per point | 10 ₹17,000 | 5 ₹8,500 Lowest | 38 ₹64,600 | 30 ₹51,000 |
| 2.00 | Taking down ceiling fan any sweep, removing blades ,cleaning the fan completely for dust and dirt and hanging the same back to its original positions including connecting with three core flexible copper wire to ceiling rose etc after the completion of the point wiring including replacement of old unserviceable fan hook, rubber pad, nut bolts and washers etc, complete all as specified and directed. | 120 | Each | 20 ₹2,400 Lowest | 50 ₹6,000 | 90 ₹10,800 | 90 ₹10,800 |
| 3.00 | Taking down existing electric water heater, keeping aside safely & refixing the same to its original position after servicing of the whole geyser/making functional and after completion of wiring work, complete all as specified and directed.
Note: If any part found unserviceable during the refixing of water heater at site shall be provided by the contractor and cost for the same shall be deemed to be included in the quoted rates. | 40 | Each | 50 ₹2,000 Lowest | 230 ₹9,200 | 70 ₹2,800 | 280 ₹11,200 |
| 4.00 | M&L for point wiring with PVC insulated sheathed 1100 volt grade FRLS cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and in existing PVC conduit of any size , fixing acessories inculding sunken anodised pressed terminal box not less than 1.2 mm thick covered with 3 mm thick bakelite laminated sheet cover of suitable size with suitable size screws for mounting switches, sockets, regulators with and including 1.5 sqmm FRLS multi stranded copper conductor drawing as continuous earth wire connected to main earth and earth dolly for One light point controlled by one switch 5 Amp complete all as specified and directed. | 100 | Point | 350 ₹35,000 | 400 ₹40,000 | 380 ₹38,000 | 170 ₹17,000 Lowest |
| 4.01 | All as per Srl item N0 04 above but for One ceiling fan/exhaust fan point controlled by one switch 5Amp complete all as specified and directed. | 10 | Point | 350 ₹3,500 | 400 ₹4,000 | 300 ₹3,000 | 150 ₹1,500 Lowest |
| 4.02 | All as per Srl item N0 04 above but for One socket out let 5Amp controlled by one switch on same board complete all as specified and directed. | 20 | Point | 350 ₹7,000 | 250 ₹5,000 | 150 ₹3,000 Lowest | 150 ₹3,000 Lowest |
| 4.03 | All as per Srl item N0 04 above but for One socket out let 5 Amp controlled by one switch on independent board complete all as specified and directed. | 30 | Point | 350 ₹10,500 | 400 ₹12,000 | 150 ₹4,500 Lowest | 150 ₹4,500 Lowest |
| 4.04 | All as per Srl item N0 04 above but for One bell point 5 Amp controlled by one bell push on independent board. complete all as specified and directed. | 5 | Point | 350 ₹1,750 | 400 ₹2,000 | 350 ₹1,750 | 150 ₹750 Lowest |
| 4.05 | All as per item No 4 here in before but point wiring with 2.5sqmm FRLS multi stranded copper conductor cable for main circuit and 2.5sqmm cable as earth continuity conductor for one 15 Amp socket out let controlled by one 15Amp switch on independent board complete all as specified and directed. | 25 | Point | 500 ₹12,500 | 580 ₹14,500 | 480 ₹12,000 | 190 ₹4,750 Lowest |
| 5.00 | M&L for point wiring with PVC insulated sheathed 1100 volt grade FRLS cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium grade ISI marked not less than 20 mm dia ,concealed in wall and surface on ceiling with all conduit fittings & fixing acessories inculding sunken anodised pressed terminal box not less than 1.2 mm thick covered with 3 mm thick bakelite laminated sheet cover of suitable size with suitable size screws for mounting switches, sockets, regulators with and including 1.5 sqmm FRLS multi stranded copper conductor drawing as continuous earth wire connected to main earth and earth dolly for One light point controlled by one switch 5 Amp complete all as specified and directed. | 380 | Point | 300 ₹1,14,000 | 425 ₹1,61,500 | 310 ₹1,17,800 | 210 ₹79,800 Lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
25 Jun 2026, 6:00 pmClosed
GE NAGROTA
GE NAGROTA
REPAIR/REPLACEMENT OF INTERNAL WIRING INCLUDING FITTING AND FIXTURES AT OTM ACCN UNDER AGE E/M OF GE NAGROTA
2026_MES_766143_1
CANO GEN/TOKEN-22/2026-2027
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE NAGROTA
Class D Cat b (i)
9 documents required · 9 mandatory
₹500
GE NAGROTA
₹80,000
Yes
22 Aug 2026
5 Jun 2026
30 Jun 2026
5 Jun 2026
25 Jun 2026
19 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down carefully unserviceable aluminium point wiring (light, fan, socket bell or power) complete, (fittings such as switches, ceiling rose lamp holder, regulators, sockets, pendants) stacking at site and keeping in safe custody for taking credit, complete all as specified and directed. | 1,700 | Per point | - | - |
| 2 | Taking down ceiling fan any sweep, removing blades ,cleaning the fan completely for dust and dirt and hanging the same back to its original positions including connecting with three core flexible copper wire to ceiling rose etc after the completion of the point wiring including replacement of old unserviceable fan hook, rubber pad, nut bolts and washers etc, complete all as specified and directed. | 120 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
BOQ_862248.xls
BOQ • 1.10 MB
tender22.pdf
Tender Documents • 1.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .