Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.2 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹25.2 L+₹3.0 L (13.4%)Rejected-Finance | L2 | Rejected-Finance Quoted amount is more than L1 | |
| 3 | L3₹27.4 L+₹5.2 L (23.2%)Rejected-Finance | L3 | Rejected-Finance Quoted amount is more than L1 | |
| 4 | L4₹31.1 L+₹8.9 L (39.9%)Rejected-Finance MAGADH COLONY ROAD NO 6 PS MAGADH MEDICAL COLLEGE PO CHANDAUTI MORE DISTT GAYA BIHAR PIN 823001 | GAYA | BIHAR | 823001 | L4 | Rejected-Finance Quoted amount is more than L1 | |
| 5 | L5₹34.8 L+₹12.6 L (56.5%)Rejected-Finance | L5 | Rejected-Finance Quoted amount is more than L1 |
Tender Value
₹27.7 L
EMD Value
₹55,500
Closing Date
16 Feb 2022, 6:00 pmClosed
Major S Rakesh
Garrison Engineer Ranchi, 7th Club Road Ranchi, PIN-834001
SPL REPAIR WORK TO BLDG NO P-39/1 TO 8 (OR MD ACCN), PROVN OF 20X DESERT COOLET AT OTM ACCN OF 100 FD REGT AND 02 AIR CONDITIONERS FOR NFS NODE AT ARMY CAMP JAMSHEDPUR UNDER GE RANCHI
2022_MES_503025_1
8200/1382/E8
Open Tender
Civil Works
Item Rate
180 days
Ranchi
Class D Cat a(i)
6 documents required · 6 mandatory
₹500
GE Ranchi
₹55,500
Yes
17 Mar 2022
21 Jan 2022
18 Feb 2022
22 Jan 2022
16 Feb 2022
4 Feb 2022
Amount
Demolition of plain cement concrete in ground floor and paving not exceeding 15cm thickness below or above ground level including removal of same to exceeding 1 Km but not exceeding 1.5 Km complete all as specified and directed.
M&L for PCC (1:5:10) type E-2 using 40mm graded brick aggregate as in sunken portion, complete all as specified and directed.
M&L PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in sunken floor .average thickness 40mm and making adequate slop towards spout pipe etc, complete all as specified and directed.
M&L for bitumen blown 85/25 applied hot two coats to concrete surfaces at rate of 1.2 Kg/Sqm per coat, complete all as specified and directed. Make : STP
Demolition of plain cement concrete Concrete of any description and in any position not otherwise specifically provided for including removal of same to exceeding 1 Km but not exceeding 1.5 Km, complete all as specified and directed.
M&L PCC (1:4:8) Cement concrete type D-2 using 40mm graded stone aggregate in foundations,filling and mass concrete, complete all as specified and directed.
M&L for cement concrete type B- 2,1:2:4 ,75mm thick (40mm graded aggregate) as in floors, complete all as specified and directed.
M&L for polythene film black 200 micron laid in floors/Walls etc, complete all as specified and directed.
Taking down cement plaster on brick wall or concrete surface etc including raking out joints hacking for key scrubbing down with water etc, complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of bricks/concrete surface in cement mortar (1:6) on wall finishing the surfaces even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of bricks/concrete surface in cement mortar (1:4) with using on wall finishing the surfaces even and smooth without using extra cement, complete all as specified and directed.
M&L for 10 mm thick cement plaster in cement mortar 1:3 for ceiling, finished even & smooth without using extra cement, complete all as specified and directed.
M&L for repair and rendering 10mm thick in CM 1:3 on chajjas not exceeding 60cm width after removing cracked plaster and concrete including cleaning of viisible reinforcement and treating with cement slurry also necessary repair to cracked concrete if any with cement concrete 1:2:4 Type B-0 using 12.5mm graded aggregate including necessary scafolding work for double/single storey bldgs, complete all as specified and directed.
Dismantling steel window and ventilators including guard bar etc complete and removing to MES store all as directed at site, complete all as specified and directed.
S&F aluminium anodised aluminium window shutter Sliding type with frame of anodised aluminium channel section suitable for sliding aluminium shutters weighing not less than 0.55Kg/M including necessary joining cleats glazing clips rubber packing anodised aluminium shop beading screws with two shutter Including 3.5mm thick coloured glass and one shutter with stainless steel wire gauze including necessary locking arrangement and handle etc; as specified etc, complete all as specified and directed.
S&F anodised aluminium ventilator shutters fixed or louvered type without sash bar, aluminium section weighting not less than 0.55 Kg/M including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws and 4 mm thick figured glass fixed in fram etc, complete all as specified and directed.
S&F frame work such as grills, grating etc with ends of bars shouldered and or rivetted or forged into spikes, framed guard bars, barred iron doors, ladders etc and similar wks conforming to Fe-290 Gd E-165 .
Taking down chowkhats or frame n.exc 1.50 Sqm each with shutter (without taking of shutter from framed) complete incl removing from site, complete all as specified and directed.
Taking down chowkhats or frame exc 1.50 Sqm but n.exc 4 Sqm each with shutter (without taking of shutter from framed) complete incl removing from site.
Taking down shutters of any description exc 1 sqm and n. exc 2 sq m each and removing from site.
Solid PVC Double door frame of size 50mm x 95mm made out of 5mm wood grain printed sheet PVC sheet reinforced with M.S.tube, suppling & fixing in opening as per specification & drawing.
S&F factory made solid PVC Moulded door shutter 28 to 30 mm thick(stiles) with 2 mm thick prelaminated Moulded PVC sheet polyurethane painted on the front face & 2 mm plain colour PVC sheet on back faces,and with particle board core supplying and fixing in frame at site as per specification and drawing.
M&L for 1st class hard wood plain,solid straight chowkhats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints supplied and fixed.
M&L for 30 mm thick flush shutters solid core construction,with block board core and plywood face panels,commercial type on both sides, complete all as specified as directed.
S&F 30mm thick 1st class HW Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats.
S&F solid PVC door frame of size 50mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS Square tube S&F in opening all as shown on drawing and specified.
S&F factory made solid panel PVC door shutter 30 mm thick style consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheets strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail lock rail and bottom rail on either side and as gap inside for top rail and bottom rail paneling of plain colour PVC sheet to be fitted in the MS frame welded/seated to the stiles and rail with suitable PVC sheet bending and jointed to gather with solvent cement supplying and fixing in the frame at site as per specification and drawing.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or stainless steel wire staples, complete all as specified and directed.
S&F Hasp and staple safety type aluminium anodized hinges pin incl bolt to hinges plate 125 mm long.
S&F butt hinges 100mm long medium weight cold rolled MS and fixed complete all as directed at site, complete all as specified and directed.
S&F extruded aluminium alloy butt hinges 100mm size type B-21 all as specified & directed.
S&F 150 mm long aluminum anodized barrel tower bolt extruded section.
S&F aluminum handles cast type anodize 150 mm long.
S&F 300 mm long of bolt Mild steel sliding door bolts,plate type,stove enamelled black,with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts,four on bolt plate and two on staple plate, complete all as specified and directed.
S&F for 300mm ordinary rat tail rod pattern springs including roller and roller plate of brass, complete all as specified and direcetd.
S&F mild steel works as in small articles like hold fasts, conforming to Fe-290 or Fe E-165, complete all as specified and directed.
Cutting holes in brick walls in cement mortar for inserting holdfasts and making dismantaled portion in CM (1:3) or cement concrete 1:2:4 Type B-1,Depth of embedded portion of Holdfasts not exc.half brick, complete all as specified and directed.
Taking up or down steel tubing and connection of 15 mm bore complete all as specified directed at site.
All as per item No 38 above but for 20 mm dia bore pipe.
S&F steel tubing and connection tubing in new or old position to walls, ceiling, floors etc including all fitting as socket,elbow,nipple,union etc, complete all as directed at site for 15 mm bore all as specified.
All as per time No 40 above but for 20 mm dia.
Dismantling of boarding any description, fixed in any position with screws all as specified.
S&F prelaminated particle board 18-19 mm thick interior grade prelaminated one side with decorative choice lamination and other side balancing white lamination to timber frame work in cupboard, complete all as specified and directed.
M&L for 2nd class hardwood of sectional area exc.15 & n.exc 25 sqcm in plain fillets,square rectangular in section, clean sawn, secured with nails, complete all as specified and directed.
S&F 30mm width of flaps continues piano hinges mild steel bright finish or electro galvanised, complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern) including all fittings, heads, shoes, bends, swan-necks, etc including removing from site.
M&L for 110mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints fixed on walls/floors including PVC clamps fixed to wall properly including fixing of pipe with PCC (1:2:4), complete all as specified & directed.
M&L for 75mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints fixed on walls/floors including PVC clamps fixed to wall properly including fixing of pipe with PCC (1:2:4), complete all as specified & directed.
M&L for 40mm dia of low density polyethylene (LDPE)of pressure rating 6 kgf/sqcm fixed to walls,ceilings or in floors etc, complete all as specified and directed.
S&F PVC (SWR) bends 110 mm bore of any radius, complete all as specified and directed.
S&F PVC (SWR) bends 75 mm bore of any radius, complete all as specified and directed.
S&F PVC (SWR) junction single (singleT) equal or unequal 110mm bore provided with access door, complete all as specified and directed.
S&F 110 mm bore PVC (SWR) vent cowl.
S&F 75 mm dia outlet PVC (SWR) floor trap plain with steel grating including jointing with solvent cement.
S&F 110mm dia PVC (SWR)WC connector with lip ring.
Excavation in trenches not exc 1.5 mtr wide and not exc. 1.5 mtr deep for foundation in soft/loose soil & getting out.
Demolition and breaking up drain pipe 150 mm internal dia of pipe (salt glazed ware, AC or reinforced concrete) sat in cement mortor.
Returning filling in trenches including spreading leveling and well ramming with water complete n.exc 25 cm thick in each layer in soft/loose soil.
Removing exavated soild n.exc 50 mtr and depositing where directed at a leve n. exc 1.5 mtr above the starting point.
M&L for 150 mm dia of reinforced concrete pipe, class NP2, laid and jointed complete with collars, complete all as specified and directed.
M&L PCC 1:3:6 type C-2 using 40 mm graded stone agg for concrete bed to drain pipes including , packing under and haunding against the sides of pipe, after they tested for 150 mm dia pipe, complete all as specified and directed.
Demolition of brick work built in cement mortar.
M&L brick work using sub class B bricks straight of curved on plan exc 6m mean radius built in CM (1:4), complete all as specified and directed.
M&L brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick wall built in CM (1:4), complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in coping, bed plate, etc complete all as specified and directed.
M&L precast cement concrete type B-1 (1:2:4) using 20mm graded aggregate as in cover slab, shelves, and similar work set in CM (1:4), complete all as specified and directed.
M&L cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in lean concrete for foundation in drain, manholes etc, complete all as specified and directed.
M&L mild steel TMT bars 8 to 10mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
M&L rendering 10mm thick on fair faces of brick or concrete surfaces and finishing the surfaces fair and even without using extra cement in CM (1:4) with W.P.C (W.P.C will be measured and paid separately), complete all as specified and directed.
Supply only integral water proofing compound. Make - ACCO PROOF/WATER SEAL/ IMPERMO)
M&L for roof treatment in repair by complete removel of existing old treatment and treated with following specifications :- (a) Brushing neat cement slurry @ 3Kg per Sqm on roof slab. (b) 15 mm thick cement plaster fair finished using cement mortar (1:4) with WPC on roof slab. (c) Applying oil based bitumen primer @ 0.30 ltr/Sqm on plastered surface. (d) Applying a tack coat of hot air blown bitumen of grade 85/25 in two coats each coat @ 1.2 Kg/Sqm, 1st on bitumen primer and 2nd on polymeric water proofing membrane complete. (e) Applying water proofing membrane not less than 4 kg/sqm in weight, sealing as directed at site with 100 mm over laps as per manufacture's instruction. (f) Applying one coat of aluminium paint @100 gm/Sqm over bituminous surface of membrane. Note : Supply only WPC shall be measured and paid separately under relevant item.
S&F in repair for 10ltrs capacity flushing cistern PVC low level valve less, symphonic action type flushing cistern white with inlet, ball valve, float and handle including brackets and 32 mm flush pipe of polyethylene, complete all as specified and directed.
S&F 15mm dia angle stop valves cast copper alloy fancy type,chromium plated complete all as specified and directed.
S&F in repair 20mm bore stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe, complete all as specified and directed.
S&F in repair, 15mm bore bib taps cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule, complete all as specified and directed.
S&F for 15mm bore stop valve cast copper alloy, fancy type chromium plated with long shank and cup (concealed) screwed down,high pressure with crutch or butterfly handle, screwed both ends for iron pipe, complete all as specified and directed.
S&F in repairs for shower rose chromium plated with or without swivel joints 75 mm dia, complete all as specified and directed.
S&F in repair for vitreous china squatting pan ORRISA Pattern of size 580x 440mm white with integral foot rest and 's'or 'p trap'complete (excluding cistern and flush pipe) with provn of lime concrete including backing joints, complete all as specified and directed.
S&F for vitrious china wash basin, white flat back size 550 x 400 mm including waste, chain & plug and poreclain stopper and bracket etc. Complete including cutting for and pinning in ends of brackets or errecting bracket and 32mm dia waste fitting brass chromium plated for WHB etc;with long screwed shanks and fly nuts,flange end bedded in red lead cement including 32mm dia waiste pipe fitted, complete all as specified and directed.
S&F for pillar tap of 15mm dia bore pipe, fancy type cast copper alloy with capstain head chromium plated with or without lettered “hot or cold” with long screwed shanks and fly nuts screwed for iron pipe fixed, complete all as specified and directed.
S&F PVC connection pipe of 15 mm dia and 45 cm long to WHB and flushing cistern, complete all as specified and directed.
S&F in repair stainless steel kitchen sink with drainage board 1 mm thick including bedding in cement mortor on to dwarf wall or including fixing centilever brackets over all size 915 mm x 460mm bowl size 410 mm x 330 mm x 160 mm and including 38/40mm dia waiste pipe, complete all as specified and directed.
S&F stainless steel uternsil rack not less than 1 mm thick of approved quility and fixed in kitchen, complete all as specified and directed.
Disconnecting existing tank of capacity exc.250 & n.exc 500 ltrs, setting aside lowering if required for repairs cleaning etc and hoisting if required reconnecting and refixing in position.
S&F 500 ltr capacity Rotational moulded polyethylene water storage tank (cylindrical vertical closed top) hoisted and fixed in positions all as specified in SSR Part-I,including 20 mm dia of ball valves high pressure of PTMT with epoxy coated aluminium rod & hi ghdensity plastic ball screwed for iron pipe and fixed.
M&L 20 mm thick granite tiles machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing as in kitchen slab, complete all as specified and directed.
M&L for applying three coats of white wash on newly plastered surfaces on wall after necessary preparation of the surface, complete all as specified and directed.
M&L for applying three coats of white wash on old plastered surfaces of ceilings after necessary preparation of the surface, complete all as specified and directed.
M&L for preparation of old decorated surface of walls by brooming down and wire brushing etc and applying two coats of white wash on wall complete all as specified and directed.
M&L for Preparation of old plastered or unplastered surfaces of ceiling and applying two coats of white wash to ceiling, complete all as specified and directed.
M&L for preparing newly plastered surfaces on walls/ceilling and applying two coats of distemper oil emulsion over JK wall care putty (two coats) including necessary chalk whiting and priming coats, complete all as specified directed.
Complete removal of existing treatment of walls/ ceiling and applying two coats of distemper oil emulsion over JK wall care putty (two coats) including necessary chalk whiting and priming coats, complete all as specified directed.
M&L for preparing the newly surface of any description not otherwise described over 10 cm width or girth on steel surface and applying two coats of synthetic enamel paint over one coat of zinc chromate primer, complete all as specified and directed.
M&L for preparing the new plastered surfaces of wall and applying two coats of cement base paint of any colour over one coat primer, complete all as specified and directed.
M&L Complete removal of existing treatment on wall and applying two coats of cement base paint of any colour over one coat primer, complete all as specified and directed.
M&L for 10 mm thick cement plaster in CM (1:4) for backing of tiles, complete all as specified and directed.
M&L for coloured glazed ceramic tiles in vertical surface 300x450x7to8mm thick set and jointed in neat cement slurry & pointed in white or coloured cement to match the surfaces, complete all as specified and directed.
M&L for 15 mm thick screed bed or bedding layer in CM (1:6), complete all as specified.
M&L non skid coloured ceramic tiles 7 to 8 mm thick(square/rectangular) area of each tiles exceeding 0.11 sqm but n.exc 0.18sqm infloor etc;set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces, complete all as specified and directed.
M&L for light shade vitrified ceramic tiles 10mm thick (square/rectangular) polished, area of each tiles n. exceeding 0.36 sqm over 15 mm thick screedbed in CM (1:6) in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and directed.
M&L for machine cut Kota stone slab flooring 18-20 mm thick (square or rectangular size.) over cement screed bed laid and pointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and directed.
All as per item No 101 above but on vertical surface as dado/ skirting.
S&F 18/19mm dia fancy type curtain rod fixed in position including fixing decorative type bracket, complete all as specified and directed.
S&F CP soap tray fixed with rawl plugs, complete all as specified and directed.
S&F brass CP tubular towel rail 20mm dia D type 60cm long between flanges, complete all as specified and directed. Make : Seiko/Parko
S&F Glass shelf of size 500mmX125mm consisting sheet glass with CP brackets and CP frame Size 500mm long, complete all as specified and directed.
Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc.Removing materials to store in safe custody or for taking credit and making good distrubed surfaces of walls, floors etc, complete all as specified and directed.
M&L for point wiring alongwith earth continuity conductor with 1100 volts grade PVC insulated and FR multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black, Earth - Green) FRLS grade dwawn in and including PVC casing and caping not less than 20mm size and fixing accessories and sunken galvanized pressed steel terminal boxes of thickness not less than 1.12 mm covered with 2.80 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulators complete including 1.0 sqmm copper stranded earth wire for all as specified for the following :-
One light point controlled by one switch.
One fan point controlled by one switch.
One bell point controlled by one switch.
One socket outlet 3 pin 5 Amp controlled by one switch on the same board.
One socket outlet 3 pin 5 Amp controlled by one switch on indepdendent board.
M&L for point wiring alongwith earth continuity conductor with 1100 volts grade PVC insulated FR multistranded copper conductor cable 2.5 sqmm (Phase - Red, Neutral - Black, Earth - Green) FRLS grade dwawn in and including PVC casing and caping not less than 20mm size and fixing accessories and sunken galvanized pressed steel terminal boxes of thickness not less than 1.12 mm covered with 2.80 mm thick phenolic laminated white sheet cover for one 6 Pin 15 Amp socket outlet controlled by one switch on independent board.Incl. 1.5 Sq mm copper conductor earth wire and connected to common earth dolly on independent board.
S&F angle holder, insulated polycabonate body with back plate, complete all as specified and directed.
S&F switch piano flush button single pole one way 5/6 amp, complete all as specified and directed.
S&F switch socket combination two in one 5 and 15 Amps multipurpose flush type universal 240Volts. Make - Anchor / Leader / SSK as approved.
S&F socket outlet 2 in 1, 5 pin, 5/6 amp, flush type, complete all as specified and directed.
S&F ceiling rose 63 x 25 mm three terminals, complete all as specified and directed.
Taking down U/S fan regulator and Supplying and fixing hum free electronic step fan regulator 120 - 280 volts of 100 watt capacity (socket type) including connecting up, complete all as specified and directed.
S&F integrated LED Bulb 9 watt, complete all as specified and directed. Make - Philips or Havells or Syska
S&F LED tube light fitting 1x20/18 watt 230 Volt box type housing extruded aluminium heat sink, driver unit , etc complete with all accessories internally pre-wired and inncluding connecting up with twin core twisted flexible copper conductor cable with suitable size . Cat No-LHEXBHP7IN1W018 of Havells or /Bajaj/Philips
S&F CFL bulk head fitting 1x 9 watt with LED Bulb including connection with PVC insulated flexible flat twin core multi stranded copper conductor cable 0.5 Sqmm as required.
S&F powder coated, CRCA steel sheet MCB distribution board double door (minimum thickness 1.2 mm & constructed as per IS : 8623), degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces etc as required of following ratings & ways :-
SPN, 240 volts, 4 ways.
SPN, 240 volts, 8 ways
Taking down U/S MCBs/ELCBs with incoming and outgoing controls any make, any capacity after disconnecting, complete all as specified and directed.
S&F MCB SPN 6A to 40A 240V 9KA
S&F MCB SP 6A to 32A 240V 9KA
S&F Exhaust fan 300 MM sweep including cutting and chesing ,making hole for fixing, complete all as specified and directed. Model No-Turbo force of Havells.
S&F Ceiling fan 1200mm sweep 5 star power in put 43 watts, Speed 330 RPM including taking down old ceiling fan and deposite to E/M store yard. Model No-Fusion -50 of Havells.
M&L Bell push , flush type , 5 Amp, complete all as specified and directed.
S&F Bell , AC 230 Volts single pole, complete all as specified and directed.
Supply and install high wall split units indoor/outdoor complete with cordless remote control unit and with in built heating and cooling arrangement and Digital inverter twin rotary of capacity 1.5 TR, complete all as specified and directed. (Mimimum 3 star raging EER 3.2, Copper condenser coil based).
Supply and draw submain wiring with two run of single core 4 Sqmm FRLS PVC insulated copper cable 1100 volts grade multistranded, un sheathed conductor in PVC casing and caping 1x 4 Sqmm multistranded FRLS PVC insulated copper wire for earth continuity conductor connected to common earth dolly complete and making good disturbed surface, complete all as specified and directed.
S&F single pole and neutral enclosure with a two pin and earth plug and socket with one single pole MCB 20-32A.
S&F Desert Cooler electric driven (single phase), having nominal air flow water tank capacity of 4000 CuM per hour (or nearest size) 240V Plastic/PVC Body.
M&L structural steel work with Fe-290 (Gde E-165) with compound girders and stanchions, latice girders, aerial masts, staging for water tanks and like including caps, bases, splices etc built up from two or more beam or channel sections or agnles with plates, including all latice bars, stiffeners, gsset plates etc all as directed.
M/S Anjan Kumar Singh
M/S VIKAS CONSTRUCTION CO.
M/S Sweta Construction
M/S DILIP KUMAR
Balaji Construction And Company
M/s Dwarika Nath Singh
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .