Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 CrAccepted-AOC NO157 14 13TH B MAIN ROAD 1ST STAGE 1ST PHASE GOKULA BANGALORE 560054 | BENGALURU URBAN | KARNATAKA | 560054 | ₹2.4 Cr | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹2.4 Cr+₹4.4 L (1.85%)Rejected-Finance | ₹2.4 Cr+₹4.4 L (1.85%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹2.8 Cr+₹40.2 L (17.1%)Rejected-Finance | ₹2.8 Cr+₹40.2 L (17.1%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹2.8 Cr+₹47.7 L (20.3%)Rejected-Finance | ₹2.8 Cr+₹47.7 L (20.3%) | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹2.9 Cr+₹52.9 L (22.5%)Rejected-Finance NO 28 4TH A CROSS 1ST MAIN ROAD ATTUR LAYOUT YELAHANKA NEW TOWN BANGALORE 560064 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560064 | ₹2.9 Cr+₹52.9 L (22.5%) | L5 | Rejected-Finance Not being L1 |
Tender Value
₹2.7 Cr
EMD Value
₹3.5 L
Closing Date
15 Jul 2020, 6:00 pmClosed
CE AF BANGALORE
Chief Engineer AF Bangalore No. 2 DC Area MES Road Yeshwantpur Post Bangalore 560022
PROVISION OF PERIMETER ROAD, PERIMETER LIGHTS,WATCH TOWERS, SUB GUARD ROOM AND ASSOCIATED WORKS AT AF STATION,CHIMNEY HILLS, BANGALORE
2020_MES_345353_1
801429/E8
Open Tender
Civil Works
Lump-sum
456 days
AGE (I) (AF) Chimney Hills
As per NIT
8 documents required · 8 mandatory
₹2,000
Yes
AGE (I) (AF) Chimney Hills
₹3.5 L
Yes
CE AF BANGALORE
21 Aug 2020
16 May 2020
16 Jul 2020
16 May 2020
15 Jul 2020
1 Jul 2020
16 May 2020 - 25 May 2020
5 Jun 2020
Amount
REVISED BOQ UPLOADED ON 27 June 2020
NOTE: Schedule ‘A’ Part-I toI X are under Ser No. 3.00 to 11.00 are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the contractor for “Building Works” as listed in Schedule ‘A’ Part–I
Lumpsum price worked out by the contractor for “Site Clearance” as listed in Schedule ‘A’ Part–II
Lumpsum price worked out by the contractor for “Internal water supply” as listed in Schedule ‘A’ Part–III
Lumpsum price worked out by the contractor for “Internal Electrification” as listed in Schedule ‘A’ Part–IV
Lumpsum price worked out by the contractor for “Sewage Disposal" as listed in Schedule ‘A’ Part–V
Lumpsum price worked out by the contractor for “Water Coolers” as listed in Schedule ‘A’ Part–VI
Lumpsum price worked out by the contractor for “Air Conditioners/Geysers” as listed in Schedule ‘A’ Part–VII
Lumpsum price worked out by the contractor for “External water supply” as listed in Schedule ‘A’ Part–VIII
Lumpsum price worked out by the contractor for “External Electric Supply” as listed in Schedule ‘A’ Part–IX
SCHEDULE `A' PART - X -Fittings, fixtures and Miscellaneous items is not prepriced by MES. Bidder shall insert their rates in Green filed under Col-6.
INTERNAL WATER SUPPLY S&F 15mm bore health faucet cast copper alloy chromium plated including necessary fittings complete all as specified and as directed.
S&F 15mm bore angle cock to, fancy type cast copper alloy CP chromium plated with fittings complete all as specified and as directed.
S&F chrominum plated shower rose ,15mm size with or without swivel joints, including fixing to GI pipe.with fittings complete all as specified and as directed.
INTERNAL ELECTRIFICATION Supply , hanging and connecting up energy efficient, five star rated ceiling fan of size 1200mm sweep complete with stepped type electronic regulator and down rod including provision of flexible copper cable 3 core of size 0.5 sqmm from ceiling rose to fan, including writing MES No 2cm height with synthetic enamel black paint complete all as specified and as directed Make: HAVELLS Rated 5 Star type : ES 50 Premium 5/ Orient Model - Smart saver 50/Crompton or equivalent of makes as listed here-in-after.
Supply and fix and connecting up Heavy duty Exhaust fan of size 300mm sweep 1400 rpm complete,with cable 3 core of size 0.5 sqmm from ceiling rose to fan, provision of 3mm thick bakelite sheet cover including writing MES No 2cm height with synthetic enamel black paint all as specified.Make shall be of Havells Turbo Force /Crompton/Orient heavy duty or equivalent of makes as listed here-in-after.
M&Lfor sub main wiring complete with two runs of 4.0 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20mm dia rigid non metallic PVC and conduit accessories concealed/ roof/wall all as specified and as directed. Note: Two runs of FRLS cable,1 run of earth continuity conductor cable and one run of non metalic PVC conduit shall be measured as one length/running metre.
Supply, Fixing and testing of 4ft LED tube light fiitings batten type 20 Watts,230 volt with system level electronic driver with voltage range of 120-270 volt with LED 20 Watt complete with all acessories internally pre-wired and connecting up with and including provision of three single core twisted flexible copper conductor size of 0.5 sq mm from ceiling rose to light fittings all as specified and directed.(Make Philips Cat No BN21CLED 20S PSU CDL GR or equivalent of makes as listed here-in-after. Note- (a)The contractor shall submit warranty certificate from manufacturer for both light and driver .(b) For all other mandatory requirements of LED fittings, please refer PS Clause No..43.6 on Sl Page No.173
Supply, Fixing and testing of 2ft LED round down light recess mounted for modern interiors with die cast aluminium housing, wattage 10 watt, voltage range of 120-270 volt and surge protection of 1.5 KW with LED 10 watt complete with all acessories internally pre-wired and connecting up with and including provision of three single core twisted flexible copper conductor size of 0.5 sq mm from ceiling rose to light fittings all as specified and directed. (Make-Philips Cat No BBS170 1XDLED-5000 PSU WH or equivalent of makes as listed here-in-after. Note- (a)The contractor shall submit warranty certificate from manufacturer for both light and driver .(b) For all other mandatory requirements of LED fittings, please refer PS Clause No..43.6 on Sl Page No.173
Supply, Fixing LED Bldg security light fittings, with pressure die cast LM6 aluminium housing and has lenses specially desighned for street lighting with a system wattage of 20 watt, it has an electronic driver complaint to IEC safety standards with a voltage variation range of 12-_270 V including provision of necessary GI tubing, medium grade of suitable dia and length with GI clamps, nuts and bolts etc for fixing of the fitting complete all as specified. Make : Philips Cat No BRP022 LED 20 CW MR S1 PSU GR or equivalent of makes as listed here-in-after. Note- (a)The contractor shall submit warranty certificate from manufacturer for both light and driver .(b) For all other mandatory requirements of LED fittings, please refer PS Clause No..43.6 on Sl Page No.173
S&F MCB SP, 6-32 Amps, 240 Volts, 50 Hz, AC supply, "C" curve, with breaking capacity of 10 kA complete all as specified and as directed. Make- Legrand cat No 408587 to 408595 or equivalent of makes as listed here-in-after
S&F MCB SPN, 6-32 Amps, 240 Volts, 50 Hz, AC supply, "C" curve, with breaking capacity of 10 kA complete all as specified and as directed. Make- Legrand cat No 408609 to 408617 or equivalent of makes as listed here-in-after
S&F MCB TPN 40 to 63 Amps 240 volts 10 KA 50 HZ, C curve complete all as specified and as directed. Make- Legrand cat No 408681 to 408683 or equivalent of makes as listed here-in-after
WATER COOLER S&F voltage stabilizer wall mounted type single phase input 170 to 250 volts output 220 to 230 volts with time delay and relay of suitable capacity for water cooler complete all as specified and as directed.
AIR CONDITIONING Supply, install, connect, test and commissioning of hi wall split air conditioner units indoor / outdoor complete with cordless remote control unit, with in built air ioniser, bio filter for better indoor air quality, leakage detector etc. with Invertor technology of capacity 1.5 TR, complete all as specified and as directed by the Engineer in Charge.
S&F voltage stabilizer wall mounted type, air cooled, single phase designed for input variation 170 to 250 volts and output voltage stabilized at 230 volts+/- 2.5% accuracy of capacity suitable for 1.5TR AC complete all as specified and as directed.
S&F water heater storage type electric capacity 25Ltrs BEE 5 star rated 2KW, 230Volt,50Hz complete all as specified and as directed.
S&F hard PVC connection 15mm dia heavy duty 45mm long, both the ends threaded for hot/cold water supply to water heater inlet/outlet connection complete all as specified and as directed.
EXTERNAL WATER SUPPLYConstruction of brick masonry valve chamber of internal dimension 0.60mx0.60mx0.60m PCC 1:4:8 type D-2 foundation brick wall built in cement mortar 1:4, PCC 1:2:4 type B-1 for coping ,rendering in cement mortar 1:4 on internal and external surfaces 150mm below ground level including provisioning of MS sheet cover using angle iron 40x 40x6 mm as in frame embedded in concrete. MS sheet 2 mm thick as in cover with 40x6 mm FI all round and at diagonal and 12 mm dia 300 mm long hinges and locking arrangements etc., complete duly coated with one coat of metal primer and two coat of grey colour painting including necessary excavation and earth work as shown on drawings complete all as specified and as directed by Engineer-in-charge
M&L for drilling of trial borewell in any type of soil / rock 200 mm dia with the help of drilling machine / rig by rotary method or any approved method including other required T & P for depth from 0 to 60m deep below GL complete all as specified and directed.Note :(i) Collection of sample of borewell shall be done at every 5 M depth and stored in small plastic container duly marked the depth and type of strata on the container.(ii) Borewell strata chart duly marked on drawing shall be submitted by the contractor
Description all as per item no 31 above but depth exceeding 60m but n. exc 120m deep below GL.
Description all as per item no 31 above but depth exceeding 120m deep below GL .
Supplying, lowering, assembling and fixing in position 200 mm nominal bore ERW (heavy duty) mild steel housing pipe plain ended of 5 mm wall thickness as per I.S4270 / 3589, painted with black bituminous paint suitable for drinking water purpose both inside & outside including electric arc welding with MS flat iron of size 80 x 6 mm, coupling around the pipe of suitable length complete as centre guide confirming to IS 3589 of 2001 all as directed. Note:(i) welding shall be done on both sides of sockets.(ii) Pipes shall be in full length of approx 6 m long
Developing / flushing of tube wells by compressed air with minimum pressure of 10 kg/Sqcm and after with 25% extra capacity pump by pumping muddy water complete all as directed.Note :(i) Required T & P , pumpset etc are deemed to be included in the quoted rates. (ii) Electric supply shall be arranged by the contractor.
Yield testing for the tube well with the help of V notch tank 90 degree by continuous pumping to determine safe pumping yield complete all as directed
Chemical and bacteriological testing of sample from approved NABL laboratory to ensure potability of water complete all as specified
S&F water pressure gauge 0 to 10 kg/ sq cm including drilling and welding of 15 mm GI socket to pipe complete all as directed by Engr- in -charge
Supply and fix cast iron non return valve 50mm dia, ISI marked, both ends flanged including rubber gasket, MS Nuts, Bolts & washers and testing complete all as specified and directed
Supply & fixing flat iron clamps,450mm length of 75 x 6 mm size with nut,bolt & washer complete for holding 50 mm GI Pipe
Supply & fixing of well cap of 200 mm dia size on top of the pipes with locking arrangement complete all as specified and directed
Supply , installing, testing and commissioning of 15 HP , 3 phase , 440 volts, 50 Hz submersible pump suitable for 200 mm outer diameter casing and having steel body stainless steel impellar , multistage , water lubricated bearing , coupled with suitable capacity submersible motor , ISI marked ,pump design shall be based on yield obtained in borewell and required head , including lowering into the borewell with, column pipe of 50 mm galvanized medium grade each 3 mtr. long with submersible cable etc complete in all respect and all as specified and directed by Engineer-in-Charge. Note :- i) Particular model, head, discharge and stagings of pumpset of 15 HP shall be approved by the AGE(I) based on head and discharge characterstic curve as per manufacturers manual after satisfactory yield obtained in the tubewell ii) Motor control panel , submersible cable , GI column tubing shall be measured and paid separately under respective item. rates quoted deemed to be inclusive of provision of T& P required for lowering of submersible pump cum motor in the unit rates
Supply , installing, testing and commissioning monoblock Pump set, electric driven 415 volts, 50 Hz, 3 phase AC supply of capacity 5 HP including PCC foundation complete all as specified and as directed.
S&F PVC Insulated and PVC sheathed,flat, industrial cable 3 core,6Sqmm,1100volts grade for submersible pump motors complete all as specified and as directed.
Supplying and lowering of Galvanized pipe of size 50mm dia (Heavy grade) in the tube well with heavy duty collar long GI Sockets complete all as directed..
Supply, Installation, testing and commissioning chlorine Dosing system, high pressure single head adjustable chlorine dosing system including following accessories : - preparation tank of net capacity 170 ltrs. FRP dosing tank dia 650 x net Height 375 + conical 300 mm. Gross height with stand 1000 mm consisting of water inlet line, outlet with Y strainer 'Drain, Overflow, Conical bottom for sludge deposition, pot hole with cover, Level gauge. Agitator 120 Watt 9OO RPM single phase flange mounted motor with shaft and impeller and Service tank of net capacity 100 ltrs' of FRP dosing tank Top dia 540mm x Bottom dia 480mm x Height 575mm consisting of water inlet line, lnjector Dosing pump inlet arrangement, Drain, overflow level gauge, inspection port complete all as specified and as directed.
Supply and fixing LT Panel CPRI type tested, made of powder coated cubical out door type pedestal mounted and ingress of protection IP 64 with sufficient working space and weather proof vermin proof febricated out of 3.15 mm thick CRCA sheet and 40x40x4 mm angle iron base frame fixed on and including PCC (1:3:6) type C1 and comprising of the following:- (For Submersible Pumps) (a) 4 Nos Bus bar of equal size of aluminium with PVC coloured heat shrinkable type sleeves, continous rating of 100 AMPs mounted on fibre reinforced insulator (b) MCCB 4 Pole with Microprocessor based release 100 Amps 415 Volts 16 KA -1 No. (incoming) (c) Protection relay for submersible pump set( under voltage/ over current /phase reversal/ dry run) -1 No. (out going) (d) Fully automatic star delta starter 415 volts suitable for 15 HP Submersible pump set ---1 No .(e) Voltmeter Digital type 0 - 500 volts - 1 No (f) Ammeter Digital type o to 200 Amps with suitable CTs- 1 No. (g) Indication lamp panel mounting complete with all fittings RYB - 3 Nos.
M&L for earthing complete with GI earth plate 600 mm x 600 mm x 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of the earth plate to a depth not less than 1.5 m below ground level, connected to and including GI strip 25x4 mm with GI protection pipe 40 mm dia light grade connected upto panels/DBs by means of bolts, nuts, check nuts and washers , galvanized iron medium grade 20 mm bore for watering and including funnel, wire mesh,charcoal, lugs, common salt ,PCC chamber with PCC 1:3:6 type C2 including excavation and earth work, disposal of surplus soil to a distance not exceeding 50 m, RCC 1:2:4 cover slab 50 mm thick with re-inforcement of 8 mm TMTHCR/CRS bars @ 100mm c/c both directions and lifting handle complete all as specified and as shown on electrical plate No.3 of SSR Part-I .
Providing trenchless bore by using mechanical pneumatic drilling equipment for passing electric cables through HDPE pipe of 150 mm dia 6 mm thick in the the existing bituminous/WBM road/PCC hard standing/ hard soil / loose soil depth range not less than 1.0 mtr and up to 2 mtr and making good the disturbed surfaces all as directed by Engineer- in- charge.Note :- (i) Quoted rates shall be deemed to be inclusive of necessary earth work, transportation charges of drilling plants and connected complete tools, cost of 150 mm dia 6mm thick HDPE pipe and passing pipe through bore complete.(ii). Any damage to MES/User/Private assests caused during trenchless bore operation shall be rectified by the contractor on his own cost.
EXTERNAL ELECTRIFICATION M&L for earthing complete with galvanized steel earth plate electrode of size 600mm x 600mm x 6mm thick, buried directly in ground vertically to a depth not less than 2.25 Mtr below ground with top edge of the earth plate not less than 1.5 mtr below normal ground level, Earth plate shall be connected with double bolts, nuts, check nuts & washers, to & including 32x6 mm galvanized iron strip as earth lead, extended upto 7.5 m or upto test terminal point, drawn through 40mm dia med. gr. GI pipe for protection of galvanized iron strip in the ground, including excavation, earth work, Charcoal & Salt all as specified, PCC chamber, RCC cover slab, watering pipe 20mm dia bore med. grade, wire net, funnel etc. & testing on completion all as specified in plate No.3 of SSR Pt-I, including breaking and removing the old unsv earth materials complete all as specified and as directed.
M&L for earthing complete with galvanized earth plate electrode 60cm x 60cm x 6 mm thick, burried directly in ground (earth pit not less than 2.25 Metre, deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to 4 mm dia GI wire by means of bolts, nuts, washers, check nuts of galvanised iron or steel all as specified or indicated including excavation and earth work PCC 1:2:4 type B-1(using 20 mm graded aggregate) in chamber RCC cover 40mm thick in 1:2:4 type B-1 (20mm graded aggregate) with 8 mm MS rod as 15cm in both ways with hooks, funnels with watering pipe, wire mesh and copper lugs,GI protection pipe and testing on completion.
Supply and fixing Cable joint kit 1.1 KV grade cable for straight through joint complete with jointing materials (Epoxy Based) and accessories suitable for 3.5 / 4 core XLPE armoured Aluminium conductor cable of size 25 to 50 sq mm.complete all as directed.
Supply and fixing Cable route indicator of size 200x150x6 mm cast iron disc with letters embosed on both side as LT UG cable & with arrow sign fixed on 25 x 25 x 6 mm mild steel angle iron 450 mm long embedded in PCC block (20 x 20 x20 cm ) in PCC 1:3:6 type C2 using 40 mm graded stone aggregate all as specified including two coats of synthatic enamel paint over a coat of red oxide primer on exposed steel surface.
Supply and fixing PVC weather proof junction box of size 300x200x105mm Make: Sintex(Model No GSJB-3020) with hinged door locking arrangement and consisting of 01 No panel mounted connector 4 pole 6 A -MCB 1 No, with suitable size flanged type brass cable entry glands confirming to IP 65 complete including necessary fixing arrangement on street light pole complete all as specified and as directed.
Supply and fixing GI pipe bracket 40 mm dia , medium grade , 1.2 mtrs long bend to shape suitable for fixing street light on pole fixed with MS clamps, bolts, nuts, washers etc. complete all as specified and as directed.
M & L for submain wiring on Street light poles complete (from PVC junction box to light fitting) with 2 runs of single core, PVC insulated cable of size 2.5 sqmm 1100 volts grade, unsheathed copper conductor multistranded drawn into and including PVC conduit 20 mm dia and conduit accessories alongwith one run of earth continuity conductor of size 2.5 sqmm complete all as specified and as directed. Note: Two runs of 2.5 sqmm cable, one run of 2.5 sqmm cable for earth continuty and one run of PVC conduit and conduit accessories will be measured and paid as one unit.
Supply and fixing Digital Timer Switch with contactor ML 3, 40 Amp 415 Volt, MCB TPN 40 Amp in sheet steel enclosure fixed on wall at Watch Towers for auto ON / OFF purpose all as specified and as directed.Make: HAVELLS part No IHXTS 03060 or equivalent of makes as listed here-in-after
S&F MCB DB TPN 4 Way Vertical type double door with MCCB TPN 63 Ams - 1 No, MCB TP32 A -01 No, MCB SP 6-32 Amps -08 Nos,in sheet steel enclouser fixed on wall at Watch Tower complete all as directed at site.
Supply, installing, testing and commissioning of Acoustic proof type silent diesel engine driven generating set fully wired 415 V +/- 5% AC 3 phase, 4 wire 50 Hz having capacity 50 KVA/ 40 KW continuous rating, power factor 0.8 (lagging) as per IS-4722 and connections as per IE rule. DG set mounted on a common base plate with anti vibration pad mounting including foundations as recommended by manufacturers. The Gen set shall conform to CPCB norms for noise and emission limits and necessary certificate from ARAI to the effect shall be submitted, complete with AMF control panel board with engine safety unit all as specified and directed consisting of the following:- (a) Diesel Engine : The engine shall be water cooled, turbo-charged after cooled type, all service points such as dipstick, lube oil filling, lube oil filter, fuel pump, injectors shall be on cooler side and injectors shall be housed outside rocker cover to enable easy maintenance. Engine rating shall be 79 BHP, prime @ 1500 RPM at NTP, configuration 90 degree V type, 6 cylinder turbo charged with air to air after cooler, governor mechanical type, mechanical type feed pump, exhaust and silencer pipe and insulated with glass wool and aluminium cladding safety devices and other standard fittings such as speedometer/hour meter etc complete as per IS 10002 part-II, 1980 and BHP suitable to the generator
((b) Alternator : The alternator shall be designed for an output of 50 KVA/40 KW continuous rating ar 0.8 PF, screen protected drip proof , in IP 21 enclosure and closed coupled with engine, with class H or better insulation and confirming to IS-13364, rated RPM 1500 including self excited, self regulated, brushless and self ventilating type, control panel with accessories, electric supply terminal box with gland, earth terminal etc complete all as specified. (c) AMF control panel board : The AMF control panel board including microprocessor based engine safety shall have the followings : (i) Controller with key switch/auto start having multifunctional meter which display the following parameters, Voltage, Current, Frequency, Water temprature, Oil pressure, KVA and KW.(i) MCCB 100 Amp 25 KA 4 Pole -02 Nos for incomming/ Out going (ii) LCD hour counter (iii) Key switch for OFF, Manual and auto (iv) LCD lamp indicator for the following features.(aa) Fail to start (ab) Over speed, Under speed (ac) Low oil pressure (d) Electrical system : The electrical system of the starter motor and charging alternator shall have the folowing components :- (i) Charging alternator 12 V DC X 45 amp alternator (ii) Voltage regulator built in type IC regulated (iii) Starter motor 12 volts DC X 6.6 KW (iv) Battery, 12 V, DC and suitable capacity, one number including connecting terminals with electronic type float cum boost battery charger
(e) Fuel tank : The fuel tank shall be mild steel suitable to hold fuel for not less than 12 hours running capacity and shall be including fuel level indicator duly marked, fuel line from tank to the engine, arrangement for fuel filling, fuel drain out facility etc complete as specified (f) Civil Works:All civil works including PCC platform for mounting DG set and related to foundations including for AMFpanel foundation and equipments including making good and existing structrure of disturbed during installation and commissioning of genset. The depth of the foundation shall be minimum 300 mm with antivibration pads or as recommended by the manufacturer. Note : (i) LT UG cable for connection between generator, AMF panel and LT panel will be measured and paid separately (ii) Diesel, engine oil etc required for commissioning and testing shall be deemed to be included in quoted rate (iii) The contractor shall arrange for artificial load for testing for final testing of DG Set at site and the cost is deemed to be including in the quoted rate.(iv) Testing of sound level should be carried out at the site in presence of Engineer-in-Charge. (v) DHPP for testing purpose shall be supplied by the contractors without any extra cost to Govt
Supply and fixing LT Panel CPRI type tested, made of powder coated cubical indoor type floor mounted and ingress of protection IP 54 with sufficient working space and weather proof vermin proof fabricated out of 2 mm thick CRCA sheet and 40x40x4 mm angle iron base frame fixed on and including PCC (1:3:6) type C1 and comprising of the following: (a) 4 Nos Bus bar of equal size of aluminium with PVC coloured heat shrinkable type sleeves, continous rating of 400 AMPs mounted on fibre reinforced insulator (b) MCCB 4 Pole 250 Amps 415 Volts 35 KA-1 No (Incoming) (c) MCCB 3 Pole 100 Amps 415 Volts 25 KA-5 Nos.(d) MCCB 3 Pole 63 Amps 415 Volts 16 KA-5 Nos (e) Voltmeter Digital type 0 - 500 volts - 1 No (f) Ammeter Digital type o to 250 Amps with suitable CTs - 1 No.(j) DOL starter 415 volts suitable for monoblock pump set 5HP -2 Nos .
Supply and fixing LED 80 W street light made up of pressure die cast aluminium housing with 10 KV built in surge protection, IP 66 protection and connecting 3 core 2.5 sqmm of length 8 mtr multistranded copper conductor PVC insulated weather proof cable complete with fittings all as directed Make: HAVELLS cat part No ENDURAPEARLPLUSSL80WLED755SASYTOPC or equivalent of makes as listed here-in-after. NOTE: For all other mandatory requirements of LED fittings, please refer PS Clause No..43.6 on Sl Page No.173.
Supply and fixing LED Flood light fitting with and multiple LED Lamps having LED wattage 150 light fixture integral type with pressure die cast housing with IP 66 protection, reflector, drivers, hear resistance temperature glass for protection with 5 KV surge protection and accessories including MS bracket / angle suitable for fixing on street light pole / wall fixed with MS clamps, bolts, nuts, washers etc. Make : Havells Cat No: JETAIRISFLS 150W LED757PSYMLTG OR or equivalent of makes as listed here-in-after. NOTE: For all other mandatory requirements of LED fittings, please refer PS Clause No..43.6 on Sl Page No.173.
Supply and fixing LED Decorative Post -Top lantern for 35W watts including aesthetically designed decorative hot dipped galvanized mild steel pole with gray powder finish 3.5 length with PCC foundation with fixing arrangements Make :- Havells CAT No.:- VICTORIAPT35WLED730PSYMTOTG or equivalent of makes as listed here-in-after. NOTE: For all other mandatory requirements of LED fittings, please refer PS Clause No..43.6 on Sl Page No.173.
Supply and fixing Bollards light fitting with 8 watt LED aluminium landscape luminaire with diffused lighting Make: Havells CAT No: BAMBOOBL8WLED857SSYMTOPCM or equivalent of makes as listed here-in-after. NOTE: For all other mandatory requirements of LED fittings, please refer PS Clause No..43.6 on Sl Page No.173.
Supply and fixing 39 W Solar LED standalone street light system with 3 day backup, HDG tubular pole 6 m long above the ground level , SPV panels 160(80X2) Wp, DC LMLA (low Maintenance Lead Acid Tubular) Battery 150 Ah with MS box, Charge controller, luminaire wattage 2X39 W, system voltage 12 V with accessories complete mounted on PCC foundation all as directed MAke : Havells / Tata Solar/ Phillips/ CG NOTE: For all other mandatory requirements of LED fittings, please refer PS Clause No.43.6 on Sl Page No.173.
Supply and fixing Integral LED 200 watts Flood light Fitting with pressure cast housing with IP 66 protection, heat resistant tempered glass for protection with 5 KV surge protection compact. Make: Havells Model No: 39 W solar SLS or equivalent of makes as listed here-in-after. NOTE: For all other mandatory requirements of LED fittings, please refer PS Clause No.5.43.6 on Sl Page No.173
RAMYA CONSTRUCTIONS
SREEKRISHNACONSTRUCTIONS
K T ASSOCIATES
Gnani Builders
M/s. P S REDDY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .