Loading…
Loading…
Tender ID
Tender Value
₹1.9 Cr
EMD Value
₹3.8 L
Closing Date
10 Apr 2026, 1:00 pmClosed
SE, NBEC, PWD
Office of the SE, NBEC, PWD, Venusmore, Siliguri
Additional works in connection with Proposed 50 Bedded Critical Care Block G3 storied at North Bengal Medical College Siliguri Electrical Works SITC of Substation Works
2026_WBPWD_1022075_1
WBPWD/SENBEC/eNIT-05/2025-2026
Open Tender
ELECTRICAL WORKS ORG
Percentage
120 days
Siliguri
Please refer Tender documents.
8 documents required · 8 mandatory
₹3.8 L
Siliguri
24 Apr 2026
19 Mar 2026
13 Apr 2026
19 Mar 2026
10 Apr 2026
27 Mar 2026
24 Mar 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | SUB-HEAD I : SITC OF VCB PANEL, TRANSFORMER & LT PANEL | - | - | - | - |
| - | VCB PANEL | - | - | - | - |
| - | Supply, Installation, testing & Commissioning of 11 KV 800 A, short-circuit capacity of 26.3 KA for 1 sec, 3-panel HT Gear with VCBs. The Vacuum Circuit Breaker should comply as per IS:13118& IEC:62271-100 for Circuit Breaker & IS:3427 & IEC:62271-200/IEC 694, IEC-61850 for Indoor panel. The HT panel is rated at 11 KV, 3-Phase 800A, Breaking Current/short-circuit capacity of 26.3kA for 1 sec, 50c/s and shall be of floor-mounting, sheet steel clad, free-standing metal enclosed air insulated switchgear cubicle with VCB inside. | - | - | - | - |
| - | The Vacuum Circuit Breaker is horizontal isolation & horizontal draw out/Vertical isolation & horizontal draw out with 3 compartments and is made of 2mm CRCA sheet for load bearing members with vermin & moisture proof along with automatic shutter arrangement for complete isolation of bars, cable sockets & other live parts etc. when the removable portion is withdrawn. | - | - | - | - |
| - | The breaker is arranged for hand operation through front of the panel push buttons & spring charging mechanism and also electrical motor which will be energized by 230V AC. Closing and tripping coils are rated for 110V DC to be made available from the station 400 V 3 phase 50 C/s A.C. source with remote operation compatibility. All trip coils shall be of shunt trip type energized from a suitable rectifier condenser source supply is required. There is a remote operation through multi core arrangement for closing & tripping. The shutter shall be gravity operated. | - | - | - | - |
| - | INCOMING CIRCUIT BREAKER | - | - | - | - |
| - | a) 3 Phase Star- Star 3 limb draw type line PT 11KV/√3 /110V/√3, 100VA Cl - 1 with fuses for primary & secondary circuit - 1 no. | - | - | - | - |
| - | b) Epoxy Cast, Dual Core Delta/Y-Y CT having CT ratio
150/100/5+5 ,with CORE1:15VA Class-1.0 CORE2 -:15VA, Class- 5P10, STC - 26.3ka for 1 sec- 3 nos. | - | - | - | - |
| - | c) Shunt Trip Coil of 110V DC- 1 no. | - | - | - | - |
| - | d) LED type indicating lamp for VCB ON/OFF, CB Trip,
Springe Charge, Trip Ckt Healthy- 5 nos. | - | - | - | - |
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.50 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.25 MB
Tendernotice_2.pdf
PDF • 1.30 MB
Tendernotice_3.pdf
PDF • 0.16 MB
BOQ_2513321.xls
BOQ • 0.92 MB
DCorri05.pdf
PDF • 0.59 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .