Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹1.4 Cr
EMD Value
₹2.8 L
Closing Date
3 Dec 2026, 5:30 pm7d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
MS PRIYANKA SHARMA(DFLT)
CHIEF ENGINEER ( TENDER CELL)
NIT 1226 PMGSY Road Renewal Maintenance PKG No CG-11-M 42 District- Manedragarh Chirmiri Bharatpur
204213
NIT 1226 PMGSY Road Renewal Maintenance PKG No CG-11-M 42 District- M.C.B.
RESTRICTED TENDER
WORKS
PERCENTAGE
6 days
CHIEF ENGINEER ( TENDER CELL)
Required Past Technical Experience: As per Tender document
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
15 documents required · 15 mandatory
Panchayat and Rural Development (PARD)
WORKS
MS PRIYANKA SHARMA(DFLT)
RESTRICTED TENDER
PERCENTAGE
A B C
CHIEF ENGINEER ( TENDER CELL)
TENDER CELL
CGRRDA RAIPUR
90
06
No
1
204213
3 Dec, 2026 5:30:00 PM IST
7 Dec, 2026 6:05:46 PM IST
18 Nov, 2026 7:30:00 PM IST
NIT 1226 PMGSY Road Renewal Maintenance PKG No CG-11-M 42 District- M.C.B.
NIT 1226 PMGSY Road Renewal Maintenance PKG No CG-11-M 42 District- Manedragarh Chirmiri Bharatpur
283000.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
14130000.00
2
7 Dec, 2026 5:30:33 PM IST
14130000
AS PER NIT
AS PER NIT
As per Tender document
5000.00 INR
14d 21h 29m
15 documents required · 14 mandatory · 1 optional
₹5,000
₹2.8 L
18 Nov 2026
18 Nov 2026
7 Dec 2026
18 Nov 2026
7 Dec 2026
90 days
Detail of Maintenance Work's Roadwise Package
District:- MCB Format - A
PIU :- Manendragarh
S .No. Circle District PIU Block Vidhansabha Pkg. No. Name of Road Length of Road (In Km.) Cost of Maintenance Work's for Five Year's (Amount in Lacs) Add 18 % GST Total Amount Emergency Work's 10% of (B+C) Remark
Initial Rehabitation Work's A Annual Routine Maintenance B Renewal Work's C Total A+B+C
1 Surguja-02 M.C.B. Manendragarh Manendragarh Bharatpur-Sonhat CG-11-M- 42 Manchidand to Kerabahra 6.000 23.61 11.34 84.80 119.75 21.55 141.30 0.00
Executive Engineer
PIU, CGRRDA, Manendragarh
Detail of Maintenance Work's Roadwise Package
District:- MCB Format - B
PIU :- Manendragarh
S .No. Circle District PIU Block Vidhansabha Pkg. No. No. og Road Total Length of Road (In Km.) Cost of Maintenance Work's for Five Year's (Amount in Lacs) Add 18 % GST Total Amount Emergency Work's 10% of (B+C) Remark
Initial Rehabitation Work's A Annual Routine Maintenance B Renewal Work's C Total A+B+C
1 Surguja-02 M.C.B. Manendragarh Manendragarh Bharatpur-Sonhat CG-11-M- 42 1 6.000 23.61 11.34 84.80 119.75 21.55 141.30 0.00
Executive Engineer
PIU, CGRRDA, Manendragarh
PRADHAN MANTRI GRAM SADAK YOJANA (PMGSY)
BILL OF QUANTITY
Manchidand to Kerabahra
Block :- MANENDRAGARH Distt : M.C.B.
Length : B.T. 6.00 + C.C. 0.00 = 6.00 Km Package No. - CG-11-M-42
S.No Item No. Particular Qty. Unit Rate Amount
1 11.12(3) Trimming of grass and weeds from the shoulders/berms and disposing off the same to suitable locations as per technical specifications Clause 1914 14000 Sqm 3.00 42000
2 7.1(I) Excavation for Structure as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. (I) Ordinary soil 352 Cum 394.00 138708
3 7.10(I) Providing concrete for plain/reinforced concrete in open foundation complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (I) P.C.C grade M 10 (Nominal mix 1:3:6) 36 Cum 4614.00 167950
4 7.10(II) Providing concrete for plain/reinforced concrete in open foundation complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 250 Cum 4576.00 1142170
5 7.22 Providing weepholes in brick masonry/stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 87 No. 317.00 27579
6 6.5 Construction of Plain Cement Concrete Drain with P.C.C. grade M-15 including all shuttering/form work etc. complete as per drawings/technical specification and direction of engineer in charge. 74 Cum 4970.00 369023
7 7.27 I (i) Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 R.C.C grade M 20 (i) For nominal mix 1:2:4 (RCC Cover in front of Houses) 7 Cum 6157.00 41560
8 7.28 Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202 1 MT 73726.00 37324
9 7.24 Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8 187 Cum 1751.00 327787
10 7.2 Backfilling behind abutment, wing wall and return wall complete as per drawings and Technical Specification Clause 1204.3.8. 0 Cum 1032.00 0
11 9.14 (B) Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 1 Each 18610.00 18610
12 9.15 (A) Providing and fixing 'Citizen Information Board' of PMGSY Project (A) Providing and fixing of typical " PMGSY Citizen Information Board" with Logo as per MoRD specifications & drawings, made of 75 mm square or 75 mm dia circular steel tube of 12 SWG 3.2 m height and cross member 2 nos 1m long, fixed with angle iron 50x50x5 mm MS angle on the back 1 Each 14010.00 14010
13 9.2 (A) Cautionary, mandatory, informatory direction and place identification sign boards. Semi-Reflective Traffic signs upto 0.90 sqm Direction and place identification signs up to 0.9 sqm size board Providing and erecting direction and place identifications of semi reflective sign boards as per IRC:67 made of 2 mm thick M.S. Sheet duly stove enameled paint in white colour in front and grey colour on back with red reflective border of 70 mm width and required message, letters, figures with reflective engineering grade tape as per MORD specifications of required shade and colour. Supported and welded on 47 mm x 47mm of 12 SWG Square tube of 3050 mm height duly strengthened by 25 mm x 5 mm M/s flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701 6 Sqm 5285.00 34247
14 9.2 (B) Semi-Reflective Traffic signs more than 0.90 sqm Providing and erecting direction and place identifications of semi reflective sign boards as per IRC:67 made of 2 mm thick M.S. Sheet duly stove enameled paint in white colour in front and grey colour on back with red reflective border of 70 mm width and required message, letters, figures with reflective engineering grade tape as per MORD specifications of required shade and colour. Supported and welded on 47 mm x 47mm of 12 SWG Square tube of 3050 mm height duly strengthened by 25 mm x 5 mm M/s flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701 0 Sqm 5756.00 0
15 3.8(i) Construction of unlined surface drains of average cross-sectional area 0.40 sqm in soil to specified lines, grades, levels and dimensions. Excavated material to be used in embankment with a lift upto 3m and lead of 50 m (average lead 25 m) as per Technical Specification Clause 307 1640 RM 99.00 162360
16 11.1 Restoration of Rain Cuts Restoration of rain cuts with soil, moorum gravel or a mixture of these, clearing the loose soil, benching for 300mm width laying fresh material in layers not exceeding 250 mm and compaction with plate compactor or power rammer to restore the original alignment, level and slopes as per drawings and technical specifications Clause 1902 657 Cum 273.00 179446
17 11.2(I) Maintenance of Earthen shoulder (filling with fresh selected soil) - Making up loss of material/irregularities on shoulders to the design level by adding fresh approved selected material and compacting it with appropriate equipment at OMC upto a lead of 1000 m as per technical specification Clause 1903 22500 Sqm 49.00 1102500
18 11.7 (I) (I) Maintenance of Hume pipe Culvert by way of Clearing, Cleaning, Erosion repair, repairs to cracks, parapet wall and protection work as per drawing and technical specification Clause 1908 1 Each 1448.00 1448
19 11.7 (II) (II) Maintenance of Slab type Culverts by way of clearing, Cleaning, Erosion repair, repairs to cracks, parapet walls and Protection works as per drawing and technical specification Clasue 1908 1 Each 3053.00 3053
20 11.13 White washing of parapet walls of CD work and tree truncks White washing two coats on parapet walls and tree trunks including preparation of surface by cleaning scraping etc as per technical specification clause 1915. 91 Sqm 26.00 2366
21 9.5 Painting two coats including prime coat with epoxy paint of approved brand on concrete/steel surfaces after through cleaning of surface to give an even shade as per drawing and Technical Specification Clause 1701 0 Sqm 142.00 0
22 5.2 (ii) (ii) Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503. 23625 Sqm 21.00 496125
23 11.14(I)(ii)(ii) 20mm thick Open-Graded Premix Carpet 0
20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm size @ 0.18 cum per 10 sqm & 11.2 mm size @ 0.09 cum per 10 sqm aggregates using penetration grade/modified bitumen @ 14.6 kg/10sqm to required line, grade a II) Bitumen (VG-30) 28125 Sqm 166.00 4668750
24 11.14.1 (IV) Seal Coat 0
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 ii. Bitumen (VG-30) 23625 Sqm 60.00 1417500
25 9.16 Providing & Fixing of PMGSY 'Logo' board Providing and fixing of typical PMGSY logo board as per MoRD specifications and drawings. 4 Each 6626.00 26504
26 9.8 Kilometre Stone 0
Reinforced cement concrete M15 grade kilometer stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 0
(I) 5th Kilometer Stone (precast) 0 Each 3974.00 0
( ii ) Ordinary Kilometer stone ( precast ) 4 Each 2292.00 9168
( iii ) 200m stone ( Precast ) 16 Each 660.00 10560
27 9.17 Guard Stone Reinforced cement concrete M15 grade guard stone of size 200mmx200mmx800mm, fixeing in position including painting and printing etc. as per drawing and Technical Specification and as per direction of Engineer in charge 80 Each 673.00 53840
28 9.19 Providing and laying rounded hump type of Speed Breaker confirming to IRC – 99 and as per guidelines and drawings of NRRDA circular no. DO No. P-17019/6/2006/PII Dated 16 Sept 2009, including providing, laying and compaction of GSB, G II, G III, OGPC, Seal Coat Type B, as per specifications and appended drawing on both the sides of carriage way up to formation width maintaining rounded hump type shape with bituminous mix material i/c providing and painting of black and white strips, providing and fixing of two no. 600mm equilateral semi reflecting sign boards, i/c cost of all materials, labour T & P & Machinery etc complete and as directed by engineer in charge as per relevant clauses of MORD specifications. 0
(A) For 7.50 M Formation Width 2 Each 22547.00 45094
(B) For 6.00 M Formation Width 0 Each 17153.00 0
29 9.18 Road marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface (Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC: 35. The finished surface to be level, uniform and free from streaks and holes.) 480 Sqm 627.00 300960
For 5 year anual Maintenance
Total Maintance 1134000
Add 18 % GST 2155435
Grand Total 14130075
Say In Lacs 141.301
Sub - Engineer Assistant Engineer Executive Engineer cum Member Secretary
PIU, CGRRDA Manendragarh PIU, CGRRDA Manendragarh Project Implementation Unit
CGRRDAManendragarh DISTT. M.C.B.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
1588435723018103103_159177_1278507194557121433_80616_Guidelines to Bidders.pdf
NIT • 0.13 MB
5561587968748945677_204213_NIT 1226 Tender Document Renewal Maintenance.pdf
NIT • 1.77 MB
6931492670613731691_204213_MCB BOQ CG 11 M 42.xlsx
BOQ • 0.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .