Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.1 CrAccepted-AOC | ₹5.1 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹5.1 Cr+₹1.0 L (0.20%)Rejected-Finance | ₹5.1 Cr+₹1.0 L (0.20%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹5.2 Cr+₹10.7 L (2.12%)Rejected-Finance | ₹5.2 Cr+₹10.7 L (2.12%) | L3 | Rejected-Finance Other than lowest |
| 4 | Rejected-Technical 16 PRATAP NAGAR CHARBHUJA RAWATBHATA RAJASTHAN 323307 | RAWATBHATA | CHITTORGARH | RAJASTHAN | 323307 | - | - | Rejected-Technical As per selection performa attached |
Tender Value
₹5.0 Cr
EMD Value
₹5.7 L
Closing Date
12 Dec 2023, 6:00 pmClosed
Chief Engineer Udhampur Zone
HQ Chief Engineer Udhampur Zone PIN-900386 C/o 56 APO
CONSTRUCTION OF TECHNICAL BULDING AT RAKHMUTHI
2023_MES_623312_1
87928-A/E8
Open Tender
Civil Works
Lump-sum
665 days
Akhnoor
AS per NIT
8 documents required · 8 mandatory
₹2,000
GE (S) Akhnoor
₹5.7 L
Yes
2 Feb 2024
14 Oct 2023
19 Dec 2023
14 Oct 2023
12 Dec 2023
30 Nov 2023
Amount
Sch 'A' Part - I (Building Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as "Rs. 0.00" under col.5 signifies this fact only.
Construction of block of IGLOO building complete all as specified and as shown on drawings. (Note: The building work is deemed to include Vift, side wall, earth traverse.(approved soil brought from out side MD land) etc.
Construction of Static water tank capacity 2,25,000 ltrs complete, all as specified and as shown on drawings.
Total Amount of Sch 'A' Part - II (Road, Path and Culvert)
Total Amount of Sch 'A' Part - III (Area Drainage)
Total Amount of Sch 'A' Part - IV (Fire Point)
Total Amount of Sch 'A' Part - V (Sign Board)
Total Amount of Sch 'A' Part - VI (Fire Seal)
Total Amount of Sch 'A' Part - VII (External Electrification)
Total Amount of Sch 'A' Part - VIII (Lightening Protection)
Total Amount of Sch 'A' Part - IX (External Water Supply)
Sch 'A' Part - X (Misc Items work) Note : This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as "Rs. 0.00" under col.5 signifies this fact only.
Precast cement concrete cubes using M-20 (Nominal mix) of size 250mm x 250mm x 250mm as in dunnage blocks complete all as specified and as directed .
Flame proof, weather proof LED bulk head light 11 watt, indoor type fittings, complete all as specified and as directed.
Flame proof, weather proof distribution board, 6 way with and including accumulated flame proof 01 No MCB SPN 0-10 Amps, 10 KA and 3 No of MCB SP 0-6 Amps, 10 KA, complete all as specified and as directed.
Supply, laying ,jointing and testing, XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor 1100 volts (earthed) grade, cross sectional area 16 Sqmm, 4 core, laid in trenches or fixed to pole /LT panel board /wall complete all as specified and as directed.
Supply, laying ,jointing and testing, XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor 1100 volts (earthed) grade, cross sectional area 10 Sqmm, 4 core, laid in trenches or fixed to pole /LT panel board /wall complete all as specified and as directed.
Supply, laying ,jointing and testing, XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor 1100 volts (earthed) grade, cross sectional area10 Sqmm, 2 core, laid in trenches or fixed to pole /LT panel board /wall complete all as specified and as directed.
Cutting into existing bituminous carpet road/PCC hardstanding upto a depth of 30cm for laying of underground cable/GI pipe and making good the disturbed surfaces to match with existing, complete all as specified and as directed.
Junction box water proof outdoor type made out of SMC of external dimensions 250x250x105mm, sigle door type hinged with locking arrangement front operated with one number MCB 06 Amps capacity for housing 3 phase and neutral busbar including connecting the incoming/outging cables including cable glands , SMC coated coated clamps, nuts and bolts etc. all as directed and fixed to existing poles with mild steel flat of size 25mm x 4mm. Make: Sintex Cat Part No. GSTB 2520 or eqivalant in other approved makes
LED street luminaries, 70/72 watt, powder coated pressure die cast aluminium housing with weather proof gasket of lamp and driver compartment with 120 degree view angle, lumen output > 100 Lum/watt, lumen maintenance > 70% at 50000 hours, colour temp 5000-6500K, CRI > 70, THD < 15%, PF > 0.95 and LM 80 test complaince. The driver must be inteated APFC circuit protection, reverse polarity protection against 5KV high and comply with IEC:60598-1, IEC:61000-3-2, IEC:61547. The luminaire must have secondary optics with perfectly matched lens for better light control with and including brackets made of GI pipe of suitable dia light grade, bend to shape at an angle of 65120 degree not less than 1.2mtr long with 2 Nos. of M.S clamp fabricated out of MS flat of size 50 x 6 mm on pole, including nuts, bolts, washers etc and making electrical connections with 1.5sqmm sheathed copper conductor flexible wire of suitable length drawn into suitable size steel conduit with 03 Nos clamps from steet light to junction box, complete all as. specified and as directed.
Steel tubular swaged pole complete with base plate welded with pole, finial taper plug, bolt, nut and screws as specified type 410 SP-31 (9m long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with blak and white paint alternately on external surface above PCC benching including numbering with black paint and painting with bituminous paint internally complete and externally for portion embedded in PCC, complete all as specified and directed (PCC, earth work shall be measured & paid separately under respective items).
Electric motor siren, ideal audible range (diametrical) 3.25 Kms, Motor HP-0.50, RPM-8000, single phase, 220/240 volts AC, copper winding, aluminium casting body, double mounting, horizontal fitment, alongwith spring return push botton with element with box and fixed, complete including suitable size 3 core wire in steel conduit from siren to push button and fixing clamps, etc all as specified and as directed.
Thermometer having function of of wet bulb and dry bulb and fixed, complete all as directed.
Street light panel pole mounted outdoor type cubical panel suitable for maximum load of 6KW, 440 volts, 3 phase, 4 wire, 50 cycles per second comprising of incomming MCB TPN , 415 volts, 40 Amps-01 No, contactor TP 415 volts of rating 32 Amps-01 No, Digital timer 24 hours-01 No, toggle switch-01 No, complete all as specified and as directed. Make: Havells Cat part No. 1HXTS 03060 or equivalent of other approved makes.
Ciutting the existing MS/CI/GI pipe line upto 150mm bore by necessary welding or any other means and insertion of langed MS/CI Tee for new connection upto 50mm bore complete including excavation and earth work for branch connection from the existing MS/CI/GI pipeline. Note: The rate of new Tee is deemed to be included in the unit rate quoted by the tenderer.
Construction of valve pit (Brick masonry) of size 600mm x 600mm x 600mm internal dimension, complete, all as specified and as shown on drawing CEUZ/TD/1500/15.
LED tube light fitting flame proof type, CMRI certified, IP 65 protected, 2x16/20 watt including integral reflector made of aluminium alloy LM6 complete with all accessories prewired and including connecting up with three core flame proof copper conductor of suitable size, complete all as specified and as directed.
Point wiring using approved colour coding as per IS with Zerohologen Flame Retardant (HFFR) smoke free non corrosive, non toxic with insulated and unsheathed multistrand copper conductor single core cable, 1100V grade of size 2.5sqmm drawing into and including concealed ERW stove enamelled steel conduit not less than 25 mm dia ISI marked including flame proof bends and flame proof connecting pipes from flame proof junction box to flame proof light fittings for flame proof light points controlled by one switch including provision of 2.5 sqmm FRLS insulated multistranded copper conductor single core as earth wire to common earth and connecting to common earth dolly, complete, all as specified and as directed. Notes: 1. All flame proof switches and DBs shall be installed outside the Igloo. 2. The rate is inclusive of casting steel conduit and junction boxes/sunken boxes & DB while casting of RCC walls & slabs etc.
Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as directed.
Earthing complete with galvanized steel earth plate electrode 600x600x6mm burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 15mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15 type B1 in pit with angle iron (25x25x3)mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12mm dia MS fabricated handle, test point etc. in and including light grade GI protection pipe 20mm bore up to 7.5m length for drawing in earth lead wire, all as shown in electric plate No. 3 of SSR Part-I complete with necessary earth work in any type of soil, removal of soil to a distance not exc. 50m, testing on completion complete all as specified and directed .
Earthing complete with galvanized steel earth plate electrode 600x600x6mm burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 40mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15 type B1 in pit with angle iron (25x25x3)mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12mm dia MS fabricated handle, test point etc. in and including light grade GI protection pipe 40mm bore up to 7.5m length for drawing in earth lead wire, all as shown in electric plate No. 3 of SSR Part-I complete with necessary earth work in any type of soil, removal of soil to a distance not exc. 50m, testing on completion complete all as specified & directed .
Earthing complete with copper earth plate electrode 600x600x3.15mm buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with copper strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 40mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15 type B1 in pit with angle iron (25x25x3)mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12mm dia MS fabricated handle, test point etc. in and including light grade GI protection pipe 40mm bore up to 7.5m length for drawing in earth lead wire, all as shown in electric plate No. 3 of SSR Part-I complete with necessary earth work in any type of soil, removal to a distance not exc. 50m, testing on completion complete all as specified & directed .
100mm thick (compacted thickness) dry lean concrete (DLC) Desigh Mix (M-15) in single layer with 7 days compressive strength as 10 N/Sqmm with minimum cement (OPC) content 250 Kg / Cum of concrete with necessary joints as per MORTH specification all as per IRC:SP-49-1998 including form work if required and spread rolled and formed or consolidated to required gradient, camber using mechanical paver and tendem vibratory 8 to 10 tonne power roller complete to achieve desired density and strength complete all as specified and directed. Note:- In the event of increase in cement content as per design mix formula, nothing extra shall be admissible and quoted rates are deemed to include for the same.
125 micron transparent high density polyethyhlene (HDPE) film sheet Grade 1 conforming to IS-10889 laid over and including 25mm thick sand cushioning complete all as specified and directed. Note:- (i) Side lap of 150mm and end lap of 300mm shall be provided wherever required. The rate quoted \ shall be deemed included for the laps. (ii) Clear area only shall be considered for payment purpose and nothing extra shall be allowed for laps.
M/s Sekinder Paul Sharma
Tarmac Road and Roof Builders Srinagar
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .