Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.5 LAccepted-AOC | L1 | Accepted-AOC l1 | |
| 2 | L2₹28.8 L+₹4.4 L (18.0%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹30.6 L+₹6.2 L (25.3%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹31.6 L+₹7.2 L (29.4%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹31.8 L+₹7.4 L (30.2%)Rejected-Finance B XXIII 56 A PREM NAGAR SAINGARGH PATHANKOT 145001 PUNJAB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
15 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SATWARI
GE SATWARI
REPAIR / MAINT OF LT NETWORK OF ELECTRIC SUPPLY AND ALLIED UNDER AGE E/M OF GE SATWARI
2024_MES_660423_1
GEJM-27/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE SATWARI
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE SATWARI
₹70,000
Yes
10 Sept 2024
18 Jun 2024
17 Jul 2024
18 Jun 2024
15 Jul 2024
2 Jul 2024
Amount
Note:- Please refer Appx 'A' of particular specification for the list of makes of BOQ items.
Re-laying of healthy cable of any size retrieved from srl item no 1 above after repair, making proper jointing and making connection using thimbles/lugs of suitable size as required at site all as directed and specified.
Taking out GI protection pipe from the pole /passing through road/existing trenches for reuse at site or for taking credit of pipe to be replaced with new one all as directed and specified.
Relaying full bricks retrieved from srl item no 2 above for cable protection all as specified and directed.
Excavation in trenches not exceeding 1.5m in width and not exceeding 1.5m in depth and getting out in any type of soil all as directed and specified.
Supply and spreading dry river sand in trenches for cushioning of cable 8 cm layer before laying the cable and 15cm thick layer after laying the cable. Note-Sand layer shall be paid for 18mm only after well pressed all as directed and specified.
Supply & laying dry bricks over cable as mechanical protection layed flat with width equal to length of brick with sub class 'B' bricks all as directed and specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm, all as directed and specified.
Removal of excavated surplus material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified.
Material and labour for fixing of LT cable end termination Kit indoor and outdoor type, 1.1 Kilo Volts of size 6 sq mm to 16 sq mm 4 core alongwith nuts/bolt/washers as per existing size complete all as specified and directed.
All as per ser item No 9 here in before but of 25 to 50 sq mm 3.5 / 4 core all as directed
All as per ser item No 9 here in before but of 70 sq mm to 120 sq mm, 3.5 core all as directed
All as per ser item No 9 here in before but of 150 sq mm to 185 sq mm , 3.5 core all as directed
All as per ser item No 9 here in before but of 240 sq mm to 400 sq mm 3.5 core all as directed
Taking out serviceable/unserviceable LT cable of aluminum copper conductor of any size 2/3/4 core from excavated trench/pole/over ground etc and retrieved material to store kept in safe custody for reuse at site or for taking credit of cable to be replaced with new one all as specified and directed. Excavation, sand and return filling will be paid separately.
Supply, laying for replacement of unserviciable underground LT cable 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium multistarended stranded conductor, Armoured confirming to IS - 7098 Part-I (1988) with latest ammendments of sizes 16 Sq mm 2 core Cable all as specified and directed.
Supply, laying for replacement of unserviciable underground LT cable 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium multistarended stranded conductor, Armoured confirming to IS-7098 Part-I (1988) with latest ammendments of sizes 16 Sq mm 4 core Cable all as specified and directed.
Supply, laying for replacement of unserviciable underground LT cable 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium multistarended stranded conductor, Armoured confirming to IS-7098 Part-I (1988) with latest ammendments of sizes of 25 Sqmm x 4 core all as specified and directed.
Supply, laying for replacement of unserviciable underground LT cable 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium multistarended stranded conductor, Armoured confirming to IS-7098 Part-I (1988) with latest ammendments of sizes of 35 Sqmm x 3.5 core all as specified and directed.
Supply, laying for replacement of unserviciable underground LT cable 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium multistarended stranded conductor, Armoured confirming to IS-7098 Part-I (1988) with latest ammendments of sizes of 50 Sqmm x 3.5 core all as specified and directed.
Supply, laying for replacement of unserviciable underground LT cable 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium multistarended stranded conductor, Armoured confirming to IS -7098 Part-I (1988) with latest ammendments of sizes of 70 Sqmm x 3.5 core all as specified and directed.
Supply, laying for replacement of unserviciable underground LT cable 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium multistarended stranded conductor, Armoured confirming to IS-7098 Part-I (1988) with latest ammendments of sizes of 150 Sqmm x 3.5 core all as specified and directed.
Supply, laying for replacement of unserviciable underground LT cable 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium multistarended stranded conductor, Armoured confirming to IS-7098 Part-I (1988) with latest ammendments of sizes of 120 Sqmm x 3.5 core all as specified and directed.
Supply, laying for replacement of unserviciable underground LT cable 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium multistarended stranded conductor, Armoured confirming to IS-7098 Part-I (1988) with latest ammendments of sizes of 185 Sqmm x 3.5 core all as specified and directed.
Supply, laying for replacement of unserviciable underground LT cable 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium multistarended stranded conductor, Armoured confirming to IS-7098 Part-I (1988) with latest ammendments of sizes of 240 Sqmm x 3.5 core all as specified and directed.
Supply and fixing in replacement of aluminium lugs of size 70 sq mm capacity all as directed by Engr In Charge.
Supply and fixing in replacement of aluminium lugs of size 95 sq mm capacity all as directed by Engr In Charge.
Supply and fixing in replacement of aluminium lugs of size 120 sq mm capacity all as directed by Engr In Charge.
Supply and fixing in replacement of aluminium lugs of size 150 sq mm capacity all as directed by Engr In Charge.
Supply and fixing in replacement of aluminium lugs of size 185 sq mm capacity all as directed by Engr In Charge.
Supply and fixing in replacement of aluminium lugs of size 240 sq mm capacity all as directed by Engr In Charge.
Supply and fixing in replacement of aluminium lugs of size 300 sq mm capacity all as directed by Engr In Charge.
Supply and fixing in replacement of aluminium lugs of size 630 sq mm capacity all as directed by Engr In Charge.
Supply and fixing in replacement of cable jointing kit Straight through Indoor/outdoor type, heat shrinkable type including all jointing material & accessories suitable for 1100 Volt grade aluminium conductor cables of size 70 sqmm to 120 Sqmm 3.5 core cables all as directed and specified.
All as per ser item No 33 here in before but suitable for 150 Sqmm and upto 185 Sqmm 3.5 core
All as per ser item No 33 here in before but suitable for 240 sq mm to 300 sq mm x 3.5 core
Supply and fixing in replacement of GI steel tubing light grade complete under Road, Path drain, fixed on walls etc of size 100mm bore.
All as per ser item No 36 here in before but size 80mm bore
All as per ser item No 36 here in before but size 40mm bore
Supply, laying for replacement of unserviciable underground LT cable 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium multistarended stranded conductor, Armoured confirming to IS-7098 Part-I (1988) with latest ammendments of sizes 630 sq mm , Single Core Cable all as specified and directed.
Material and labour for cutting of bituminous road / floor / culvert / PCC hard standing for laying of pipe / cables not exceeding 1.5 meter wide and not exceeding 1.5 meter deep including refilling / with material and , watering well ramming / compacting and making good with PCC 1;2;4,type B-1, 100 mm thick complete all as specified and directed.
M/S S K Electricals Regd
G R CONSTRUCTIONS
kailu construction co
SATISH AND CO
Harsh Electricals
M/S RAJ ENGINEERS
G M ENGINEERING SERVICES
VEE ESS ENGINEERS
M/S ZTECH
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .