Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.4 LAccepted-AOC WZ 143 A 7A S 4 43 GALI NO 2 OLD MAHAVIR NAGAR NEW DELHI 110018 | WEST DELHI | DELHI | 110018 | L1 | Accepted-AOC Being lowest and competitive | |
| 2 | L2₹54.1 L+₹6.4 L (13.5%)Rejected-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-AOC Neither lowest nor competitive | |
| 3 | L3₹58.1 L+₹10.4 L (21.7%)Rejected-AOC | L3 | Rejected-AOC Neither lowest nor competitive | |
| 4 | L4₹58.9 L+₹11.2 L (23.5%)Rejected-AOC | L4 | Rejected-AOC Neither lowest nor competitive | |
| 5 | L5₹61.1 L+₹13.4 L (28.0%)Rejected-AOC C 9 53 IIND FLOOR SECTOR 08 ROHINI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | L5 | Rejected-AOC Neither lowest nor competitive |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
30 Jan 2021, 6:00 pmClosed
GE (Central) Delhi Cantt
GE (Central) Delhi Cantt
CLEANING AND REPAIR OF SEWAGE LINES AND MANHOLES IN DK-I AND DK-II RR COLONY IN THE AREA OF AGE B/R-I AND REPAIR TO ELECTRICAL APPLIANCES SUCH AS CEILING FAN,EXHAUST FAN GEYSERS INCLUDING CERTAIN MISC E/M WORKS UNDER GE
2021_MES_409747_1
GE/C-74/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE (Central) Delhi Cantt
As per NIT
9 documents required · 9 mandatory
₹500
GE (Central) Delhi Cantt
₹98,000
Yes
6 Mar 2021
5 Jan 2021
2 Feb 2021
5 Jan 2021
30 Jan 2021
18 Jan 2021
5 Jan 2021 - 18 Jan 2021
Amount
Taking down Cement plaster on brick walls built in cement mortar including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed. Engr-in-Charge .
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specially provided for complete all as specified and as directed. Engr-in-Charge .
Demolition of brick work built in cement mortar incl all quoins, arches, pillars etc complete all as specified and as directed.Engr-in-Charge .
M&L for cement concrete 1:2:4 type B-I, using 20 mm graded stone aggregate as in coping and similar work incl necessary form work to obtain a smooth finishes complete all as specified and as directed. Engr-in-Charge .
M&L for brick work with sub class 'B' brick using old size bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and as directed. Engr-in-Charge .
Excavation in any type of soil in trenches n exc 1.5m wide and n exc 1.50m in depth for foundation etc and getting out in in hard dense soil complete all as specified and as directed. Engr-in-Charge .
All as per item No 06 here-in-before but exc 1.50m and n exc 3.00m in depth complete all as specified and as directed. Engr-in-Charge ..
Returning filling in, incl spreading levelling watering and well ramming in layers n exc 25cm (after the pipes have been laid and tested) in soft/loose soil complete all as specified and as directed. Engr-in-Charge .
Removing excavated material not exceeding 50M and depositing where directed at a lavel not exceeding 1.5m above the starting point, soil complete all as specified and as directed. Engr-in-Charge .
M&L PCC 1:4:8 type D2 using 40mm graded stone aggregates as in foundation of manholes complete all as specified and as directed. Engr-in-Charge .
M&L for PCC 1:2:4 type B1 using 20mm graded aggregates as in surfaces channels and drains complete all as specified and as directed. Engr-in-Charge .
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement incl forms, moulds, mitred/stoped ends etc complete all as specified and as directed. Engr-in-Charge .
M&L for cement concrete 1:4:8 type D-2 using 40mm graded stone aggregates incl packing under and haunching against the sides for 150mm internal dia SGSW pipes after they are laid and tested including demolition of old bed and pipes complete all as specified and as directed. Engr-in-Charge . (thickness of concrete bed 100mm).
All as per ser item No 13 here-in-before but for 200mm internal dia Salt glazed stoneware pipes (thickness of concrete bed 150mm) complete all as specified and as directed. Engr-in-Charge ..
Supply and laying, jointing 150mm internal dia of salt glazed stoneware pipes grade 'A' incl testing and laid in trenches to a level on concrete bed complete all as specified and as directed. Engr-in-Charge .
All as per item No.15 here-in-before but 200mm internal dia of salt glazed stoneware pipes grade 'A' complete all as specified and as directed. Engr-in-Charge .
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 mixed with water proofing compound finished even and smooth without using extra cement complete all as specified and as directed. Engr-in-Charge .. (Water proofing compound shall be measure and paid separatelly).
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement complete all as specified and as directed. Engr-in-Charge .
Supply only intergral water proofing complete all as specified and as directed. Engr-in-Charge .
Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 or 3/4 section ) in cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate finished smooth and reforming benching as required for 150/200mm dia pipes complete all as specified and as directed.
S & F for precast fibre reinforced cement concrete Manhole cover (Ist quality) including grove and hook arrangement for lifting and placing in position and sides covered by MS sheet medium duty of overall Size 1000mmx500mmx80mm complete all as specified and as directed. Make : M/s Polycrete or equivalent make as approved.
S & F for precast plastic fibre reinforced cement concrete Manhole covers with frame medium duty of overall size 450mmx450mmx50mm factory made (make-polycrete) all as specified and directed by Engineer-in-Charge. Make : M/s Polycrete or equivalent make as approved.
Cleaning of EWCs, IWCs, bottle traps, Nahani Traps, Gully traps and Floor traps etc and CI/PVC Pipes all types top to bottom including junctions etc, Cleaning of sewage line upto GT in the area of DK-II,DK I Ring Road Colony , (Md accn and all types of Accn including multistory bldg ). ccomplete all as specified and as directed.
Cleaning of GTs in the area of DK-II, Ring Road Colony , (Md accn and all types of Accn) complete all as specified and as directed.
Cleaning of Manhole depth of 1.2mtr and any size of MH in the area of DK- II, Ring Road Colony ,(Md accn and all types of Accn) and taking out sludge and depositing them to notified area by Municipal Corp of Delhi for dumping or out side defence land complete all as specified and as directed.
Cleaning of Manhole depth exc 1.2 mtr and above of any size of MH in the area of DK-II, Ring Road Colony , (Md accn and all types of Accn) complete all as specified and as directed by Engineer-in-Charge.
Cleaning of Sewage line from GT to Ist Manhole in the area of DK-II, Ring Road Colony , (Md accn and all types of Accn) complete all as specified and as directed. Note-cleaning of sewage line daimeter upto 100mm to 150mm complete all as specified and as directed by Engineer-in-Charge.
Cleaning of sewage line n.exc 10mtr in length in the area of DK-II, Ring Road Colony (Md accn and all types of Accn). ccomplete all as specified and as directed. Note-cleaning of sewage line daimeter upto 100mm to 200mm complete all as specified and as directed by Engineer-in-Charge.
Cleaning of Sewage line 0.00mtr to 20.00mtr in length in the area of DK-II, Ring Road Colony (Md accn and all types of Accn) complete all as specified and as directed. (Note :- This item will be measured if length exceed from 10.00mtr.and cleaning of sewage line daimeter upto 100mm to 200mm complete all as specified and as directed by Engineer-in-Charge.
Cleaning of Sewage line 0.00mtr to 30.00mtr in length in the area of DK-II, Ring Road COlony (Md accn and all types of Accn) ccomplete all as directed and as specified. Note :- This item will be measured if length exceed from 20.00mtr.and cleaning of sewage line daimeter upto 100mm to 200mm complete all as specified and as directed by Engineer-in-Charge.
Cleaning of Sewage line 0.00mtr to 50.00mtr and onwards in length in the area of DK-II, Ring Road Colony , (Md accn and all types of Accn) ccomplete all as directed and as specified. (Note :- This item will be measured if length exceed from 30.00mtr.and cleaning of sewage line daimeter upto 100mm to 200mm complete all as specified and as directed by Engineer-in-Charge.
Dewatering/desludging of septic tanks, soakage wells etc of any depth, cleaning of all sludge, silt residue of both organic and inorganic nature by manual labour or by mechanical scrappers etc and disposal off the same out side the defence area notified by Municipal Corporation of Delhi all as directed by Engr-in-Charge.
Mechanically used water fitting Hydraulic pressure machine and water sucking hydraulic pressure machine jet press for cleaning of sewage line shall be used by the contractor as per direction of Engineer-in-Charge as on required basis. Job shall be completed to the entire satisfaction of GE. (For Dhaula Kuan Part -II ) complete all as specified and as directed by Engineer-in-Charge. .
All as per item No. 34 above but in the area of DK I complete all as specified and as directed by Engineer-in-Charge.
All as per item No. 34 above but in the area of RRColony complete all as specified and as directed by Engineer-in-Charge. .
S&F in repair 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with clamps etc including taking out/dismentling of old pipe ccomplete all as specified.
All as per item No. 39 above but bore of pipe in 110 mm complete all as specified and as directed by Engineer-in-Charge. .
S&F inrepair PVC (SWR) bends any radius bore 75 mm complete all as specified and as directed by Engineer-in-Charge.
All as per item No. 41 above but bore of pipe in 110 mm complete all as specified and as directed by Engineer-in-Charge. .
Supply and fix in replacement of broken cast iron (sand cast) soil, waste and vent pipes in any length, with or without ears, with cement joints, laid in trenches including excavation and PCC bedding and haunching in below ground level or in floors or fixed to walls with clamps etc, bore of pipe 75mm complete all as specified and as directed by Engineer-in-Charge. Make : NECO (Jayaswal)/HEPCO (Binay Udyog)/Jindal Saw/Hindustan Engineering products.
Supply and fix in replacement of broken cast iron (sand cast) soil, waste and vent pipes in any length, with or without ears, with cement joints, laid in trenches including excavation and PCC bedding and haunching in below ground level or in floors or fixed to walls with clamps etc, bore of pipe 100mm complete all as specified and as directed by Engineer-in-Charge. . Make : NECO (Jayaswal)/HEPCO (Binay Udyog)/Jindal Saw/Hindustan Engineering products.
Supply and fix cast iron Bends (sand cast) (any radius), diminishing pieces or tapers soil/waste pipes 75mm in any length (larger bore measured) complete all as specified and as directed by Engineer-in-Charge.
All as per item No.45 above but 100mm dia complete all as specified and as directed by Engineer-in-Charge.
S & F for precast fibre reinforced cement concrete Manhole cover (Ist quality) including grove and hook arrangement for lifting and placing in position and sides covered by MS sheet medium duty of overall Size 900mmx900mmx80mm complete all as specified and as directed by Engineer-in-Charge.
Dismantling/ demolition posts or struts embedded in soil or concrete etc (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground complete all as specified and as directed by Engineer-in-Charge.
Dismantling fencing wiremesh, any type complete all as specified and as directed by Engineer-in-Charge.
Excavation in post holes (or similar holes) n exc 0.5 cum getting out in any type of soil returning filling in and ramming earth or broken rubble mixed with earth around in layers n exc 25cm and covering and removal of surplus soil n exc 50m and making good surface complete all as specified and as directed by Engineer-in-Charge.
M&L for cement concrete Type C-2 (1:3:6) using stone (40mm graded aggregate) as in walls or retaining walls, any thickness, size or shape including pillasters, butresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and as directed by Engineer-in-Charge.
S&F mild steel angle /tee section etc in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc; flat iron fillets (for securing wiremesh etc) including all necessary drilling, bolting or riveting, etc including embeding in concrete and similar work conforming to Fe-290 Gde-E-165 ccomplete all as specified & directed by Engr-in-Charge.
S&F chain link M S Galvanised fencing mild steel galvanised fencing ccomplete all as specified & directed by Engr-in-Charge.
S&F mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips ccomplete all as specified & directed by Engr-in-Charge.
S&F 12mm mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut n exc 5cm long ccomplete all as specified & directed by Engr-in-Charge.
S&F framed work such as grills framed guard bars etc with ends of bars shouldered and or rivette or forged into spikes and similar work conforming to Fe 410.0 or Fe 310.0 including dismentallying of old u/s grill/frams ccomplete all as specified & directed by Engr-in-Charge.
S&F Framed work as in doors or gates of angle or other section with gusset plates,rails,braces,etc,ccomplete,drilled for fixing of steel sheeting or other covering,doors,etc.to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging,and also fastening and fixing including dismentallying of old u/s doors/gates complete all as specified & directed by Engr-in-Charge.
S&F in repair galvanized 2 strand steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75 mm spacing and straning and fixing to fencing post with staple or steel pins etc complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of new or previously untreated steel surfaces over 10cm in width or girth and applying two coats of syanthetic anamel paint over one coat of red oxide ccomplete all as specified & directed by Engr-in-Charge.
M&L preparation of new untreated STEEL surfaces of any description, n exc 10cm in width and applying two coats of synthetic enameled paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-Charge.
M&L for providing 50 mm thick cement concrete 1:3:6 type C2 (40 mm graded aggregate) as in subbase complete all as specified and as directed by Engineer-in-Charge.
M&L for providing 100 mm thick cement concrete 1:2:4 type B1 (20 mm graded aggregate) laid in alternate bays as in hard standing broom finished complete all as specified & directed by Engr-in-Charge.
Forming contraction (Dummy) Joints 65mm deepx10mm wide filled with sealing compound Grade 'A' ccomplete all as specified & directed by Engr-in-Charge.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade including 25 mm thick sand cusion ccomplete all as specified & directed by Engr-in-Charge.
M&L 15mm thick screed bed or bedding layer for laying floor in CM 1:6 ccomplete all as specified & directed by Engr-in-Charge.
S&F Chequered cement concrete tiles 25cm X 25cm x 25mm thick set, jointed and pointed in neat cement slurry in floors with grey cement and pigments ccomplete all as specified & directed by Engr-in-Charge.
All as per item No 05 here in before except brick work complete all as specified and as directed by Engineer-in-Charge.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors or fixed on walls 110mm dia fixed in repairs complete all as specified and as directed by Engineer-in-Charge.
M&L flush pointing to block in course or ashlar masonry or concrete block walling in CM 1:4 complete all as specified and as directed by Engineer-in-Charge.
M&L for mild steel TMT bars 10mm dia and over as in stirrups and spacers, binders, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge.
Refixing of Ceiling fan / exhaust fan/ fresh air/ Wall mounted fan including taking down after necessary repairs/ replacement of unserviceable/ wornout part and testing the same as per entire satisfaction of Engr-in- Charge complete all as specified and directed.
Taking down carefully geysers 25/35/50 ltrs capacity opening for inspection reassembling and re-fixing in position after carrying out repairs rates included for replacement of pressed rubber gasket nuts, bolts etc complete all as specified and as directed by Engineer-in-Charge. Note- Spare Parts such as tank, apparatus plate, outer body shall be measured and paid separately under relevant item of supply only.
Taking down carefully old unserviceable heating element, thermostat, connection pipe, from geyger of any storage capacity and make complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully old unserviceable sheet metal enclosure of any capacity and make complete all as specified and directed.
M&L for opening up the winding of ceiling fan 1200 mm sweep any make and type and rewinding with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete. Taking down and testing of the ceiling fan after refixing in position to the entire satisfaction of Engr-in-Charge.
All as above but 1400mm sweep complete. Taking down and testing of the ceiling fan after refixing in position to the entire satisfaction of Engr-in-Charge.
M&L for opening up the winding of Exhaust fan 225/300 mm sweep any make and type and rewinding with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete. Taking down and testing of the exhaust fan after refixing in position to the entire satisfaction of Engr-in-Charge.
All as above but 450mm sweep complete. Taking down and testing of the exhaust fan after refixing in position to the entire satisfaction of Engr-in-Charge.
M&L for opening up the winding of wall mounted fan 250/300 mm sweep any make and type and rewinding with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete. Taking down and testing of the wall mounted fan after refixing in position to the entire satisfaction of Engr-in-Charge.
S&F Ceiling fan blade suitable for 1200mm sweep of any make with suitable size as per site requirement complete all as specified and directed.(As per sample)
S&F Ceiling fan blade suitable for 1400mm sweep of any make with suitable size as per site requirement complete all as specified and directed.(As per sample)
S&F exhaust fan Metal blade suitable for 225/300mm sweep of any make with suitable size of split pin as per site requirement complete all as specified and directed.(As per sample)
All as above but 450mm sweep complete all as specified and directed.(As per sample)
S&F PVC canopy upper and lower of celing fan of any make & size complete with nuts, bolts & washers as per sample approved (As per sample).
Taking down old unserviceable down rod and supply and fix 1.5 mtr long down rod duly made out off Mild steel including taking down & refixing of existing ceiling fan of any sweep and make and making connection from ceiling rose to PVC connector complete all as specified and directed.
S&F ceiling fan down rod 0.6 mtr long duly made out off mild steel including rubber bush nut, bolt, washer and split pin complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement capacitor of 1.0 MFD, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement capacitor of 2.5 MFD, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement capacitor 3.15 MFD complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement capacitor 4.0 MFD complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement capacitor 6.0 MFD complete all as specified and as directed by Engineer-in-Charge.
Supply only ball bearing No. 6202, complete all as specified and as directed by Engineer-in-Charge.
Supply only ball bearing No. 6203, complete all as specified and as directed by Engineer-in-Charge.
Supply only gun metal bush of any size and make sutiable for ceiling fans 1200/1400 mm compete all as specified and directed.
Supply only worn out shaft, beyond economical repair of existing ceiling fan any make, type or size as per original one ceiling/exhaust fan complete all as directed.
S&F PVC fresh air fan blade suitable for 250/200 mm size with all fixing accessories complete all as spd and directed.
M & L for painting of ceiling fans , in situ with synthetic enamel paint by spraying including filling cavities with filler, one or more coat to achieve even and smooth surface after cleaning all dust etc.and endorsement of fan no.with black synthetic enamel paint complete all as directed.
M & L for painting of exhaust fans complete, in situ with synthetic enemel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as spd and directed.
S&F in replacement PVC cable copper conductor multi strandrad flexible 23/.0076 twin core and making connections from ceiling rose to fan complete all as specified and as directed by Engineer-in-Charge.
S&F Fresh air fan motor of capacity 1/6 HP 230 volts, 50 Hz, AC supply suitable for 250/200 mm size Fresh air fan as per sample complete all as spd and directed.
Supply only exhaust fan motor capacity 1/4 HP 230 volts suitable for 230 mm size exhaust fan complete all as directed.
S&F fresh Air fan 250mm sweep with louvers including connecting with suitable size of copper conductor from ceiling rose to fan complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix fan regulator electronic type 5 steps connectingcomplete all as specified and as directed by Engineer-in-Charge.
Supply & fix Modular five stepped type electronic fan regulator 100W,2 module 360 degree rotatable type 230V AC complete all as specified and directed by Engineer in charge.
M & L non return valve 15mm dia (ISI Marked) for Geysers of 50/35/25 Ltr capacity including GI Socket,Nipple, elbow ,bend etc and connecting up complete all as directed.
M&L for fixing in replacement safety pressure valve of size 15 mm dia, ISI marked for geysers complete all as directed by Engineer-in-charge.
M & L chromium plated copper connection pipe 18" long with two brass adopters and connecting up complete all as specified and as directed by Engineer-in-Charge.
M & L chromium plated copper connection pipe 24" long with two brass adopters and connecting up complete all as directed.
S&F SS braided pipe of 12 mm (internal) suitable for hot/cold water, 450 mm long with brass nuts and rubber washers complete all as specified and as directed by Engineer-in-Charge.
S&F heating element of 2 KW triangular type with nut bolt washer complete all as specified and as directed by Engineer-in-Charge.
S&F heating element of 2 KW circular type with nut bolt washer complete all as specified and as directed by Engineer-in-Charge.
S&F heating element of 1.5 KW triangular type with nut bolt washer complete all as specified and as directed by Engineer-in-Charge.
S&F of thermostat for 25/35/50 ltrs capacity of geysers complete all as specified and as directed by Engineer-in-Charge.
M & L neon lamp/indicator lamp for geysers complete all as specified and as directed by Engineer-in-Charge.
M&L plug top, 3 pin, 10/20 amp earth metal clad (ISI marked) complete all as specified and as directed by Engineer-in-Charge.
S&F socket 3 pin 10/20 amp earth metal clad (ISI marked) complete all as specified and as directed by Engineer-in-Charge.
M&L for soldering and brazing inner copper tank 50/25/35 ltrs with brass solder and refixing complete (taking down and fixing shall be paid under item No 3 above)
Supply only base plate assembly (confirming to ISI ) complete for 25/35 Ltrs capacity copper tank geyser including inlet, outlet and thermostat pipe with drain plug and screws for fixing the element inclusive of clamps for holding the elements with nut, bolts & air release valve suitable for any type/make of geysers installed at site complete all as specified and as directed by Engineer-in-Charge.
Supply only inner Steel tank for geysers of capacity 50 ltr as per existing of approved make complete all as specified and as directed by Engineer-in-Charge.
Supply only inner Steel tank for geysers of capacity 25/35 ltr as per existing of approved make complete all as specified and as directed by Engineer-in-Charge.
Supply only outer body/cover suitable for 25 ltr cap geyser made out of mild steel pre-treated and stove enamelled sheet of 18 SWG complete with top and bottom cover, rubber gasket, stead screw for fixing the top and bottom cover to outer body including two coat of white synthetic enamel paint over one coat of red oxide (spray painting) all asdirected by Engineer-in-charge.
Supply only top cover for geysers (confirming to IS) suitable for any makes/capacity/type of geysers installed at site duly painted (spray) in two coats with enameled (Deco) paint of colour & shade as directed.
Supply only bottom cover for geysers (Confirming to IS) suitable for any make/capacity/type of geysers installed at site duly painted (spray) in two coats with enameled (Deco) paint of colour & shade as directed complete with inspection plate in two pieces complete all as specified and as directed by Engineer-in-Charge. .
M & L in replacement fastner 100mm long & 6mm dia long with suitable size of nut for fixing geyser/Exhaust Fan complete all as specified and as directed by Engineer-in-Charge.
M&L copper cable flexible 3 core PVC insulated of size 40/.0076 complete all as specified and as directed by Engineer-in-Charge.
S & F sheet metal enclosure with 2 pin and earth plug and socket complete with and including MCB 10 Amps 240 volts heavy duty. complete all as specified and as directed by Engineer-in-Charge.
S & F sheet metal enclosure with 2 pin and earth plug and socket complete with and including MCB 20 Amps 240 volts heavy duty complete all as specified and as directed by Engineer-in-Charge.
Supply and fix heating element suitable for solar water heater of capacity 3KW/4 KW single phase, 2 wire complete all as specified and as directed by Engineer-in-Charge. .
S&F factory made epoxy powder coated Distribution Board TPN 4 ways (TPN MCCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN MCCB 125/160 Amp as incomer and 12 SP or 4 No TP MCBs as outgoing complete all as specified and conforming to IS : 8623. complete all as specified and as directed by Engineer-in-Charge.
S&F factory made epoxy powder coated Distribution Board SPN-12 ways (SPN MCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp rated copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one SPN- MCB 25/40 Amp as incomer and 10 SP MCBs outgoing complete all as specified and conforming to IS : 8623.
S&F factory made epoxy powder coated Distribution Board SPN-8 ways (SPN MCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp rated copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one SPN- MCB 25/40 Amp as incomer and 10 SP MCBs outgoing complete all as specified and conforming to IS : 8623. Make : Legrand/ ABB/Siemens.
Supply & Fix MCCB 160 Amp, 16 KA, 415 Volts 4 pole with copper lugs complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix MCCB 125 Amp,16 KA, 415 Volts 4 pole with copper lugs complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix MCCB 100 Amp,16 KA, 415 Volts 4 pole with copper lugs complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix MCCB 63 Amp,16 KA, 415 Volts 4 pole with copper lugs complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix MCCB 250 Amp, 16 KA, 415 Volts 4 pole with copper lugs complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix MCB SPN 32- 63 Amps, 240 Volts, 10 KA capacity C' curve complete all as specified and as directed by Engineer-in-Charge.
S&F MCB SP 6-32 Amps 240 volts curve 'C' series 10 KA 50 HZ complete all as specified and as directed by Engineer-in-Charge.
Note :- Total amount of Sch of credit is Rs. 127392.00 as per Sch of credit. Net contract sum shall be total quoted amount of bidder (-) amount of Sch of credit.
M/S ANIL KUMAR
AMIT ASSOCIATES
JIWAN DASS THAREJA AND SONS
L G BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .