| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.5 LAccepted-AOC HOUSE NO 29 A SIJUBARI NIZARA PATH PO PS HATTIGAON GUWAHATI 38 | KAMRUP METRO | ASSAM | 781038 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹35.6 L+₹1.9 L (5.80%)Rejected-Finance GOSWAMI COLONY PO UDAYAN VIHAR DISTT KAMRUP ASSAM 781171 | KAMRUP METRO | ASSAM | 781171 | L2 | Rejected-Finance Not Validated (Other than lowest bidder) | |
| 3 | Rejected-Technical HOUSE NO 129 BASISTHA ROAD BASISTHA CHARIALI PO BASISTHA GUWAHATI 781029 ASSAM | KAMRUP METRO | ASSAM | 781029 | - | Rejected-Technical Not Admitted |
Tender Value
Refer Docs
EMD Value
₹63,860
Closing Date
2 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE GUWAHATI
GE GUWAHATI, PO SATGAON, DISTT KAMRUP - 781027
ADDN ALTN TO BURN CENTRE AND EXTENSION OF WAITING AREA FOR PATIENTS RELATIVES AT ICU OF BASE HOSP UNDER GE GUWAHATI
2022_MES_530844_5
GE/GUW/11/8215 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
GUWAHATI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE GUWAHATI
₹63,860
Yes
11 Feb 2023
30 Nov 2022
4 Jan 2023
30 Nov 2022
2 Jan 2023
14 Dec 2022
30 Nov 2022 - 7 Dec 2022
Amount
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.complete all as directed
Taking down Chowkhats or frames exc 1.5 sqm and not 4.00 sq. m each but with shutters (without taking off shutters from the frames) complete all as directed.
Taking down Chowkhats or frames not exc. 1.5 sq. m each but with shutters (without taking off shutters from the frames) complete all as directed.
Demolition Cement Concrete (unreinforced)in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as directed.
Dismantling floor floor hearth or wall tiling including cement mortar bedding but not backing and removing debrires from the site complete all as directed.
M&L for 15mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work in two layers (10mm & 5mm) mixed with and including liquid water proofing compound in top layer as per manufacturer's instructions, finishing the surface even and fair without using extra cement complete all as specified and as directed.
M&L for rendering cement plaster 15mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished even and fair complete all as specified and directed.
M&L Rendering 5 mm thick on concrete surfaces as in ceiling in cement mortar 1:3 for finished even and fair complete all as specified and as directed.
S&F 140mm (Overall length of cover plate) Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing as specified in SSR Part I, Section 8 complete all as specified and as directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing as specified in SSR Part I, Section 8 complete all as specified and as directed.
S&F Colour coated (minimum thickness of powder coating 50 micron) Anodised aluminium frame for doors, windows, ventilators, partitions with one or more rebates including joining cleat for fixing etc. complete all as specified and directed Note:- Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed
S&F Colour coated (minimum thickness of powder coating 50 micron) anodised aluminium doors shutters including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, along with standard locking arrangements, handles, tower bolts etc as required. complete all as specified and directed Note:-(i) Labour charges for fixing of glass/wire guage is inclusive in the unit rate quoted. Glass/Wire Guage/locks shall be measured and paid seperately at supply only rates (ii) Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed
S&F Colour coated (minimum thickness of powder coating 50 micron) anodised aluminium windows/ventilators/partitions any type including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, along with standard locking arrangements, handles, tower bolts etc as required. complete all as specified and directed Note:- (i) Labour charges for fixing of glass/wire guage/aluminum grills is inclusive in the unit rate quoted. Glass/Wire Guage/aluminum grills shall be measured and paid seperately at supply only rates (ii) Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed
Supply only 5.5mm thick plain sheet glass, ordinary quality fixed with Aluminum frame work exc 0.5 sqm in each pane complete all as specified and as directed.
Supply only 4mm thick plain sheet glass, ordinary quality fixed with Aluminum frame work n. exc 0.5 sqm in each pane complete all as specified and as directed.
Supply only 4 lever, Mortice lock, vertical type, size 100 mm complete all as specified
Supply only Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminum window/ventilator shutters complete all as specified and as directed.
S&F Aluminum (extruded body)Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified.
S&F 5mm thick plain colour PVC sheet in strips & channel feathered at the edges for fixing on Solid PVC Wall Lining, Insulated PVC Wall Lining, and Solid PVC Partitions inclusive of Solvent Cement and fixing at site. complete all as specified and directed.
M&L 25mm thick Cement concrete type B0, (1:2:4) (using 12.5mm graded stone aggregate) as in sub base of flooring for layind floor finishes complete all as specified and as directed.
M&L 75mm thick cement concrete (1:3:6) type C-2( using 40mm graded crushed stone aggregate) as in plinth protection laid in alternate bays (not exceeding 2 Sqm each) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and as directed.
M&L Virified Ceramic tiles dark shade, double charged shade 9-10 mm thick (square/rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including cement screed 15 mm thick 1:6 complete all as specified and as directed.
M&L Non skid coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tiles exc.11 sqm but not exc 0.18 sqm in floor etc set and jointed in neat cement slury over and including cement screed 15 mm thick 1:6 complete all as specified and as directed.
M&L for Coloured glazed ceramic tiles 600 X 300 x 9-10mm thick in vertical surfaces and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick backing with CM (1:4) complete all as specified and as directed.
S&F framed work such as grills, grating, etc, with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars, barred iron doors, ladders; framed baluster; walk ways, railings, framework of water tanks and similar work conforming to Fe 290 Gde E-165 including necessary preperation of surfaces and applying one shop coat of red oxide, zinc chrome primer complete all as specified and as directed.
S&F in repair , aluminum anodised Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed
S&F in repairs,15mm bore PVC Connection with PTMT nut of length 450 mm complete all as specified and directed
S&F in repairs, 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed
S&F in repairs, 75mm UPVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/Ceilings complete all as specified and as directed.
S&F in repairs, 110mm UPVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/Ceilings complete all as specified and as directed.
S&F 15mm bore GI pipe medium grade water tube with all fittings laid in floors fixed to walls and ceilings or laid in floors, including necessary taking down of exsisting old pipe complete all as specified and as directed.
S&F 20mm bore GI pipe medium grade water tube with all fittings laid in floors fixed to walls and ceilings or laid in floors, including necessary taking down of exsisting old pipe complete all as specified and as directed.
S&F in repair, single piece-WC with PP soft close seat cover , Hinges, Fixing accessories set and accessories set, Cistern fitting, Size:360x640x685mm,S tram-110mm all as specified and as directed Make-JAQUAR CAT No-SLS-WHT-6851S or equivalent as approved by GE from list of approved makes.
S&F in repair, Wall mixer 3-in-1 system with provision fot both hand shower and over head shower complete with 115mm long bend pipe, connection legs, wall flange (without hand and overhead shower) complete all as specified and as directed Make-JAQUAR CAT No-SOL-6281 or equivalent as approved by GE from list of approved makes.
S&F in repair, Hand shower 32mm round shape straight design dual flow (ABS Body and face plate chrome plated) with rubit cleaning system with easy flexible tube in chrome finish 1.5 meter long with nuts complete all as specified and as directed Make-JAQUAR CAT No-HSH-5541 or equivalent as approved by GE from list of approved makes.
S&F in repair, Over head shower 200 x 200mm Square shape single flow ( Body & face plate stainless steel with chrome finish) with rubit cleaning system with 100mm long shower arm complete all as specified and as directed Make-JAQUAR CAT No-OHS-CHR-1619 or equivalent as approved by GE from list of approved makes.
S&F in repair, 15mm angular stop cock with wall flange all as specified and as directed make -JAQUAR CAT NO-FON-40053 or equivalent as approved by GE from list of approved makes.
S&F in repair, Table top wall hang basin with fixing accessories,size :425x345x175mm incl waste coupling Make-JAQUAR CAT No-CNS-WHT-903 or equivalent as approved by GE from list of approved makes.
S&F in repair, Bottle trap (with internal partition) 32mm size with 250mm & 190mm low wall connection pipes & wall flange all as specified and as directed Make-JAQUAR CAT No-ALD-769L250x190 or equivalent as approved by GE from list of approved makes.
S&F in repair, Two Way Bib Cock with Wall Flange Make - JAQUAR CAT No OPR-10041PM or equivalent as approved by GE from list of approved makes
S&F in repair, Hand shower (health faucet)(ABS Body) with 8mm dia, 1.2 meter long flexible tube & wall hook all as specified and as directed Make-JAQUAR CAT No-ALD-CHR-573 or equivalent as approved by GE from list of approved makes.
S&F in repair, toilet paper holder all as specified and as directed Make-JAQUAR CAT No-AKP-35751P or equivalent as approved by GE from list of approved makes.
S&F Reflection looking mirror of size 600x450mm fixed to wall with chromium plated brass screws and cup washers all as specified and as sdirected.Make PARRYWARE Cat no C 8611 or equivalent as approved by GE from list of approved makes.
M&L 18-20 mm thick Granite (of any type) work (table rubbed and polished) in floor, steps, jambs, soffits, pillars, window-cills and like in 20mm thick screed bed or bedding layer cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M&L complete removal of existing treatment surfaces of any description and apply two coats of plastic emulsion paint surfaces of any description over 10cm girth or width not otherwise described over one coat of primer complete all as specified and directed
M&L, Preparation of new surfaces of any description, over 10 cm in width or girth and applying two coats of plastic emulsion paint over a coat of primer including cement based wall care putty (minimum 1.5mm thick) complete all as specified and directed.
M&L Preparation of new surfaces of any description and applying 2 coats with Acrylic Smooth exterior paint of required shade (Two coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and as directed
M&L complete removal of existing treatment surfaces of any description and apply two coats 2 coats with Acrylic Smooth exterior paint of required shade (Two coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and as directed
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for column & wall foundation, UG Cable, Pipes etc and getting out in soft/loose soil complete all as specified and directed.
M&L cement concrete in foundation, filling mass concrete type-D2, 1:4:8, (using 40mm graded crushed stone aggregate) complete all as specified & as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n exc 25 cm layers in soft/loose soil complete all as specified and directed.
Removing excavated material (Soil) not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified and directed.
Use and waste of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, rough finished surfaces of concrete flat complete all as specified and directed.complete all as specified and directed.
Use and waste of Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. rough finished surfaces of concrete flat complete all as specified and directed.complete all as specified and directed.
Use and waste of Formwork to sides of pillars, posts, struts, piers, columns and stanchions rough finished surfaces of concrete square, rectangular or polygon complete all as specified and directed.
Use and waste of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough finished surfaces of concrete flat complete all as specified and directed.complete all as specified and directed.
M&L, Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L, Mild steel TMT bars, 5mm dia and over and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L RCC 1:2:4 type B1 (nominal mix) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed
M&L RCC 1:2:4 type B1 (nominal mix) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed
M&L RCC 1:2:4 type B1 (nominal mix) as in Columns, pillars, piers, posts and struts complete all as specified and directed
M&L RCC 1:2:4 type B1 (nominal mix) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed
M&L brick work with sub class 'B' bricks, old size bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
M&L hard core of broken stone or boulders, gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L 100mm thick cement concrete (1:3:6) type C-2(using 40mm graded crushed stone aggregate) as in floor/pavings and finished even and smooth without using extra cement complete all as specified and as directed.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 including necessary preperation of surfaces and applying one shop coat of red oxide, zinc chrome primer complete all as specified and as directed.
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as complete all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed..
M&L preparing new steel Surfaces of any description, not otherwise described,over 10cm width orgirth with applying two coats of synthetic enamel paint, complete all as specified and directed.
M&L water proofing treatment to RCC roof slab, including parapet comprising with the following course of treatment/specification from bottom to top (i) Cleaning of concrete surfaces of roof, picking sweeping cleaning the surface to remove all loose dust and thoroughly washing down with clean water and dried complete (ii) Rendering 10mm thick in CM (1:4) on existing roof surface true to level after applying cement slurry @ 3Kg/Sqm. (iii) Applying one coat of bituminous primer @ 0.40 Ltr/Sqm. (iv) Supply and laying 3mm thick APP based olymeric membrane of approved manufacturer with weight not less than 3.60 Kgs per Sqm, reinforced with non-woven polyester febric weight not less than 150gms per Sqm. Polymeric membrane shall be taken to a height as required at site/30cm(minimum) and than inserted inside the groove of parapet wall and shall be finished by a membrane flashing. (iv) One coat of Solar reflective bituminious Aluminium paint of approved brand to be provided over the APP membrane as per manufacturers instructions. Note : (a) Work shall be carried out through specialized applicator approvrd by GE. Contractor shall submit sufficent documents/Credentials in support of Applicator whom he wants the work excuted. (b) Laying APP based polymeric membrane shall be done torch on method as per manufactures instructions. (c) A minimum overlap of 100mm and 75mm should be made at the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as per manufacturers instruction.
S&F Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directed.
M&L Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) including connections to flushing pipe and outgoing pipes complete all as specified and directed.
S&F Front Insertion Type Gas Outlets for Oxygen gas system complete all as specified and as directed.
S&F Front Insertion Type Gas Outlets for Vaccum system complete all as specified and as directed.
S&F Oxygen Flowmeter of 15 IPM Capacity with humidifier Bottle complete all as specified and as directed.
S&F copper pipes of 12mm outer dia. and 0.7mm thick for oxygen and vacum gas system complete all as specified and as directed.
S&F Area Alarm System Microprocessor based audio visual type alarm for two gas complete all as specified and as directed
S&F Ward Vaccum Unit with Jar of 600 micapacity complete all as specified and as directed
S&F Low pressure antistatic tubes complete all as specified and as directed
S&F Probe for oxygen outlet compiable to ventlator Hose pressure antistatic tubes complete all as specified and as directed
S&F Isolation Ball Valves with Brass Adopter 12mm outer dia complete all as specified and as directed
Supply, install, testing & commissioning of hi wall, split-type Air Conditioner Unit of capacity 1.5 TR based on Inverter Technology comprising of indoor & outdoor units complete with cordless remote control unit & with in-built air ionizer & plasma filter for better indoor air quality with minimum 5 star rated including electric connections complete all as specified and as directed. NOTE : (i) The Air Conditioner shall be initial filled / charged with refrigerant of specified quantity & the refrigerant to be used shall of Non-CFC type & as per the latest technology. (ii) The cost of additional refrigerant pipes required (if any) is deemed to be included in the unit quoted rates. (iii) Suitable piping of adequate length & size 5/8" for drainage of condensate water from indoor unit shall be provided & the cost of the same is deemed to be included in the unit quoted rates. (iv) Anything missed out in the technical specifications but technically required for efficient working of the AC is deemed to be included in the unit quoted rates.
M&L concealed sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FR-LSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of suitable size with all fittings and accessories ISI marked including cutting chases and making good to walls, floors etc as per existing specifications, complete all as specified and as directed. NOTE : (i) Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED.
S&F Voltage Sablizer for automatic operation, single phase with neutral, air cooled indoor type and designed for input voltage variation between 170 Volts to 250 Volts with voltage stablizer at 230 Volts with accuracy + 2.5% and Capacity of 3 KVA complete all as specified and directed.
S&F sheet metal encloser Plug and socket for suitable for 20 Amps SPN with and including 20 Amps MCB and flush to wall surface complete all as specified and directed. .
S&F 25 Amps Single Phase motor starter, 240 Volts complete all as specified and directed.
Supply, laying and testing PVC insulated, under ground cable armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm, 4 core complete all as specified and directed.
M&L earthing with GI earth plate electrode 600x600x6mm thick buried directly in ground vertically to depth not less than 2.25m below the ground level with top edge of earth plate at a depth not less than 1.5m below the ground level connected to galvanized iron wire 4mm dia earth lead by means of bolts & nuts,check nuts & washers made of galvanised steel, earth wire protected by and including PCC (1:2:4) type B1 precast RCC cover slab (1:2:4) reinforced with 8mm dia TMT bars 100mm center to center bothways including one handle made of 10 mm dia round bar, including necessary excavation and earthwork in any type of soil, 20 mm dia medium grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 15 mm bore medium grade galvanized steel tubing for drawing earth wire GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete all as specified and as directed.
M.G. ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .