Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC | ₹10.4 L Quoted ₹10.8 L | L1 | Accepted-AOC L1 bidder Accepted |
| 2 | L2₹11.8 L+₹95,739 (8.85%)Rejected-AOC OPPOSITE J K BANK BAROO NH1 HAIDERY COMPLEX BAROO KARGIL BAROO KARGIL LADAKH 194103 | KARGIL | LADAKH | 194103 | ₹11.8 L+₹95,739 (8.85%) | L2 | Rejected-AOC L2 bidder |
| 3 | L3₹12.6 L+₹1.8 L (16.7%)Rejected-AOC ROOM NO 262 PART II NEAR SANKER MANDIR GANESH MURTHI NAGAR COLABA MUMBAI 05 | MUMBAI | ₹12.6 L+₹1.8 L (16.7%) | L3 | Rejected-AOC L3 bidder |
| 4 | L4₹12.7 L+₹1.9 L (17.6%)Rejected-AOC | ₹12.7 L+₹1.9 L (17.6%) | L4 | Rejected-AOC L4 bidder |
| 5 | L5₹13.1 L+₹2.3 L (21.6%)Rejected-AOC | ₹13.1 L+₹2.3 L (21.6%) | L5 | Rejected-AOC L5 bidder |
Tender Value
Refer Docs
EMD Value
₹32,000
Closing Date
25 Nov 2021, 6:00 pmClosed
GE PROJECT PANAGARH
GE PROJECT PANAGARH, PO- PANAGARH, DIST-BURDWAN
REPAIR / REPLACEMENT OF INTERNAL WIRING, FITTING, FIXTURE, CEILING FAN, EXHAUST FAN GEYSER AND CONNECTED MISC WORK AT NABAGRAM MIL STN UNDER GE PROJECT PANAGARH
2021_MES_484005_1
8110/E8
Open Tender
Civil Works
Item Rate
180 days
GE PROJECT PANAGARH
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE PROJECT PANAGARH
₹32,000
Yes
6 Dec 2021
27 Oct 2021
27 Nov 2021
27 Oct 2021
25 Nov 2021
11 Nov 2021
Amount
Taking down carefully aluminum/copper point wiring (light, fans, socket or power etc) complete including fixture and fittings such as switches ,ceiling rose, pendants, regulators, sockets , light fitting etc , removing materials to store for keeping in safe custody or for taking credit ( credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls ,floor, etc.
M & L for point wiring for one light /fan point with 1.5 sqmm cable PVC insulated copper conductor multi stranded as per IS-694 FRLS cable controlled by one way switch, drawn with PVC casing/caping with all accessorie and PVC Box of suitable size including 1.5 sqmm multi strand copper conductor cable (green colour) PVC insulated and unsheathed for earth continuity connected to common earth dolly for mounting of fittings such as switch, socket and speed regulator all as specified and directed.
For light/ceiling fan/exhaust fan point controlled by one switch
For 5 Amp switch socket point
All as per item no 2 here in before but for One 15 Amps switch socket point , independent, with cables 2.5 Sq mm of size
Supply and fixed switch socket combination 3 pin 5 A complete all as specified as directed.
Supply and fixed switch socket combination 3 pin 16 A complete all as specified as directed.
Supply and fixed ceiling rose 3 pole/PVC/polycarbonate isoloted body
Supply and fixed switch piano flush type single pole, one way 5 Amps
Supply and fixed stepped type electronic Fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and directed.
Supply and fixing 20A/10A, Switch Socket Combination with Box with Box 4 fixing Holes complete.
Supply and fixed in repairs Call bell ding dong type 230/240 volt AC complete all as specified and directed.
Supply and fixing in repair LED light fitting 20Watt with and including LED tube rod 4 feet long suitable for single phase 230V 50 Hz AC supply made with aluminum extrusion complete with all accessories internally prewired and including connecting up with three core flexible copper conductor cable of size 1.5sqmm( nominal area ) complete.
Supply and fixing in repair low depth recess mounted 2x2 LED made with single pieces CRCA sheet metal ,light in weight and comes with an aluminium extrusion frame, ceiling light full lit luminaire with glare free uniform illumination withlonger life and less maintenance.light fitting 36 Watt for single phase 230V 50 Hz AC supply complete with all accessories internally prewired and including connecting up with three core flexible copper conductor cable of size 1.5sqmm( nominal area ) complete.
Supply Fix in repair of 45 Watt LED well glass ( 110 Lumen/watt) CCT 5700 K circular light fitting roof mounted with excellent thermal management along with IP 65 protection complete all as directed.
Supply Fix in repair of 25 Watt LED bld security light ( 110 Lumen/watt) CCT 5700 K with excellent thermal management along with IP 65 protection complete all as directed.
Supply fix in repair 9 watt LED Lamp complete all as specified as directed.
Supply and fixed in repairs Modular white cover plate with frame 3 modules complete all as specified and directed.
Supply and fixed in repairs Modular white cover plate with frame 4 modules complete all as specified and directed.
Supply and fixed in repairs Modular white cover plate with frame 6 modules complete all as specified and directed.
Supply and fixed in repairs surface mounting plastic box 3 module 4X4 inch size complete all as specified and directed.
Supply and fixed in repairs surface mounting plastic box 4 module 7x4 inch size complete all as specified and directed.
Supply and fixed in repairs surface mounting plastic box 6 module 8X6 inch size complete all as specified and directed.
Taking down DB/main switch of any size and making good disturbed surface of wall/floor complete all as specified.
Supply and fixed in repairs MCB DB Single pole and neutral 8 way double door with 200 amps rated bus bar complete all as specified and directed.
Supply and fixed in repairs MCB four pole 'C' Curve 240 Volts of capaicty 63 Amps 10 KA rating complete all as specified and directed.
Supply and fixed in repairs MCB single pole & neutral 'C' Curve 240 Volts of capaicty 6-32 Amps 10 KA rating complete all as specified and directed.
Supply and fixed in repairs MCB single pole & neutral 'C' Curve 240 Volts of capaicty 40-63 Amps 10 KA rating complete all as specified and directed.
Supply and fixed in repairs MCB single pole 'C' curve 240 Volts 6-32 Amps, 10 KA rating complete all as specified and directed.
Supply and fixed in repairs sheet metal enclouser with single pole and neutral with a two pin and earth plug and socket complete with one double pole 20 Amp MCB complete.
Supply and fixed in repairs sheet metal enclouser with triple pole and earth enclouser with a three pin and earth plug with socket complete with one triple pole 63 Amp MCB complete.
Taking down sub main wiring of any size complete and making good disturbed surface of walls/floors etc complete as specified.
M&L for submain wiring with two single core PVC insulated unsheathed stranded copper conductor 4.0 sqmm (nominal area) drawing through PVC casing caping and 2.5 sqmm stranded copper conductor cable PVC insulated and unsheathed (green colour) 1100 volts grade for earth continuity conductor and connecting with main earth dolly Note:- (i) 2 runs of 4 sqmm cable and 1 run of 2.5 sqmm single core copper cable and 1 run of non metalic PVC casing capping shall be measured as single run.
M&L for earthing complete with GI earth plate electronic 600 x 600x 6mm buried directly in ground vertically to a depth of not less than 2.25 m below ground level with the top edge of earth plate at a depth of not less than 1.5 mtr below ground level connected to GI earth lead 4 mm dia by means of nuts bolts washers etc made out of galvanized iron and GI wire connected to main switch/DB board including necessary excavation and earth work PCC (1 3 6) type C1 using 20mm graded stone aggregate earth chamber 40mm thick RCC cover type B1 (1 2 4 ) B1 using 20mm graded stone aggregate 20mm dia GI medium grade protection pipe upto main switch board etc complete all as shown in electrical plate No 3 of MES Schedule Part I.
Supply and fix in repair suitable size of factory made bus bar chamber wall mounted 200 Amp capcity with four no copper strip 250 mm length on insulator, provision of 10/16 sqmm cable entry ,colour coading of strip, 2 mm thick MS sheet complete all as directed.
Disconnection of electrical wire from ceiling rose, taking down ceiling Fan of any type/Size and make, dismantling the ceiling Fan, wahsing and removing of old lubricating sub Statance from bearing/bush using Kerosine oil, carying out fresh lubrication using grease and to make the ceiling Fan noise free for smooth funct ioing, including replacement of worn out/unserviceable spares as required, replacement of PVC insulated, unsheathed stranded twin twisted copper conductor cable of size 1.5 Sqmm up to 1.0 M long, assembling the repaired ceiling fan and testing to the entire stisfication of engineer in charge and hanging at position, connection with point wiring & testing co mplete. (Replacement of Spares flexible wire etc/rewirding of ceiling fan/shall be measured and paid seperately under respective item for material and labour cost .)
All as per item No 36 above but excluding of Disconnection, taking down and refixing of ceiling fan (unserviceable ceiling fan to be iussed to contractor from MES store and repaired ceiling fan to be deposited at MES store)
All as per item No. 36 above but for exhaust Fan 250 -300 mm sweep
All as per item No. 36 above but for exhaust fan 380/400 mm sweep
All as per item No 36 above but for wall mounting Fan of size above 400 mm weep and up to 600 mm sweep
Rewinding of motor of AC ceiling fan, of any make/type and size (1200/1400 mm sweep) with super enamelled copper wire of appropriate gauge as existing to obtain the specified and satisfactory RPM as per menufactures specification, including replacement of all insulation materials, varnishing, heating, drying, assembling of stater/rotor, connection & testing complete.
All as per item No. 41 above but for exhaust fan of any make/type and of size 250- 300 mm sweep
All as per item No. 41 above but for exhaust fan of any make/type and of size 380/400 mm sweep
All as per item No. 41 above but for wall mounted fan of any make/type and size above 400 mm sweep up to 600 mm sweep
Carrying out remetalling in worn out shaft, cutting and polishing to make the shaft suitable for fixing of new ball bearing and fixing ball bearing in replacement of bushing system in ceiling fan and assembling the same and testing to the engineer satifaction of engine in change to ensure smooth and noise free operation (bearing shall be measured and paid seperately )
Supply and fixing in replacement of ball bearing of any size and type, suitable for any type/make/size of ceiling fan complete all as directed.
Supply and fixing in replacement of ball bearing of any size and type, suitable for exhust fan of any type/make and size (250 to 380/400 mm) complete all as directed.
Supply and fixing in replacement of ball bearing of any size and type, suitable for wall mounted fan of any type/Make and size up to 600 mm sweep complete all as directed.
Supply and fixing in replacement of capacitor MPP type 440 Volt AC 50 Hz, conforming to IS-1709 and Rated capacity 2.5 MFD complete all as directed.
Supply and fixing in replacement of capacitor MPP type 440 Volt AC 50 Hz, conforming to IS-1709 and Rated capacity 4.0 MFD, conforming to IS 2993 complete all as directed.
Supply and connection of PVC insulated, unsheathed stranded,three core twisted copper flexible cable of size 1.5 Sqmm complete all as directed.
Supply and connection of PVC insulated, sheathed round stranded copper conductor cable of size 2.5 Sqmm 3 core confirming to IS 694/1990 complete all as directed.
Supply and fixing only bush of suitable size for exhaust fan of any type/size as per existing type.
Supply and fixing only bush of suitable size for wall mounted fan of any type/size as per existing type.
Supply and fixing in repair of PVC connector 4 way 6 Amps with connection screws, nuts complete all as directed.
Supply and fixing in repair of PVC clamps with fixing screws for holding capacitor of any type and size complete all as directed.
Supply and fixing 'S' type hook made of 12 mm dia MS round bar/MS flat strip 40x4 mm of appropriate size after taking out old rusted wornout hook.
Supply and fixing of MS anodized bolts with anodized nuts, spring washers, split pin etc size 50 mm long 10 mm dia half threaded type with split pin hole
Supply and fixing of MS anodized bolts with anodized nuts, spring washers, split pin etc size 50 mm long 8 mm dia half threaded type with split pin hole
S&F clamp for down rod of suitable size including gromet/reel type rubber pad with bolts, nuts and washers suitable for housing ceiling fan.
Taking out old, broken and rusted louver shutter of exhaust fan from wall for necessary replacement all as direted.
Supply and fixing of louver shutter made of MS sheet metal 1.2 mm thick for round base and 0.8 mm thick for flaps, comprising of mounting legs frames made o MS flat strips of size 25mm x 3mm includidng heavy duty rust proof passivated bolts of size 50 mm long 8 mm dia to be fixed on wall fater driling, and duly painted by two coat of synthatic enamelled paint (spray painting) over a coat of primer for exhust fan up to 300 mm sweep complete all as directed.
Supply and fixing of louver shutter made of MS sheet metal 1.2 mm thick for round base and 0.8 mm thick for flaps, comprising of mounting legs frames made o MS flat strips of size 25mm x 3mm includidng heavy duty rust proof passivated bolts of size 50 mm long 8 mm dia to be fixed on wall fater driling, and duly painted by two coat of synthatic enamelled paint (spray painting) over a coat of primer for exhust fan fan 380 / 400 mm sweep complete all as directed.
Cleaning of ceiling fan assembly of any type/size and carrying out two coat of spray painting with first quality synthetic enamelled paint of approved colour, including writing of MES number in black paint all as directed and specified.
Cleaning of exhaust fan assembly of any type/size and carrying out two coat of spray painting with first quality synthetic enamelled paint of approved colour, including writing of MES number in black paint all as directed and specified.
Supply only PVC canopy suitable for ceiling fan of any type/make for both end of down rod including fixing scrws complete all as directed.
Repair to oscillation unit of wall mounted fan including replacement of all wornout components, bearing , lubrication and assembling complete.
Supply and fixing in replacement of electronic regulator 400/450 watt step type complete all as directed.
Supply and fixing in replacement of steel anodized down rod clamps including rubber gromet, bolts,nuts, split pin complete set.for ceiling fan of any type/make.
Taking out/down water heater of any type and capacity at different units and servicing of the same incl cleaning heating element, water pipe, checking of electrical connections, and checking of NRV , safety valve/air release valve etc and refixing of the same after servicing , connecting with inlet and out let water connection and electrical connection and testing complete all as specified and directed.
Supply and fixed in repairs of heating element of Cup type of capacity 1500 W in any type of electric water heater complete all as specified and directed.
Supply and fixed thermostate in replacement suitable for water heater of any type/size complete all as specified and directed.
SCHEDULE OF CREDIT (As per Schedule of Credit in Srl page No___)
M/S Ali Trading Co
Abida Enterprises
VERSATILE CONSTRUCTION
M/S SINGH ENTERPRISE
ANSH CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .