| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.2 LAccepted-AOC FLAT NO 107 C WING SKYWAYS SERENO LOHEGAON PUNE 411 047 | PUNE | PUNE | MAHARASHTRA | 411047 | L1 | Accepted-AOC L1 | |
| 2 | L2₹35.9 L+₹6.7 L (23.1%)Rejected-Finance SADASHIV PHUGE NAGAR OPP SANDVIK FACTORY RADHIKA RESIDENCY F WING FLAT NO 7 PHUGEWADI PUNE 411 012 | PUNE | MAHARASHTRA | 411012 | L2 | Rejected-Finance not being lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
4 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (CME) Kirkee
Garrison Engineer (CME) Kirkee, Phugewadi, Dapodi, Kendriya vidyalay Gate , beside Unlimited (Mega Mart) Mall, Pune - 411 012
Repair and maint of pump panels, flowmeters and certain connected items for water distribution system in CME
2022_MES_565321_2
8379/E8
Open Tender
Water Equipments/ Meter/ Drilling/ Boring
Item Rate
180 days
Garrison Engineer (CME) Kirkee
Class D, category a(ii)
9 documents required · 9 mandatory
₹500
Yes
Garrison Engineer (CME) Kirkee
₹80,000
Yes
17 Feb 2023
22 Dec 2022
6 Jan 2023
22 Dec 2022
4 Jan 2023
23 Dec 2022
Amount
Material and labour for dismantling the Blower set (Twin Lobe Blower- 5m3/hr) complete up to 7.5 HP and carrying out repair/replacement for defective parts such as bearing, shaft sleeves, gland plate, impeller, including replacement of worn out nuts, bolts, filling of pump oil heavy grade (Super-90), greasing of bearing, replacement of gasket, mechanical seal, rotor job, replacement of belts,etc. complete all as directed and reassmebling, testing & commissioning. Note: 1. Charge for making arrangement for lifting up blower motor shall be deemed in quoted rates. 2. Once the motor set repaired, the contractor shall by default get the bearing, and other necessary parts changed and shall remain responsible for proper functioning of motor pump for complete one year from the date of repair. No extra cost will be paid to the contractor for any other repair work if at all required within this duration of one year. 3. Quoted Rate include for Alignment of Shaft, Servicing of Motor, servicing Of Blower, Servicing of Gear Box and Grease Required at job Work.
M&L dewatering, cleaning of sewage water collection U/G tanks with high pressure jet to remove all mosses, algae and dirt and removal of dirty water along with sludge machines/industrial vacuum cleaners and disposal of the same to a safe distance including scrubing of internal surface by steel wire brush, removing the dirt completely using industrial vacuum cleaners and sterilizing the complete internal surface of the tank by using ISI mark Gd I bleaching powder and marking the date of cleaning by using synthetic enamel paint in white colour over black background and letters of height 40 mm and 30 mm width complete all as directed for the following sizes:- Note: If the work is not done upto satisfaction level of EIC, the work will be redone upto required level without any extra cost. Neccessary tools and safety gears to be arranged by contractor without any extra cost. Safety of labours shall be contractors responsiblity. Also, sludge should be picked and disposed off beyond 500 mtr of STP premises
M&L for cleaning of STP/pump house and surrounding area by surface excavation upto 10 cm depth incl removing shrubs, grass, miniplants and other unwanted materials and levelling complete in soft/loose soil all as specified and directed.
M&L for earthing complete with 600x600x6mm galvanised steel earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5m below ground level, connected to and including G.I. Strip of size 32x6 mm by means of bolts, nuts and check nuts and washers of galvanised steel to the extent of 7.5 metres as earthing lead and connecting to the eqpt/machinery etc. incl charcoal dust and common salt packed all around the earth plate in alternate layer in the earth pit all as per electrical plate No. 3 of SSR Part I-2009 including chamber made up of PCC 1:2:4 type B1 with M.S. angle iron frame, C.I. Cover, 20mm dia light grade G.I. Pipe from top edge of the earth plate upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement incl excavation and earth work in any type of soil and testing complete all as specified and directed.
Supply and float suspended plastic carriers (as available on site) with large protected surface areas for the growth of bacteria and proper decomposition of sludge in all three tanks complete all as specified and directed by Eng-In-Charge.
Supply and erect steel tubular poles swaged welded poles complete with MS base plate MS pole cap bolts nuts and screws as per IS 2713 (part II) 1980 made out MS tubing duly painted with metal primer and 2 coats of aluminium paint over exposed surface and one coated of red oxide and 2 coat of bituminous paint for embedded portion as specified type 410 SP - 55 of 11 mtrs long all as specified and directed Note : Excavation earth work & PCC shall be measured and paid separately under relevant items
Supply & Fix in replacement PVC insulated sheathed wire with copper conductor flexible 2 core 4 Sq mm for connecting street light fitting from over head line /pole boxes complete.
Supply and fixing Integral LED Street Light Luminaire 50 W, 6500K comprising of epoxy powder coated aluminium housing, enclosed with glass cover in frame suitable for 50/40 mm GI Pipe complete with accessories. Make : Havells/ Philips/ Bajaj/ Crompton Greaves/ Wipro/ Shakti/ Halonix/ Jaquar/ Benlac India Ltd. all as specified including taking down old fitting and directed.
Supply and fixing in repairs Pole Flood Light Fitting Bracket round shape suitable for four flood light fitting made of Angle iron bar (50x50x6mm) of suitable size complete specified & directed by Engn-In-Charge.
Supply and fixing in replacement LED flood lights fitting 150 watts, 5700K with die cast housing and toughened glass cover Specially designed for LED Floodlight luminaire,heat resistant tempered glass for protection including copper wire with connection and switch,etc at the nearest point Make : Havells/ Philips/ Bajaj/ Crompton Greaves/ Wipro/ Shakti/ Halonix/ Jaquar/ Benlac India Ltd.
Supply and fix in repairs FRP junction box light weight suitable for pole mounting including MCB SP 6 Amps single pole and necessary connector for loop in loop out cable connection and suitable size glands of size 250 x200x100mm Make: Sintex/ Havells
Supply, lay, test connecting and commissioning underground cable LT 1100 volt grade heavy duty XLPE insulated with aluminium stranded conductor armoured complete laid in trenches/fixed to poles /drawn through pipes with suitable size cable glands criping type cable lugs etc all as specified and directed of size 16 Sqmm 4 core including taking out old unsv LT cable.
Material and labour for cross arms, bracing supports, clamps fabricated out of structural steel such as ISMC, angle iron, flat iron sections including hot galvanised nuts & bolts, washers for single and two pole structure welding, bending cold or hot, drilling holes for bolts, in any shape or size as specified and including of one under coat and finishing coat with aluminium paint over a coat of red oxide primer. Note: Fabrication, welding and transportation is inclusive in the rate itself.
Dismantling of old coverd shed of size 4m x 4m x 4m and M&L for hardcore of brocken stone of guage exc. 63 mm but not exceeding 100mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface, cement concrete type C2 1:3:6 (40mm graded stone aggregate) as in foundation filling and mass concrete, cement concrete type A1- 1:1.5:3 (using 20mm graded stone aggregate), 150mm thickness as in hardstandings, fixing of new roof trusses (framed ), trussed, purlins, crane gantries, rails and fastning and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, replacement with new pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, preparation of steel surface and applying one coat of red oxide zinc chrome primer and two coats of Epoxy anticorrosive paint over 10 cm width or girth including excavation returning, filling, removing and connected jointing and fabrication work all as specified and directed by Engineer-in-Charge. Note for covered shed :- Main frame shall be angle iron of size 50mm x 50mm x 5mm and truss angle frame shall be of minimum 40mm x 40mm x 5mm, shed area shall cover minimum 2 metre beyond PCC plinth protection of pump/ motor / blower etc around it and 2 metre above the highest point on the pump/ motor/ blower etc.
Dismantling and taking out unserviceable Dry Motor submersible sewage pump set having flow : 800m3/hr, 15 mtr head self cooling jacket system and solid handling capacity 100mm installed at STP Kasarwadi of capacity 70HP, Make Kishor Pumps, Model ASTRA SA 250-315 with the following work services:- a) Disconnecting water and electric connections, shifting the pump from Pump house to workshop ( to and frow) for carry out necessary repair. b) Opening the pump completely part by part without damaging any parts, descaling and cleaning of all parts for inspection and finding serviceability/ unserviceability of the parts. c) Repair and assembling of pumps by using existing serviceable parts and replacement of unserviceable parts as directed including necessary machining works required for proper setting and smooth functioning to achieve desired discharge of the pump. d) Re install the pump at its existing foundation, making electric and water connections, finally testing the pump set for its trouble free functioning complete.
Note : (i) Spare parts required for replacement shall be measured and paid seperately under appropriate items as supply only. (ii) Any Machining works required for balancing of impeller /for fixing of new parts with existing shafts is deem to be included with the unit rate. No extra amount on this account shall be entertained seperately. iii) Any minor parts which are not covered under this schedule but inescapable requirement for repair shall also be deem to be included with the unit rate quoted. No extra on this account shall be entertained by the Department. (iv) No extra cost will be paid to the contractor if taking out and lowering of motor and pump is done on same motor and pump which is being repaired once. It will be contractor responsibility to ensure all parameters before lowering the pump and motor.
M&L for disconnecting and removing the PUMP SET from its foundations/ base frame located at different locations, by disconnecting suction, delivery pipes, pump couplers and electrical connections, taking it to workshop for repair, Dismantling and opening up of PUMP assembly complete, removing worn out Gland, bush, shafts, pump Housing, bearing, Gland Packing, Pin locking set, nuts and bolts, washers etc., and replacing with new parts of same make/model/type including necessary machining works as required, assembling, Balancing and refixing the pump back to its postion after getting repair and making all connections, carry out alignment, and testing for satisfactory function all as specified and as directed for following Pumps:-
All as per Item No.16 above, but non clog submerible sewage non clog pump of following capacities by taking up/down from sewage sump including taking up/down suction & delivery pipes & connections and refixing all as speciifed and as direted by Engineer In Charge
Model No KDV, 312V, 365 Capacity: 10Cum/Hr @ 15m Head coupled with 5HP three phase electric motor Make: Kirloskar Note : Notes as per Item No.15 applicable here also
Supply only following parts of Dry Motor submersible sewage pump set, Model ASTRA SA 250-315 Kishor pump of capacity 70 HP to incorporate under item No.15 above (as per site requirement) for satisfactory repair of the pumps.
Impeller for Model ASTRA SA 250-315
Double mechanical seal ( Internal & External) for Model ASTRA SA 250-315
Mechanical seal cover for Model ASTRA SA 250-315
Upper bearing for Model ASTRA SA 250-315
Lower bearing for Model ASTRA SA 250-315
Cable gland for Model ASTRA SA 250-315
Cable seal for Model ASTRA SA 250-315
Stuffing box bush for Model ASTRA SA 250-315
Bearing grease for Model ASTRA SA 250-315
Hose clip for Model ASTRA SA 250-315
Oil seal for Model ASTRA SA 250-315
Lower Bearing housing for Model ASTRA SA 250-315
Impeller screw for Model ASTRA SA 250-315
Supply only for fixing against Item No.17 above, the following spares parts of pump of non clog pump set suitable for 7.5/5 HP pump :-
Impeller
Mechanical seal
Suction plate
Bearing sleeve
Shaft nut with washers
Bearing bush suitable
Neck ring suitable
Casing wear ring
Strainer
Shaft seal
Stuffing box bush
Taking down the motor from base plate/ pump after disconnecting the electrical connection and transporting to & from workshop for cutting (i.e machining,work, welding, grinding, turning & polishing, lathe work, filler work etc.) & taking burn out copper winding complete and cleaning properly. Rewinding the motor with same gauge and same turn ratio for proper RPM, best quality copper enamelled winding wire and packing properly with packing materials, varnishings, drying & replacing wornout bearing/terminal plate, reassembling, fixing in original position, testing & commissioning complete of following sizes all as directed by Engineer-in-charge Note: 1. All parts to be changed and neccessary for proper functioning except bearings is inclusive in the rate itself. 2 . Notes from Item No.15 are applicable here also.
Supply and fix in repairs front / rear ends bearing of same size as existing suitable for motor incl all fiiting,fixtures,etc (incl taking out motor if not in repair) as directed by Engr-in-charge as following : -
Supply and install CI foot valve of size 250mm all as per IS 4038 Class PN 0.2 with taking down old u/s foot valve
Supply and fixing in repairs Electromagnetic flow meter with DC pulsed SS 316 electrodes, ISO-4064 accuracy upto 0.5% incl sensor transmeter, surge arrestor cable of size 400 mm dia with sensor construction and housing, Flow transmitter microprocessor based, LED indication for flow rate, IP-67/68, Housing material - Aluminium, process connection material- carbon steel, signal cable- 10 m long, calibration type - 0.4% factory calibration, Housing type/material - Field mount/single compartment complete all as specified and directed by Engr-In-Charge. (Endress Hauser Model No 10L4H-U20A1AN4B4AA all specifications to be as per model suggestion) Make:- ABB/GE/Endress Hauser
M&L for PCC (1:4:8) type D-2, using 40 mm graded stone aggregate as in foundation concrete, mass concrete etc. (For road crossing dressing)
M&L for PCC (1:3:6) type C-2, using 40 mm graded stone aggregate as in foundation concrete, mass concrete etc.
Supply, installation testing and commisioning indoor LT Panel 415 volt for wire AC 50 Hz factory made, CPRI Approved floor mounted, indoor type panel, cubicle type, Compartmentalized, dust & vermin proof, indoor installation IP 42 Type Electrical control panel duly powder coated By 7 Tank painting process made out of MS sheet of size 2 mm thick powder coated and mounted on angle iron frame, 40 cm height above ground level duly fixed with PCC etc, including contol wiring complete to accomodate the items and accessories as under power cables, wirings, lugs,control cables,etc.
ACB - 4P 1000A, 415V, 50KA MDO Microprocessor based - 01 No. (L&T)
Busbar Aluminium - 100 x 10 mm - 04 Nos
Multifunction Meter- Voltage, Current, PF, KWH etc - 01 No
Current Transformer-1000 / 5A, 5VA, CL 1, Round Cast Iron - 03 Nos
Indications - 03 Nos
Control MCB - 6A 3P
Feeder 1 to 8 - 250 A,3P,50 KA, rotary handle, spreader link, indicator- 08 Nos (L&T)
Space heater - 02 Nos
Thermostat -01 No.
Supply, installation testing and commisioning indoor LT Panel 415 volt for wire AC 50 Hz factory made, CPRI Approved floor mounted, indoor type panel, cubicle type, Compartmentalized, dust & vermin proof, indoor installation IP 42 Type Electrical control panel duly powder coated By 7 Tank painting process made out of MS sheet of size 2 mm thick powder coated and mounted on angle iron frame, 40 cm height above ground level duly fixed with PCC etc, including contol wiring complete to accomodate the items and accessories as under power cables, wirings, lugs, control cables,etc :
70HP Soft Starter - Digital Soft starter with bypass contactor -01 Nos (L&T)
ON/OFF/TRIP indication - 03 Nos (As per colour code)
VAF Meter-Digital Meter - 01 No.
Start/Stop Button- 02 Nos (As per colour code)
Current Transformer-250/5 5VA-03 Nos
Overload Relay-CT operated - 01 No.
Water level Sensor - 01 No.
Space Heater -01 No.
Thermostat -01 No.
Busbar Aluminium - 50 x 10 mm - 04 Nos
Timer - 02 Nos
Single phase preventor - 01 No.
Power Factor Controller -Microprocessor based Intelligent Three Phase Load Sensing-1 No (EPCOS)
250A MCCB 3P 36KA-Main Incomer-1 No. (L&T)
VA Meter--1 No. (Multispan)
CT - 250/5--3 Nos.
Indications-Red Yellow Blue-3 Nos.
4A 3P MCB -For Indications & VA Meter-1
4A SP MCB-For Fans-1
4A SP MCB-For Control Circuit-1
8inch Fans-For Ventilation-3
2KVAR, 440V :
Capacitor -2 KVAR, 440V MPP Heavy Duty-1 No. (EPCOS)
Contactor -2 KVAR Cap Duty -1 No. ( EPCOS)
MCB-10 A 3P 10 KA C Curve-1 No. (L&T)
ON Indication-Red 230V-1
OFF Indication- Green 230V-1
ON OFF Switch- Auto Manual Switch-1
Power Cable-1.5 Sqmm Cu
Control Cable-1.5 Sqmm Cu
3KVAR, 440V :
Capacitor -3KVAR, 440V MPP Heavy Duty-1
Contactor -3KVAR Cap Duty -1
MCB-16A 3P 10KA C Curve-1
ON Indication-Red 230V-1
OFF Indication-Green 230V-1
ON OFF Switch-Auto Manual Switch-1
Power Cable-2.5 Sqmm Cu
Control Cable-1.5 Sqmm Cu
5KVAR, 440V :
Capacitor -6.8 KVAR, 525V MPP Heavy Duty-1 No. (EPCOS)
Contactor -5KVAR Cap Duty -1 No. (EPCOS)
Reactor-5KVAR 7% Detuned reactor-1 No. (EPCOS)
MCB-16A 3P 10KA C Curve-1
ON Indication-Red 230V-1
OFF Indication-Green 230V-1
ON OFF Switch-Auto Manual Switch-1
Power Cable-2.5 Sqmm Cu
Control Cable-1.5 Sqmm Cu
10KVAR, 440V :
Capacitor -12.5 KVAR, 525V MPP Heavy Duty-1
Contactor -10 KVAR Cap Duty -1
Reactor-10 KVAR 7% Detuned reactor-1
MCB-32A 3P 10KA C Curve-1
ON Indication-Red 230V-1
OFF Indication-Green 230V-1
ON OFF Switch-Auto Manual Switch-1
Power Cable-4 Sqmm Cu
Control Cable-1.5 Sqmm Cu
25KVAR, 440V :
Capacitor -33KVAR, 525V MPP Heavy Duty-1
Contactor -25KVAR Cap Duty -1
Reactor-25KVAR 7% Detuned reactor-1
MCB-63A 3P 10KA C Curve-1
ON Indication-Red 230V-1
OFF Indication-Green 230V-1
ON OFF Switch-Auto Manual Switch-1
Power Cable-16 Sqmm Cu
Control Cable-1.5Sqmm Cu
25KVAR, 440V :
Capacitor -33KVAR, 525V MPP Heavy Duty-1
Contactor -25KVAR Cap Duty -1
Reactor-25KVAR 7% Detuned reactor-1
MCB-63A 3P 10KA C Curve-1
ON Indication-Red 230V-1
OFF Indication-Green 230V-1
ON OFF Switch-Auto Manual Switch-1
Power Cable-16 Sqmm Cu
Control Cable-1.5 Sqmm Cu
25KVAR, 440V :
Capacitor -33KVAR, 525V MPP Heavy Duty-1
Contactor -25KVAR Cap Duty -1
Reactor-25KVAR 7% Detuned reactor-1
MCB-63A 3P 10KA C Curve-1
ON Indication-Red 230V-1
OFF Indication-Green 230V-1
ON OFF Switch-Auto Manual Switch-1
Power Cable-16 Sqmm Cu
Control Cable-1.5 Sqmm Cu
25KVAR, 440V :
Capacitor -33KVAR, 525V MPP Heavy Duty-1
Contactor -25KVAR Cap Duty -1
Reactor-25KVAR 7% Detuned reactor-1
MCB-63A 3P 10KA C Curve-1
ON Indication-Red 230V-1
OFF Indication-Green 230V-1
ON OFF Switch-Auto Manual Switch-1
Power Cable-16 Sqmm Cu
Control Cable-1.5Sqmm Cu
Accessories:
Busbar Aluminium-- 50 x 10 mm - 04 Nos.
Space Heater--2 Nos
Thermostat--1 No.
M & L for carry out water quality anyalysis for bacterial, chemical and biological analysis including for collection of water samples from the pump house and one of the location as specified by Engineer In Charge and testing from govt approved testing laboratory/FHHL lab, submitting of reprort for minimum following parameters (a) Turbudity (NTU) (b) pH (c) Total Hardness as CsCO2 (mg/l) (d) Sulphate as SO2 (mg/l) (e) Iron as Fe (mg/l) (f) Magnesium as Mg (mg/l) (g) E-Coli or thermotolerant coliform bacteria (h) Remarks of Govt water testing lab
M & L for Framed work such as grills, gratings, bar, flat plates etc. conforming to Fe.290.Gde-E-165 with two coat of synthetic enamelled paint over a coat of red oxide primer including preparation of new steel surface incl taking down old unsrviceable one all as directed and specified by Engineer In Charge
M&L in replacement Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, thickness of laths 1.25 mm, complete gear operated type with bevel gear box and crank handle complete as directed by EIC
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m deep and making good surface for laying /removing of cable all as specified and directed by Engr in charge as in
Soft/loose soil
Hard/dense soil
Returning, filling in, including spreading, levelling watering and well ramming in layers of soil not exceeding 25cm.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point of soil.
Supplying and laying of Telerex DWC (Double wall corrugated) armoured HDPE pipe ISI marked of outer dia of 77 mm and inner dia of 63 mm polythlene with smooth internal and profiled external surface for non pressure underground cable incl couplers & bends complete all as specified by EIC. Make: Rex Polyextrusion Ltd or equivalent as approved
Supply and laying ductile iron pipe with internal cement mortar lining and external zink pipes with class of pipe K-9 of following sizes:-
400 mm dia bore
Supply and fix cast iron sluice valve flanged of class 1.6 PN brass spindle supplied and installed complete for following sizes :-
400 mm bore dia pipe
Supplying, fixing and testing of CI/DI pipe fitting for spigot socketed pipes such as bends (any type, radius and angle), tapers any type (straight, bend, increasing/ decreasing or double socket etc). Tee pieces, single branch, “Y” junction, double branch, cross (all sockets or socket and spigot), collars, caps and plugs, for pipe upto 400mm bore all as specified & directed by Engineer-in-charge. Note:- Rate of cutting existing pipe for insertion of the fitting or any fabrication for connecting the existing pipe with new pipe is included in the quoted rate.
M&L in repair for PCC block masonry and PCC 1:4:8 type D2, using 40mm graded stone aggregate as in foundations, filling and mass concrete for DI/CI water pipelines complete by using necessary clamping of pipe in foundation to avoid vibration at the time of pumping operation complete with demolition of existing foundation and necessary earthwork complete all as specified and directed by Engr-In-Charge. Note: Minimum size for foundation L x W = 1 m x 1 m but height will vary from site to site. Contractor should quote the rate according to the condition mentioned and reviewing site.
M/S kirpan Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .