Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAccepted-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L1 | Accepted-AOC Accepted due to lowest rate quoted | |
| 2 | L2₹28.3 L+₹3.3 L (13.0%)Rejected-Finance | L2 | Rejected-Finance Rejected due to highest rate quoted | |
| 3 | L3₹28.6 L+₹3.5 L (14.0%)Rejected-Finance | L3 | Rejected-Finance Rejected due to highest rate quoted | |
| 4 | L4₹34.3 L+₹9.2 L (36.8%)Rejected-Finance A 47D RAM DUTT ENCLAVE UTTAM NAGAR NEW DELHI 110059 | WEST | DELHI | 110059 | L4 | Rejected-Finance Rejected due to highest rate quoted |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
21 Oct 2024, 6:00 pmClosed
GE (AF) GURGAON
GE (AF) GURGAON
REPAIR MAINTENANCE OF PERIMETER SECURITY LIGHTS SEARCH LIGHT SOLAR LIGHTS HIGH MAST LIGHTS SOLAR WATER HEATING SYSTEM AND FIREFIGHTING FIRE DECTION FIRE ALRAM SYSTEM AT 2003 STN UNDER GE (AF) GURGAON
2024_MES_676138_1
GE/GUR-/NIT-32/2024-25
Open Tender
Civil Works
Item Rate
240 days
GE (AF) GURGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) GURGAON
₹70,000
9 Nov 2024
23 Sept 2024
23 Oct 2024
23 Sept 2024
21 Oct 2024
7 Oct 2024
Amount
Excavation in trenches n exc 1.5 wide and n exc 1.5 m in depth for foundation etc or for laying cable etc n exc 10 Sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning filling in including spreading, leveling, watering and well ramming in layers exc 25 cm thick complete all as specified and as directed.
Removal of excavated material/surplus soil to a distance n exc 50m and depositing where directed at a level n exc 50m above the starting point complete all as specified and as directed.
Supply and filling river sand in trenches including spreading for cushioning of LT UG cable complete all as specified and as dirceted. Note : Punned down thickness shall be measured and paid .
M&L for sub class ‘B’ bricks old size laid flat dry in trenches over cable, across the direction of cable complete all as specified and as dirceted.
Supply, laying and testing in replacement of cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 Volts grade cross sectional area 3.5 core x 300 Sq mm complete all as specified and as dirceted. Note : Provision of suitable double crimpped lugs and glands shall deemed to be included in quoted rates.
All as per item No 6 described here in before but 3.5 core 185 sqmm.
All as per item No 6 described here in before but 3.5 core 120 sqmm.
All as per item No 6 described here in before but 3.5 core 95 sqmm.
All as per item No 6 described here in before but 3.5 core 70 sqmm.
All as per item No 6 described here in before but 3.5 core 50 sqmm.
All as per item No 6 described here in before but 3.5 core 35 sqmm.
All as per item No 6 described here in before but 4 core 25 sqmm.
All as per item No 6 described here in before but 4 core 16 sqmm.
Supply and fix in replacement of aluminium busbar of LT panel of rating upto 630 Amps.Note- 1 RM consists of R,Y,B and N)
M&L for repairs of ACB (air circuit breaker) draw out type of rating 1250 Amps 4 pole, 50 KA, O/L, S/C, micro processor based release and cassette mounted horizontal draw out type fully interlocked cassette door automatic safety shutters, mechanical on and off indicators, service/test/isolated position with position indicators, provision of castell lock, with O/L, S/C with 3 CT's of standard ratings 4 blocks of 6 way sliding type LT disconnectors, error prevention plug, racking handle, safety shutters and painted with finished light grey shade as per IS:631 and as per IS 13947-2-1993 inclusive suitable length of bus bars complete all as specified and as dirceted. (All repair cost and replaceable items cost includes in the quoted rate and US item is of contrator's property and rate quoted included in this))
All as per item No 8.00 described here in before but 800 Amps.
S&F in replacemnt of MCCB with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning complete all as specified and as per existing model/make of the following sizes:-
100 Amps 4 Pole breaking capacity 35/36 KA.
160 Amps 4 Pole breaking capacity 35/36 KA.
200 Amps 4 Pole breaking capacity 36 KA.
200 Amps 3 Pole breaking capacity 36 KA.
250 Amps 4 Pole breaking capacity 36 KA.
250 Amps 3 Pole breaking capacity 36 KA.
400 Amps 4 Pole breaking capacity 36 KA.
630 Amps 4 Pole breaking capacity 50 KA.
M & L in replacement for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including using galvanised iron strip 32×6mm as earthing strip by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth plate surrounded by packed layer of char coal dust and common salt, 15cm thick all around bottom and top and watering pipe 20mm bore of GI light grade with funnel, wire mesh and 40 mm dia GI protection pipe medium grade all as shown in electrical plate No 3 of SSR Part-I and connected to earthing test point, main switch board and testing on completion including excavation, earth work concrete pit with 80mm thick RCC cover in RCC 1:2:4 type B-1 duly reinforced with MS bars 8mm dia @ 150C/C both ways and pit chamber in PCC 1:2:4 type B-1 with 2 Nos suitable lifting handles of 12mm MS bar complete all as specified and as dirceted.
Supply and lay in trenches GI strip 25 mm x 4 mm galvanised iron strip for earth continuity earthing complete all as specified and as dirceted.
M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as dirceted.
M&L for defect rectification high tension or LT cable of any size and laid in trenches by fault locating machine comprising of surge generator pulse,ECHO fault locator with high frequency distance calculator etc and exposing the cable fault,removal of deteriated portion of cable , treating of cable and making the same ready for jointing work complete all as specified and as dirceted. Note : (i) Cost of necessary excavation and earth work (by hydra machine or manual which suits), labour,fixing charges & T&P including removing of grass/shrubs nearby the fault location shall be deemed to include in quoted rates. (ii) This item also includes charges for exacavation in concrete/pitched road (by hydra or any means) in case fault occurs in the cable below the road or hard concrete area and making good the same as orginal finish.
M&L in repair for cold shrinkable jointing kit including suitable size of connector complete all as per directed by Engr-in-charge. Note : Cost of necessary excavation and earth work (by hydra machine or manual which suits), labour, Jointing kit complete, fixing charges & T&P including removing of grass/shrubs nearby the fault location shall be deemed to include in quoted rates) complete all as specified and as dirceted for the following sizes :- Note- This item also includes charges for exacavation in concrete/pitched road (by hydra) in case fault occurs in the cable below the road.
(a) XLPE Cable of size 16 sqmm to 50 Sqmm x 3.5/4 core .
(b) XLPE Cable of size 70 sqmm to 120 Sqmm x 3.5/4 core .
(c) XLPE Cable of size 185 sqmm to 240 Sqmm x 3.5/4 core .
(d) XLPE Cable of size 300 sqmm to 400Sqmm x 3.5 core .
Dismantling concrete poles any size complete and setting aside complete all as specified and as dirceted. Note: "Hydra Crane Charges deemed to be included in the quoted rates".
Supply, fixing and erection in replacemnt of steel tubular swaged pole type 410SP-31(9 Mtr long) Swan neck complete with CI base plate,taper plug,bolts,nuts,and screws etc duly painted internally and externally with metal oxide anti corrosive paint before errection and painting with two coats aluminium paint after erection complete all as cofirming to IS 2713 (part-1 to 111) and complete all as specified and as directed. Note : Necessary earth work and concrete shall be measured and paid separately
M&L for Foundation for Tubular swaged pole type including excavation , getting out, pole foundation with PCC (1:4:8) type D 2 (using with 40 mm graded crushed stone aggregate). Coping of pole with PCC (11:3:6) type C ( using with 20 mm graded stone agregate) and removing surplus soil to a distance n.exc 50 m and making good surface complete all as specified and as directed.
S&F in replacement LT volt meter (0-500) digital squire flush type of size 96x96 mm including necessary addition/ alternation of panel including cutting/welding of front side of panel board /feeder to match the existing panel board/feeder including taking out of unserviceable Volt meter complete all as specified and as dirceted.
S&F in replacement 1100 Volts grade LT Ammeter (0 - 300 A) digital squire flush & CT type with CT's including necessary addition/ alternation of panel including cutting/welding of front side of panel board /feeder to match the existing panel board/feeder taking out of unserviceable Ammeter complete all as specified and as dirceted.
S&F in replacement 1100 Volts grade LT Ammeter (0 - 500 A) digital squire flush & CT type with CT's including necessary addition/ alternation of panel including cutting/welding of front side of panel board /feeder to match the existing panel board/feeder taking out of unserviceable Ammeter complete all as specified and as dirceted.
Taking down old UNSV fidder pillar and Supply, fixing, testing and commissioning in replacement of feeder pillar panel single door floor mounted and wall/pole mounted outdoor type, as per IP-55 grade, made out of MS sheet 3.15 mm thick of size 540x525x200mm with aluminium bus bar 250 Amps, 4 strip (3 phase) complete drilled, insulated with colour coded insulation tape, mounted on insulators etc with RYB indicator, panel should be dust proof, vermin proof, powder coated , locking should be screw type, mechanical type, inter locking with 150 Amps 25 KA MCCB four pole for incomer cable, should have danger notice for 415 volts, AC, mounted on 50x50x6 mm angle iron frame having minimum 2 feet ground clearance duly embedded in and including PCC block (1:2:4) complete including termination of all incoming and outgoing cables with suitable size thimbles/lugs and glands etc and providing fixing arrangements including earthing lead fixing arrangement, complete all as specified and as dirceted. Note :- installation, testing, commissioning and connecting of incoming and outgoing cable connection LT feeder pillar panel shall included in rates quoted.
S&F vertical type load line distribution board, double door, 4 way AC, 3 phase 415 volts, TPN bus bar 200 Amps rating and earth bus and din rail including 01 No. MCCB 3/4 pole 415 volts, 50 Hz, 100Amps 16 KA breaking capacity as incomer complete all as specified and as dirceted.
S&F in replacement of MCCB 4 pole, 415 volts, adjustable type 63 Amps with breaking capacity 16 KA and connecting testing with MCCB complete all as specified and as directed.
Supply and fix in replacement of MCB SP 6-32 Amps 230 volts 'B' series complete all as specified and as directed.
Supply and fix in replacement of MCB SPN 40-63 Amps 230 volts 'C"' series complete all as specified and as directed.
M&L submain wiring with unsheathed multi-stranded FR Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 6 Sqmm single core HR Grade and one run of 4 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB complete all as specified and as directed. Note :- (i) Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete. Note (ii): Rates shall deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit.
Supply & fix in replacement of SPN enclosure with two pin and earth plug and socket complete with on SP MCB 20 Amps complete all as specified and as directed .
Supply & fix in replacement of DP enclosure with two pin and earth plug and socket complete with one DP MCB 32 Amps complete all as specified and as directed.
M&L for painting of steel tubular pole including cable protection pipe and all iron parts of 9 mtr long pole complete with 2 coats of aluminium paint after cleaning all rust and dust and preparing surface with wire brush and including strips of white and red colour of synthetic enamel paint up to the height of 1.5 mtr from the bottom of the pole complete all as directed.
M&L for preparation of old painted surface of electric RCC pole by removing all dirt, dust etc and apply approved colour one coat of syhnthetic enemal paint upto 1.5 mtr height (Five layer 30 cm Blue and 30 cm White one over another) and one coat of synthetic enamel paint on steel surface such as cross arm including writing of identification No , etc complete all as specified and as directed.
M&L for Spray painting to LT panel board with synthetic enamel high glow paint Ist grade including preparation/cleaning of steel surfaces complete all as specified and as dirceted.
Supply and fixing in replacement weather proof street light junction box of size 300 x 200 x 105mm including MCB SP 6 Amps and connecting terminals 4 way and fixing with street light poles using necessary MS clamps, nuts, bolts washers, lugs for incoming and out going cables, gland for cable etc of suitable size complete all as specified and as dirceted. Note : The rates quoted shall inclusive of provision and fixing of suitable lugs and glands for cable connection.
Material and labour for PVC flat twin core 2.5 sq mm aluminium wire 1100 volt grade laid in 20 mm dia medium grade rigid PVC conduit (and fixing brackets on PCC pole) from Loop-in-loop out junction box to light fitting terminal complete all as specified and as directed. Note :- PVC conduit shall be clamped properly with suitable clamps and no extra payment shall be done on this account.
M&L for replacement of rusted interal structure of LT panel of Size upto 7'5''X7'2''X3'2'' Shall be dust and vermin proof, protection class (IP-42) and made of 3.00 mm thick CRCA SHEET complete all as specified and as dirceted.
Supply only aluminium thimble heavy duty ISI mark suitable for 25 sqmm 3.5 cable complete all as specified and as dirceted.
All as item 36 above but 35 x 3.5 sqmm cable.
All as item 36 above but 50 x 3.5 sqmm cable .
All as item 36 above but 70 x 3.5 sqmm cable .
All as item 36 above but 95 x 3.5 sqmm cable .
All as item 36 above but 120 x 3.5 sqmm cable .
All as item 36 above but 150 x 3.5 sqmm cable .
All as item 36 above but 185 x 3.5 sqmm cable .
All as item 36 above but 240 x 3.5 sqmm cable .
Dismantling and taking down LED Street lights,, Dome/ Gate lights/ flood light fitting and bollards of any capacity, type or size for repair and replacement of worn out accessories and refixing on bracket on pole/wall after repair all as specified . Note- Any apare parts, led, starter, tools, man power, driver etc for making serviceable included into quoted rate complete all as specified and as dirceted. Note:- Rent for hydra is included in rates quoted by the contractor.
Removing out of carbon particle/sulphate from 9/11 mtr street light pole junction box/light fitting/OH conductor incuding cleaning and refixing properly to make light functional complete all as specified and as dirceted. Note:- Rent for hydra is included in rates quoted by the contractor.
S&F in replacement of Energy saving environment friendly Sentery Post/Sports ground Flood Light with innovative di cast aluminium IP 66 Flood light fitting with 120W LED as light source complete all as specified and as directed. Note: All fixing material is included in the unit rate.
S&F in replacement of Energy saving environment friendly Sentery pos/tSports ground flood Light with innovative di cast aluminium IP 66 Flood light fitting with 100W LED as light source complete all as specified and as dirceted. Note: All fixing material is included in the unit rate.
Supply and fixed in replacement of integral post top ideal to lit up luminaires energy saving 40 watt LED lamp, with symmetrical light distribution system di-cast aluminium luminairie with high power LED as light source including LED lamp complete all as specified and as directed. Note: All fixing material is included in the unit rate.
Supply and fix in replacemnt of automatic timer switch with switches ON/OFF the street lights base on lux level of natural light current rating 40 Amps, 220 Volts, 50 Hz. The sensor based timer should also have over voltage and low voltage trip with auto reset facility the sensor alongwith suitable power contactor, MCB and support terminals should be enclosed in pole/wall mountable enclosure made of rust proof electric shock proof termite proof and FR grade special moulding compounds confirming to IP 54. The contactor MCB and circuit wiring shall have enough capacity to take load of 12 KW equally distributed over 3 phase complete all as specified and as directed.
M&L in replacement for LED Light 400W of search light complete all as specified and as dirceted.
Supply and fixing in replacement LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as dirceted.
M&L for Four Pole onload Changeover 400 A with Advance Neutral Conforms to IS:13947 (Part-3); IEC:60947-3 complete all as specified and as dirceted.
S&F constant current led driver of existing street light model suitable for 30 watt LED street Light complete all as specified and as dirceted.
S&F constant current led driver model suitable for 45 watt LED street Light complete all as specified and as dirceted.
S&F constant current led driver model suitable for 72 watt LED street Light complete all as specified and as dirceted.
Supply and fixing in replacement LED Solar street light fitting 36 Watt including galvanized steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete all as specified and as dirceted. (Excavation & earth work shall be measured separately)
S&F Battery 30 AH, Cell inbuild Li-on batteries ,battery Type LifePO4,Batery Voltage 3.2 Volt, Suitable for Solar Light complete all as specified and as dirceted.
S&F PCB Card For 30 watt solar lights complete all as specified and as dirceted.
S&F Sensor For 30 watt solar lights complete all as specified and as dirceted.
S&F Solar photo voltic Panel For 30 watt solar lights complete all as specified and as dirceted.
"Taking down old UNSV fidder pillar and Supply, fixing, testing and commissioning in replacement of feeder pillar panel single door floor mounted and wall/pole mounted outdoor type, as per IP-55 grade, made out of MS sheet 3.15 mm thick of size 925x540x250mm with aluminium bus bar 650 Amps, 4 strip (3 phase) complete drilled, insulated with colour coded insulation tape, mounted on insulators etc with RYB indicator, panel should be dust proof, vermin proof, powder coated , locking should be screw type, mechanical type, inter locking with 650 Amps 25 KA MCCB four pole for incomer cable, should have danger notice for 415 volts, AC, mounted on 50x50x6 mm angle iron frame having minimum 2 feet ground clearance duly embedded in and including PCC block (1:2:4) complete including termination of all incoming and outgoing cables with suitable size thimbles/lugs and glands etc and providing fixing arrangements including earthing lead fixing arrangement, complete all as specified and as directed. Note :- Installation, testing, commissioning and connecting of incoming and outgoing cable connection LT feeder pillar panel shall included in rates quoted."
P R Constructions (BID ID -3145357)
D P ENTERPRISES (BID ID -3138504)
akhil enterprises (BID ID -3145173)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .