Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹10.6 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹12.3 L+₹64,794 (5.57%)Rejected-AOC AT GEETAGRAM PS ANGUL PO PTC ANGUL ANGUL ODISHA 759122 | ANUGUL | ODISHA | 759122 | L-2 | Rejected-AOC L-2 | |
| 3 | L-3₹15.0 L+₹3.4 L (29.3%)Rejected-AOC | L-3 | Rejected-AOC L-3 | |
| 4 | L-4₹15.4 L+₹3.7 L (32.0%)Rejected-AOC BANARPAL KULAD NALCO NAGAR NALCO NAGAR ANGUL ODISHA 759145 | ANUGUL | ODISHA | 759145 | L-4 | Rejected-AOC L-4 | |
| 5 | Not Admitted-Fee/PreQual/Technical/Finance NA NALCO NAGAR ANGUL ODISHA 759145 | ANUGUL | ODISHA | 759145 | - | Not Admitted-Fee/PreQual/Technical/Finance Price Bid not complied |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
9 Dec 2020, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Mr. Sunaram Hansdah, AGM (Met.)
TnC Department, Smelter Plant, NALCO, Angul, Odisha-759145
Electrification of New PTM Overhauling Shop at Potline-IV
2020_NALCO_594399_1
OMC-5290
Limited
Electrical Works
Item Rate
180 days
Smelter Plant, NALCO, Angul
5 documents required · 5 mandatory
₹0
₹10,000
Yes
27 Feb 2021
2 Nov 2020
11 Dec 2020
2 Nov 2020
9 Dec 2020
2 Nov 2020
120 days
Amount
Power supply of 415 V for office building : The job includes (1) Laying of PVC insulated AL unarmoured power cable of size 3.5*25 sqr mm from substation No - 41 to the new PM shop over existing cable tray including necessary clamping, tagging. The distance between the substation and PM shop is around 400 mtrs. (2) Termination shall be done at the both end cable i.e in the designated feeder inside substation and the Isolator installed in the office building of the PM shop. (3) The above activity pertains to Job only and all materials are in the scope of NALCO.
Power supply of 415V for EOT crane : : The job includes (1) Laying of PVC insulated AL unarmoured power cable of size 3.5*50 sqr mm from substation No -41 to the new PM shop over existing cable tray including necessary clamping, tagging. The distance between the substation and PM shop is around 400 mtrs. (2) Termination shall be done at the both end cable i.e designated feeder in substation and the Isolator installed at PM shop. (3) The above activity pertains to Job only and all materials are in the scope of NALCO.
Power supply of 415V for PSC : The job includes (1)Laying of PVC insulated AL unarmoured power cable of size 3.5*50 sqr mm from substation -41 to the new PM shop over existing cable tray including necessary clamping, tagging. The distance between the substation and PM shop is around 400 mtrs. (2) Termination shall be done at the designated feeder in substation and the power supply unit installed at PM shop. (3) The above activity pertains to Job only all materials are in the scope of NALCO
Extension of existing PTM power rail. The job includes (1) making one no web brackets/meter, made of 50*50*5mm MS angles of length 500mm and fixing in the structurer by welding. (2) Fixation of hanger clamps in the web bracket by making hole by drilling & bolting the web bracket. (3) Fixation of 800A, alignment of 3 phase M/S Wamfler bus bar , joint cover & end cover. (4) After complete installation, power feeding shall be done from the nearest LBS which is around 10mtrs with cable of 3*35sqr mm. (5) All joints and web brackets shall be painted with one coat primer and two coat of enamel paint(5) The unit length of one meter means one meter from each phases. All materials are in the scope of NALCO. The consumable like gas, welding rod for making the web bracket, Copper lugs etc has to be supplied by party.
Installation of Hi bay ROOF Light: The job includes (1) Marking the position of Roof light fitting in the roof/beam jointly with EIC. (2) Installation of 4 inch * 4 inch GI JB box near the light fixture in the beam for termination of 3*2.5 sqr cable required for light. (3) Lying the cable in the existing tray & termination of cable in the GI box and the lighting distribution board in the floor level. (4) Cable length from lighting distribution box to lighting JB is around 25 mtr. (5) Installation the 150W LED light fittings & cable termination shall be done (4) The above mentioned activity pertains to job only and all materials are in the scope of NALCO.
Lighting distribution board: The job includes (1) Installation, commissioning and testing of 63A Lighting distribution board inside office building with termination of one no incoming cable of 3.5* 25 sqr mm Al and 16 nos 3*2.5 sqr mm outgoing cable as per the instruction of EIC. (2) The above activity pertains to Job only & the supply of lighting distribution board has been mentioned at Sl no-18 of BOQ.
Power distribution board for air conditioner and PSC: (1) The job includes Installation, commissioning and testing of Power distribution cabinet inside the office building with termination of one no incoming cable of 3.5* 35 sqr mm Al and 12 nos 3*2.5 sqr mm outgoing cable as per the instruction of EIC.(2) The above activity pertains to Job only & the supply of power distribution board has been mentioned at Sl no-19 of BOQ.
Making of T Joint for connection in PSC : (1) The job includes making of mould type T joint .The incoming and outgoing cable size is 3* 50 sqr mm. (2) The above activity pertains to Job only & the supply of T joint, mould and other accessories has been mentioned at Sl no-17 of BOQ.
Making of Chemical earth/maintenance free earth pit. The job includes (1) Braking /Dismantling the top layer concrete surface of 200 mm thickness & the excavation of a pit of minimum dimensions of 500 mm (L) x 500 mm (W) x 3000 mm (D) in any type of soil in the designated place as identified by EIC. (2) Making of earth pit chamber with necessary earth work and installation of earth electrode, Refilling with earth and earth enhancing compound materials, box up with Inspection chamber, connecting earth strip with GI nut bolts, masonry works, marking as per IS-3043:1987 and as required as per direction of Engineer-In-Charge. NALCO. Inspection chamber shall made with heavy duty FRP and locking arrangement trough stainless steel nut bolt/screws. The details of measurement i.e earth resistance value and latest testing date and previous recorded values shall be displayed near to the earth pit. (4) The above activity pertains to Job only & all materials are in the scope of NALCO
All electrical Panel and equipment' earthing: The job includes laying and clamping of 2 nos GI earth strip of minimum size 25x3mm thickness from the newly made earth pit to the various electrical panels. Apply black paint in the welding portion. The above activity pertains to Job only & the supply part has been mentioned at Sl no-20 of BOQ.
Fabrication of structurer & Installation of cable tray (600mm). The job includes (1) Grouting/welding 14 nos MS channels of size 100x50x5 mm and length around 700mm in the existing beam for support. (2) Fixing of another channel of size 100x50x5 mm by welding with support channel at sl no-1 and horizontal length is approximately 70 meter (3) Making the cable tray support of 650mm length in MS angle 50X50x6mm and to be welded with the horizontal channel at Sl no-2 at an interval of 1 meter (4) The support structurer, channels and welding joints shall be painted with one coat primer and two coats of paint.(5) Installation of GI cable tray of width 600 mm and clamping with the support structurer as instructed by EIC (6) Cable Tray shall be supplied by NALCO(7)All other consumables like ,nut, bolts(for connecting the cable tray), welding rods, cutting tools etc for erection of cable tray are in party#s scope. The supply of MS angle, channels has been mentioned at Sl no- 26, 27 of BOQ. Note: The tray erection shall be done at a height of around 4 meters from floor level. Requirement of Scaffolding/vehicle is in party#s scope.
Installation of cable tray (150mm) for lighting in the shop. The job includes (1) installation of cable tray of width 150mm and clamping with existing structurer/wall inside the shop floor as instructed by EIC (2)Painting all the joints/welding parts.(3) The above activity pertains to Job only & the supply of cable tray has been mentioned at Sl no-22 of BOQ. (3)All other consumables like, nut, bolts (for connecting the cable tray), clamping materials etc for erection of cable tray is in party#s scope.
Installation of PSC :The job include(1) Making a base frame in MS angle 2ft* 2ft ,applying one coat primer, two coats of enamel paint and fixing in the wall (2) Installation of Power supply cabinet(PSC) of approximately size 600*600mm of stainless steel material on the base frame (3) Glanding, cable termination of the incoming cable of size of 3.5 *50 sqr mm Al shall be made inside the PSC. (4) The above activity pertains to Job only & the PSC shall be supplied by NALCO. (5) All other consumables like welding rods, cutting tools etc for installation are in party#s scope.
Wiring in 4 sqr mm copper wire : The job includes wiring and connection of electrical equipments like switches, tube lights, ceiling fans, Exhaust fans, air conditioners, computer power & other electrical appliance etc in the existing concealed pipe with 4 sqr mm copper wire and as instructed by EIC.The supply of materials has been mentioned in at Sl no- 24 of BOQ.
Wiring in 2.5 sqr mm copper wire: The job includes wiring and connection of electrical equipments like switches, tube lights, ceiling fans, Exhaust fans, air conditioners, computer power & other electrical appliance etc in the existing concealed pipe with 2.5 sqr mm copper wire and as instructed by EIC.The supply of materials has been mentioned in at Sl no-23 of BOQ.
Installation of LBS for crane power. The job includes installation of load break switch of 125A of stainless steel material in the wall/column. The termination of the incoming cable of size 3.5 *50 sqr mm Al shall be done. All material shall be supplied by NALCO.
Supply of mould type T joint, suitable for 3*50sqr mm Al cable with all accessories, make -reputed.
Supply of LDB, 63A ,4 pole ,100mA RCCB and 63A 4 pole MCB, Single door type and 16 out going feeders with 16 nos 20A MCBs,CRCA sheet steel,IP 54 protection,conforms to IS 8623,Make:HPL/Indo Asian/ L&T/Havells/legrand
Supply of auxiliary power DB,100A ,4 pole,100mA RCCB and 100A 4 pole MCB and 12 outgoing feeders with 12 nos 16A ,MCBs,single door,CRCA sheet steel, IP 54 protection, conforms to IS 8623 type, Make:HPL/Indo Asian/L&T/Havells/Legrand
Supply of GI Earth strip of size 25x3mm ,clamping materials.
Supply of modular switch board cover with 8 nos 6A switch and one no 6A three pin socket,make Havells/Anchor/crabtree/Cona.
Supply of GI hot dip perforated rectangular GI cable tray of width 150mm,height 25mm ,thickness minimum 1.6mm with cover and joints, nuts, bolts,accessories for clamping, jointing nut ,bolts etc
Supply of wires,2.5 sqr mm,single core PVC, Make: Havells/Anchor/finolex.
Supply of wires,4 sqr mm,single core PVC,Make: Havells/Anchor/Finolex.
Supply of ceiling rose,white,65mm dia,Make:reputed.
Supply of MS channel of size 100X50X5mm, Conforming to IS:2062-2011,Grade designation: E250, Quality-A, Minimum length of 10 meters.
Supply of MS angle 50x50x5mm,with designation E-250 grade ,quality-A as per IS 2026: 2006 or latest with minimum length of 5 to 6 mtr.
4*4 GI JB box for lighting,make: Havells/hensel/cape/anchor/reputed
Supply of lugs, glands (1) lugs size:50mm sqr, copper, tube type 100Nos(2)lugs size:35mm sqr copper, tube type-50Nos (3) lugs size:4mm sqr copper, pin type -100Nos(4) lugs size:4mm sqr, copper, tube type 100Nos(5) brass gland 12 nos suitable for glanding 3.5*50sqr mm AL cable.
M/S B & J ELECTRICALS
POWER LINKS
M/s. Unitech Power Engineering & Co.
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.PDF
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .