| 1 | L1₹4.4 LQualified Make: Kirloskar
Model: kirlosker DG25KVA NA NIRMALA APARTMENT S C ROAD ATHGAON GUWAHATI KAMRUP ASSAM 781001 | KAMRUP METRO | ASSAM | 781001 | Make: Kirloskar
Model: kirlosker DG25KVA | L1 | Qualified | |
| 2 | L2₹4.8 L+₹38,179 (8.64%)Qualified Make: MAHINDRA POWEROL
Model: MAHINDRA 3385TCIGM-C2 0 INDIRA PALLY INDIRA PALLY BANKRA BANKRA HOWRAH WEST BENGAL 711403 | HOWRAH | WEST BENGAL | 711403 | Make: MAHINDRA POWEROL
Model: MAHINDRA 3385TCIGM-C2 | L2 | Qualified | |
| 3 | Disqualified Make: KOEL GREEN
Model: KOEL GREEN HA-494TCIG1 A 8 MANGALDIP APPARTMENT SAIJPUR BOGHA NARODA ROAD AHMEDABAD GUJARAT 382345 | AHMADABAD | GUJARAT | 382345 | Make: KOEL GREEN
Model: KOEL GREEN HA-494TCIG1 | - | Disqualified | |
| 4 | Disqualified Make: KOHLER
Model: KOHLER-KDG0025P1 | Make: KOHLER
Model: KOHLER-KDG0025P1 | - | Disqualified | |
| 5 | Disqualified Make: MAHINDRA GSP RETAIL
Model: MAHINDRA 3335TC GM2 22 IIIRD FLOOR MAIN MARKET MOTI NAGAR DELHI DELHI 110015 | WEST DELHI | DELHI | 110015 | Make: MAHINDRA GSP RETAIL
Model: MAHINDRA 3335TC GM2 | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
10 Sept 2018, 1:00 pmClosed
diesel generators- DG Sets Diesel Generators- DG Sets ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 25 * (or higher) No of Phase - Single phase
Three Phase ENGINE Make of Engine - * Model Number of Engine - * Capacity of Engine (cc) - * Engine Power (kWm) - * ISI Marking to IS :10001 for engine false * BIS license No
if applicable - * Type of Engine cooling Liquid Cooled Air Cooled
Liquid Cooled Type of governer Electronic Mechanical
Electronic (or higher) Class of governer A1 A0
A1
A2 1/4 (or higher) Number of cylinders (nos) 3 * No of Strokes (nos) 4 * Rated RPM of Engine (RPM) - 1500
3000 Overload capacity for one hour for every 11 hours continuous running at full load (%) 10 * Specific Fuel Consumption (gm/kWh) - * Starting voltage (volt) 12 * ALTERNATOR AC GENERATOR(ALTER NATOR) Make - * AC GENERATOR(ALTER NATOR) model Number - * Rating of AC Generator (KVA) 25 * Power Factor of AC generator 0.8 * Efficiency at rated Power factor at 75% of full Load 76.73 * Compliance of Alternator to IS:13364(part-1) Yes * Type of alternator Brushless * Voltage Regulation Grade VG 3 * Alternator IP Rating IP 23 * Class of Insulation H * CONTROL PANEL Control Panel Manual Manual
AMF IP Rating of Control Panel IP 53 * ACOUSTIC ENCLOSURE Sheet Thickness 1.6 1.6
1.8
2
1.2 (or higher) Thickness of Foam 25 * Density of Foam for sound insulation 28 * Noise level at 1 meter (dB) 75 * BATTERY Battery Type & Specification Low Maintenance free to IS: 14257 for high cranking performance * 2/4 Battery capacity (Ah) - * No of batteries 1 * TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes * Test Report number and date(Engine) - * Name and address of laboratory(Engine) - * Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes * Test Report number and date(Alternator) - * Name and address of laboratory(Alternator) - * DG set meet requirements of Enviro nmental(Protection) Rules 1986
in respect of noise and emission norms
as described in STC Yes * WARRANTY INSTALLATION & COMMISSIONING Warranty 2 Any applicable numeric value Installation & Commissioning With Installation With Installation
Without Installation Agreed to STC of the Product Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 SORABH PANDEY 790104
O/O The Commandant
38th Bn SSB Tawang
PO. Tawang 1 15
568044
GEM/2018/B/80583
diesel generators- DG Sets
15 days
Arunachal Pradesh; Tawang
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| diesel generators- DG Sets Diesel Generators- DG Sets ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 25 * (or higher) No of Phase - Single phase | - | - | - |
| Three Phase ENGINE Make of Engine - * Model Number of Engine - * Capacity of Engine (cc) - * Engine Power (kWm) - * ISI Marking to IS :10001 for engine false * BIS license No | - | - | - |
| if applicable - * Type of Engine cooling Liquid Cooled Air Cooled | - | - | - |
| Liquid Cooled Type of governer Electronic Mechanical | - | - | - |
| Electronic (or higher) Class of governer A1 A0 | - | - | - |
| A1 | - | - | - |
| A2 1/4 (or higher) Number of cylinders (nos) 3 * No of Strokes (nos) 4 * Rated RPM of Engine (RPM) - 1500 | - | - | - |
| 3000 Overload capacity for one hour for every 11 hours continuous running at full load (%) 10 * Specific Fuel Consumption (gm/kWh) - * Starting voltage (volt) 12 * ALTERNATOR AC GENERATOR(ALTER NATOR) Make - * AC GENERATOR(ALTER NATOR) model Number - * Rating of AC Generator (KVA) 25 * Power Factor of AC generator 0.8 * Efficiency at rated Power factor at 75% of full Load 76.73 * Compliance of Alternator to IS:13364(part-1) Yes * Type of alternator Brushless * Voltage Regulation Grade VG 3 * Alternator IP Rating IP 23 * Class of Insulation H * CONTROL PANEL Control Panel Manual Manual | - | - | - |
| AMF IP Rating of Control Panel IP 53 * ACOUSTIC ENCLOSURE Sheet Thickness 1.6 1.6 | - | - | - |
| 1.8 | - | - | - |
| 2 | - | - | - |
| 1.2 (or higher) Thickness of Foam 25 * Density of Foam for sound insulation 28 * Noise level at 1 meter (dB) 75 * BATTERY Battery Type & Specification Low Maintenance free to IS: 14257 for high cranking performance * 2/4 Battery capacity (Ah) - * No of batteries 1 * TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes * Test Report number and date(Engine) - * Name and address of laboratory(Engine) - * Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes * Test Report number and date(Alternator) - * Name and address of laboratory(Alternator) - * DG set meet requirements of Enviro nmental(Protection) Rules 1986 | - | - | - |
| in respect of noise and emission norms | - | - | - |
| as described in STC Yes * WARRANTY INSTALLATION & COMMISSIONING Warranty 2 Any applicable numeric value Installation & Commissioning With Installation With Installation | - | - | - |
| Without Installation Agreed to STC of the Product Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 SORABH PANDEY 790104 | - | - | - |
| O/O The Commandant | - | - | - |
| 38th Bn SSB Tawang | - | - | - |
| PO. Tawang 1 15 | - | - | - |
Exempted
10 Sept 2018
6 Sept 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_568044.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .