Loading…
Loading…
Tender Value
₹39.7 L
EMD Value
₹79,500
Closing Date
9 Oct 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
66 days
Expenditure
Capital (Works)
WORKS
12 conditions · 9 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
1) Tenderer should attach self attested copy of PAN CARD and photo identification in support of their Identity. 2) The documents attached to the tender document should be clear and legible for evaluation of tenders. Proper care to be taken in this regard
A copy of document to be uploaded containing the following details: Name of the tenderer/ contractor, Validity of DSC, Complete address with pincode, Contact No.
Scanned copy of PAN card has to be enclosed
Scanned copy of TIN card has to be enclosed
A copy of NEFT form duly filled in the details as necessary along with a cancelled Cheque to be uploaded. (The tenderer/ contractor not having NEFT form may down load the empty NEFT form available in documents site)
Information/ certificates required as per Tender document for partnership deed, Article of association, MOU, JV AGREEMENT, Proprietary firm etc.
Self Attested copy of Experience Certificate of Previous Work Done -The bidder should submit documents related to completed/on-going similar service contracts during the last three previous financial years and the current financial year along with the details of payments received and percentage penalties imposed therein, to classify the completed/ on-going similar service contracts.
For materials of purchase value Rs.5 lakhs and above, inspection shall be done by third party i.e. M/s. RITES and all expenditure in connection with the inspection shall be borne by thetenderer/Contractor (5) For ISI marked products, if the order is placed on ISI certified manufacturers, the materials can be accepted on firm's WTC
Improvements of platforms at JTJ(NSG 3) station in ADEN/JTJ sub division-Electrical arrangements thereof
ME-29-II-1106-2026~SR
ME-29-II-1106-2026
Open
Works - General
120 Days
Chennai, Tamil Nadu
₹0
₹79,500
17 Sept 2026
17 Sept 2026
25 Sept 2026
96 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 39,72,491 | ||
| — | — | — | Above/ 121880.00 Below/P | ||
| Demolishing plain cement concrete in platform or elsewhere, disposal of material atleast 6m away from track centre withinrailway land by saw cutting/breaker as per site conditions to avoid any damage to nearby site complete in a manner as directed by the Section Engineer incharge at site. | — | 220.00 | — | — | |
| — | — | — | Above/ 1176340.00 Below/P | ||
| Supply and provision of mass concrete for platforms or elsewhere with 1:2:4 ratio using 20mm graded blue metal complete in a manner as directed by the Section Engineer in charge at site.NOTE: i)Cement shall be Ordinary Portland Cement, 43 grade, conforming to IS: 456 or latest.ii)Proper compaction of cement concrete shall be ensured as per standard industrial practices.iii)The finished level should match with surface level properly | — | 220.00 | — | — | |
| — | — | — | Above/ 20500.00 Below/P | ||
| Laying/leading of 4 core 95 sq.mm LTUGAluminium cable in the excavated trench,threading through pipe, clamping on wallsand terminating in as many ends usingsuitable single compression cable glands,lugs , sockets and other items requiredcomplete as per site conditions in a mannercomplete as directed by Section Engineer incharge at site.Note:- 4Cx95 sq.mm LTUGAluminium Cable alone will be supplieddepartmentally. | — | 500.00 | — | — | |
| — | — | — | Above/ 40000.00 Below/P | ||
| Laying/leading of 4 core 70 sq.mm LTUGAluminium cable in the excavated trench,threading through pipe, clamping on wallsand terminating in as many ends usingsuitable single compression cable glands,lugs , sockets and other items requiredcomplete as per site conditions in a mannercomplete as directed by Section Engineer incharge at site.Note:- 4Cx70 sq.mm LTUGAluminium Cable alone will be supplieddepartmentally. | — | 1000.00 | — | — | |
| — | — | — | Above/ 60000.00 Below/P | ||
| Laying/leading of 4 core 35 sq.mm LTUGAluminium cable in the excavated trench,threading through pipe, clamping on wallsand terminating in as many ends usingsuitable single compression cable glands,lugs , sockets and other items requiredcomplete as per site conditions in a mannercomplete as directed by Section Engineer incharge at site.Note:- 4Cx35 sq.mm LTUGAluminium Cable alone will be supplieddepartmentally. | — | 2000.00 | — | — | |
| — | — | — | Above/ 120000.00 Below/P | ||
| Laying/leading of 4 core 25 sq.mm LTUGAluminium cable in the excavated trench,threading through pipe, clamping on wallsand terminating in as many ends usingsuitable single compression cable glands,lugs , sockets and other items requiredcomplete as per site conditions in a mannercomplete as directed by Section Engineer incharge at site.Note:- 4Cx25 sq.mm LTUGAluminium Cable alone will be supplieddepartmentally. | — | 5000.00 | — | — | |
| — | — | — | Above/ 26500.00 Below/P | ||
| Laying/leading of 4 core 240 sq.mm LTUGAluminium cable in the excavated trench,threading through pipe, clamping on wallsand terminating in as many ends usingsuitable single compression cable glands,lugs , sockets and other items requiredcomplete as per site conditions in a mannercomplete as directed by Section Engineer incharge at site.Note:- 4Cx240 sq.mm LTUGAluminium Cable alone will be supplieddepartmentally. | — | 500.00 | — | — | |
| — | — | — | Above/ 29000.00 Below/P | ||
| Laying of 63 mm dia High DensityPolyethylene pipes in the excavated trench,clamping on walls / Steel members ofplatform shelter or elsewhere using suitableGI fixing arrangements and couplers andother accessories required at appropriatelocations as per site conditions so that cablecan be easily inserted and removedwherever need arises complete in amanner as directed by Senior SectionEngineer-in-charge at site.Note: 63mm dia HDPE pipe alone will besupplied departmentally. | — | 1000.00 | — | — | |
| — | — | — | Above/ 196000.00 Below/P | ||
| Laying of 50 mm dia High DensityPolyethylene pipes in the excavated trench,clamping on walls / Steel members ofplatform shelter or elsewhere using suitableGI fixing arrangements and couplers andother accessories required at appropriatelocations as per site conditions so that cablecan be easily inserted and removedwherever need arises complete in amanner as directed by Senior SectionEngineer-in-charge at site.Note: 50mm dia HDPE pipe alone will besupplied departmentally. | — | 7000.00 | — | — | |
| — | — | — | Above/ 20500.00 Below/P | ||
| Laying of 110 mm dia High DensityPolyethylene pipes in the excavated trench,clamping on walls / Steel members ofplatform shelter or elsewhere using suitableGI fixing arrangements and couplers andother accessories required at appropriatelocations as per site conditions so that cablecan be easily inserted and removedwherever need arises complete in amanner as directed by Senior SectionEngineer-in-charge at site.Note: 110mm dia HDPE pipe alone will besupplied departmentally. | — | 500.00 | — | — | |
| — | — | — | Above/ 78400.00 Below/P | ||
| Installation, Testing and commissioning of 4feet 30W LED light fitting Batten type suitableto work on 240V single phase 50 Hz AC withlamp and all standard accessories usingsuitable mounting and fixing arrangement asper industrial practices including supplyconnection from ceiling rose by using 3 core1.5 sq. mm Fire Retardant Low Smoke PVCinsulated, PVC round sheathed copper[White/Ivory colour] conductor flexiblependant chord conforming to IS:694/1990 orlatest complete as per industrial standardsand in a manner as directed by SeniorSection Engineer in charge at site.Note: 4 feet LED 30W light fitting BattenType with lamp alone will be suppliedDepartmentally | — | 800.00 | — | — | |
| — | — | — | Above/ 31350.00 Below/P | ||
| Installation, Testing and commissioning of1200mm sweep BLDC ceiling fan onto thebuildings or elsewhere using suitableclamping and fixing arrangement completeas per industrial practices including supplyconnection from ceiling rose by using 3 core1.5 sq. mm fire retardant Low smoke PVCinsulated, PVC round sheathed copper[White / Ivory colour] conductor flexiblependant chord conforming to IS:694/1990 orlatest complete in a manner as directed bySenior Section Engineer in charge at site.Note: 1200mm sweep BLDC Ceiling fanalone will be supplied departmentally. | — | 150.00 | — | — | |
| — | — | — | Above/ 20925.00 Below/P | ||
| Installation, Testing and commissioning of100 W LED Flood light fittings using suitableGI tubular mounting arm bent to act astubular support for anchoring arrangementonto walls including supply connection fromceiling rose/junction box or elsewhere byusing 3 core 1.5 sq. mm Fire retardant lowsmoke PVC insulated ,PVC round sheathedcopper[White/Ivory colour] conductor flexiblechord conforming to IS:694/1990 or latest asper industrial standards in a manner asdirected by Section Engineer in charge atsite.Note: 100W LED Flood light fittings alonewill be supplied departmentally | — | 45.00 | — | — | |
| — | — | — | Above/ 62500.00 Below/P | ||
| Installation, Testing and commissioning ofSMC box assembly similar to SintexCatalogue reference No.GSJB- 1414 alongwith strip connector block, Neutral link, fusebases and carriers onto lamp posts orelsewhere suing suitable clampingarrangements complete and in a manner asdirected by Section Engineer incharge at siteNote: SMC GSJB-1414 box, stripconnector , neutral link, Earth link,Fuse bases and fuse carriers, MSclamping arrangements alone will besupplied Departmentally. | — | 500.00 | — | — | |
| — | — | — | Above/ 251000.00 Below/P | ||
| Supply and stringing of overhead mainsbeneath platform shelters using 5 runs of 16sq.mm PVC insulated and PVC sheathedmulti stranded aluminium conductor cableduly by binding onto insulators of bracketsprovided vide item No. 16 below complete ina manner as directed by Section Engineer incharge at Site.Note: 1)5 runs of16 sq.mm cable are takenas 1m for unit purpose.2)The earth wire should be lugged at bothends and has to be terminated in each MSclamp through Nuts and Bolts. | — | 1000.00 | — | — | |
| — | — | — | Above/ 122800.00 Below/P | ||
| Supply and fixing of MS brackets, fabricatedas per sketch enclosed, for supporting OHwire beneath platform shelters, mounted with4 Nos. of porcelain vertical reel /shackleinsulators and earth stud /bolt, finished with2 coats of red primer and 1 coat of aluminiumpaint and complete with fixing arrangementsas per drawing enclosed and in a manner asdirected by Section Engineer in charges atsite | — | 200.00 | — | — | |
| — | — | — | Above/ 308320.00 Below/P | ||
| Erection, testing and commissioning of 4meter single arm octagonal pole assemblyonto the suitable RCC foundation and copingby using modern engineering practiceincluding installation, testing andcommissioning of LED luminaries includingall wiring works from nearby junction box asper industrial standards complete in amanner as directed by Section Engineer incharge at site.Note: 1) The foundation design anddrawing along with supporting ISspecifications suitable for Octagonalpoles supplied by Railways and as persite conditions should be submitted forapproval before starting the work2) Four metre single arm Octagonal poleand accessories along with luminariesalone will be supplied departmentally. | — | 80.00 | — | — | |
| — | — | — | Above/ 40640.00 Below/P | ||
| Installation, Testing and commissioning of70W LED street fittings using suitable GItubular mounting arm bent to act as tubularsupport for anchoring arrangement ontowalls including supply connection fromceiling rose/junction box or elsewhere byusing 3 core 1.5 sq. mm Fire retardant lowsmoke PVC insulated, PVC round sheathedcopper [White/Ivory colour] conductorflexible chord conforming to IS:694/1990 orlatest as per industrial standards in a manneras directed by Section Engineer in charge atsite.Note: 70W LED street light fittings alonewill be supplied departmentally. | — | 160.00 | — | — | |
| — | — | — | Above/ 75000.00 Below/P | ||
| Installation, Testing and Commissioning ofthe LT Earthling arrangements duly byexcavating/ auguring of earth pit in all kindsof soil/concrete surface or elsewhere,construction of masonry earth pit enclosure,provision of cover etc, complete includingsupply / leading / laying / burying andconcealing of GI strip 32 X 6 mm along withproper sleeve from earth electrode toproposed MDB / SDB or elsewhere and in amanner as directed by Senior SectionEngineer in chargeat site.Note:1) Masonry earth pit enclosure and covershall be as per drawing numberEL/P/TYPE/1022.2) LT Earthling Electrode alone will besupplied Departmentally. | — | 50.00 | — | — | |
| — | — | — | Above/ 96000.00 Below/P | ||
| Supply and drawing of inside mains using 2runs of 2.5 sq. mm [from MCB DB to switchboards and from switch boards to switchboards or elsewhere] Fire Retardant LowSmoke PVC insulated unsheathed multistrandedcopper conductor cables of 1100Vgrade [conforming to IS:694/1990 or latest]duly inside the PVC conduit concealed/laidvide item No:26 below complete as per thespecification enclosed and in a manner asdirected by Section Engineer in charge atsite.Note: - 2 runs of 2.5 sq. mm copperconductor are taken as 1m for quantitypurpose. | — | 1000.00 | — | — | |
| — | — | — | Above/ 115000.00 Below/P | ||
| Supply and Drawing of earth wire using 1.5sq.mm Fire Retardant Low Smoke PVCinsulated unsheathed multi-stranded copperconductor cables of 1100V grade[conforming to IS:694/1990 or latest] dulyalong wires vide item No 22 below and lightand fan points vide item No.35,36, and 37below or elsewhere complete in a manner asdirected by Senior Section Engineer incharge at site. | — | 5000.00 | — | — | |
| — | — | — | Above/ 104000.00 Below/P | ||
| Supply and drawing of inside mains using 2runs of 4 sq. mm [from MCB DB to switchboards and from switch boards to switchboards or elsewhere] Fire Retardant LowSmoke PVC insulated unsheathed multistrandedcopper conductor cables of 1100Vgrade [conforming to IS:694/1990 or latest]duly inside the PVC conduit concealed/laidvide item No:26 below complete as per thespecification enclosed and in a manner asdirected by Section Engineer in charge atsite.Note: - 2 runs of 4 sq. mm copperconductor are taken as 1m for quantitypurpose. | — | 1000.00 | — | — | |
| — | — | — | Above/ 91500.00 Below/P | ||
| Supply and drawing of inside mains using 3runs of 6 sq. mm [from MCB DB to switchboards and from switch boards to switchboards or elsewhere] Fire Retardant LowSmoke PVC insulated unsheathed multistrandedcopper conductor cables of 1100Vgrade [conforming to IS:694/1990 or latest]duly inside the PVC conduit concealed/laidvide item No:26 below complete as per thespecification enclosed and in a manner asdirected by Section Engineer in charge atsite.Note: - 3 runs of 6 sq. mm copperconductor are taken as 1m for quantitypurpose. | — | 500.00 | — | — | |
| — | — | — | Above/ 159000.00 Below/P | ||
| Supply and drawing of inside mains using 4runs of 10 sq. mm [from MCB DB to switchboards and from switch boards to switchboards or elsewhere] Fire Retardant LowSmoke PVC insulated unsheathed multistrandedcopper conductor cables of 1100Vgrade [conforming to IS:694/1990 or latest]duly inside the PVC conduit concealed/laidvide item No:27 below complete as per thespecification enclosed and in a manner asdirected by Section Engineer in charge atsite.Note: - 4 runs of 10 sq. mm copperconductor are taken as 1m for quantitypurpose. | — | 300.00 | — | — | |
| — | — | — | Above/ 3700.00 Below/P | ||
| Installation, Testing and commissioning ofthe 300mm sweep BLDC Exhaust fan ontothe buildings or elsewhere using suitableclamping and fixing arrangement completeas per industrial practices including supplyconnection from ceiling rose by using 3 core1.5 sq. mm fire retardant Low smoke PVCinsulated, PVC round sheathed copper[White / Ivory colour] conductor flexiblependant chord conforming to IS:694/1990 orlatest complete as per industrial standardsand in a manner as directed by SeniorSection Engineer in charge at site.Note: 300mm sweep BLDC Exhaust fanalone will be supplied departmentally. | — | 20.00 | — | — | |
| — | — | — | Above/ 177000.00 Below/P | ||
| Supply and Concealing of 25mm dia rigidPVC conduits [IVORY colour] conforming toIS:9537 Part3(2021) or latest[ISI marked]with wall thickness not less than 2mm alongwith Bends, Junction Boxes and other itemsrequired along with manpower as per siteconditions complete including cutting/chipping the wall/ceiling or elsewhere andmaking good the same including replasteringand painting wall to original condition/clamped at regular intervals, not exceeding500 mm in a manner as directed by SectionEngineer in charge at site as per industrialstandards and as per specification for wiring/rewiring enclosed. [Approximate length ofPVC conduit] | — | 3000.00 | — | — | |
| — | — | — | Above/ 54530.00 Below/P | ||
| Supply and Concealing of 32mm dia rigidPVC conduits [IVORY colour] conforming toIS:9537 Part3(2021) or latest [ISI marked]with wall thickness not less than 2mm alongwith Bends, Junction Boxes and other itemsrequired along with manpower as per siteconditions complete including cutting/chipping the wall/ceiling or elsewhere andmaking good the same including replasteringand painting wall to original condition/clamped at regular intervals, not exceeding500 mm in a manner as directed by SectionEngineer in charge at site as per industrialstandards and as per specification for wiring/rewiring enclosed. [Approximate length ofPVC conduit] | — | 410.00 | — | — | |
| — | — | — | Above/ 2700.00 Below/P | ||
| Supply of 2Way PVC Junction Boxconforming to IS: 3419 or latest ,minimumwall thickness not less than 2mm in amanner as directed by Section Engineerincharge at site. | — | 100.00 | — | — | |
| — | — | — | Above/ 2600.00 Below/P | ||
| Supply of 3Way PVC Junction Boxconforming to IS: 3419 or latest ,minimumwall thickness not less than 2mm in amanner as directed by Section Engineerincharge at site. | — | 100.00 | — | — | |
| — | — | — | Above/ 2900.00 Below/P | ||
| Supply of 4Way PVC Junction Boxconforming to IS: 3419 or latest ,minimumwall thickness not less than 2mm in amanner as directed by Section Engineerincharge at site. | — | 100.00 | — | — | |
| — | — | — | Above/ 45080.00 Below/P | ||
| Supply of modular frame plate with matchingcover plate suitable for 12 modules dulyaccommodated onto suitable modular switchboard box made of 1.2mm thick GI Sheetcomplete with 16A SP MCB and recessmounting/ concealing the same onto the wallusing suitable fixing arrangements includingcutting/ chipping/ making recess on the wallor elsewhere and painting etc., completeincluding fixing ,testing and commissioningof Switches and sockets supplied in abovearrangements including all internal wiringconnections in a suitable manner as directedby Section engineer in charge at site.Note: -i)1 No. 12 Module frame plate with matchingcover plate and 1 No. Modular GI box aretaken as 1 No for quantity purpose andshould match with IS codes with latestamendments.ii) Note: MCBs shall be of conforming to IS:8828/1996 or latest with rated short circultcapacity of 10kA | — | 70.00 | — | — | |
| — | — | — | Above/ 21500.00 Below/P | ||
| Supply of modular frame plate with matchingcover plate suitable for 8 modules dulyaccommodated onto suitable modular switchboard box made of 1.2mm thick GI Sheetcomplete with 16A SP MCB and recessmounting/ concealing the same onto the wallusing suitable fixing arrangements includingcutting/ chipping/ making recess on the wallor elsewhere and painting etc., completeincluding fixing ,testing and commissioningof Switches and sockets supplied in abovearrangements including all internal wiringconnections in a suitable manner as directedby Section engineer in charge at site.Note: -i)1 No. 8 Module frame plate with matchingcover plate and 1 No. Modular GI box aretaken as 1 No for quantity purpose andshould match with IS codes with latestamendments.ii) Note: MCBs shall be of conforming to IS:8828/1996 or latest with rated short circultcapacity of 10kA | — | 50.00 | — | — | |
| — | — | — | Above/ 20450.00 Below/P | ||
| Supply of modular frame plate with matchingcover plate suitable for 6 modules dulyaccommodated onto suitable modular switchboard box made of 1.2mm thick GI Sheetcomplete with 16A SP MCB and recessmounting/ concealing the same onto the wallusing suitable fixing arrangements includingcutting/ chipping/ making recess on the wallor elsewhere and painting etc., completeincluding fixing ,testing and commissioningof Switches and sockets supplied in abovearrangements including all internal wiringconnections in a suitable manner as directedby Section engineer in charge at site.Note: -i)1 No. 6 Module frame plate with matchingcover plate and 1 No. Modular GI box aretaken as 1 No for quantity purpose andshould match with IS codes with latestamendments.ii) Note: MCBs shall be of conforming to IS:8828/1996 or latest with rated short circultcapacity of 10kA | — | 50.00 | — | — | |
| — | — | — | Above/ 15900.00 Below/P | ||
| Supply of modular frame plate with matchingcover plate suitable for 4 modules dulyaccommodated onto suitable modular switchboard box made of 1.2mm thick GI Sheetcomplete with 16A SP MCB and recessmounting/ concealing the same onto the wallusing suitable fixing arrangements includingcutting/ chipping/ making recess on the wallor elsewhere and painting etc., completeincluding fixing ,testing and commissioningof Switches and sockets supplied in abovearrangements including all internal wiringconnections in a suitable manner as directedby Section engineer in charge at site.Note: -i)1 No. 4 Module frame plate with matchingcover plate and 1 No. Modular GI box aretaken as 1 No for quantity purpose andshould match with IS codes with latestamendments.ii) Note: MCBs shall be of conforming to IS:8828/1996 or latest with rated short circuitcapacity of 10kA | — | 60.00 | — | — | |
| — | — | — | Above/ 19250.00 Below/P | ||
| Wiring to light, fan, exhaust fan points [Shortpoint i.e. length upto 3 mtr] by supply anddrawing of 2 runs of 1.5 sq. mm FireRetardant Low Smoke PVC insulated coppermulti-stranded copper cables of 1100 Vgrade [conforming to IS: 694/1990 or latest]duly inside the PVC conduit concealed videitem No. 26 above complete with provision of6A Modular switch conforming to IS:3854/2023 or latest, 1 No. 3 plate ceiling roseconforming to IS: 371/1999 or latest and withall standard accessories complete and in amanner as directed by Section Engineer incharge at site. | — | 110.00 | — | — | |
| — | — | — | Above/ 58200.00 Below/P | ||
| Wiring to light, fan, exhaust fan points[Medium point i.e. length between 3 to 6 mtr]by supply and drawing of 2 runs of 1.5 sq.mm Fire Retardant Low Smoke PVCinsulated copper multi-stranded coppercables of 1100 V grade [conforming to IS:694/1990 or latest] duly inside the PVCconduit concealed vide item No. 26 abovecomplete with provision of 6A Modular switchconforming to IS: 3854/2023 or latest, 1 No.3 plate ceiling rose conforming to IS:371/1999 or latest and with all standardaccessories complete and in a manner asdirected by Section Engineer in charge atsite. | — | 200.00 | — | — | |
| — | — | — | Above/ 110100.00 Below/P | ||
| Wiring to light, fan, exhaust fan points [Longpoint i.e. length between 6 to 9 mtr] by supplyand drawing of 2 runs of 1.5 sq. mm FireRetardant Low Smoke PVC insulated coppermulti stranded copper cables of 1100 Vgrade [conforming to IS: 694/1990 or latest]duly inside the PVC conduit concealed videitem No. 26 above complete with provision of6A Modular switch conforming to IS:3854/2023 or latest, 1 No. 3 plate ceiling roseconforming to IS: 371/1999 or latest and withall standard accessories complete and in amanner as directed by Section Engineer incharge at site. | — | 300.00 | — | — | |
| — | — | — | Above/ 14400.00 Below/P | ||
| Supply of 6A Modular switches conforming toIS: 3854/ 1997 or latest and provision of thesame in switchboards or elsewhere in amanner as directed by Section Engineer-incharge at site. The unit shall be integratedinto modular plates/boxes, including internalwiring terminations. | — | 600.00 | — | — | |
| — | — | — | Above/ 15800.00 Below/P | ||
| Supply of 6A Modular sockets conforming toIS: 1293/ 2019 or latest and provision of thesame in switchboards or elsewhere in amanner as directed by Section Engineer-incharge at site. The unit shall be integratedinto modular plates/boxes, including internalwiring terminations. | — | 200.00 | — | — | |
| — | — | — | Above/ 6300.00 Below/P | ||
| Supply of 16A Modular switches conformingto IS: 3854/ 1997 or latest and provision ofthe same in switchboards or elsewhere in amanner as directed by Section Engineer-incharge at site. The unit shall be integratedinto modular plates/boxes, including internalwiring terminations. | — | 100.00 | — | — | |
| — | — | — | Above/ 8000.00 Below/P | ||
| Supply of 16/6A Modular sockets conformingto IS: 1293/ 2019 or latest and provision ofthe same in switchboards or elsewhere in amanner as directed by Section Engineer-incharge at site. The unit shall be integratedinto modular plates/boxes, including internalwiring terminations. | — | 100.00 | — | — | |
| — | — | — | Above/ 7770.00 Below/P | ||
| Installation, Testing and commissioning of200 W LED Flood light fittings using suitableGI tubular mounting arm bent to act astubular support for anchoring arrangementonto walls including supply connection fromceiling rose/junction box or elsewhere byusing 3 core 1.5 sq. mm Fire retardant lowsmoke PVC insulated ,PVC round sheathedcopper[White/Ivory colour] conductor flexiblechord conforming to IS:694/1990 or latest asper industrial standards in a manner asdirected by Section Engineer in charge atsite.Note: 200W LED Flood light fittings alonewill be supplied departmentally | — | 30.00 | — | — | |
| — | — | — | Above/ 3600.00 Below/P | ||
| Installation, Testing and commissioning ofMobile charging assembly of size(360x300x100mm) made of CRCA sheetwith minimum thickness 1.2mm consisting of6A 1 way switch and 6A sockets along with25A,30 mA, DP,RCCB with suitable fixingarrangements complete in a suitable manneras directed by Section Engineer incharge atsiteNote: Mobile charging assembly alonewill be supplied Departmentally | — | 50.00 | — | — | |
| — | — | — | Above/ 4550.00 Below/P | ||
| Installation, Testing and Commissioningincluding concealing work along with metalclad plug and socket unit in sheet steelenclosure conforming to IS: 8623/1993 orlatest complete as per industrial practiceswith 1 No. 20 SP, MCB onto the wallsincluding cutting/chipping and replasteringand bringing back walls to original conditionincluding painting in a manner as directed bysection engineer in charge at site.Note: Metal clad plug and socket withEnclosure and MCB alone will besupplied Departmentally. | — | 50.00 | — | — | |
| — | — | — | Above/ 3860.00 Below/P | ||
| — | 5.00 | — | — | ||
| — | - Installation, adaptor box and condition complete at | Testing and as Incomer along with(24 on tothe wall using replasteringand bringing back complete including allwiring andas per industrial practices site.Note: MCB DB, MCB, | TPN MCB DB's feedercontrols along workand including including painting bothincoming by Senior Section etc. alone will | ||
| — | — | — | Above/ 3573.00 Below/P | ||
| Erection, Testing and commissioning of 6way Floor Mounting Type MCCB DB with400A,,50kA,FP,MCCB as Incomer alongwith (6 No's 200A) ,36kA,FP,MCCB's asoutgoing including all cable termination atboth Incoming and Outgoing sides completeand as per industrial practices complete in amanner as directed by Senior SectionEngineer in charge at site.Note: MCCB DB, ,MCCB alone will besupplied Departmentally | — | 1.00 | — | — | |
| — | — | — | Above/ 3573.00 Below/P | ||
| Erection, Testing and commissioning of 8way Floor Mounting Type MCCB DB with200A,36kA, FP, MCCB's as Incomer alongwith (8 No's 63A) ,30kA, FP,MCCB asoutgoing including all cable termination atboth Incoming and Outgoing sides completeand as per industrial practices complete in amanner as directed by Senior SectionEngineer in charge at site.Note: MCCB DB, MCCB alone will besupplied Departmentally | — | 1.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Technicaldocuments.pdf
ATTACHMENT
Checklistlessthan50Lakh.pdf
ATTACHMENT
GCCandACS1-12.pdf
ATTACHMENT
GeneralinstructionstoTenderers.pdf
ATTACHMENT
ImportantinstructionstoTenderers.pdf
ATTACHMENT
ModelformofBGbondwithinstructions.pdf
ATTACHMENT
NEFTFORM.pdf
ATTACHMENT
Payment_clause_for_LED_luminaries_and_BLDC_fansasper2026.pdf
ATTACHMENT
Special_conditions_of_Contract_Electrical.pdf
ATTACHMENT
StandardGuaranteecertificateformat.pdf
ATTACHMENT
Undertakings.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .